Property report

900-22 Race St

440,122 sqftCMX4built 1923

Property at a glanceCommercial

Individual owner on record

2026 assessment
$17M OPA value, not a listing price
2027 published assessment
$17M Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar
Open L&I record

1 violation row marked OPEN in 1 active case

The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.

Open City history ↗
Case CF-2026-050646

Facades

IN VIOLATION

Opened May 12, 2026 · Latest inspection FAILED · Jun 30, 2026

  • FacadesPM15-315.2

OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $17,264,000. It is not yet the billed-year tax basis.

$0$10M$20M$17M2004200820122016202020242027
Property assessmentAssessmentL&I violationPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record171 events · exact dates, newest first
  1. InspectionL&I investigation
  2. PermitShelter/Platform
  3. L&I violationFACADES
  4. InspectionL&I investigation
  5. PermitAddition and/or Alterations
  6. PermitAddition and/or Alterations
  7. PermitAddition and/or Alteration
  8. PermitAddition and/or Alteration
  9. PermitAddition and/or Alterations
  10. PermitAddition and/or Alterations
  11. PermitAddition and/or Alteration
  12. PermitAddition and/or Alteration
  13. PermitAddition and/or Alterations
  14. PermitAddition and/or Alteration
  15. PermitInterior Non-Load-Bearing Wall Demo.
  16. PermitAddition and/or Alteration
  17. PermitShelter/Platform
  18. PermitAddition and/or Alteration
  19. PermitAddition and/or Alterations
  20. InspectionL&I investigation
  21. InspectionL&I investigation
  22. CertificationFacade Report
  23. InspectionL&I investigation
  24. L&I violationFACADES
  25. InspectionAIU INSP
  26. InspectionAIU INSP
  27. L&I violationFAILURE TO SUBMIT FACADE REPT
  28. InspectionAIU INSP
  29. PermitSign
  30. InspectionCI INSP
  31. PermitZoning/use
  32. PermitPlumbing
  33. InspectionCI INSP
  34. PermitElectrical
  35. PermitSuppression
  36. L&I violationFIRE ESCAPE REPORT
  37. InspectionCI INSP
  38. PermitMechanical
  39. PermitSuppression
  40. PermitPlumbing
  41. PermitMajor alteration
  42. InspectionCI INSP
  43. InspectionCI INSP
  44. L&I violationFIRE DEPT CONNECT REP DAM CAPS
  45. PermitMajor alteration
  46. PermitMajor alteration
  47. InspectionCI INSP
  48. L&I violationFIRE DEPT CONNECT REP DAM CAPS
  49. L&I violationVIOL C&I MESSAGE
  50. InspectionCI INSP
  51. InspectionPRECOURT (likely: pre-court compliance inspection)
  52. PermitMechanical
  53. PermitElectrical
  54. PermitSuppression
  55. InspectionPRECOURT (likely: pre-court compliance inspection)
  56. PermitPlumbing
  57. PermitSuppression
  58. PermitMajor alteration
  59. PermitSign
  60. InspectionBP_BLDG
  61. PermitZoning/use
  62. InspectionCI INSP
  63. InspectionBP_BLDG
  64. PermitElectrical
  65. PermitElectrical
  66. PermitPlumbing
  67. InspectionCI INSP
  68. PermitMajor alteration
  69. InspectionCI INSP
  70. L&I violationPENALTY- NO BLDG PERM INFO
  71. L&I violationPERMB- EXTEND FIRE SUPP SYS
  72. InspectionBP_BLDG
  73. PermitMajor alteration
  74. PermitSuppression
  75. L&I violationINSURANCE - POST CERT
  76. L&I violationINSURANCE - POST CERT
  77. PermitPlumbing
  78. InspectionCI INSP
  79. L&I violationCVN-UNLIC GENERAL CONTR
  80. PermitMajor alteration
  81. L&I violationHIRISE-PAY HIRISE FEE
  82. L&I violationVIOL C&I MESSAGE
  83. InspectionCI INSP
  84. L&I violationFIRE DEPT CONNECT REP DAM CAPS
  85. InspectionCI INSP
  86. PermitMajor alteration
  87. PermitMajor alteration
  88. PermitOperations
  89. PermitSuppression
  90. PermitMajor alteration
  91. PermitElectrical
  92. PermitElectrical
  93. InspectionCI INSP
  94. InspectionCI INSP
  95. PermitElectrical
  96. PermitElectrical
  97. InspectionCI INSP
  98. L&I violationFIRE DEPT CONNECT REP DAM CAPS
  99. L&I violationFIRE-PULL STATION SIGNS
  100. L&I violationVIOL C&I MESSAGE
  101. L&I violationANNUAL CERT STANDBY/EMERG LITE
  102. InspectionCI INSP
  103. PermitMechanical
  104. LicenseVERIZON SERVICES ORGANIZATION: Dumpster License - Private Property L&I license filing marked inactive
  105. L&I violationVIOL C&I MESSAGE
  106. L&I violationFIRE PROT SYS MAINTENANCE
  107. InspectionCI INSP
  108. LicenseVERIZON SERVICES ORGANIZATION: High Rise L&I license filing marked inactive
  109. CertificationFacade Report
  110. LicenseVERIZON SERVICES ORGANIZATION: Dumpster License - Private Property L&I license filing initially issued
  111. InspectionCI HAZMAT
  112. InspectionCI INSP
  113. InspectionCI HAZMAT
  114. InspectionCI INSP
  115. L&I violationVIOL C&I MESSAGE
  116. L&I violationANNUAL CERT FIRE SUPP
  117. InspectionCI INSP
  118. LicenseVERIZON SERVICES ORGANIZATION: High Rise L&I license filing initially issued
  119. InspectionADMIN INSP (likely: administrative inspection)
  120. PermitPlumbing
  121. L&I violationFIRE/EVAC PLN-AVAIL EMPLOYEE
  122. L&I violationANNUAL CERT FIRE SUPP
  123. L&I violationVIOL C&I MESSAGE
  124. L&I violationOBTAIN PERMIT EXTEN SPRKLR SYS
  125. L&I violationHAZMAT-ID SIGNS REQ¿D
  126. L&I violationHAZMAT-LIC REQ¿D
  127. L&I violationEGRESS EXIT SIGNS REQ
  128. L&I violationSHELTER PLN-EMPLY TRNG
  129. L&I violationHAZMAT-WARNING SIGN
  130. L&I violationHIRISE-PAY HIRISE FEE
  131. InspectionCI HAZMAT
  132. InspectionCI HAZMAT
  133. L&I violationCOULD NOT ENTER
  134. L&I violationVIOL C&I MESSAGE
  135. InspectionCI HAZMAT
  136. InspectionCI HAZMAT
  137. InspectionCI HAZMAT
  138. InspectionBP_BLDG
  139. InspectionCI HAZMAT
  140. L&I violationPERMB- WK DONE W/O NOTIFY INSP
  141. InspectionBP_BLDG
  142. LicenseVERIZON PENNSYLVANIA INC (CHERYL HOUGHTON): Hazardous Materials L&I license filing initially issued
  143. InspectionCI HAZMAT
  144. PermitMechanical
  145. PermitZoning/use
  146. PermitMajor alteration
  147. L&I violationCOULD NOT ENTER
  148. L&I violationVIOL C&I MESSAGE
  149. InspectionCI HAZMAT
  150. PermitElectrical
  151. PermitSuppression
  152. PermitNew Construction
  153. PermitMechanical
  154. PermitMajor alteration
  155. PermitElectrical
  156. PermitMechanical
  157. PermitSuppression
  158. PermitPlumbing
  159. PermitMajor alteration
  160. PermitElectrical
  161. PermitMechanical
  162. LicenseBELL OF PENNA: Hazardous Materials L&I license filing marked inactive
  163. PermitMajor alteration
  164. PermitPlumbing
  165. PermitFast form building
  166. PermitAlteration
  167. PermitElectrical
  168. InspectionCI INSP
  169. InspectionCI INSP
  170. InspectionCI INSP
  171. LicenseBELL OF PENNA: Hazardous Materials L&I license filing initially issued

Verify the public record

$241,661/year estimated property tax

2026 taxable assessment $17,264,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $17,264,000. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 771618000
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

1 open violation

What it is
Commercial Pub Util 10-14 Sty Mason
Owner
Individual owner on record Individual name redacted
$ / sq ft
$39 below the $151 median for 7,668 commercial parcels citywide
Corridor
Chinatown city commercial corridor
Interior area
440,122 sqft
Lot size
57,600 sqft
Built
1923
Zoning
CMX4

Block context

900 block of Race St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 926-28 Race St  ·  926-28 Race St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 170 dated rows
  1. InvestigationL&I investigation

    Case CF-2026-050646 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  2. PermitShelter/Platform

    Permit GP-2026-001921 · Issued

    SHELTER PLATFORM PERMIT - Erection of a sidewalk shelter platform as per Engineered Plans. Streets Department permit is required for sidewalk closure prior to the start work.

  3. ViolationFACADES

    Case CF-2026-050646 · Violation VI-2026-030678 · Code PM15-315.2 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  4. InvestigationL&I investigation

    Case CF-2026-050646 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  5. PermitAddition and/or Alterations

    Permit MP-2024-000820 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  6. PermitAddition and/or Alterations

    Permit FP-2024-000188 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (52) sprinkler heads to accommodate interior alterations

  7. PermitAddition and/or Alteration

    Permit EP-2023-011804 · Completed

    INSTALL (2) 300 KVA TRANSFORMERS, (1) 30 KVA TRANSFORMER, (2) 1000 AMP PANEL BOARDS. INSTALL (4) 600 AMP OVERHEAD BUSS DUCT RUNS. INSTALL LIGHTS NORMAL & EMERGENCY, SWITCHES, SENSORS, RECEPTACLES IN THE NETWORKING ROOM. PROVIDE POWER FOR THE MECHANICAL & HVAC EQUIPMENT. PROVIDE POWER FOR THE UPS & NETWORK EQUIPMENT. INSTALL NEW VESDA FIRE DETECTION DEVICES & EQUIPMENT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.

  8. PermitAddition and/or Alteration

    Permit EP-2023-009703 · Completed

    Selective demo as needed. Furnish and install power for VSD replacements. Furnish and install power for general purpose panelboard as per 2017 NEC. Existing fire alarm

  9. PermitAddition and/or Alterations

    Permit MP-2023-004799 · Completed

    Mechanical work, including, installation of (2) split cooling units with associated piping (6) new registers/diffusers, new control valves and fans, for BAS upgrade, as per approved plans

  10. PermitAddition and/or Alterations

    Permit FP-2023-002699 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (4) sprinkler heads to accommodate interior alterations

  11. PermitAddition and/or Alteration

    Permit CP-2023-005154 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR ALTERATIONS TO AN EXISTING OFFICE (GROUP B) AS PER APPROVED PLANS. *2018 IEBC REVIEW*. SEPARATE PERMIT REQUIRED FOR MEP WORK

  12. PermitAddition and/or Alteration

    Permit CP-2023-006604 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING ATTACHED STRUCTURE. ALTERATIONS TO INCLUDE THE DEMO AND ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS AND DOCUMENTATION. ***************** SEPARATE PERMTIS TO BE OBTAINED FOR ALL OTHER WORK. ****************************************** AMENDMENT: AMENDMENT TO CHANGE THE TOTAL SF TO 2500 SF.

  13. PermitAddition and/or Alterations

    Permit FP-2023-002769 · Expired

    FOR AN ALTERATION TO AN EXISTING SPRINKLER SYSTEM. ** WORK TO INLCUDE THE RELOCATION OF SPRINKLER HEADS AS PER PLANS.**

  14. PermitAddition and/or Alteration

    Permit EP-2023-010999 · Completed

    Disconnect and remove or re-support existing lighting, receptacles, mechanical equipment power connections and branch & feeder wiring to accommodate removal of existing interior non-load bearing walls &ceilings on 2nd floor under general permit #GM-2023-008865. Provide temporary lighting and GFCI protected general receptacles from an on-site power source for use by contractors. Existing fire alarm system to remain operational. All temporary wiring to conform to 2017 NEC.

  15. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2023-008865 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  16. PermitAddition and/or Alteration

    Permit CP-2023-004341 · Expired

    FOR THE REPAIR AND MAINTENANCE OF FACADE TO AN EXISTING STRUCTURE. **A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 10.5 FEET (1/4TH OF HEIGHT OF BUILDING) OF THE BUILDING FACADE IN ACCORDANCE WITH SECTION 3306 OF THE 2018 IBC. FOR USE AS PREVIOUSLY APPROVED. AS PER APPROVED PLANS.

  17. PermitShelter/Platform

    Permit GP-2023-007058 · Expired

    FOR SIDEWALK SHELTER PLATFORM PER APPROVED PLANS.

  18. PermitAddition and/or Alteration

    Permit EP-2023-004168 · Completed

    Provide power, annunciation, and detection system wiring for suppression system replacement in the main electrical room as per APPROVED DRAWINGS-2016 NFPA-72,2018 PHILA FIRE CODE. -FP-2023-000181-

  19. PermitAddition and/or Alterations

    Permit FP-2023-000181 · Completed

    FOR THE REPLACEMENT OF EXISTING HALON SYSTEM IN EXISTING ELECTRICAL ROOM, ALL WORK TO BE DONE PER MANUFACTURER'S SPECIFICATION IN ACCORDANCE WITH NFPA 12A AND NFPA 2001 STANDARDS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  20. InvestigationL&I investigation

    Case 631807 · PASSED

    The cited inspection visit was marked passed.

  21. InvestigationL&I investigation

    Case CF-2021-002798 · PASSED

    The cited inspection visit was marked passed.

  22. CertificationFacade Report

    Certification BC-2021-001119 · Safe with Repair

    Expires 2026-04-18

  23. InvestigationL&I investigation

    Case CF-2021-002798 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  24. ViolationFACADES

    Case CF-2021-002798 · Violation VI-2021-002091 · Code PM15-315.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  25. InvestigationAIU INSP

    Case 631807 · CLOSED

    City marked the record closed; open the case for the closing reason.

  26. InvestigationAIU INSP

    Case 631807 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  27. ViolationFAILURE TO SUBMIT FACADE REPT

    Case 631807 · Violation 211948867 · Code PM-304.10/1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. InvestigationAIU INSP

    Case 631807 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  29. PermitSign

    Permit 836103 · COMPLETED

    REMOVAL AND REPLACEMENT OF TWO (2) DOUBLE-FACED, NON-ILLUMINATED, PROJECTING SIGNS AND ONE (1) NON-ILLUMINATED, WALL SIGN AND FOR THE INSTALLATION OF TWO (2) STATICALLY-ILLUMINATED, BUILDING IDENTIFICATION WALL SIGNS AS PER APPROVED PLANS. **SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL WORK**

  30. InvestigationCI INSP

    Case 604922 · PASSED

    The cited inspection visit was marked passed.

  31. PermitZoning/use

    Permit 822377 · COMPLETED

    TO REMOVE AND REPLACE TWO (2) DOUBLE-FACED, NON-ILLUMINATED, PROJECTING SIGNS AND ONE (1) NON-ILLUMINATED, WALL SIGN AND FOR THE INSTALLATION OF TWO (2) STATICALLY-ILLUMINATED, BUILDING IDENTIFICATION WALL SIGNS. SIZE AND LOCATION AS SHOW ON PLANS AND APPLICATION. ALL SIGNS ACCESSORY TO PREVIOUSLY APPROVED BUSINESS AND PROFESSIONAL OFFICES.

  32. PermitPlumbing

    Permit 821276 · COMPLETED

    ALTERATIONS: INTERIOR PLUMBING; (1) EJECTOR PUMP ON 1ST FL SINK OFF OF EXISTING PERMIT #805058- THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  33. InvestigationCI INSP

    Case 604922 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  34. PermitElectrical

    Permit 805435 · COMPLETED

    INSTALLATION OF NEW LIGHTING FIXTURES,NEW RECEPTACLES AND BRANCH CIRCUITRY,NEW ELECTRICAL PANEL, FEEDER, ADD BACKBOEXS, RACEWAYS, ABLING & DEVICE 60 DROPS PLENUM RATED CAT5 LOLNGEST RUN 150' AS PER 2008 NEC (CC DISTRICT)RELOCATE EXISTING FIRE ALARM DEVICE AND INSTALL SPEAKER, STROBES & BUSTER PANEL AS PER NFPA72

  35. PermitSuppression

    Permit 812646 · COMPLETED

    FOR THE INSTALLATION OF AUTOMATIC SPRINKLERS, USING THE EXISTING SYSTEM INSTALLED AS PER NFPA 13, WITHIN THE FIRST FLOOR OF AN EXISTING HIGH-RISE STRUCTURE USED AS OFFICES, AS PER PLANS; NO ALTERATIONS TO EXISTING MAIN, BACKFLOWS, ETC.

  36. ViolationFIRE ESCAPE REPORT

    Case 604922 · Violation 4488511 · Code FC-13-101115 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  37. InvestigationCI INSP

    Case 604922 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  38. PermitMechanical

    Permit 802913 · COMPLETED

    FOR ALTERATIONS TO AN EXISTING HVAC MECHANICAL SYSTEM TO INCLUDE VAV BOX INSTALATIONS, GRILLES/DIFFUSERS/REGISTERS, AND ASSOCIATED DUCTWORK.

  39. PermitSuppression

    Permit 808837 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  40. PermitPlumbing

    Permit 805058 · COMPLETED

    REPLACE 1 KITCHEN SINK INSTALL NEW SINK AS PER PHILADELPHIA 2004 PLUMBING CODE.

  41. PermitMajor alteration

    Permit 792905 · COMPLETED

    FOR INTERIOR LEVEL 2 ALTERATIONS TO EXISTING SPACE AS PER PLANS. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  42. InvestigationCI INSP

    Case 509676 · PASSED

    The cited inspection visit was marked passed.

  43. InvestigationCI INSP

    Case 509676 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  44. ViolationFIRE DEPT CONNECT REP DAM CAPS

    Case 509676 · Violation 3764909 · Code FC-901.6/12 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  45. PermitMajor alteration

    Permit 628430 · COMPLETED

    FOR EXTERIOR ALTERATIONS TO EXISTING FACADE INCLUDING, REPLACING AND REPOINTING OF SPALLED BRICK AND DETERIORATED MORTAR, REPAIRING AND REPLACING OF CERTAIN STEEL LINTELS, RESETTIG A DISPLACED CORNICE AND REPAIRING AND PAINTING OF METAL COPING AS PER APPROVED PLANS. NO CHANGE IN HEIGHT OR AREA, NO CHANGE IN OCCUPANCY CLASSIFICATION.

  46. PermitMajor alteration

    Permit 631457 · COMPLETED

    SIDEWALK SHELTER PLATFORM SCAFFOLD PROTECTION ON N HUTCHINSON STREET TO RACE STREET TO N 9TH STREET

  47. InvestigationCI INSP

    Case 479420 · PASSED

    The cited inspection visit was marked passed.

  48. ViolationFIRE DEPT CONNECT REP DAM CAPS

    Case 479420 · Violation 3552994 · Code FC-901.6/12 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  49. ViolationVIOL C&I MESSAGE

    Case 479420 · Violation 3552993 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  50. InvestigationCI INSP

    Case 479420 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  51. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 413815 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  52. PermitMechanical

    Permit 558951 · COMPLETED

    FOR THE INSTALLATION OF THIRTY-FIVE (35) REGISTERS/DIFFUSERS AND ASSOCIATED DUCT WORK PER APPROVED PLANS. ALL WORK ON THE 8TH AND 9TH FLOORS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION.

  53. PermitElectrical

    Permit 556880 · COMPLETED

    INSTALL 85-FLUORESCENT FIXTURES, 5-EXIST SIGNS, 8-SWITCHES, 26- RECEPTS & 2-FURNITURE WHIPS AS PER NEC 2008 (OFFICE SPACE)

  54. PermitSuppression

    Permit 560420 · EXPIRED

    WE WILL BE RELOCATING 26 SPRINKLERS IN THE GROUND FLOOR LOBBY OF VERIZON

  55. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 413815 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  56. PermitPlumbing

    Permit 557218 · COMPLETED

    8TH FLOOR PLUMBING ALTERATIONS - REMOVE/RELOCATE AN EXISTING BREAK ROOM SINK APPROXIMATELY 3'-0" AND FURNISH/INSTALL NEW SINK, FAUCET AND TANKLESS WATER HEATER

  57. PermitSuppression

    Permit 553990 · COMPLETED

    RELOCATE 13 SPRINKLERS ON 8TH AND 9TH FLOOR

  58. PermitMajor alteration

    Permit 542007 · COMPLETED

    INTERIOR OFFICE ALTERATIONS ON 8TH AND 9TH FLOORS - WORK INCLUDES REPLACEMENT OF FINISHES, CEILING TILES , INSTALLATION OF NEW WALLS FOR CONFERENCE/TEAM ROOMS, PANTRY RELOCATION, FLOOR RECONFIGURATIONS, MODIFICATIONS TO EXISTING DUCT WORK, LIGHTING AND SPRINKLER RECONFIGURATIONS. ADDITIONAL PERMITS REQ: ELECTRICAL, PLUMBING, HVAC, SPRINKLERS. NO CHANGE IN USE-OCCUPANCY.

  59. PermitSign

    Permit 517700 · COMPLETED

    FOR THE REMOVAL OF ONE (1) EXISTING FLATWALL SIGN (FRONTING RACE STREET); FOR THE ERECTION OF TWO (2) ACCESSORY, PROJECTING, DOUBLE FACED, STATICALLY-ILLUMINATED SIGNS); ONE ACCESSORY FLATWALL SIGN (FRONTING 9TH ST) TO REMAIN. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS.

  60. InvestigationBP_BLDG

    Case 413815 · CLOSED

    City marked the record closed; open the case for the closing reason.

  61. PermitZoning/use

    Permit 512319 · COMPLETED

    FOR THE REMOVAL OF ONE (1) EXISTING FLATWALL SIGN (FRONTING RACE STREET); FOR THE ERECTION OF TWO (2) ACCESSORY, PROJECTING, DOUBLE FACED, STATICALLY-ILLUMINATED SIGNS); ONE ACCESSORY FLATWALL SIGN (FRONTING 9TH ST) TO REMAIN. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS. ALL SIGNS ACCESSORY TO PREVIOUSLY APPROVED BUSINESS AND PROFESSIONAL OFFICES.

  62. InvestigationCI INSP

    Case 405491 · CLOSED

    City marked the record closed; open the case for the closing reason.

  63. InvestigationBP_BLDG

    Case 413815 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  64. PermitElectrical

    Permit 508947 · COMPLETED

    RELOCATE EXISTING SMOKE DETECTORS AND 10 HORN STROBES AS PER NFPA72 INSTALL NEW LIGHTING POWER DEVICES AND DEMO EXISTING SPACE AS PER 2008 NEC (CC DISTRICT)

  65. PermitElectrical

    Permit 508946 · COMPLETED

    RENOVATION OF OPEN SPACE TO ADD WORK STATIONS AND LIGHTING AS PER 2008 NEC (CC DISTRICT)

  66. PermitPlumbing

    Permit 513225 · COMPLETED

    INSTALL 2-WATER CLOSETS & 2-LAVATORIES (OFFICE BLDG)

  67. InvestigationCI INSP

    Case 405491 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  68. PermitMajor alteration

    Permit 507386 · COMPLETED

    FOR LEVEL II ALTERATIONS ON THE FIRST FLOOR OF AN EXISTING BUILDING TO PROVIDE ACCESSIBLITY IMPROVEMENTS TO EXISTING TOILET ROOM. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.

  69. InvestigationCI INSP

    Case 405607 · PASSED

    The cited inspection visit was marked passed.

  70. ViolationPENALTY- NO BLDG PERM INFO

    Case 413815 · Violation 3317685 · Code A-901.13/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  71. ViolationPERMB- EXTEND FIRE SUPP SYS

    Case 413815 · Violation 3317684 · Code A-301.1/28 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  72. InvestigationBP_BLDG

    Case 413815 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  73. PermitMajor alteration

    Permit 504530 · COMPLETED

    INTERIOR ALTERATIONS, AS PER PLANS

  74. PermitSuppression

    Permit 507311 · COMPLETED

    RELOCATE (11) SPRINKLERS

  75. ViolationINSURANCE - POST CERT

    Case 494205 · Violation 3429384 · Code A-302.8/32 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  76. ViolationINSURANCE - POST CERT

    Case 492187 · Violation 3017424 · Code A-302.8/32 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  77. PermitPlumbing

    Permit 506218 · COMPLETED

    ADD ONE KITCHE SINK TO THE 11TH FLOOR COFFEE STATION

  78. InvestigationCI INSP

    Case 405607 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  79. ViolationCVN-UNLIC GENERAL CONTR

    Case 482599 · Violation 2976302 · Code 9-1004 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  80. PermitMajor alteration

    Permit 494205 · COMPLETED

    LEVEL I INTERIOR ALTERATIONS TO REPAIR & ALTER AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE NEW WINDOWS, DOORS, SECURTY FENCES, WALL INFILL AND OFFICE SPACE RECONFIGURATION. EXTERIOR ALTERATIONS ALSO PART OF THIS PERMIT AS SHOWN IN APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL AND ELECTRICAL SYSTEMS.

  81. ViolationHIRISE-PAY HIRISE FEE

    Case 405491 · Violation 3075465 · Code FC-408.12/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  82. ViolationVIOL C&I MESSAGE

    Case 405491 · Violation 3075464 · Code A-000.0/10 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  83. InvestigationCI INSP

    Case 405491 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  84. ViolationFIRE DEPT CONNECT REP DAM CAPS

    Case 405607 · Violation 3003178 · Code FC-901.6/12 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  85. InvestigationCI INSP

    Case 405607 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  86. PermitMajor alteration

    Permit 492187 · COMPLETED

    INTERIOR ALTERATIONS FOR LOBBY RENOVATION AS PER PLANS.

  87. PermitMajor alteration

    Permit 482599 · COMPLETED

    REMOVAL OF MICROWAVE TOWERS FROM ROOF OF EXISTING BUILDING. WORK TO BE CORRDINATED WITH THE STREET DEPARTMENT CLOSURE PERMIT. OPERATIONAL PERMIT FOR BURNING AND CUTTING WILL BE REQUIRED.

  88. PermitOperations

    Permit 22513 · COMPLETED

    HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES 08/14/2014

  89. PermitSuppression

    Permit 479591 · COMPLETED

    RELOCATE 5 SPRINKLERS ON THE 2ND FLOOR OF THE TREASURY OFFICE AT VERIZON.

  90. PermitMajor alteration

    Permit 476885 · COMPLETED

    INT ALT AS PER PLANS

  91. PermitElectrical

    Permit 477447 · COMPLETED

    INSTALL 4-2X2 FIXTURES, 12-120 VOLT DUPLEX RECPT, RELOCATE 6-2X4 FIXTURES, INSTALL 4-WIREMOLD PLUG STRIPS, INSTALL 1-UNDER CARPET RACEWAY FOR CONFERENCE TABLE AS PER NEC 2008 (OFFICE BLDG)

  92. PermitElectrical

    Permit 469322 · COMPLETED

    REMOVE DEFECTIVE NETWORK CONTROL STATION AND ITS COMPATIBLE ANNUNCIATOR AND REPLACE WITH A NEW OXYX NETWORK CONTROL WORK STATION AND ITS COMPATIBLE ANNUCIATOR PER 2008 NEC & NFPA 72 (OFFICE SPACE)

  93. InvestigationCI INSP

    Case 344507 · PASSED

    The cited inspection visit was marked passed.

  94. InvestigationCI INSP

    Case 344507 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  95. PermitElectrical

    Permit 428403 · COMPLETED

    REPLACE FAULTY SOLENOID CONTROL MODULE ON 2ND FL REPLACE VESDA UNIT ON 10TH FLO WITH 4 SMOKES DETECTORS AND BASES REPLACE MONITOR MODULE FOR 10 FLOOR VESDA UNIT PER 2008 NEC & NFPA 72 (OFFICE SPACE)

  96. PermitElectrical

    Permit 428404 · COMPLETED

    REPLACE FAULTY MONITORING MODULE AND FLAME DETECTOR IN GENERATOR HOUSE PER 2008 NEC & NFPA 72(OFFICE SPACE)

  97. InvestigationCI INSP

    Case 338736 · PASSED

    The cited inspection visit was marked passed.

  98. ViolationFIRE DEPT CONNECT REP DAM CAPS

    Case 344507 · Violation 2673086 · Code FC-901.6/12 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  99. ViolationFIRE-PULL STATION SIGNS

    Case 344507 · Violation 2673087 · Code FC-907.4/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  100. ViolationVIOL C&I MESSAGE

    Case 344507 · Violation 2673085 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  101. ViolationANNUAL CERT STANDBY/EMERG LITE

    Case 344507 · Violation 2673088 · Code FC-915.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  102. InvestigationCI INSP

    Case 344507 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  103. PermitMechanical

    Permit 414515 · COMPLETED

    REPLACE EXISTING 600 TON CHILLER AND CIRCULATING PUMP-TELE DATA

  104. License terminal eventVERIZON SERVICES ORGANIZATION: Dumpster License - Private Property L&I license filing marked inactive

    License 542572 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  105. ViolationVIOL C&I MESSAGE

    Case 338736 · Violation 2504851 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  106. ViolationFIRE PROT SYS MAINTENANCE

    Case 338736 · Violation 2504852 · Code FC-901.7/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  107. InvestigationCI INSP

    Case 338736 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  108. License terminal eventVERIZON SERVICES ORGANIZATION: High Rise L&I license filing marked inactive

    License 487206 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  109. CertificationFacade Report

    Certification BC-2022-010788 · Safe with Repair

    Expires 2016-09-26

  110. License issue eventVERIZON SERVICES ORGANIZATION: Dumpster License - Private Property L&I license filing initially issued

    License 542572 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  111. InvestigationCI HAZMAT

    Case 206758 · PASSED

    The cited inspection visit was marked passed.

  112. InvestigationCI INSP

    Case 227251 · PASSED

    The cited inspection visit was marked passed.

  113. InvestigationCI HAZMAT

    Case 206758 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  114. InvestigationCI INSP

    Case 227251 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  115. ViolationVIOL C&I MESSAGE

    Case 227251 · Violation 1705938 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  116. ViolationANNUAL CERT FIRE SUPP

    Case 227251 · Violation 1705937 · Code FC-914.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  117. InvestigationCI INSP

    Case 227251 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  118. License issue eventVERIZON SERVICES ORGANIZATION: High Rise L&I license filing initially issued

    License 487206 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  119. InvestigationADMIN INSP (likely: administrative inspection)

    Case 171232 · PASSED

    Legacy inspection shorthand; the title alone does not state what condition was examined. The cited inspection visit was marked passed.

  120. PermitPlumbing

    Permit 231903 · COMPLETED

    EXCAVATION AND REPLACEMENT- BLOCKED 8" STORM TRAP. POSSIBLE LATERAL OR MAIN WORK IF EITHER IS COLLAPSED AND REPLACE 8" SEWER LATERAL AND TRAP FROM SEWER INTO BUILDING

  121. ViolationFIRE/EVAC PLN-AVAIL EMPLOYEE

    Case 206758 · Violation 1705928 · Code FC-404.5/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  122. ViolationANNUAL CERT FIRE SUPP

    Case 206758 · Violation 1705926 · Code FC-914.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  123. ViolationVIOL C&I MESSAGE

    Case 206758 · Violation 1705925 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  124. ViolationOBTAIN PERMIT EXTEN SPRKLR SYS

    Case 206758 · Violation 1705936 · Code FC-901.4/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  125. ViolationHAZMAT-ID SIGNS REQ¿D

    Case 206758 · Violation 1705935 · Code FC-2703.5/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  126. ViolationHAZMAT-LIC REQ¿D

    Case 206758 · Violation 1705934 · Code FC-2701.5/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  127. ViolationEGRESS EXIT SIGNS REQ

    Case 206758 · Violation 1705931 · Code FC-1011.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  128. ViolationSHELTER PLN-EMPLY TRNG

    Case 206758 · Violation 1705930 · Code FC-409.4/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  129. ViolationHAZMAT-WARNING SIGN

    Case 206758 · Violation 1705929 · Code FC-407.3/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  130. ViolationHIRISE-PAY HIRISE FEE

    Case 206758 · Violation 1705927 · Code FC-408.12/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  131. InvestigationCI HAZMAT

    Case 202089 · PASSED

    The cited inspection visit was marked passed.

  132. InvestigationCI HAZMAT

    Case 206758 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  133. ViolationCOULD NOT ENTER

    Case 202089 · Violation 1353876 · Code A.CNE.000 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  134. ViolationVIOL C&I MESSAGE

    Case 202089 · Violation 1353875 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  135. InvestigationCI HAZMAT

    Case 202089 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  136. InvestigationCI HAZMAT

    Case 171232 · CLOSED

    City marked the record closed; open the case for the closing reason.

  137. InvestigationBP_BLDG

    Case 187787 · PASSED

    The cited inspection visit was marked passed.

  138. InvestigationCI HAZMAT

    Case 171232 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  139. ViolationPERMB- WK DONE W/O NOTIFY INSP

    Case 187787 · Violation 1187099 · Code A-302.11/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  140. InvestigationBP_BLDG

    Case 187787 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  141. License issue eventVERIZON PENNSYLVANIA INC (CHERYL HOUGHTON): Hazardous Materials L&I license filing initially issued

    License 460069 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  142. InvestigationCI HAZMAT

    Case 171232 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  143. PermitMechanical

    Permit 169058 · COMPLETED

    INSTALL CHILLER AND NEW COOLING TOWER

  144. PermitZoning/use

    Permit 166884 · COMPLETED

    ADDING A COOLING TOWER TO A ROOF OF AN OFFICE BUILDING

  145. PermitMajor alteration

    Permit 159867 · COMPLETED

    SUPPLEMENTAL STEEL BEING ADDED TO AN EXISTING COOLING TOWER DURNAAGE STEEL SYSTEM ONLY. ZONING APPROVAL REQUIRED FOR APPLIANCE SIZE. A SEPARATE BUILDING PERMIT IS REQUIRED FOR APPLIANCE INSTALLATION.

  146. ViolationCOULD NOT ENTER

    Case 171232 · Violation 1312882 · Code A.CNE.000 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  147. ViolationVIOL C&I MESSAGE

    Case 171232 · Violation 1312881 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  148. InvestigationCI HAZMAT

    Case 171232 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  149. PermitElectrical

    Permit 156898 · COMPLETED

    RENOVATION OF EXISTING FLOOR, WORK CONSISTS OF RECONFIGURED LIGHTING AND POWER AS PER 2005 NEC , ALL FIRE ALARM IS TO REMAIN AS IS(CC DISTRICT)

  150. PermitSuppression

    Permit 160726 · COMPLETED

    RELOCATE 150 SPRINKLER HEADS - 5TH FLOOR CUSTOMER CARE

  151. PermitNew Construction

    Permit 155858 · Expired

    Provide power to new chillers and cooling tower as per drawings(3 sets) Provide power to chillers and cooling towers

  152. PermitMechanical

    Permit 151326 · COMPLETED

    INTERIOR RENOVATIONS, INSTALLATIONS OF NEW MECHANICALS, DUCT WORK, DIFFUSERS, AS PER SUBMITTED PLANS.

  153. PermitMajor alteration

    Permit 151011 · COMPLETED

    INTERIOR RENOVATIONS, FIT OUT, UPGRADES IN EXISTING SPACE, AS PER SUBMITTED PLANS.

  154. PermitElectrical

    Permit 132115 · COMPLETED

    RENOVATIONS OF EXISTING FLOOR, WORK CONSIST OF RECONFIGURED LIGHTING AND POWER. ALL FIRE ALARM IS REMAIN AS IS. (CC DIST)

  155. PermitMechanical

    Permit 127031 · COMPLETED

    HVAC, INCLUDING DUCTWORK AS PER PLANS

  156. PermitSuppression

    Permit 129369 · COMPLETED

    RELOCATE 305 SPRINKLER HEADS - 2ND FLOOR

  157. PermitPlumbing

    Permit 128275 · COMPLETED

    INSTALLATION OF SANITARY WASTE AND VENT PIPING. INSTALLATION OF WATER SUPPLY PIPING, INSTALLATION OF FXTS: 9 WC, 7 LAVS, 1 SINK. DEMO OF EXISTING TOILET ROOM.

  158. PermitMajor alteration

    Permit 126164 · COMPLETED

    INTERIOR ALTERATIONS AS PER PLANS

  159. PermitElectrical

    Permit 115244 · COMPLETED

    LIGHTS, SWITCHES, RECEPTS AS PER 2005 NEC AND PULL STATIONS, STROBES, AND PANELS AS PER NFPA72 (CCDIST)

  160. PermitMechanical

    Permit 117108 · COMPLETED

    HVAC

  161. License terminal eventBELL OF PENNA: Hazardous Materials L&I license filing marked inactive

    License 284547 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  162. PermitMajor alteration

    Permit 113548 · COMPLETED

    INTERIOR ALTERATIONS, ADD NEW INTERIOR WALLS, CONSTRUCT THREE OFFICES, TWO CLOSETS, ROOM FOR UPS UNIT AS PER PLANS.

  163. PermitPlumbing

    Permit 117134 · COMPLETED

    NEW DRINKING FOUNTAIN AND ASSOCIATED PIPING TO CONFORM WITH RENOVATION WORK

  164. PermitFast form building

    Permit 115291 · COMPLETED

  165. PermitAlteration

    Permit 110852 · COMPLETED

    INSTALLATION OF NEW "CARLISLE ROOFING SYSTEM"

  166. PermitElectrical

    Permit 47912 · COMPLETED

    NEW ELECTRICAL WIRING FOR NEW A/C UNITS

  167. InvestigationCI INSP

    Case 91854 · PASSED

    The cited inspection visit was marked passed.

  168. InvestigationCI INSP

    Case 91854 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  169. InvestigationCI INSP

    Case 91854 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  170. License issue eventBELL OF PENNA: Hazardous Materials L&I license filing initially issued

    License 284547 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 8:29 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)