Property report

7701r Burholme Ave

107,391 sqftSPINSbuilt 1950

Property at a glanceCommercial

Individual owner on record

2026 assessment
$50M OPA value, not a listing price
2027 published assessment
$50M Future roll, not the current tax bill
Neighborhood area
Fox Chase · Burholme Approximate · based on ZIP 19111
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $50,360,400. It is not yet the billed-year tax basis.

$0$50M$100M$50M200820122016202020242027
Property assessmentAssessmentL&I violationPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record124 events · exact dates, newest first
  1. PermitAddition and/or Alteration
  2. PermitAddition and/or Alterations
  3. PermitAddition and/or Alteration
  4. PermitAddition and/or Alterations
  5. PermitAddition and/or Alteration
  6. PermitAddition and/or Alterations
  7. CertificationSprinkler Certification
  8. PermitAddition and/or Alteration
  9. CertificationFire Alarm Certification
  10. PermitAddition and/or Alterations
  11. PermitAddition and/or Alteration
  12. PermitAddition and/or Alteration
  13. PermitAlterations
  14. PermitAddition and/or Alterations
  15. PermitAddition and/or Alterations
  16. PermitAddition and/or Alteration
  17. CertificationSpecial Hazards Certification
  18. CertificationSpecial Hazards Certification
  19. CertificationSprinkler Certification
  20. CertificationSprinkler Certification
  21. PermitAddition and/or Alteration
  22. CertificationFire Alarm Certification
  23. PermitAddition and/or Alteration
  24. InspectionL&I investigation
  25. PermitAddition and/or Alterations
  26. PermitAlterations
  27. PermitAddition and/or Alteration
  28. CertificationSpecial Hazards Certification
  29. PermitAddition and/or Alterations
  30. CertificationSprinkler Certification
  31. CertificationFire Alarm Certification
  32. CertificationFacade Report
  33. CertificationFacade Report
  34. PermitAddition and/or Alterations
  35. PermitAddition and/or Alteration
  36. PermitAddition and/or Alterations
  37. PermitAddition and/or Alteration
  38. PermitAddition and/or Alteration
  39. PermitAddition and/or Alterations
  40. PermitAlterations
  41. PermitAlterations
  42. PermitAddition and/or Alterations
  43. PermitAddition and/or Alteration
  44. L&I violationPERIODIC TESTING
  45. InspectionL&I investigation
  46. PermitAddition and/or Alteration
  47. CertificationSpecial Hazards Certification
  48. CertificationSpecial Hazards Certification
  49. PermitAddition and/or Alterations
  50. PermitAddition and/or Alterations
  51. PermitAddition and/or Alterations
  52. PermitAddition and/or Alteration
  53. CertificationSprinkler Certification
  54. CertificationSprinkler Certification
  55. PermitAlterations
  56. PermitAddition and/or Alteration
  57. CertificationFire Alarm Certification
  58. PermitAddition and/or Alterations
  59. PermitAlterations
  60. PermitAddition and/or Alteration
  61. PermitAddition and/or Alteration
  62. PermitAlterations
  63. PermitAddition and/or Alterations
  64. PermitAddition and/or Alteration
  65. PermitTank Install/Removal
  66. PermitAddition and/or Alteration
  67. PermitAddition and/or Alterations
  68. PermitAlterations
  69. PermitAddition and/or Alteration
  70. PermitAddition and/or Alteration
  71. PermitSuppression
  72. PermitElectrical
  73. PermitPlumbing
  74. PermitMajor alteration
  75. PermitElectrical
  76. PermitSuppression
  77. PermitSuppression
  78. PermitElectrical
  79. PermitElectrical
  80. PermitPlumbing
  81. PermitPlumbing
  82. PermitMajor alteration
  83. PermitMajor alteration
  84. PermitMajor alteration
  85. PermitSuppression
  86. PermitSuppression
  87. PermitZoning/use
  88. PermitSuppression
  89. PermitSuppression
  90. PermitAdministrative
  91. PermitUse
  92. PermitMechanical
  93. PermitMajor alteration
  94. PermitMajor alteration
  95. PermitSuppression
  96. PermitMajor alteration
  97. PermitMechanical
  98. PermitSuppression
  99. PermitMajor alteration
  100. PermitElectrical
  101. PermitMajor alteration
  102. PermitMechanical
  103. PermitMajor alteration
  104. PermitSuppression
  105. InspectionPP_PLUMB
  106. PermitPlumbing
  107. L&I violationPENALTY- NO PLUMB PERM INFO
  108. L&I violationPERMP- INST SANITARY PIPE SYS
  109. L&I violationPERMP- ALTER/REPAIR/REPL PLUMB
  110. L&I violationPERMP- REQUIRED TO CORR VIOL
  111. L&I violationPERMP- INST DOMEST PIPE SYS
  112. InspectionPP_PLUMB
  113. PermitMajor alteration
  114. PermitSuppression
  115. PermitSuppression
  116. PermitSuppression
  117. PermitMechanical
  118. PermitMajor alteration
  119. PermitSuppression
  120. PermitSuppression
  121. PermitMechanical
  122. PermitZoning/use
  123. PermitMajor alteration
  124. PermitMajor alteration

Verify the public record

$6,212/year estimated property tax

2026 taxable assessment $443,763 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $50,360,400. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 778022500
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $443,763 of $50,360,400 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources Record found

$33,400.79 was recorded for this parcel in Philadelphia's June 2022 delinquency snapshot for 2018–2021. That amount may have been paid, reduced, or increased since; it is not a current payoff figure.

$22,668.15 principal$3,756.47 interest$1,515.33 penalty$5,460.84 other charges
4years recorded 2018–2021tax periods Yesactionable flag Nopayment agreement Nobankruptcy flag Noassessment appeal

The snapshot’s 2022 context used $50,360,400 total assessment, $443,763 taxable, and $49,916,637 exempt/abated. Those historical fields can differ from today’s OPA exemption status.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

$33K · Jun 2022 delinquency snapshot

What it is
Commercial Misc Research Masonry
Owner
Individual owner on record Individual name redacted
$ / sq ft
$469 above the $151 median for 7,668 commercial parcels citywide
Interior area
107,391 sqft
Lot size
595,695 sqft
Built
1950
Zoning
SPINS

Block context

7700 block of Burholme Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 7701 Burholme Ave  ·  7703 Burholme Ave

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 124 dated rows
  1. PermitAddition and/or Alteration

    Permit EP-2026-001987 · Completed

    Install new 10kVA 120 isolation panel system with line isolation monitor in Operating Room #6 to support robotic surgery equipment, including feeder installation from panel LP-XD and associated circuiting. Scope includes installation of dedicated receptacles, stainless steel surface raceway, conduit infrastructure for future data drops. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  2. PermitAddition and/or Alterations

    Permit FP-2026-000221 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (116) SPRINKLER HEADS PER NFPA 13

  3. PermitAddition and/or Alteration

    Permit CP-2026-000342 · Issued

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO LEVEL 1 OF AN EXISTING MEDICAL FACILITY (WEST BUILDING, FOX CHASE CANCER CENTER) AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  4. PermitAddition and/or Alterations

    Permit MP-2025-003595 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  5. PermitAddition and/or Alteration

    Permit EP-2025-007180 · Completed

    INSTALL TELECOMMUNICATIONS WIRING. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC.

  6. PermitAddition and/or Alterations

    Permit MP-2025-003756 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  7. CertificationSprinkler Certification

    Certification BC-2025-020151 · Certified

    Expires 2026-07-22

  8. PermitAddition and/or Alteration

    Permit CP-2025-003159 · Completed

    FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, FIXTURES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  9. CertificationFire Alarm Certification

    Certification BC-2025-019707 · Certified

    Expires 2026-06-14

  10. PermitAddition and/or Alterations

    Permit FP-2025-001155 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 9 Heads

  11. PermitAddition and/or Alteration

    Permit EP-2025-003954 · Completed

    Cabling will be Superior/Essex Category 6A plenum rated 4-pair. • Provide labor to demo existing low voltage cabling as required from the space. • Provide and install five (5) flush mount dual locations. • Provide and install six (6) flush mount single locations. • Provide and install Ortronics faceplates and modular jacks as required for termination of the 4-pair cables at the workstation location. • Provide and install one (1) Ortronics 48-port modular patch panel loaded with the required modular jacks. This will be installed at the appropriate closet location for termination of the 4-pair cables installed. • Provide and install all necessary j-hooks as required to facilitate cable distribution. • Provide labor and materials to seal all through penetrations of fire rated walls for telecommunications use to maintain necessary fire ratings. • Bluestone Communications, Inc. will provide labor to test and label all new cabling installed by Bluestone Communications, Inc. throughout the facility. Test results will be submitted as part of the as built package. -2017 NEC.

  12. PermitAddition and/or Alteration

    Permit EP-2024-012153 · Completed

    INSTALL NEW LIGHT FIXTURES USING THE EXISTING CIRCUITS. INSTALL NEW AND RELOCATE EXISTING LIGHTING CONTROLS. INSTALL NEW RECEPTACLES ON THE EXISTING CIRCUITS. PROVIDE POWER FOR THE LAMINAR FLOW HOODS INSTALL NEW FIRE ALARM STROBES ON THE EXISTING FIRE ALARM CIRCUITS. RELOCATE EXISTING FIRE ALARM STROBE & SMOKEDETECTOR. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.

  13. PermitAlterations

    Permit PP-2024-016987 · Completed

    Install (1) sink (other) and all associated piping as per plans

  14. PermitAddition and/or Alterations

    Permit MP-2024-005815 · Completed

    FOR THE INSTALLATION OF REGISTERS, AND DIFFUSERS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  15. PermitAddition and/or Alterations

    Permit FP-2024-002607 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 7 SPRINKLER HEADS TO ACCOMODATE NEW RENOVATION

  16. PermitAddition and/or Alteration

    Permit CP-2024-004930 · Completed

    FOR LEVEL II ALTERATIONS TO 4th FLOOR IN AN EXISTING STRUCTURE (WITH NO CHANGE IN OCCUPANCY) PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.

  17. CertificationSpecial Hazards Certification

    Certification BC-2024-025914 · Certified

    Expires 2025-09-09

  18. CertificationSpecial Hazards Certification

    Certification BC-2024-025911 · Certified

    Expires 2025-09-09

  19. CertificationSprinkler Certification

    Certification BC-2024-021796 · Certified

    Expires 2025-07-24

  20. CertificationSprinkler Certification

    Certification BC-2024-021532 · Certified

    Expires 2025-07-11

  21. PermitAddition and/or Alteration

    Permit CP-2024-003031 · Completed

    FOR INTERIOR RENOVATIONS TO EXISTING VAULT WITHIN AN EXISTING MEDICAL OFFICE BUILDING AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK.

  22. CertificationFire Alarm Certification

    Certification BC-2024-022746 · Certified

    Expires 2025-06-12

  23. PermitAddition and/or Alteration

    Permit EP-2024-002137 · Completed

    Renovation of existing building area into new offices. Selective electrical demolition of existing space. New 120/208V sub panel to serve office area, new lighting fixtures and controls, new receptacles and branch wiring, rough-in of tele/data outlet locations as per 2017 NEC. Modifications to fire alarm system including local NAC extender panel, smoke detectors and notification devices as per 2016 NFPA 72.

  24. InvestigationL&I investigation

    Case CF-2023-016825 · PASSED

    The cited inspection visit was marked passed.

  25. PermitAddition and/or Alterations

    Permit MP-2024-001027 · Completed

    FOR ALTERATIONS TO HVAC SYSTEM TO REPLACE REGISTERS AND DIFFUSERS WITH ASSOCIATED DUCTWORK AND ACCESSORIES AS PER PLANS.

  26. PermitAlterations

    Permit PP-2024-003103 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  27. PermitAddition and/or Alteration

    Permit CP-2024-000687 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO AN EXISTING OFFICE SPACE ON THE THIRD FLOOR OF AN EXISTING MEDICAL OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  28. CertificationSpecial Hazards Certification

    Certification BC-2024-007577 · Certified

    Expires 2025-02-13

  29. PermitAddition and/or Alterations

    Permit MP-2023-004765 · Completed

    FOR THE INSTALLATION OF A NEW HVAC SYSTEMS, ASSOCIATED DUCT WORK, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION

  30. CertificationSprinkler Certification

    Certification BC-2024-011966 · Certified

    Expires 2024-10-17

  31. CertificationFire Alarm Certification

    Certification BC-2024-003295 · Certified

    Expires 2024-10-05

  32. CertificationFacade Report

    Certification BC-2023-018027 · Safe

    Expires 2028-08-01

  33. CertificationFacade Report

    Certification BC-2023-018029 · Safe

    Expires 2028-08-01

  34. PermitAddition and/or Alterations

    Permit MP-2023-002755 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM FOR A THIRD FLOOR MEDICAL OFFICE SPACE AS PER APPROVED PLANS. *2018 IMC REVIEW*

  35. PermitAddition and/or Alteration

    Permit EP-2023-005012 · Completed

    RELOCATE, CLEAN & RELAMP THE LIGHT FIXTURES & EXIT SIGN, INSTALL NEW OCCUPANCY SENSORS. INSTALL ADDITIONAL RECEPTACLE OUTLETS, FURNITURE FEEDERS, & CONDUITS & BOXES FOR TELE COM WIRING. PROVIDE POWER FOR THE VAV UNIT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. * THE ELECTRIC PANELS ARE EXISTING.

  36. PermitAddition and/or Alterations

    Permit FP-2023-001369 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 54 SPRINKLER HEADS

  37. PermitAddition and/or Alteration

    Permit CP-2023-002737 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO AN EXISTING OFFICE SPACE ON THE THIRD FLOOR OF AN EXISTING MEDICAL OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  38. PermitAddition and/or Alteration

    Permit EP-2023-004144 · Completed

    Install new light fixtures, lighting controls, receptacles, tele/data raceways .Install Fire Alarm . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  39. PermitAddition and/or Alterations

    Permit MP-2023-001783 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  40. PermitAlterations

    Permit PP-2023-004588 · Completed

    Demo of existing fixtures Install one new sink with necessary waste, vent and domestic water piping

  41. PermitAlterations

    Permit PP-2023-005122 · Completed

    MODIFICATIONS AS PER DRAWINGS OF EXISTING SPACE TO INCLUDE NEW SEWAGE EJECTOR, FLOOR DRAIN, KITCHENETTE SINK, & SCRUB SINK

  42. PermitAddition and/or Alterations

    Permit FP-2023-000813 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (13) sprinkler heads on first floor, Suite 1000

  43. PermitAddition and/or Alteration

    Permit CP-2023-001593 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING RETAIL & CONSULTATION SPACE WITHIN AN EXISTING MEDICAL OFFICE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  44. ViolationPERIODIC TESTING

    Case CF-2023-016825 · Violation VI-2023-012697 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  45. InvestigationL&I investigation

    Case CF-2023-016825 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  46. PermitAddition and/or Alteration

    Permit CP-2023-000247 · Completed

    FOR LEVEL II ALTERATIONS TO INCLUDE STRUCTURAL WORK, NEW PARTITIONS, FIXTURES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  47. CertificationSpecial Hazards Certification

    Certification BC-2023-003934 · Certified

    Expires 2024-02-21

  48. CertificationSpecial Hazards Certification

    Certification BC-2023-004274 · Certified

    Expires 2024-02-21

  49. PermitAddition and/or Alterations

    Permit FP-2022-002583 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. WORK DESCRIPTION HAS BEEN CHANGED TO RELOCATE (7) EXISTING HEADS TO NEW CEILING LAYOUT, FOX CHASE CANCER CENTER, YOUNG PAVILION LOWER LEVEL VAULT 2. PREVIOUS WORK DESCRIPTION (relocate existing upright sprinkler heads to pendant type) EXCEEDS THE EZ STANDARD, AND WILL VOID THIS PERMIT..

  50. PermitAddition and/or Alterations

    Permit FP-2022-002587 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. WORK DESCRIPTION HAS BEEN CHANGED TO RELOCATE (8) EXISTING HEADS TO NEW CEILING LAYOUT, FOX CHASE CANCER CENTER, YOUNG PAVILION LOWER LEVEL. PREVIOUS WORK DESCRIPTION (relocate existing upright sprinkler heads to pendant type) EXCEEDS THE EZ STANDARD, AND WILL VOID THIS PERMIT.

  51. PermitAddition and/or Alterations

    Permit MP-2022-003406 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  52. PermitAddition and/or Alteration

    Permit EP-2022-006597 · Completed

    INSTALL LIGHTS NORMAL & EMERGENCY, SYSTEM WARNING LIGHT, SWITCHES, RECEPTACLES, & EPO BUTTON. INSTALL CONDUITS FOR EQUIPMENT, 60 AMP FEEDERS TO THE NEW ACCLEERATOR PANEL & LINEAR ACCELERATOR. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. ** NO FIRE ALARM WORK.

  53. CertificationSprinkler Certification

    Certification BC-2022-014325 · Certified

    Expires 2023-07-20

  54. CertificationSprinkler Certification

    Certification BC-2022-013230 · Deficient

  55. PermitAlterations

    Permit PP-2022-010475 · Completed

    Install of water piping to fixture. Install of waste piping from fixture. Install (1) sink.

  56. PermitAddition and/or Alteration

    Permit CP-2022-002766 · Completed

    For alterations to the existing vault to accommodate linear accelerator equipment replacement as per approved plans.

  57. CertificationFire Alarm Certification

    Certification BC-2022-007290 · Certified

    Expires 2023-05-20

  58. PermitAddition and/or Alterations

    Permit MP-2022-002770 · Completed

    FOR THE INSTALLATION OF HVAC SYSTEMS TIED INTO EXISTING, ASSOCIATED DUCT WORK, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION

  59. PermitAlterations

    Permit PP-2022-007678 · Completed

    Install waste piping from fixture. Install water piping to fixture. Install (1) Sink AS PER PPC 2018

  60. PermitAddition and/or Alteration

    Permit EP-2022-003849 · Completed

    Alterations to install a new linear accelerator medical equipment in Fox Chase Cancer Center, including new interior wiring, hospital grade receptacles, lighting fixtures, power conditioner equipment, HVAC equipment power connections. All work to be per the 2017 NEC. Existing fire alarm system devices to remain.

  61. PermitAddition and/or Alteration

    Permit EP-2022-003732 · Completed

    Demo electric to existing MRI equipment. Provide electric feeders to new MRI equipment, new chiller, and new lighting fixtures and controls as per 2017 nec

  62. PermitAlterations

    Permit PP-2022-005805 · Completed

    Scope of proposed work does not require review. Issue ez-permit.

  63. PermitAddition and/or Alterations

    Permit MP-2022-002169 · Expired

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (relocate two diffusers to accommodate replacement of existing MRI).

  64. PermitAddition and/or Alteration

    Permit CP-2022-001896 · Completed

    FOR INTERIOR ALTERATIONS ON THE 3RD FLOOR OF AN EXISTING HOPITAL, TO INCLUDE INTERIOR PARTITIONS, INTERIOR FINISHES AND REPLACING EXISTING MRI WITH A NEW GE ARTIS MRI, PER SUBMITTED PLANS.

  65. PermitTank Install/Removal

    Permit GP-2022-000648 · Completed

    REMOVAL OF AN 275 GAL UNDERGROUND FUEL TANK, AND INSTALLATION OF NEW 500 GAL ABOVE GROUND FUEL TANK AS PER APPROVED PLAN.

  66. PermitAddition and/or Alteration

    Permit CP-2022-001233 · Completed

    For alterations to the existing vault to accomondate linear accelerator equipment replacement as per approved plans.

  67. PermitAddition and/or Alterations

    Permit MP-2021-005179 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK FOR AN EXISTING HEALTH FACILITY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  68. PermitAlterations

    Permit PP-2021-014778 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  69. PermitAddition and/or Alteration

    Permit EP-2021-006719 · Completed

    Electrical installation of a new Linear Accelerator Medical Equipment at Fox Chase Cancer Center. Work to include power connections and communications raceways to new medical equipment, installation of power conditioner, lighting and lighting controls, general receptacles, branch wiring, power connections to HVAC CRAC units. Existing fire alarm devices remain. All work to comply with the 2017 NEC.

  70. PermitAddition and/or Alteration

    Permit CP-2021-003372 · Completed

    No change in use and occupancy classification Interior alterations as per approved plans.

  71. PermitSuppression

    Permit 979447 · COMPLETED

    RELOCATE 21 EXISTING SPRINKLER HEADS.

  72. PermitElectrical

    Permit 720963 · COMPLETED

    RENOVATE EXISTING SPACE INTO A RETAIL PHARMACY PER 2008 NEC (HEALTH CARE FACILITY)EAST DISTRICT REMOVE AND REINSTALL 2 FIRE ALARM DEVICES NO CHANGE TO EXISTING FA SYSTEM PER NFPA 72

  73. PermitPlumbing

    Permit 713029 · COMPLETED

    INSTALL A HAND SINK FOR NEW PHARMACY LAYOUT. THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  74. PermitMajor alteration

    Permit 703049 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS TO CONVERT A FIRST FLOOR CONFERENCE ROOM TO AN ACCESSORY PHARMACY FOR AN EXISTING MEDICAL FACILITY AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  75. PermitElectrical

    Permit 693259 · COMPLETED

    REPLACE 1-CT SCAN UNIT, F&I 3-RECEPTS, 1-125MOB 18CKT 480/277 PANEL, 1-POWER CONITIONER, EMG POWER OFF BUTTON, SURF MTD FLOOR DUCT TO NEW UNIT, REPLAMP 13- FIXTURES AS PER NEC 2008 EAST DISTRICT

  76. PermitSuppression

    Permit 652037 · COMPLETED

    FOR THE EXTENSION OF AN EXISTING FIRE SUPRESSION SYSTEM IN TO A TENANT SPACE IN A BUILDING FOR USE AS A HEALTH FACILITY. FIRE SUPRESSION SYSTEM TO BE SERVICED BY AN EXISTING SIX INCH FIRE SERVICE LINE WITH AN EXISTING BACKFLOW PREVENTER ASSEMBLY AND AN EXISTING FIRE PUMP. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13.

  77. PermitSuppression

    Permit 652036 · COMPLETED

    FOR ALTERATIONS TO AN EXISTING FIRE SUPPRESSION SYSTEM TO PROVIDE PROTECTION IN A NEW MEDICAL OFFICE AS WELL AS RELOCATE HEADS IN SURROUNDING OFFICE SPACE. ALL SPRINKLERS TO TIE INTO EXISTING FIRE SERVICE MAIN LINE AND MAINTAIN CONNECTION WITH BACKFLOW PREVENTION ASSEMBLY.

  78. PermitElectrical

    Permit 649798 · COMPLETED

    INSTALL (1) PET/MRI IN EXISTING OFFICE. INCLUDES LIGHT FIXTURES, DEVICES AND LOW VOLTAGE WIRING PER NEC CODE 2008 & FIRE ALARM INCLUDES RELOCATION OF EXISTING DEVICES AS PER NFPA 72

  79. PermitElectrical

    Permit 649796 · COMPLETED

    INSTALL (1) LINEAR ACCELERATOR IN EXISTING OFFICE. INCLUDES LIGHT FIXTURES, DEVICES, & LOW VOLTAGE WIRING PER NEC CODE 2008 & FIRE ALARM INCLUDES RELOCATION OF EXISTING DEVICES AS PER NFPA 72

  80. PermitPlumbing

    Permit 653927 · COMPLETED

    INSTALL 2 SINKS, 1 WATER CLOSET & 1 LAVY SINK TO NEW ROUGH IN - THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  81. PermitPlumbing

    Permit 650151 · COMPLETED

    INSTALL ONE HUB DRAIN TO NEW TOUGH IN INSTALL ONE SINK TO NEW ROUGH IN - THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  82. PermitMajor alteration

    Permit 629847 · COMPLETED

    INTERIOR DEMO AND FIT OUT FOR PET/MRI PER ATTACHED PLANS.

  83. PermitMajor alteration

    Permit 629887 · COMPLETED

    INTERIOR DEMO AND FIT OUT FOR LINEAR ACCELAERATOR PER ATTACHED PLANS

  84. PermitMajor alteration

    Permit 629891 · COMPLETED

    INTERIOR DEMO AND FIT OUT FOR CT REPLACEMENT PER ATTACHED PLANS

  85. PermitSuppression

    Permit 480580 · COMPLETED

    CONNNECTING TO EXISTING 6" UNDERGROUND MAIN AND WILL BE INSTALLING NEW 6" UNDERGROUND MAIN TO NEW HYDRANT, CONNECTING TO 6" UNDERGROUND MAN EXISTING PUMP IN BUILDING AT FOX CHASE CANCER ,

  86. PermitSuppression

    Permit 454969 · COMPLETED

    INSTALLATION OF MAINS, LINES, FIRE PUMP AND (316) SPRINKLERS IN ACCORDANCE WITH NFPA 13, ON FLOORS 1-4 AS PER PLANS.

  87. PermitZoning/use

    Permit 405951 · COMPLETED

    INSTALL A CONTINUATION OF A METAL ROOF SCREEN WITH SOUND ATTENUATION PANELS. INSTALL GALVANIZED STEEL STRUCTURE ON ROOF AS PER PLANS.

  88. PermitSuppression

    Permit 371162 · COMPLETED

    RELOCATE 8 SPRINKLER HEADS (1ST FLOOR - WOMAN'S BOUTIQUE)

  89. PermitSuppression

    Permit 358085 · COMPLETED

    INSTALL (2) ANSUL COMMERCIAL KITCHEN SUPPRESSION SYSTEM FOR CANCER CENTER CAFETERIA.

  90. PermitAdministrative

    Permit 357240 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY - PHASE 1 - RENOVATIONS TO KITCHEN, OFFICES, ETC FOR LEVEL 2 ALTERATIONS TO INCLUDE NEW WALLS, CEILINGS, FINISES AND MEP. RENOVATIONS TO SEATING AREA FOR CANCER CENTER

  91. PermitUse

    Permit 356820 · COMPLETED

    ZONING USE CHANGE FOR 1ST FL

  92. PermitMechanical

    Permit 332997 · COMPLETED

    ALTERATIONS TO EXISTING HVAC SYSTEM AS PART OF RENOVATION TO EXISTING CAFETERIA/SERVERY, INCLUDING INSTALLATION OF 3 COMMERCIAL KITCHEN HOODS AND EXHAUST SYSTEMS. MECHANICAL PLANS INCLUDED WITH BASE BUILDING PLANS UNDER AP #328776.

  93. PermitMajor alteration

    Permit 328776 · COMPLETED

    RENOVATIONS TO KITCHEN, OFFICES, ETC FOR LEVEL 2 ALTERATIONS TO INCLUDE NEW WALLS, CEILINGS, FINISES AND MEP. RENOVATIONS TO SEATING AREA FOR CANCER CENTER.

  94. PermitMajor alteration

    Permit 335657 · COMPLETED

    RENOVATION OF EXISTING SPACE, DRYWALL PARTITION, NEW CASEWORK, ADDITIONAL ELECTRIC AND RELOCATE EXISTING DIFFUSERS FOR OUTPATIENT CENTER.

  95. PermitSuppression

    Permit 324104 · COMPLETED

    DEMO EXISTING SPRINKLER SYSTEM AFTER THE INSTALLATION OF NEW SPRINKLER SYSTEM, CONNECT TO EXISTING SYSTEM IN MECHANICAL ROOM.

  96. PermitMajor alteration

    Permit 306177 · COMPLETED

    RENOVATION AND EXPANSION OF CANCER CENTER.

  97. PermitMechanical

    Permit 311110 · COMPLETED

    HVAC-SEE AP#306177 FOR PLANS.

  98. PermitSuppression

    Permit 303658 · COMPLETED

    RELOCATE 80 SPRINKLER HEADS (GROUND FLOOR)

  99. PermitMajor alteration

    Permit 266905 · COMPLETED

    INTERIOR ALTERATIONS TO INCLUDE STRUCTRUAL MODIFICATIONS FOR THE VAULT AREAS, REMOVAL/REPLACEMENT OF LINEAR ACCELERATOR HEAVY EQUIPMENT. FLOOR SLAB MODIFICATIONS, STRUCTURAL REINFORCEMENT, MECHANICAL PIPING & ELECTRICAL UPGRADES, AS PER SUBMITTED PLANS AND SPECIFICATIONS.

  100. PermitElectrical

    Permit 248659 · COMPLETED

    REPLACE EXISTING PROCEDURE EQUIPMENT, LINAC EACH OF TWO ROOMS AS PER 2005 NEC (EAST DIST)

  101. PermitMajor alteration

    Permit 251546 · COMPLETED

    RENOVATIONS TO OUTPATIENT FACILITY TO ACCOMMODATE NE PURCHASED EQUIPMENT AS PER PLANS

  102. PermitMechanical

    Permit 241628 · COMPLETED

    FOR THE HVAC ACTIVITY IN THE LINEAR ACCELERATOR AREA. RELOCATE ONE DIFFUSER TO ACCOMODATE STRUCTURAL ALTERATIONS. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS.

  103. PermitMajor alteration

    Permit 238756 · COMPLETED

    FOR INTERIOR ALTERATIONS TO INCLUDE STRUCTURAL MODIFICATIONS TO REMOVE EXISTING AND REPALCE WITH NEW LINEAR ACCELERATORS. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS.

  104. PermitSuppression

    Permit 219727 · COMPLETED

    PHASE 2 - INSTALLATION OF NEW SPRIKLERS, PIPING, CONNECT TO EXISTING SYSTEM.

  105. InvestigationPP_PLUMB

    Case 198771 · PASSED

    The cited inspection visit was marked passed.

  106. PermitPlumbing

    Permit 215085 · COMPLETED

    1ST FL, REMOVE EXISTING FIXTURES AND REPLACE WITH NEW TO CONFORM WITH NEW CASEWORK AND TO ACCOMMODATE NEW ARCHITECTURAL LAYOUT. 2 WC, 2 LAV, 7 HS, 2 BS

  107. ViolationPENALTY- NO PLUMB PERM INFO

    Case 198771 · Violation 1325124 · Code A-901.13/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  108. ViolationPERMP- INST SANITARY PIPE SYS

    Case 198771 · Violation 1325126 · Code A-301.1/56 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  109. ViolationPERMP- ALTER/REPAIR/REPL PLUMB

    Case 198771 · Violation 1325125 · Code A-301.1/55 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  110. ViolationPERMP- REQUIRED TO CORR VIOL

    Case 198771 · Violation 1325123 · Code A-501.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  111. ViolationPERMP- INST DOMEST PIPE SYS

    Case 198771 · Violation 1325127 · Code A-301.1/57 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  112. InvestigationPP_PLUMB

    Case 198771 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  113. PermitMajor alteration

    Permit 208777 · COMPLETED

    INTERIOR ALTERATIONS TO 1ST FLOOR MEDICAL OFFICES

  114. PermitSuppression

    Permit 201399 · COMPLETED

    NEW INSTALLATION OF (4) CLASS 1 DRY STANDPIPES IN OPEN PARKING GARAGE, AS PER SUBMITTED PLANS AND CALCS.

  115. PermitSuppression

    Permit 201541 · COMPLETED

    INSTALL DRY SPRINKLER SYSTEM AT LOADING DOCK/PARKING GARAGE AREA CONNECTING TO EXISTING SYSTEM, AS PER SUBMITTED PLANS AND CALCS.

  116. PermitSuppression

    Permit 189201 · COMPLETED

    RELOCATE 25 SPRINKLER HEADS, 1ST FLOOR WEST BUILDING

  117. PermitMechanical

    Permit 183111 · COMPLETED

    MECHANICAL DUCT WORK, DIFFUSERS, DEMO & RECONFIGURATION/INSTALLATION, AS PER PLANS.

  118. PermitMajor alteration

    Permit 178907 · COMPLETED

    INTERIOR RENOVATIONS, UPGRADES TO FINISHES, AS PER PLANS

  119. PermitSuppression

    Permit 178148 · COMPLETED

    INSTALL (26) AUTO SPRINKLERS IN DIAGNOSTIC IMAGING PHASE 3. (NOT HEALTH CARE FACILITY)

  120. PermitSuppression

    Permit 164009 · COMPLETED

    INSTALL (26) AUTO SPRINKLERS

  121. PermitMechanical

    Permit 145452 · COMPLETED

    HVAC DUCTWORK WITHIN A PORTION OF THE BARRIER BUILDING AS PER PLANS.

  122. PermitZoning/use

    Permit 155973 · COMPLETED

    FOR THE REMOVAL AND REPLACEMENT OF ROOF TOP MECHANICAL EQUIPMENT. SIZE AND LOCATION AS SHOWN IN THE APPLICATION.ROOF TOP MECHANICAL EQUIPMENT ACCESSORY TO AN EXISTING HOSPITAL COMPLEX.

  123. PermitMajor alteration

    Permit 145665 · COMPLETED

    INTERIOR RENOVATIONS TO A PORTION OF THE SECOND AND THIRD FLOOR TO INSTALL A NEW AUTOCLAVE WITHIN ANIMAL ROOM AREAS AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING.

  124. PermitMajor alteration

    Permit 126379 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLAN.FOR LINEAR ACCELERATOR P2 REPLACEMENT

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 8:00 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)