Industrial property report

775 S Christopher Columbus Blvd

Research this property with Analyst →

2 stories93,984 sqftCMX3built 1940

Property at a glanceIndustrial building

Pier 38-40 LLC

2026 assessment
$6.6M OPA value, not a listing price
2027 published assessment
$6.8M Future roll, not the current tax bill
Neighborhood area
Queen Village · East Passyunk Approximate · based on ZIP 19147
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $6,813,800. It is not yet the billed-year tax basis.

$0$5.0M$10M$6.8M202220232024202520262027
Property assessmentAssessmentL&I violationAppealPermitInspection

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record25 events · exact dates, newest first
  1. PermitSite Clearing or Earth Disturbance ONLY
  2. InspectionL&I investigation
  3. L&I violationBENCHMARKING LATE
  4. InspectionL&I investigation
  5. PermitAddition and/or Alterations
  6. PermitAddition and/or Alterations
  7. PermitAddition and/or Alteration
  8. PermitAddition and/or Alteration
  9. PermitSign
  10. PermitAddition and/or Alteration
  11. AppealZBA Permit Denial - Variance
  12. PermitSigns (Accessory / Non-Accessory)
  13. PermitSign
  14. PermitSigns (Accessory / Non-Accessory)
  15. InspectionL&I investigation
  16. PermitAddition and/or Alteration
  17. InspectionL&I investigation
  18. PermitChange of Use
  19. L&I violationUNSAFE STRUCTURE
  20. L&I violationEXTERIOR WALLS
  21. L&I violationPIERS & WATERFRONT STRUCTURES INSPECTION REQUIRED
  22. L&I violationARCHITECT/ENGINEER SERVICES
  23. InspectionL&I investigation
  24. PermitLot Line Relocation
  25. PermitChange of Use

Verify the public record

$92,091/year estimated property tax

2026 taxable assessment $6,578,900 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $6,813,800. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 884000077
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Industrial property

Industrial building, recorded in the City's industrial category. The public record and owner trail follow.

What it is
Industrial building Ind Warehouse Masonry
Owner
Pier 38-40 LLC
$ / sq ft
$72 above the $70 median for 3,574 industrial parcels citywide
Corridor
Central Waterfront/Penns Landing city commercial corridor
Interior area
93,984 sqft
Lot size
238,825 sqft
Stories
2
Built
1940
Zoning
CMX3

Recorded owner

Who's behind it

Pier 38-40 LLC · corporate / LLC owner

• Tax bills mail to 1520 Locust St, Philadelphia PA, 19102

Block context

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 25 dated rows
  1. PermitSite Clearing or Earth Disturbance ONLY

    Permit ZP-2026-003185 · Issued

    FOR RESTORATION AS SHOWN IN PLAN.

  2. InvestigationL&I investigation

    Case CF-2025-131974 · PASSED

    The cited inspection visit was marked passed.

  3. ViolationBENCHMARKING LATE

    Case CF-2025-131974 · Violation VI-2025-095601 · Code 9-3402(2) · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  4. InvestigationL&I investigation

    Case CF-2025-131974 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  5. PermitAddition and/or Alterations

    Permit MP-2024-005296 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  6. PermitAddition and/or Alterations

    Permit MP-2024-004029 · Completed

    FOR THE INSTALLATION OF A NEW HVAC SYSTEMS, ASSOCIATED DUCT WORK, ROOFTOP UNITS, DUCTLESS SYSTEMS, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION.

  7. PermitAddition and/or Alteration

    Permit CP-2024-004016 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO AN EXISTING GROUP S-1 SELF-STORAGE FACILITY TO INCLUDE THE INSTALLATION OF A TWO (2) HOUR RATED ELEVATOR HOISTWAY SHAFT ENCLOSURE AND ELEVATOR MACHINE ROOM, NEW INSULATION AT EXTERIOR WALLS AND ROOF, AND ROOF FRAMING ALTERATIONS IN ASSOCIATION WITH NEW ROOFTOP MECHANICAL WORK. EXISTING BUILDING IS SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC AND PHC APPROVAL. SEPARATE PERMITS REQUIRED FOR ELEVATOR INSTALLATION AND FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK.

  8. PermitAddition and/or Alteration

    Permit EP-2024-005921 · Completed

    New lighting and wiring for a storage facility in an existing building. -2017 NEC. **Separate fire alarm permit req'd**

  9. PermitSign

    Permit GP-2024-004940 · Completed

    FOR THE INSTALLATION OF ONE (1) FLAT STATICALLY ILLUMINATED WALL SIGN. AS PER APPROVED PLANS. FOR USE AS PREVIOUSLY APPROVED. ***************************************** ** ZBA GRANTED HOURS OF ILLUMINATION FROM 6:00AM TO 11:00PM**

  10. PermitAddition and/or Alteration

    Permit EP-2024-005741 · Completed

    Provide automatic fire alarm system throughout building as per 2016 NFPA 72 code and approved plans.

  11. AppealZBA Permit Denial - Variance

    Appeal ZP-2023-013734 · Completed · Granted with conditions

    Related permit ZP-2023-013734 · PERMIT FOR THE INSTALLATION OF ONE (1) FLAT WALL SIGN WITH STATIC ILLUMINATION ACCESSORY TO WHOLESALE DISTRIBUTION AND STORAGE- MOVING AND STORAGE FACILITIES. SIZE AND LOCATION AS SHOWN ON PLANS.

  12. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2023-013734 · Completed

    FOR THE INSTALLATION OF ONE (1) FLAT WALL SIGN WITH STATIC ILLUMINATION. SIZE AND LOCATION AS SHOWN ON PLANS.

  13. PermitSign

    Permit GP-2024-000052 · Completed

    FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED WALL SIGN AS PER APPLICATION/PLAN AND IN ACCORDANCE WITH THE 2018 IBC. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL ELECTRICAL WORK.

  14. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2023-012226 · Issued

    FOR THE REMOVAL OF TWO EXISTING SIGNS AND ERECTION OF ONE (1) ACCESSORY NON-ILLUMINATED FLATWALL SIGN. SIZE AND LOCATION AS SHOWN IN THE PLAN

  15. InvestigationL&I investigation

    Case CF-2023-027744 · PASSED

    The cited inspection visit was marked passed.

  16. PermitAddition and/or Alteration

    Permit CP-2023-000355 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) AT FIRST FLOOR OF EXISTING BUILDING AT PIER 40. FIRE SPRINKLER SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION. *AMEND 5/29/24 - FOR MODIFICATION TO STRUCTURAL COMPONENTS, FLOOR PLAN AND FIRE-RATED ASSEMBLIES PER AMENDED CONSTRUCTION DOCUMENTS*

  17. InvestigationL&I investigation

    Case CF-2023-027744 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  18. PermitChange of Use

    Permit ZP-2023-005014 · Issued

    Wholesale, Distribution, and Storage - Wholesale Sales and Distribution; Wholesale, Distribution, and Storage - Warehouse.; Wholesale, Distribution, and Storage - Equipment and Materials Storage Yards and Buildings; Trucking and Transportation Terminals; Wholesale, Distribution, and Storage - Moving and Storage Facilities

  19. ViolationUNSAFE STRUCTURE

    Case CF-2023-027744 · Violation VI-2023-021233 · Code PM15-108.1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  20. ViolationEXTERIOR WALLS

    Case CF-2023-027744 · Violation VI-2023-021234 · Code PM15-304.1(G) · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  21. ViolationPIERS & WATERFRONT STRUCTURES INSPECTION REQUIRED

    Case CF-2023-027744 · Violation VI-2023-021235 · Code PM15-314 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. ViolationARCHITECT/ENGINEER SERVICES

    Case CF-2023-027744 · Violation VI-2023-021236 · Code A-304.1/1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  23. InvestigationL&I investigation

    Case CF-2023-027744 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  24. PermitLot Line Relocation

    Permit ZP-2023-002131 · Issued

    FOR A LOT ADJUSTMENT (SUBDIVISION) TO CREATE TWO (2) LOTS [PARCELS "A" & "B"] FROM ONE (1) EXISTING LOT [77S S CHRISTOPHER COLUMBUS BLVD]. SIZE AND LOCATION AS SHOWN ON PLANS.

  25. PermitChange of Use

    Permit ZP-2022-003996 · Issued

    Trucking and Transportation Terminals; Wholesale, Distribution, and Storage - Warehouse.

Unavailable when this report assembled: certifications. Unavailable does not mean no record.

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 9:54 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: unavailable. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)