Property report

800s Market St

40,000 sqftbuilt 1960

Property at a glanceCommercial

Septa

2025 assessment
$430K OPA value, not a listing price
2027 published assessment
$459K Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $459,300. It is not yet the billed-year tax basis.

$0$500K$1.0M$459K2010201320162019202220252027
Property assessmentAssessmentL&I violationPermitInspection

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record22 events · exact dates, newest first
  1. PermitAddition and/or Alteration
  2. PermitAddition and/or Alteration
  3. PermitAddition and/or Alteration
  4. InspectionBP_BLDG
  5. PermitPlumbing
  6. InspectionBP_BLDG
  7. L&I violationPERMP- INST NEW PLUMBING
  8. InspectionBP_BLDG
  9. PermitElectrical
  10. PermitMajor alteration
  11. PermitElectrical
  12. PermitElectrical
  13. PermitMajor alteration
  14. PermitElectrical
  15. PermitElectrical
  16. PermitElectrical
  17. PermitElectrical
  18. PermitElectrical
  19. PermitMajor alteration
  20. PermitElectrical
  21. PermitElectrical
  22. PermitSuppression

Verify the public record

$4,614/year estimated property tax

2025 taxable assessment $329,600 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $459,300. It is not the 2025 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 875100690
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2025 OPA taxes $329,600 of $429,600 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Not a house

Commercial. A $0 assessment-based estimate does not prove the live Tax Center account has no prior-period balance or other charges.

What it is
Commercial Misc Rr Sta Masonry
Owner
Septa Public / institutional
$ / sq ft
$11 below the $151 median for 7,668 commercial parcels citywide
Corridor
Market East city commercial corridor
Interior area
40,000 sqft
Lot size
40,000 sqft
Built
1960

Recorded owner

Who's behind it

Septa · corporate / LLC owner

• Owns 295 properties across Philadelphia under this name, assessed at $217M combined
• Tax bills mail to 1234 Market St, Philadelphia PA, 19107

Block context

800 block of Market St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 800-38 Market St  ·  801 Market St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 22 dated rows
  1. PermitAddition and/or Alteration

    Permit CP-2026-003232 · Issued

    FOR THE ERECTION OF AN ELEVATOR WITHIN AN EXISTING ELEVATOR SHAFTWAY BETWEEN THE STREET LEVEL AND CONCOURSE LEVELS FOR ACCESSIBLE ACCESS TO THE EXISTING PUBLIC TRANSIT SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMIITS TO BE OBTAINED FOR ALL OTHER WORK. **NO EXCAVATION WITH THIS PERMIT** **ELEVATOR PERMIT FROM THE COMMONWEALTH OF PENNSYLVANIA IS REQUIRED**

  2. PermitAddition and/or Alteration

    Permit CP-2025-004625 · Issued

    FOR THE REPLACEMENT OF ELEVATOR CAB AND ALTERATION TO THE MACHINE ROOM OF ELEVATOR 1. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. **SEPARATE PERMITS REQUIRED FOR ELECTRICAL, MECHANICAL WORK**

  3. PermitAddition and/or Alteration

    Permit EP-2025-006554 · Issued

    Provision of all power to elevator equipment and appurtenances, elevator car and all appurtenances, receptacles, new feeders, and breakers as required. Provision of all power to equipment in elevator machine room, power to new mechanical equipment (split systems, pumps etc.), new pit receptacles and lighting, switching, new lighting to elevator machine room. Emergency telephone line , provision and wiring of new fire alarm devices, panel, and power to controller(s) for CCTV. Provision of security system components and wiring .ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2018 PHILA FIRE CODE.

  4. InvestigationBP_BLDG

    Case 567802 · PASSED

    The cited inspection visit was marked passed.

  5. PermitPlumbing

    Permit 774990 · COMPLETED

    CLEAN OUT OLD SUMP INSTALLATION OF LINER AND INSTALL NEW SUBMERSIBLE PUMP (SEPTA FACILITY).THE INSTALLATION SHALL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004.

  6. InvestigationBP_BLDG

    Case 567802 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  7. ViolationPERMP- INST NEW PLUMBING

    Case 567802 · Violation 4212952 · Code A-301.1/54 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  8. InvestigationBP_BLDG

    Case 567802 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  9. PermitElectrical

    Permit 660960 · COMPLETED

    REHABILITATION OF EXISTING ELEVATOR,ELECTRICAL DEMOLITION,NEW POWER & LIGHTING CIRCUITS,NEW LIGHT FIXTURES,NEW 120V RECEPTACLES PER 2008 NEC (SEPTA STATION) PROVIDE ADDITIONAL FIRE ALARM DEVICES PER NFPA 72

  10. PermitMajor alteration

    Permit 640200 · COMPLETED

    RENOVATION TO AN EXITING ELEVATOR AS PER PLAN SUBMITTED

  11. PermitElectrical

    Permit 656972 · COMPLETED

    REPLACE IN KIND ONLY: CABINET, ANTENNA.... IN ACCORDANCE WITH 2008 NEC .. NO OTHER WORK ON THIS PERMIT

  12. PermitElectrical

    Permit 587727 · COMPLETED

    PANEL, TRANSFORMER, DISCONNECTS, RECEPTACLES & LIGHTING FOR ESCALATOR REPLACEMENT AS PER NEC 2008 (SEPTA) CC DISTRICT

  13. PermitMajor alteration

    Permit 581425 · COMPLETED

    REMOVE AND REPLACE EXISTING ESCALATORS, INSTALL NEW ESCALATORS, SUPPORT FRAMING, FOOTINGS, MISCELLANEOUS DOORS, FRAMES, HARDWARE, AND GLAZING, PARTITION WALL AT EXISTING SEPTA ESCALATOR AND CONCOURSE AREA 8TH/MARKET SERVICE STATION. NO NEW SIGNS THIS APPLICATION, ANY SIDEWALK R.O.W. CLOSURES OR SIDEWALK/R.O.W. WORK REQUIRES SEPARATE PERMIT AND APPROVALS FROM STREETS DEPARTMENT.

  14. PermitElectrical

    Permit 545773 · COMPLETED

    INSTALL NEW 2" CONDUIT FROM EXISTING SEPTA DEMARK LOCATION TO EXISTING AT&T CELL SITE FOR FUTURE FIBER.

  15. PermitElectrical

    Permit 544922 · COMPLETED

    REMOVE EXISTING TRANSFORMER AND REPLACE WITH LARGER 37.5KVA TRANSFORMER TO FEED AT&T EXISTING CELL SITE WITH A 60AMP SERVICE AS PER 2008 NEC.REFERENCE PREVIOUSLY APPROVED PERMIT # 543858.

  16. PermitElectrical

    Permit 544069 · COMPLETED

    UPGRADE EXISTING AT&T SEPTA CELL SITE WITH THE INSTALLATION OF NEW UMTS2C & LTE EQUIPMENT,60 AMP POWER UPGRADE,GROUNDING AND COMMUNICATION CABLE CONNECTIONS PER 2008 NEC. REFERENCE PREVIOUSLY APPROVED PLAN #540959 (CC DISTRICT)

  17. PermitElectrical

    Permit 481322 · COMPLETED

    INST ELEC SERV PAN 208Y/120V,100A 1PHASE 3 WIRE,NEW 3/4",1",1.5,RIG COND POWER FARE VEND DEV,MAG LOCK,SURF&RECESS LGT.REM OR REL ELEC EQUIP CONTR PROCESS FIRE PULL STATION,CAM,COMM & DATA LINES AS PER NEC 2008 & NFPA 72(SEPTA STATION)

  18. PermitElectrical

    Permit 464978 · COMPLETED

    REPLACE 9 TURNSTILES WITH NO ADD'L WIRING 2 NEW ADA FAREGATE 4 NEW FARE VENDING MACHINES 5 NEW TURNSTILES REWIRE 5 24V MAGNETIC MARGATES MODIFY 5 CKTS TERMINATE 15 BREAKS INSTALL 1 NEW FO CABINET. ALL WORK DONE IN ACCORDANCE WITH 2008 NEC.

  19. PermitMajor alteration

    Permit 445359 · EXPIRED

    FOR THE ALTERATIONS OF TURNSTILE LAYOUTS, WITH ACCESSIBLE FARE GATE AND EMERGENCY EXIT GATES. IEBC 2009--PRESCRIPTIVE METHOD OF COMPLIANCE.

  20. PermitElectrical

    Permit 426142 · COMPLETED

    FURNISH EMPTY CONDUIT IN SUPPORT OF CONCURRENT CONTRACT, NEW PAYMENT TECHNOLOGIES, POWER PANELS & CCTV CAMERAS, FIRE ALARM DEVICE RELOCATIONS & REPLACEMENTS AS PER 2008 NEC & NFPA 72(SEPTA STATION)

  21. PermitElectrical

    Permit 300376 · COMPLETED

    INSTALL OF:(10)EX LTS,(5)LT FIX'S,(3)DOOR CONT'S,(2)VAR MESSAGE SIGNS,(25)SPKRS,(8)CCTV CAMERAS,(1)TELE,NEW FA (42)DEVICES,NEW PWR/COMM WIRING,NEW KRS WILL BE INSTALLED IN EXISTING DISTRIB PNLS OR EXIST CIRCUITS MOD (5 CRKS) AS PER 2008 NEC/NFPA-72(CC DIST)

  22. PermitSuppression

    Permit 263916 · COMPLETED

    DRY STANDPIPE INSTALLATION PER PLAN AND CALS.

Where this comes from

Methodology & freshness

This report was assembled Jul 25, 2026, 8:26 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.