Commercial property report

825 Walnut St

20,400 sqftCMX5built 1969

Property at a glanceTheater

Individual owner on record

2026 assessment
$963K OPA value, not a listing price
2027 published assessment
$963K Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $963,000. It is not yet the billed-year tax basis.

$0$500K$1.0M$963K2004200820122016202020242027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record69 events · exact dates, newest first
  1. CertificationEmergency and Standby Power Systems Certification
  2. CertificationSprinkler Certification
  3. CertificationEmergency and Standby Power Systems Certification
  4. CertificationSprinkler Certification
  5. PermitAddition and/or Alteration
  6. CertificationEmergency and Standby Power Systems Certification
  7. CertificationSprinkler Certification
  8. PermitAddition and/or Alteration
  9. CertificationFire Alarm Certification
  10. InspectionL&I investigation
  11. CertificationSprinkler Certification
  12. InspectionL&I investigation
  13. InspectionL&I investigation
  14. InspectionL&I investigation
  15. InspectionL&I investigation
  16. CertificationFire Alarm Certification
  17. L&I violationFAIL OBTAIN LICENSE (Obtain the license identified in the notice)
  18. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  19. L&I violationFDC LOCKING CAPS
  20. L&I violationACCEPTANCE CRITERIA & REPORTS
  21. L&I violationPERIODIC TESTING
  22. InspectionL&I investigation
  23. CertificationSprinkler Certification
  24. CertificationFire Alarm Certification
  25. PermitZoning
  26. InspectionCI INSP
  27. L&I violationEXIT SIGNS REQUIRED
  28. L&I violationEXIT SIGN ILLUMINATION
  29. InspectionCI INSP
  30. AppealRB_LIRB
  31. PermitAlteration
  32. PermitAlteration
  33. InspectionBP_BLDG
  34. PermitMajor alteration
  35. L&I violationPENALTY- NO BLDG PERM INFO
  36. L&I violationUNAPPROVED MAT'L OR ASSEM
  37. L&I violationTEMP CONST-COMPLY BLDG CODE
  38. InspectionBP_BLDG
  39. PermitAlteration
  40. PermitSign
  41. PermitZoning/use
  42. PermitAlteration
  43. InspectionBC INSP (likely: building-code inspection)
  44. PermitAlteration
  45. L&I violationSPECIAL ASSEMBLY OCC LO
  46. InspectionBC INSP (likely: building-code inspection)
  47. PermitElectrical
  48. InspectionPRECOURT (likely: pre-court compliance inspection)
  49. InspectionCI INSP
  50. InspectionCI INSP
  51. InspectionCI INSP
  52. InspectionCI INSP
  53. InspectionCI INSP
  54. InspectionCI INSP
  55. PermitMajor alteration
  56. L&I violationBLDG PERMIT REQUIRED
  57. L&I violationPERMZ- OR REMOVE ADVERTISING
  58. L&I violationPERM Z- NEW USE
  59. L&I violationPERMB- FLAT WALL SIGN
  60. L&I violationPENALTY- NO BLDG PERM INFO
  61. L&I violationPROSECUTION INFO
  62. InspectionSIGN
  63. PermitElectrical
  64. PermitAlteration
  65. InspectionCI INSP
  66. PermitSuppression
  67. InspectionCI INSP
  68. InspectionCI INSP
  69. LicenseWALNUT STREET THEATRE CORP: Food Establishment, Retail Permanent Location business license initially issued

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $963,000. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 771747000
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Theater, recorded in the City's commercial category. The public record and owner trail follow.

What it is
Theater Amuse Theatre Masonry
Owner
Individual owner on record Individual name redacted
$ / sq ft
$47 below the $151 median for 7,668 commercial parcels citywide
Corridor
Market East city commercial corridor
Interior area
20,400 sqft
Lot size
3,529 sqft
Built
1969
Zoning
CMX5

Block context

800 block of Walnut St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 827-31 Walnut St  ·  815-23 Walnut St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
WALNUT STREET THEATRE CORPActive

Food Establishment, Retail Permanent Location · Initial issue date Apr 8, 2004 · Filed expiration Apr 30, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 69 dated rows
  1. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2026-009119 · Certified

    Expires 2027-03-30

  2. CertificationSprinkler Certification

    Certification BC-2026-020125 · Certified

    Expires 2027-03-24

  3. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-009867 · Certified

    Expires 2026-04-14

  4. CertificationSprinkler Certification

    Certification BC-2025-008116 · Certified

    Expires 2026-03-24

  5. PermitAddition and/or Alteration

    Permit EP-2024-004696 · Completed

    INSTALL A 100 AMP BREAKER IN THE EXISTING SWITCHGEAR, INSTALL A 100 AMP PANEL & FEEDER. INSTALL LIGHTS NORMAL & EMERGENCY, SWITCHES & LIGHTING CONTROLLERS. INSTALL RECEPTACLES & FLOOR BOXES. PROVIDE POWER FOR THE LIFT CONTROLLER. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. * THE 100 AMP BREKER INSTALLATION / MODIFICATION WILL REQUIRE A FIELD EVALUATION & APPROVAL BY A CERTIFIED TESTING LAB.

  6. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-015918 · Certified

    Expires 2025-05-22

  7. CertificationSprinkler Certification

    Certification BC-2024-019556 · Certified

    Expires 2025-05-07

  8. PermitAddition and/or Alteration

    Permit CP-2024-000817 · Completed

    FOR EXTERIOR FACADE REPAIRS AND LEVEL I INTERIOR ALTERATIONS AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC AND PHC APPROVAL. SEPARATE PERMITS REQUIRED FOR M.E.P. WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. **ASBESTOS ABATEMENT REQUIRED** [AMENDMENT 7/15/2024 FOR CHANGES TO THE INSTALLED QUANTITY OF THEATER FIXED SEATING AND FOR CHANGES TO THE AV PLATFORM AS PER APPROVED AMENDED PLANS.] [AMENDMENT 2/18/2025 FOR FOUNDATION WORK AT THE EXISTING ORCHESTRA PIT IN ASSOCIATION WITH A LIFT REPLACEMENT AS PER APPROVED AMENDED PLANS.]

  9. CertificationFire Alarm Certification

    Certification BC-2024-007443 · Certified

    Expires 2025-03-21

  10. InvestigationL&I investigation

    Case CF-2023-022109 · PASSED

    The cited inspection visit was marked passed.

  11. CertificationSprinkler Certification

    Certification BC-2023-023971 · Certified

    Expires 2024-11-17

  12. InvestigationL&I investigation

    Case CF-2023-022109 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  13. InvestigationL&I investigation

    Case CF-2023-022109 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  14. InvestigationL&I investigation

    Case CF-2023-022109 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  15. InvestigationL&I investigation

    Case CF-2023-022109 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. CertificationFire Alarm Certification

    Certification BC-2023-009678 · Certified

    Expires 2024-03-23

  17. ViolationFAIL OBTAIN LICENSE (Obtain the license identified in the notice)

    Case CF-2023-022109 · Violation VI-2023-016638 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  18. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2023-022109 · Violation VI-2023-016636 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  19. ViolationFDC LOCKING CAPS

    Case CF-2023-022109 · Violation VI-2023-016637 · Code F-912.4.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  20. ViolationACCEPTANCE CRITERIA & REPORTS

    Case CF-2023-022109 · Violation VI-2023-016639 · Code F-807.3 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  21. ViolationPERIODIC TESTING

    Case CF-2023-022109 · Violation VI-2023-016635 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. InvestigationL&I investigation

    Case CF-2023-022109 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  23. CertificationSprinkler Certification

    Certification BC-2021-003542 · Certified

    Expires 2023-04-18

  24. CertificationFire Alarm Certification

    Certification BC-2023-009677 · Certified

    Expires 2023-03-23

  25. PermitZoning

    Permit 1051350 · COMPLETED

    FOR THE CREATION OF A UNITY OF USE TO CREATE ONE (1) LOT FOR ZONING PURPOSES TO BE KNOWN AS 815-23 WALNUT ST. WITH RESPECTIVE COVENANTS, AGREEMENTS AND EASEMENTS TO BE RECORDED BY DEED TO BIND CURRENT AND FUTURE OWNERS OF THE CONTIGUOUS LOTS KNOWN AS 825 WALNUT ST, 827-31 WALNUT ST AND 815R WALNUT ST. TO PRESERVE THE UNITY OF USE AND THE LEGALITY OF THE ENTIRE PROJECT THAT STEMS FROM SINGLE ZONING LOT TREATMENT. PRIOR TO ISSUANCE OF CERTIFICATION OF OCCUPANCY, PROOF RECORDATION OF EASEMENTS, AGREEMENTS AND RESTRICTIVE COVENANTS MUST BE SUPPLIED. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. SEE PERMIT # 962730 FOR PLANS.

  26. InvestigationCI INSP

    Case 697826 · PASSED

    The cited inspection visit was marked passed.

  27. ViolationEXIT SIGNS REQUIRED

    Case 697826 · Violation 5124623 · Code FC-13-1007.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. ViolationEXIT SIGN ILLUMINATION

    Case 697826 · Violation 5124624 · Code FC-13-1007.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. InvestigationCI INSP

    Case 697826 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  30. AppealRB_LIRB

    Appeal 32618 · OPEN · City affirmed

    THE SUBJECT PROPERTY IS THE WALNUT STREET THEATRE, WHICH HAS OPERATED A CONCESSION BAR AT THIS LOCATION FOR A SUBSTANTIAL PERIOD OF TIME.CONSISTENT WITH OTHER THEATRES AND SIMILAR VENUE FACILITIES,NO HAND WASHING SINK EXISTS WITHIN THE BAR

  31. PermitAlteration

    Permit 936965 · COMPLETED

    RECAULK JOINT SEALEANTS AT COPING STONES AS PER HISTORIC COMMISSION APPROVAL STAMPED ON 12/21/2018

  32. PermitAlteration

    Permit 493037 · COMPLETED

    APPLY WATER PROOF COATING TO AREAS OF TERRA COTTA TO MATCH EXISTING MASONRY PER ATTACHED PHOTO

  33. InvestigationBP_BLDG

    Case 395117 · PASSED

    The cited inspection visit was marked passed.

  34. PermitMajor alteration

    Permit 491644 · COMPLETED

    CONSTRUCTION OF TEMPORARY SIDEWALK SHELTER PLATFORM AT THE WALNUT STREET FRONTAGE PER PLANS APPROVED BY THE STREETS DEPARTMENT AND PHILADELPHIA HISTORICAL COMMISSION.

  35. ViolationPENALTY- NO BLDG PERM INFO

    Case 395117 · Violation 2885331 · Code A-901.13/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  36. ViolationUNAPPROVED MAT'L OR ASSEM

    Case 395117 · Violation 2885330 · Code A-203.3/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  37. ViolationTEMP CONST-COMPLY BLDG CODE

    Case 395117 · Violation 2885332 · Code PM-310.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  38. InvestigationBP_BLDG

    Case 395117 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  39. PermitAlteration

    Permit 482505 · COMPLETED

    CLEAN TERRA COTTA USING MILD DETERGENT AND LOW PRESSURE WATER.. REPAIR TERRA COTTA USING COMPROCO MIMIC REPAIR MORTAR. PATCH POINT MORTAR JOINTS AS REQUIRED.

  40. PermitSign

    Permit 454023 · COMPLETED

    REMOVING ONE FLAT WALL SIGN AND RECTING ONE ILLUMINATED FLATWALL SIGN

  41. PermitZoning/use

    Permit 428784 · COMPLETED

    REMOVE AND REPLACE SIGN.***CUST WAS MADE AWARE THAT THIS IS TO BE PROCESSED UP FRONT BUT INSISTED THAT SHE SEES AN EXAMINER***

  42. PermitAlteration

    Permit 418542 · COMPLETED

    REMOVE OLD MARBLE PATCHES AT FRONT STEPS AND COLUMNS AND REPAIR MORTAR TO SPECIFICATIONS AS OUTLINED AND APPROVED BY THE PHILADELPHIA HISTORICAL COMMISSION.

  43. InvestigationBC INSP (likely: building-code inspection)

    Case 293258 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  44. PermitAlteration

    Permit 361205 · COMPLETED

    REPLACEMENT OF EXIT & VESTIBULE DOORS OF A THEATRE AS PER PHILADELPHIA HISTORICAL COMMISSION REQUIREMENTS. EXIT DOORS ARE OF LIKE SIZE AND HARDWARE TO EXISTING. CALL THE INSPECTOR PRIOR TO STARTING WORK.

  45. ViolationSPECIAL ASSEMBLY OCC LO

    Case 293258 · Violation 2186981 · Code 09-703.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  46. InvestigationBC INSP (likely: building-code inspection)

    Case 293258 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  47. PermitElectrical

    Permit 282842 · COMPLETED

    ADD (6) ELECTRIC DOOR LOCKS CONNECTED TO EXISTING FIRE ALARM SYSTEM. FIRE ALARM - DOORS UNLOCK, AC POWER LESS - DOORS UNLOCK AS PER NFPA-72

  48. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 92666 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  49. InvestigationCI INSP

    Case 92666 · CLOSED

    City marked the record closed; open the case for the closing reason.

  50. InvestigationCI INSP

    Case 92666 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  51. InvestigationCI INSP

    Case 92666 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  52. InvestigationCI INSP

    Case 92666 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  53. InvestigationCI INSP

    Case 92666 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  54. InvestigationCI INSP

    Case 92666 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  55. PermitMajor alteration

    Permit 218688 · COMPLETED

    RECONFIGURATION OF AUDITORIUM SEATING TO ACCOMODATE 14 NEW SEATS AS PER PLANS.

  56. ViolationBLDG PERMIT REQUIRED

    Case 180000 · Violation 1106171 · Code A-501.1/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  57. ViolationPERMZ- OR REMOVE ADVERTISING

    Case 180000 · Violation 1106170 · Code A-301.1/66 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  58. ViolationPERM Z- NEW USE

    Case 180000 · Violation 1106169 · Code A-301.1/65 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  59. ViolationPERMB- FLAT WALL SIGN

    Case 180000 · Violation 1106168 · Code A-301.1/21 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  60. ViolationPENALTY- NO BLDG PERM INFO

    Case 180000 · Violation 1106173 · Code A-901.13/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  61. ViolationPROSECUTION INFO

    Case 180000 · Violation 1106172 · Code A-503.1/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  62. InvestigationSIGN

    Case 180000 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  63. PermitElectrical

    Permit 171361 · COMPLETED

    REMOVE OLD DIMMER RACK AND REPLACE WITH NEW.

  64. PermitAlteration

    Permit 160315 · COMPLETED

    HIGH PRESSURE CLEANING OF MARBLE FACADE REPAIR OF MORTAR JOINTS AND APPLICATION OF FWEATHER SEAL. RE PAINT WINDOWS. REMOVE SEALANT BETWEEN 2ND AND 3RD FLOOR STUCCO AND 1ST FLOOR MARBLE LEDGE THEN RE SEAL HIGH PRESSURE CLEAN THEN PATCH AND SEAL 2ND FLOOR STUCCO WORK TO BE DONE AT THE DIRECTION OF THE HISTORICAL COMMISSION

  65. InvestigationCI INSP

    Case 92655 · NONE

  66. PermitSuppression

    Permit 46111 · COMPLETED

    INSTALLATION OF BACKFLOW PREVENTER IN PUMP ROOM OF THE WALNUT THEATRE AS PER PLANS.

  67. InvestigationCI INSP

    Case 92655 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  68. InvestigationCI INSP

    Case 92666 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  69. License issue eventWALNUT STREET THEATRE CORP: Food Establishment, Retail Permanent Location business license initially issued

    License 199706 · Active

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 6:07 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)