Commercial property report

903 Market St

CMX5built 1958

Property at a glanceCommercial

Pr Gallery I Limited Partnership

2026 assessment
$1.4M OPA value, not a listing price
2027 published assessment
$1.4M Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $1,378,400. It is not yet the billed-year tax basis.

$0$1.0M$2.0M$1.4M201420172020202320262027
Property assessmentAssessmentL&I violationPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record241 events · exact dates, newest first
  1. LicenseDistrict Shop (District Shop): Food Preparing and Serving business license marked inactive
  2. PermitChange of Use
  3. InspectionL&I investigation
  4. L&I violationBENCHMARKING LATE
  5. InspectionL&I investigation
  6. LicensePacific Receivable Inc.: Food Establishment, Retail Permanent Location business license marked inactive
  7. PermitChange of Use
  8. LicenseStarbucks Corporation (Starbucks Coffee #60509): Food Establishment, Retail Permanent Location business license marked inactive
  9. PermitChange of Use
  10. LicenseDistrict Shop (District Shop): Food Preparing and Serving business license initially issued
  11. LicenseKNEAD MORE DOUGH LLC: Food Preparing and Serving business license marked inactive
  12. PermitCertificate of Occupancy (CO) (may inclu…
  13. PermitChange of Use
  14. LicenseSTAR RETAIL LLC (PHILLY FRESH FRIES): Food Establishment, Retail Permanent Location business license marked expired
  15. PermitSign
  16. PermitAddition and/or Alteration
  17. PermitAddition and/or Alteration
  18. PermitAddition and/or Alteration
  19. PermitChange of Use
  20. InspectionL&I investigation
  21. L&I violationRENDERING EQUIPMENT INOPERABLE
  22. InspectionL&I investigation
  23. PermitAddition and/or Alteration
  24. LicenseTHE JUICE SQUAD: Food Preparing and Serving business license marked closed
  25. LicenseBLUE LEMON LLC (POTATO CORNER): Food Preparing and Serving business license marked inactive
  26. PermitAddition and/or Alteration
  27. PermitAddition and/or Alteration
  28. PermitAlterations
  29. PermitAddition and/or Alterations
  30. PermitAlterations
  31. PermitAddition and/or Alteration
  32. PermitAddition and/or Alteration
  33. PermitAddition and/or Alteration
  34. LicensePacific Receivable Inc.: Food Establishment, Retail Permanent Location business license initially issued
  35. PermitAddition and/or Alteration
  36. PermitAddition and/or Alteration
  37. PermitCertificate of Occupancy (CO) (may inclu…
  38. PermitAddition and/or Alteration
  39. PermitCertificate of Occupancy (CO) (may inclu…
  40. PermitCertificate of Occupancy (CO) (may inclu…
  41. PermitAddition and/or Alteration
  42. PermitAddition and/or Alterations
  43. PermitAddition and/or Alterations
  44. PermitAddition and/or Alteration
  45. LicenseSTAR RETAIL LLC (PHILLY FRESH FRIES): Food Establishment, Retail Permanent Location business license initially issued
  46. LicensePhiladelphia Restaurant Holdings LLC: Food Preparing and Serving business license initially issued
  47. PermitAddition and/or Alteration
  48. PermitCertificate of Occupancy (CO) (may inclu…
  49. PermitAddition and/or Alteration
  50. PermitChange of Use
  51. PermitCertificate of Occupancy (CO) (may inclu…
  52. PermitAddition and/or Alteration
  53. PermitAddition and/or Alterations
  54. PermitRough-In
  55. PermitAddition and/or Alterations
  56. PermitSign
  57. PermitAddition and/or Alteration
  58. PermitAddition and/or Alteration
  59. PermitAlterations
  60. PermitCertificate of Occupancy (CO) (may inclu…
  61. PermitChange of Use
  62. PermitAddition and/or Alteration
  63. PermitAddition and/or Alteration
  64. PermitChange of Use
  65. PermitAddition and/or Alteration
  66. PermitCertificate of Occupancy (CO) (may inclu…
  67. PermitCertificate of Occupancy (CO) (may inclu…
  68. PermitAddition and/or Alteration
  69. PermitSign
  70. PermitCertificate of Occupancy (CO) (may inclu…
  71. PermitSigns (Accessory / Non-Accessory)
  72. PermitSign
  73. PermitAddition and/or Alteration
  74. PermitAddition and/or Alteration
  75. PermitNew construction, addition, GFA change
  76. PermitAddition and/or Alterations
  77. PermitAddition and/or Alterations
  78. PermitSigns (Accessory / Non-Accessory)
  79. PermitAddition and/or Alteration
  80. PermitAlterations
  81. PermitChange of Use
  82. PermitCertificate of Occupancy (CO) (may inclu…
  83. PermitAddition and/or Alterations
  84. PermitAddition and/or Alteration
  85. PermitAlterations
  86. PermitAddition and/or Alterations
  87. PermitAddition and/or Alteration
  88. PermitAddition and/or Alteration
  89. PermitCertificate of Occupancy (CO) (may inclu…
  90. PermitCertificate of Occupancy (CO) (may inclu…
  91. PermitInterior Non-Load-Bearing Wall Demo.
  92. PermitSign
  93. PermitSigns (Accessory / Non-Accessory)
  94. PermitNew Construction
  95. LicenseStarbucks Corporation (Starbucks Coffee #60509): Food Establishment, Retail Permanent Location business license initially issued
  96. PermitNew Construction
  97. LicenseAPS GALLERY FOODS, LLC: Food Preparing and Serving business license marked inactive
  98. PermitSign
  99. PermitSigns (Accessory / Non-Accessory)
  100. PermitAddition and/or Alterations
  101. PermitSign
  102. LicenseBLUE LEMON LLC (POTATO CORNER): Food Preparing and Serving business license initially issued
  103. PermitAddition and/or Alteration
  104. PermitSigns (Accessory / Non-Accessory)
  105. PermitAlterations
  106. PermitAddition and/or Alterations
  107. PermitNew Construction
  108. PermitAlterations
  109. PermitAddition and/or Alteration
  110. PermitSign
  111. PermitAmend for conversion
  112. PermitAddition and/or Alteration
  113. PermitNew Construction
  114. PermitNew Construction
  115. PermitNew Construction
  116. PermitAddition and/or Alteration
  117. PermitAddition and/or Alteration
  118. PermitNew Construction
  119. PermitAddition and/or Alteration
  120. PermitSigns (Accessory / Non-Accessory)
  121. PermitNew Construction
  122. PermitAlterations
  123. PermitSign
  124. PermitAmend for conversion
  125. PermitAmend for conversion
  126. PermitNew Construction
  127. PermitNew Construction
  128. PermitSign
  129. PermitNew Construction
  130. PermitAddition and/or Alteration
  131. PermitNew Construction
  132. PermitNew Construction
  133. PermitRough-In
  134. PermitNew Construction
  135. PermitNew Construction
  136. PermitRough-In
  137. PermitAddition and/or Alteration
  138. PermitRough-In
  139. PermitAmend for conversion
  140. PermitAlterations
  141. PermitCertificate of Occupancy (CO) (may inclu…
  142. PermitSign
  143. PermitAddition and/or Alteration
  144. PermitNew Construction
  145. PermitNew Construction
  146. PermitRough-In
  147. PermitRough-In
  148. PermitNew Construction
  149. PermitNew Construction
  150. PermitAlterations
  151. PermitAlterations
  152. PermitSign
  153. PermitSign
  154. PermitAmend for conversion
  155. PermitAddition and/or Alteration
  156. PermitNew Construction
  157. PermitNew Construction
  158. PermitSign
  159. PermitNew Construction
  160. PermitNew Construction
  161. PermitNew Construction
  162. PermitNew Construction
  163. PermitNew Construction
  164. PermitNew Construction
  165. PermitNew Construction
  166. PermitAlterations
  167. PermitAddition and/or Alteration
  168. PermitNew Construction
  169. PermitAlterations
  170. PermitSign
  171. PermitNew Construction
  172. PermitAddition and/or Alteration
  173. PermitRough-In
  174. PermitNew Construction
  175. PermitAddition and/or Alteration
  176. PermitNew Construction
  177. PermitNew Construction
  178. PermitAddition and/or Alteration
  179. PermitAddition and/or Alteration
  180. PermitNew Construction
  181. PermitNew Construction
  182. PermitAddition and/or Alteration
  183. PermitAddition and/or Alteration
  184. PermitNew Construction
  185. LicenseRound One Entertainment, Inc.: Food Preparing and Serving (30+ SEATS) business license initially issued
  186. LicenseKNEAD MORE DOUGH LLC: Food Preparing and Serving business license initially issued
  187. PermitNew Construction
  188. PermitAddition and/or Alteration
  189. PermitNew Construction
  190. PermitNew Construction
  191. PermitAlterations
  192. PermitSign
  193. PermitSign
  194. PermitSign
  195. PermitSign
  196. PermitNew Construction
  197. PermitNew Construction
  198. LicenseTHE JUICE SQUAD: Food Preparing and Serving business license initially issued
  199. PermitNew Construction
  200. PermitNew Construction
  201. PermitNew Construction
  202. PermitNew Construction
  203. PermitNew Construction
  204. PermitAddition and/or Alteration
  205. PermitNew Construction
  206. PermitAddition and/or Alteration
  207. PermitSign
  208. PermitNew Construction
  209. LicenseCity Winery Philadelphia, LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
  210. PermitNew Construction
  211. PermitNew Construction
  212. PermitNew Construction
  213. PermitNew Construction
  214. PermitNew Construction
  215. PermitNew Construction
  216. LicenseAPS GALLERY FOODS, LLC: Food Preparing and Serving business license initially issued
  217. PermitNew Construction
  218. PermitNew Construction
  219. PermitNew Construction
  220. PermitNew Construction
  221. PermitNew Construction
  222. PermitNew Construction
  223. PermitNew Construction
  224. PermitAddition and/or Alteration
  225. PermitNew Construction
  226. PermitAddition and/or Alteration
  227. PermitNew Construction
  228. PermitNew Construction
  229. PermitAddition and/or Alteration
  230. PermitNew Construction
  231. PermitAddition and/or Alteration
  232. PermitNew Construction
  233. PermitNew Construction
  234. PermitNew Construction
  235. PermitNew Construction
  236. PermitNew Construction
  237. PermitZoning
  238. InspectionCI INSP
  239. L&I violationFIRE PROT SYS MAINTENANCE
  240. L&I violationVIOL C&I MESSAGE
  241. InspectionCI INSP

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,378,400. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 781209800
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

What it is
Commercial Sub Str/Off 1 Sty Masonry
Owner
Pr Gallery I Limited Partnership
Corridor
Market East city commercial corridor
Lot size
10,706 sqft
Built
1958
Zoning
CMX5

Recorded owner

Who's behind it

Pr Gallery I Limited Partnership · corporate / LLC owner

• Owns 4 properties across Philadelphia under this name, assessed at $55M combined
• Tax bills mail to 401 Wilshire Boulevard Suite 700, Santa Monica CA, 90401 — outside Philadelphia

Block context

900 block of Market St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 901 Market St  ·  901s Market St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
District Shop (District Shop)Inactive

Food Preparing and Serving · Initial issue date May 7, 2024 · Terminal license date Jul 5, 2026

Pacific Receivable Inc.Inactive

Food Establishment, Retail Permanent Location · Initial issue date Jun 29, 2022 · Terminal license date Aug 27, 2025

STAR RETAIL LLC (PHILLY FRESH FRIES)Expired

Food Establishment, Retail Permanent Location · Initial issue date Mar 6, 2022 · Terminal license date Mar 5, 2023

Philadelphia Restaurant Holdings LLCActive

Food Preparing and Serving · Initial issue date Mar 4, 2022 · Filed expiration Mar 3, 2027

Starbucks Corporation (Starbucks Coffee #60509)Inactive

Food Establishment, Retail Permanent Location · Initial issue date Nov 10, 2020 · Terminal license date Jan 8, 2025

BLUE LEMON LLC (POTATO CORNER)Inactive

Food Preparing and Serving · Initial issue date Sep 14, 2020 · Terminal license date Nov 12, 2022

Round One Entertainment, Inc.Active

Food Preparing and Serving (30+ SEATS) · Initial issue date Dec 19, 2019 · Filed expiration Dec 18, 2026

KNEAD MORE DOUGH LLCInactive

Food Preparing and Serving · Initial issue date Dec 17, 2019 · Terminal license date Feb 14, 2024

THE JUICE SQUADClosed

Food Preparing and Serving · Initial issue date Nov 15, 2019 · Terminal license date Nov 14, 2022

City Winery Philadelphia, LLCActive

Food Preparing and Serving (30+ SEATS) · Initial issue date Sep 17, 2019 · Filed expiration Sep 16, 2026

APS GALLERY FOODS, LLCInactive

Food Preparing and Serving · Initial issue date Aug 22, 2019 · Terminal license date Oct 20, 2020

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 241 dated rows
  1. License terminal eventDistrict Shop (District Shop): Food Preparing and Serving business license marked inactive

    License 950842 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  2. PermitChange of Use

    Permit ZP-2026-006518 · Issued

    Retail Sales - Consumer Goods

  3. InvestigationL&I investigation

    Case CF-2026-001799 · PASSED

    The cited inspection visit was marked passed.

  4. ViolationBENCHMARKING LATE

    Case CF-2026-001799 · Violation VI-2026-001040 · Code 9-3402(2) · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  5. InvestigationL&I investigation

    Case CF-2026-001799 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  6. License terminal eventPacific Receivable Inc.: Food Establishment, Retail Permanent Location business license marked inactive

    License 899712 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  7. PermitChange of Use

    Permit ZP-2025-007471 · Issued

    Assembly and Entertainment

  8. License terminal eventStarbucks Corporation (Starbucks Coffee #60509): Food Establishment, Retail Permanent Location business license marked inactive

    License 855317 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  9. PermitChange of Use

    Permit ZP-2024-005240 · Issued

    Assembly and Entertainment

  10. License issue eventDistrict Shop (District Shop): Food Preparing and Serving business license initially issued

    License 950842 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  11. License terminal eventKNEAD MORE DOUGH LLC: Food Preparing and Serving business license marked inactive

    License 831813 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  12. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2023-003087 · Expired

    Certificate of occupancy only for Unit C-114 as Assembly and Entertainment.

  13. PermitChange of Use

    Permit ZP-2023-003497 · Issued

    Assembly and Entertainment

  14. License terminal eventSTAR RETAIL LLC (PHILLY FRESH FRIES): Food Establishment, Retail Permanent Location business license marked expired

    License 889073 · Expired

    License event. Registration does not prove present operation or storefront occupancy.

  15. PermitSign

    Permit GP-2023-000718 · Expired

    FOR THE INSTALLATION OF ONE (1) INTERIOR FLAT WALL SIGN ACCESSORY TO TAKEOUT RESTAURANT. INSTALLATION TO BE DONE PER APPROVED PLANS SEALED BY A PROFESSIONAL ENGINEER LICENSED BY THE COMMONWEALTH OF PENNSYLVANIA. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  16. PermitAddition and/or Alteration

    Permit CP-2023-000704 · Completed

    FOR LEVEL 2 ALTERATIONS FOR FIT-OUT OF TENENT SPACE AS PER PLANS.

  17. PermitAddition and/or Alteration

    Permit CP-2023-000677 · Completed

    FOR A LEVEL I INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE LOCATED AT THE CONCOURSE LEVEL OF AN EXISTING STRUCTURE. ALTERATIONS LIMITED TO FINISHES UPGRADE AND FURNISHINGSTHROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  18. PermitAddition and/or Alteration

    Permit EP-2023-000572 · Completed

    Installation of 20 2x2 light fixtures throughout store. Adding LED light with switch for display, Installation of 2 8 inch lights in changing room area. Adding 3 Emergency lights and installing light and outlet in new bathroom according to 2017 NEC

  19. PermitChange of Use

    Permit ZP-2022-012895 · Issued

    Assembly and Entertainment

  20. InvestigationL&I investigation

    Case CF-2022-118214 · PASSED

    The cited inspection visit was marked passed.

  21. ViolationRENDERING EQUIPMENT INOPERABLE

    Case CF-2022-118214 · Violation VI-2022-088557 · Code F-106.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. InvestigationL&I investigation

    Case CF-2022-118214 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  23. PermitAddition and/or Alteration

    Permit CP-2022-006199 · Completed

    **Event to run from 11/19/2022 to 5/13/2023, 9AM-8PM only; must amend permit to extend duration of event.** For Level II Alterations within an existing Group M occupancy to be used as a temporary Group A-3 occupancy within Space #1150 on the Street and Second levels in an existing attached mixed-use building with covered mall characteristics, as per plans; separate permits required for all MEP/FSP work; no structural work on this permit; building is currently sprinklered throughout in accordance with NFPA 13, with standpipes installed within the exit stairways in accordance with NFPA 14, and with a fire alarm system installed throughout in accordance with NFPA 72; if field conditions vary contact design engineer prior to the start of any work; compliance with Philadelphia Fire and Property Maintenance Codes required prior to occupancy; see AP#875098 for zoning/use approval; no signs on this permit.

  24. License terminal eventTHE JUICE SQUAD: Food Preparing and Serving business license marked closed

    License 829412 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  25. License terminal eventBLUE LEMON LLC (POTATO CORNER): Food Preparing and Serving business license marked inactive

    License 851271 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  26. PermitAddition and/or Alteration

    Permit EP-2022-011003 · Completed

    Electrical Permit for combo CP-2022-005799

  27. PermitAddition and/or Alteration

    Permit CP-2022-005799 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE (C 220) ON THE 2ND FLOOR LEVEL OF AN EXISTING STRUCTURE. FOR USE AS A MERCANTILE . ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING TO BE FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  28. PermitAlterations

    Permit PP-2022-015343 · Completed

    Supply and install 1 twenty gallon water heater, 1 water closet and 1 lavatory. Supply and install Cast Iron Vent and Sanitary Piping and Bring to Fixtures. Supply and install copper piping for water and bring to fixtures.

  29. PermitAddition and/or Alterations

    Permit MP-2022-005212 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2022-005544 FOR THE INSTALLATION OF ONE (1) FUEL GAS PIPING SYSTEM AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IFGC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK.

  30. PermitAlterations

    Permit PP-2022-014964 · Completed

    Replace two floor drains

  31. PermitAddition and/or Alteration

    Permit CP-2022-005544 · Completed

    FOR LEVEL I INTERIOR ALTERATIONS WITHOUT A CHANGE IN OCCUPANCY TO AN EXISTING TAKE-OUT RESTAURANT IN SPACE # C-005. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK.

  32. PermitAddition and/or Alteration

    Permit CP-2022-004692 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO INSTALL A COVER OVER EXISTING KIOSK K2A IN AN EXISTING ENCLOSED MALL AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW*

  33. PermitAddition and/or Alteration

    Permit CP-2022-003863 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY )TO AN EXISTING SPACE(UNIT #172). FOR THE ADDITION OF A NEW RESTROOM. ALTERATIONS TO INCLUDE INSTALLATION OF NEW WALL PARTITIONS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT AS PER APPROVED PLANS. ALL WORK TO BE DONE PER APPROVED PLANS.** IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK**IEBC 2018**EXISTING BUILDING IS FULLY SPRINKLERED** SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK**

  34. License issue eventPacific Receivable Inc.: Food Establishment, Retail Permanent Location business license initially issued

    License 899712 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  35. PermitAddition and/or Alteration

    Permit CP-2022-003164 · Completed

    FOR THE ERECTION A CANAOPY STRUCTURE OVER EXISTING KIOSK WITHIN EXISTING MALL. SEPARATE PERMITS REQUIRED FOR ANY OTHER WORK.

  36. PermitAddition and/or Alteration

    Permit EP-2022-005907 · Completed

    EZ Electric Permit: Installation of an electric strike and security keypad for new door only.

  37. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2022-004562 · Issued

    FOR A CERTIFICATE OF OCCUPANCY FOR RETAIL SALES (GROUP M) IN EXISTING TENANT SPACE 2090. NO ALTERATIONS WORK UNDER THIS PERMIT.

  38. PermitAddition and/or Alteration

    Permit CP-2022-003000 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO AN EXISTING RETAIL SPACE ON LEVEL 2 OF AN EXISTING INDOOR MALL BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW*

  39. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2022-004535 · Completed

    CERTIFICATE OF OCCUPANCY FOR A TEMPORARY EVENT (JUNE 16, 2022 TO JULY 31, 2022) IN SPACE 1150 WITHIN THE FIRST AND SECOND FLOOR LEVEL OF AN EXISTING INTERIOR MALL FACILITY AS PER APPROVED PLANS. LAWFUL OCCUPANCY SIGNS TO BE ISSUED AS PART OF THIS PERMIT. NO PERMANENT CONSTRUCTION AUTHORIZED UNDER THIS PERMIT. *2018 IEBC REVIEW*

  40. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2022-003373 · Issued

    FOR A CERTIFICATE OF OCCUPANCY FOR RETAIL SALES OF WEARING APPAREL & ACCESSORIES (GROUP M) IN EXISTING TENANT SPACE 1025. NO ALTERATIONS WORK UNDER THIS PERMIT.

  41. PermitAddition and/or Alteration

    Permit EP-2022-002726 · Completed

    Supply (1) fire alarm booster panel, (1) smoke detector, (1) monitor module and (2) audio visual devices as per 2016 NFPA 72.

  42. PermitAddition and/or Alterations

    Permit MP-2022-001200 · Completed

    FOR THE INSTALLATION OF A NEW HVAC SYSTEMS, ASSOCIATED DUCT WORK, VAV, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION

  43. PermitAddition and/or Alterations

    Permit FP-2022-000720 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (11) EXISTING SPRINKLER HEADS IN SPACE CO40 (CP-2022-000177)

  44. PermitAddition and/or Alteration

    Permit EP-2022-001938 · Completed

    Provide a 100 amp 480v feeder from existing panelboard, (1) 100 amp 480 volt panelboard, (1) 30 KVA transformer, (1) 100 amp 208 volt panelboard. Provide new receptacles and lighting as per 2017 NEC

  45. License issue eventSTAR RETAIL LLC (PHILLY FRESH FRIES): Food Establishment, Retail Permanent Location business license initially issued

    License 889073 · Expired

    License event. Registration does not prove present operation or storefront occupancy.

  46. License issue eventPhiladelphia Restaurant Holdings LLC: Food Preparing and Serving business license initially issued

    License 888978 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  47. PermitAddition and/or Alteration

    Permit CP-2022-000177 · Completed

    AMENDMENT: FOR THE AMENDMENT OF CP-2022-000177 TO DOCUMENT CHANGE IN LAYOUT AS SHOWN PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ORIGINAL: FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE (INTERIOR FITOUT) FOR A RETAIL SPACE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  48. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-013228 · Completed

    FOR A CERTIFICATE OF OCCUPANCY FOR RETAIL SALES IN SUITE 1150 AS PART OF AN EXISTING SHOPPING CENTER. NO ALTERATIONS APPROVED ON THIS PERMIT. BUILDING SHALL COMPLY WITH THE PHILADELPHIA PROPERTY MAINTENANCE AND FIRE CODES PRIOR TO OCCUPANCY. SEPARATE PERMITS REQUIRED FOR ALTERATIONS.

  49. PermitAddition and/or Alteration

    Permit EP-2021-014112 · Completed

    no new wiring unit being moved from one location to other no additional wiring existing power at new location kios is being moved from one location to the other as a whole unit exiting power is at new location as per 2017 nec

  50. PermitChange of Use

    Permit ZP-2021-014533 · Issued

    Retail Sales - Wearing Apparel and Accessories

  51. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-012386 · Issued

    FOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY (RETAIL SALES OF WEARING APPAREL & ACCESSORIES - GROUP M USE & OCCUPANCY CLASSIFICATION) FOR EXISTING TENANT SPACE C-114. (IEBC 2018) **NO ALTERATIONS WORK UNDER THIS PERMIT WORKSCOPE.**

  52. PermitAddition and/or Alteration

    Permit EP-2021-011257 · Completed

    Install (74) lights, (7) receptacles, (27) fire alarm devices (2) breakers, and (1) Panel Relocate (2) chandeliers and (1) lighting relay panel as per 2017 NEC and NFPA 72

  53. PermitAddition and/or Alterations

    Permit MP-2021-006300 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  54. PermitRough-In

    Permit EP-2021-012224 · Completed

    ROUGH-IN PERMIT FOR- EP-2021-011257 (CP-2021-003943)-NO EQUIPMENT REPLACEMENT AS PART OF THIS ROUGH-IN

  55. PermitAddition and/or Alterations

    Permit FP-2021-003003 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (81) sprinkler heads at the Fashion District Mall (CP-2021-003943)

  56. PermitSign

    Permit GP-2021-010859 · Completed

    FOR INSTALLATION OF AN INTERNALLY-ILLUMINATED FLATWALL SIGN AT INTERIOR ASSEMBLY AREA, TO INCLUDE FASTENER INSTALLATION. SIZE AND LOCATION AS PER PLANS. **SEPARATE PERMIT TO BE REQUIRED FOR ELECTRICAL WORK.**

  57. PermitAddition and/or Alteration

    Permit EP-2021-011330 · Completed

    Install new kiosk with low voltage subpanel within kiosk hardwired utilizing existing electrical connection in mall. ALLW WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  58. PermitAddition and/or Alteration

    Permit CP-2021-006014 · Completed

    LEVEL II INTERIOR ALTERATIONS TO INSTALL A KIOSK (K2a) WITHIN AN EXISTING COVERED MALL BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK**

  59. PermitAlterations

    Permit PP-2021-018370 · Completed

    INSATLL 4" WD

  60. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-009395 · Completed

    FOR CERTIFICATE OF OCCUPANCY TO SPACE C-220 FOR THE USE OF ASSEMBLY AND ENTERTAINMENT ( LESS THAN 50 PEOPLE) AS PART OF EXISTING STRUCTURE **NO WORK UNDER THIS PERMIT WORKSCOPE.**

  61. PermitChange of Use

    Permit ZP-2021-012148 · Issued

    Personal Services; Retail Sales - Wearing Apparel and Accessories

  62. PermitAddition and/or Alteration

    Permit CP-2021-003943 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING MALL BY EXTENDING COMMONS AREAS BY REDUCING EXISTING TENANT SPACES WITH THE ERECTION OF PARTITION WALLS, STRUCTURAL WORK AND THE INSTALLATION OF FINISHES/FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  63. PermitAddition and/or Alteration

    Permit EP-2021-010348 · Completed

    Add (2) 208V 30A circuits for new hot wells as per 2017 nec

  64. PermitChange of Use

    Permit ZP-2021-011585 · Issued

    Retail Sales - Consumer Goods

  65. PermitAddition and/or Alteration

    Permit CP-2021-005571 · Completed

    FOR INTERIOR ALTERATIONS TO SPACE C025 AT CONCOURSE LEVEL OF AN EXISTING STRUCTURE, TO INCLUDE NEW PREP TABLES AND COUNTER SPACE, PER APPROVED PLANS. FIT OUT OF SPACE APPROVED UNDER PERMIT #967274.

  66. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-008413 · Issued

    FOR THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR A MERCANTILE OCCUPANCY.

  67. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-008471 · Issued

    FOR CERTIFICATE OF OCCUPANCY TO AN EXISTING TENANT SPACE C-172. (IEBC 2018) **NO WORK UNDER THIS PERMIT WORKSCOPE.**

  68. PermitAddition and/or Alteration

    Permit CP-2021-005007 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A MERCANTILE OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMIT TO BE OBTAINED FOR ALL OTHER WORK.

  69. PermitSign

    Permit GP-2021-008402 · Completed

    For the erection of two (2) accessory, statically illuminated projection signs onto the North and South sides of a marquee projecting out from the N 11th Street facade of an existing attached structure (Fashion District of Philadelphia) as per approved plans.

  70. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-005733 · Issued

    FOR CERTIFICATE OF OCCUPANCY TO AN EXISTING TENANT SPACE C-168. (IEBC 2018) **NO WORK UNDER THIS PERMIT WORKSCOPE.**

  71. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2021-006373 · Completed

    For the erection of two (2) accessory, statically illuminated projection signs onto the North and South sides of a marquee projecting out from the N 11th Street facade of an existing attached structure (Fashion District of Philadelphia), size and location as shown on plan/application.

  72. PermitSign

    Permit GP-2021-004080 · Completed

    FOR THE INSTALLATION OF FIVE WALL SIGNS (SIGNS A AND B) AND TWO PROJECTING SIGNS (SIGN C) PER APPROVED PLANS.

  73. PermitAddition and/or Alteration

    Permit CP-2021-002267 · Completed

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXPAND EXISTING LOADING AREA ALONG FILBERT STREET ON THE GROUND FLOOR LEVEL OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  74. PermitAddition and/or Alteration

    Permit EP-2021-005156 · Completed

    Install 1 pre amp, 1 volume controller, 65 speakers and 1 rack station (low voltage) AS PER NEC 2017

  75. PermitNew construction, addition, GFA change

    Permit ZP-2021-002318 · Completed

    FOR PARTIAL DEMOLITION OF EXTERIOR WALL OF AN EXISTING STRUCTURE TO ACCOMMODATE TRASH STORAGE.

  76. PermitAddition and/or Alterations

    Permit FP-2021-001364 · Completed

    Relocate (1) Sprinkler Head at Starbucks

  77. PermitAddition and/or Alterations

    Permit MP-2021-001220 · Completed

    For interior level 2 alterations for retail store interior fit out from 'white box' condition with all associated interior architectural walls and finishes and associated related MEP work including new rooftop and interior units. ELECTRICAL: Provide 1600 amp disconnect from existing 4000 amp MSB. Install electrical panels, transformers, UPS, lighting, exit/emergency lights, receptacles, telecommunications wiring as per 2017 NEC. Install fire alarm as per 2016 NFPA 72.

  78. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-008817 · Completed

    FOR THE ERECTION OF FIVE (5) ACCESSORY STATIC INTERNALLY ILLUMINATED WALL SIGNS AND TWO (2) ACCESSORY STATIC INTERNALLY ILLUMINATED PROJECTING SIGNS. SIZES AND LOCATIONS AS SHOWN ON PLANS.

  79. PermitAddition and/or Alteration

    Permit EP-2021-001895 · Completed

    For interior level 2 alterations for retail store interior fit out from 'white box' condition with all associated interior architectural walls and finishes and associated related MEP work including new rooftop and interior units. ELECTRICAL: Provide 1600 amp disconnect from existing 4000 amp MSB. Install electrical panels, transformers, UPS, lighting, exit/emergency lights, receptacles, telecommunications wiring as per 2017 NEC. Install fire alarm as per 2016 NFPA 72.

  80. PermitAlterations

    Permit PP-2021-003337 · Completed

    Above ceiling and in wall sanitary and domestic water rough in. Installl of new plumbing fixtures along with drinking fountain.

  81. PermitChange of Use

    Permit ZP-2021-002923 · Issued

    Retail Sales - Wearing Apparel and Accessories

  82. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-002074 · Completed

    FOR CO IN SPACE# C162. NO ALTERATIONS UNDER THIS PERMIT.

  83. PermitAddition and/or Alterations

    Permit FP-2021-000761 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE EXISTING (140) SPRINKLER HEADS AS PER NEW TEANANT CEILINGS STREET AND 2ND LEVEL (CP-2020-006487)

  84. PermitAddition and/or Alteration

    Permit CP-2020-006487 · Completed

    For interior level 2 alterations for retail store interior fit out from 'white box' condition with all associated interior architectural walls and finishes and associated related MEP work including new rooftop and interior units. ELECTRICAL: Provide 1600 amp disconnect from existing 4000 amp MSB. Install electrical panels, transformers, UPS, lighting, exit/emergency lights, receptacles, telecommunications wiring as per 2017 NEC. Install fire alarm as per 2016 NFPA 72. AMENDMENT (5/10/2021) amended the scope around the long runs of the escalator from balustrade to full height glazing panels as per plans.

  85. PermitAlterations

    Permit PP-2021-003755 · Completed

    For prescriptive alterations to install a Group A-2 tenant (Starbucks) within a kiosk at Space K01 and associated Group B tenant (remote workspace) on the Concourse level of the Fashion District of Philadelphia, as per plans; see sub-permits for associated MEP work; building is fully sprinklered throughout as per NFPA 13; see AP#875098 for use registration permit.

  86. PermitAddition and/or Alterations

    Permit MP-2021-001419 · Completed

    For prescriptive alterations to install a Group A-2 tenant (Starbucks) within a kiosk at Space K01 and associated Group B tenant (remote workspace) on the Concourse level of the Fashion District of Philadelphia, as per plans; see sub-permits for associated MEP work; building is fully sprinklered throughout as per NFPA 13; see AP#875098 for use registration permit.

  87. PermitAddition and/or Alteration

    Permit EP-2021-002186 · Completed

    For prescriptive alterations to install a Group A-2 tenant (Starbucks) within a kiosk at Space K01 and associated Group B tenant (remote workspace) on the Concourse level of the Fashion District of Philadelphia, as per plans; see sub-permits for associated MEP work; building is fully sprinklered throughout as per NFPA 13; see AP#875098 for use registration permit.

  88. PermitAddition and/or Alteration

    Permit CP-2020-006558 · Completed

    For prescriptive alterations to install a Group A-2 tenant (Starbucks) within a kiosk at Space K01 and associated Group B tenant (remote workspace) on the Concourse level of the Fashion District of Philadelphia, as per plans; see sub-permits for associated MEP work; building is fully sprinklered throughout as per NFPA 13; see AP#875098 for use registration permit.

  89. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2021-000604 · Completed

    FOR A CERTIFICATE OF OCCUPANCY FOR A MERCANTILE IN TENANT SPACE C-164 ON THE CONCOURSE LEVEL OF AN EXISTING STRUCTURE. NO ALTERATIONS APPROVED ON THIS PERMIT. BUILDING SHALL COMPLY WITH THE PHILADELPHIA PROPERTY MAINTENANCE AND FIRE CODES PRIOR TO OCCUPANCY. SEPARATE PERMITS REQUIRED FOR ALTERATIONS.

  90. PermitCertificate of Occupancy (CO) (may inclu…

    Permit AP-2020-013026 · Completed

    CO FOR ARDENE STORE IN SPACE NO. C190 (REFERENCE BUILDING PERMIT# 1055071 ISSUED WITH INCORRECT SPACE NO. 2005). NO ALTERATIONS TO BE PERFORMED UNDER THIS PERMIT.

  91. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2021-000767 · Expired

    EZ INTERIOR DEMOLITION- For the interior demolition on non-bearing partition wall and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans.

  92. PermitSign

    Permit GP-2020-010763 · Completed

    FOR THE ERECTION OF ONE (1) BLADE SIGN. SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLAN. FOR SIGN ACCESSORY TO PREVIOUSLY APPROVED WEARING APPAREL AND ACCESSORIES.

  93. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-009262 · Completed

    FOR ERECTION OF ONE (1) BLADE SIGN. SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLAN.

  94. PermitNew Construction

    Permit EP-2020-009465 · Completed

    Extend existing electrical power feed to the kiosk location and terminate as per 2017 nec

  95. License issue eventStarbucks Corporation (Starbucks Coffee #60509): Food Establishment, Retail Permanent Location business license initially issued

    License 855317 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  96. PermitNew Construction

    Permit CP-2020-005102 · Completed

    FOR THE ERECTION OF KIOSK AS PER APPROVED PLANS. NO SIGNS THIS PERMIT. **SEPARATE PERMITS REQUIRED FOR MEP WORK** **IEBC 2018** Space# K7A

  97. License terminal eventAPS GALLERY FOODS, LLC: Food Preparing and Serving business license marked inactive

    License 821723 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  98. PermitSign

    Permit GP-2020-007076 · Completed

    FOR THE INSTALLATION OF ONE (1) INTERIOR, FLATWALL SIGN, ACCESSORY TO CLOTHING STORE IN SPACE #1085, AS PER APPROVED PLANS.

  99. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-005817 · Issued

    FOR THE REFACING OF AN EXISTING FLAT WALL SIGN WITH STATIC ILLUMINATION (SIGN A)(SIZE AND LOCATION AS SHOWN ON PLANS)

  100. PermitAddition and/or Alterations

    Permit FP-2020-000991 · Expired

    INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 TO ACCOMMODATE A PORTION (SPACE #1180) OF AN EXISTING BUILDING TO INCLUDE 8" MAIN FIRE SERVICE LINE AND 8" DCV AMES 2000 SS BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  101. PermitSign

    Permit GP-2020-006393 · Completed

    FOR THE INSTALLATION OF ONE (1) STATICALLY ILLUMINATED FLATWALL SIGN. SIZE AND LOCATION AS SHOWN IN SCANNED PLAN. SIGN ACCESSORY TO A SPACE (KATE SPADE) IN AN EXISTING SHOPPING MALL. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  102. License issue eventBLUE LEMON LLC (POTATO CORNER): Food Preparing and Serving business license initially issued

    License 851271 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  103. PermitAddition and/or Alteration

    Permit EP-2020-005680 · Completed

    Tenant fitout fire alarm to landlord main system.ALL WORK TO BE DONE ACCORDING TO NICET-4 SEALED DRAWINGS AND CITY APPROVED DRAWINGS. 2016 NFPA-72.

  104. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-003618 · Completed

    FOR THE INSTALLATION OF ONE(1) STATICALLY ILLUMINATED FLATWALL SIGN. SIZE AND LOCATION AS SHOWN IN SCANNED PLAN. SIGN ACCESSORY TO A SPACE( KATE SPADE) IN AN EXISTING SHOPPING MALL.

  105. PermitAlterations

    Permit PP-2020-004756 · Completed

    Proposed work for Space K-07 (Potato Corner) to include water and waste line for following equipment: 1 three bay sink, 1 hand sink, 1 mop sink (other), 1 grease trap (other), 1 electric water heater, 2 indirect waste/hub drain

  106. PermitAddition and/or Alterations

    Permit FP-2020-000267 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. RELOCATE (40) EXISTING SPRINKLER HEADS FOR NEW RETAIL TENANT SPACE #2005 ARDENE , FASHION DISTRICT PHILADELPHIA 907-37 MARKET ST. (1055071)

  107. PermitNew Construction

    Permit MP-2020-000577 · Completed

    FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE AIR DEVISES, DIFFUSERS/REGISTERS/GRILLES, AND ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  108. PermitAlterations

    Permit PP-2020-003670 · Completed

    For Interior Plumbing of a existing mercantile space $2005 to furnish and install sanitary, sanitary vent and domestic water pipe to new fixtures [2] water closets, [2] lavatories, [1] water heater and [1] electric water cooler as per 2018 Philadelphia Plumbing Code.

  109. PermitAddition and/or Alteration

    Permit EP-2020-000937 · Completed

    Extension of existing building switchboard to accommodate a new service breaker & feeders for future tenant service. Elevator/Escalator associated power, Demarc conduit & conductors for future tenant, and misc storefront lighting and signage power and FIRE ALARM work per approved drawings. ALL TO BE DONE ACCORDING TO THE 2017 NEC AND 2016 NFPA-72.

  110. PermitSign

    Permit GP-2020-002030 · Completed

    FOR THE ERECTION OF ONE (1) PROJECTING SIGN AND ONE (1) STATICALLY ILLUMINATED WALL SIGN. SIZE AND LOCATION AS SHOWN IN PLAN. SIGNS ACCESSORY TO BUSINESS AND PROFESSIONAL OFFICE AT SPACE #3020 (INDUSTRIOUS) IN MALL WITH USES AS PREVIOUSLY APPROVED.

  111. PermitAmend for conversion

    Permit 1055493 · Issued

    TO AMEND PERMIT#1032930 FOR THE RELOCATION OF DIFFUSERS DUE TO INTERIOR LAYOUT MODIFICATION.

  112. PermitAddition and/or Alteration

    Permit 1041340 · Completed

    FOR PRESCRIPTIVE ALTERATIONS TO CREATE A GROUP M SHELL SPACE WITHIN SPACE #1180 (FUTURE "PRIMARK" STORE) ON THE STREET/2ND LEVELS OF THE FASHION DISTRICT OF PHILADELPHIA, INCLUDING REPLACEMENT OF EXTERIOR GLAZING (W/IN EXISTING OPENINGS), STRUCTURAL WORK FOR NEW FLOOR OPENINGS B/T STREET/2ND LEVELS OF TENANT SPACE (FOR NEW ESCALATORS/ELEVATORS), AND INCIDENTAL WORK AT TRUCK AND ROOF LEVELS, AS PER PLANS; SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK AND FIT-OUT/CO BY TENANT; BUILDING IS FULLY SPRINKLERED AS PER NFPA 13; NO SIGNS ON THIS PERMIT; SEPARATE PA L&I PERMITS REQUIRED FOR INSTALLATION OF ESCALATOR/ELEVATORS; SEE AP#730168 FOR ZONING APPROVAL OF ENCLOSURE OF STREET LEVEL ENTRANCE ON NEC 11TH & MARKET STREETS.

  113. PermitNew Construction

    Permit 1054157 · Completed

    Relocate (24) sprinkler heads to accommodate a new tenant layout.

  114. PermitNew Construction

    Permit 1054138 · Expired

    Relocate (16) sprinkler heads to accommodate a new tenant layout.

  115. PermitNew Construction

    Permit 1054146 · Completed

    Relocate (10) sprinkler heads to accommodate a new tenant layout.

  116. PermitAddition and/or Alteration

    Permit EP-2020-002657 · Completed

    Extend existing electrical service and install single-phase 100A 120/208V load center with branch circuit breakers. Install (14) 120V receptacles and provide power connections for lighting. Installation to comply with 2017 NEC.

  117. PermitAddition and/or Alteration

    Permit EP-2020-001804 · Completed

    STORE FIT OUT 400AMP FEEDER, PANEL-H, PANEL-A, 75KVA TRANSFORMER, WIRING LIGHTS, SWITCHES, RECEPTACLES, AND EQUIPMENT. AS PER THE 2017 NEC.

  118. PermitNew Construction

    Permit 1056004 · Completed

    INSTALL BUILDING SYSTEM FIRE ALARM TIED TO EXISTING SYSTEM PER DRAWINGS TEST AND CETRIFICATION BY SIEMENS

  119. PermitAddition and/or Alteration

    Permit 1055071 · Expired

    LEVEL II INTERIOR ALTERATION OF AN EXISTING MERCANTILE OCCUPANCY(SPACE#2005). ALTERATION TO INCLUDE NON LOAD BEARING PARTITIONS, FURNISHINGS, MILLWORK FIXTURES, NEW FINISHES, AND ALL OTHER WORK AS PER APPROVED PLANS. PLEASE REFER TO ORIGINAL ALTERATIONS PERMIT AP# 728409 FOR BASE BUILDING WORK AND AP# 978149 FOR LANDLORD WORK.**IEBC 2018 **SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.**AMENDED AS OF 12/29/2020 TO DOCUMENT A UNIT CHANGE TO UNIT# C190.**NO OTHER WORK APPROVED ON THE PERMIT**

  120. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-000189 · Completed

    FOR THE ERECTION OF ONE (1) PROJECTING SIGN AND ONE (1) STATICALLY ILLUMINATED WALL SIGN. SIZE AND LOCATION AS SHOWN IN APPLICATION AND PLAN.

  121. PermitNew Construction

    Permit 1045359 · Completed

    INSTALLATION OF A NEW MECHANICAL SYSTEM FOR AN EXISTING STRUCTURE (SPACE#165-STARBUCKS) TO INCLUDE A NEW HVAC SYSTEM, VAV BOXES,AIR HANDLERS, EXHAUST FAN, REGISTERS AND DIFFUSERS AND ALL ASSOCIATED DUCTWORK AS PER APPROVED PLANS.APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS REQUIRED FOR ANY OTHER ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK**

  122. PermitAlterations

    Permit 1052532 · Completed

    INSTALL 2 WATER CLOSETS, 3 LAVS, 2 FLOOR DRAINS, 2 MOP SINKS, 1 THREE COMP SINK, 7 FLOOR SINKS, 2 HAND SINKS, 1 PREP SINK, 3 PITCHER RINSERS PER 2018 PHILA PLUMBING CODE

  123. PermitSign

    Permit 1052710 · Completed

    ERECTION OF ONE (1) INTERIOR "ROUND 1" CHANNGEL LETTERS AS PART OF AN EXISTING ASSEMBLY AND ENTERTAINMENT USE.

  124. PermitAmend for conversion

    Permit 1047750 · Issued

    TO AMEND PERMIT#1031229 TO DOCUMENT INTERIOR LAYOUT CHANGES , AND CEILING MODIFICATIONS. ALSO TO PROVIDE NEW SHEVING RACKS AS PER APPROVED PLANS.**NO SIGNS APPROVED ON THIS PERMIT**

  125. PermitAmend for conversion

    Permit 1055291 · Completed

    AMEND FIRE SUPPRESSION PERMIT NO. 1032456 TO REVISE LAYOUT DUE TO RESTROOM CHANGES TO INCLUDE ADDITIONAL PIPING AND (13) SPRINKLER HEADS AS PER APPROVED PLANS AND N ACCORDANCE WITH NFPA 13.

  126. PermitNew Construction

    Permit 1054320 · Completed

    LOW VOLTAGE INSTALLATION ADDING 3 ANTI THEFT BARRIER PEDASTALS FLOOR MOUNTED AND WIRE BACK TO A MONITOR PANEL AT DSW DEPART STORE

  127. PermitNew Construction

    Permit 1050873 · Completed

    Provide power, lighting, and receptacles for tenant fit-out as per 2017 NEC. Low voltage wiring will be performed by another contractor.

  128. PermitSign

    Permit GP-2020-001049 · Completed

    FOR THE INSTALLATION OF FOUR ACCESSORY SIGNS (KATE SPADE) IN SHOPPING MALL AS FOLLOWS: TWO (2) ILLUMINATED, DOUBLE-SIDED BLADE SIGNS MEASURING 30" X 36"; ONE (1) ILLUMINATED WALL SIGN MEASURING 87.25" X 132"; ONE (1) ILLUMINATED WALL SIGN MEASURING 59.25" X 128". **EXTERIOR WALL SIGN REFER #4 NOT INCLUDED IN THIS PERMIT**

  129. PermitNew Construction

    Permit 1049039 · Completed

    PROVIDE FIRE ALARM SYSTEM FOR TENNANT FIT OUT AS PER NFPA 72.

  130. PermitAddition and/or Alteration

    Permit EP-2020-000104 · Completed

    Low voltage cabling: Data: 23 runs; 7,500 feet of CAT5e cable for Sites as per print CCTV: 13 runs Alarms: 11 runs; Speakers: 3,000ft 18/2 cable 47 Cat5E 18 Speaker cable runs

  131. PermitNew Construction

    Permit 1053967 · Completed

    PROVIDE POWER, LIGHTING, RECEPTACLES FOR WHITE BOX.'17 NEC. PROVIDE FIRE ALARM FOR WHITE BOX.'17 NEC .'16 NFPA-72

  132. PermitNew Construction

    Permit 1054789 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTUER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  133. PermitRough-In

    Permit 1056004-RI · Completed

    INSTALL BUILDING SYSTEM FIRE ALARM TIED TO EXISTING SYSTEM PER DRAWINGS TEST AND CETRIFICATION BY SIEMENS

  134. PermitNew Construction

    Permit 1045547 · Completed

    INSTALL NEW SERVICE FED FROM LL MAIN GEAR, INSTALL BRANCH CIRCUITS TO POWER LIGHTS, OUTLETS AND EQUIPMENT. INSTALL LOW VOLTAGE CABLE FOR SPEAKERS AND TELE/DATA DEVICES AS PER 2017 NEC.

  135. PermitNew Construction

    Permit 1050540 · Completed

    FIRE ALARM INCLUDING 1 FACP, 1 PULL STATION, 4 HORN/STROBE, 1 STROBE ONLY AND 1 SMOKE DETECTOR PER '16 NFPA 72 (CC DIST)

  136. PermitRough-In

    Permit 1054320-RI · Completed

    LOW VOLTAGE INSTALLATION ADDING 3 ANTI THEFT BARRIER PEDASTALS FLOOR MOUNTED AND WIRE BACK TO A MONITOR PANEL AT DSW DEPART STORE

  137. PermitAddition and/or Alteration

    Permit 1052113 · Completed

    FOR THE ERECTION OF KIOSK AS PER APPROVED PLANS. NO SIGNS THIS PERMIT. **SEPARATE PERMITS REQUIRED FOR MEP WORK** **IEBC 2018**

  138. PermitRough-In

    Permit 1043719-RI · Expired

    INSTALL 10 CIRCUITS TO CONTROL 5 NEW LIGHT FIXTURES RELOCATED EXISTING SERVICE PANEL & FEEDER INSTALL CONDUIT IN SLAB AS PER '17 NEC.

  139. PermitAmend for conversion

    Permit 1053609 · Completed

    AMEND ALTERATIONS PERMIT NO. 1049670 TO CORRECT SPACE NUMBER TO SPACE 1085 (NOT 1185).

  140. PermitAlterations

    Permit 1052799 · Completed

    FURNISH AND INSTALL 3 FIXTURES AS PER 2017 PPC

  141. PermitCertificate of Occupancy (CO) (may inclu…

    Permit 1046145 · Completed

    APPLICATION FOR CERTIFICATE OF OCCUPANCY. *SEE AP#1023129 FOR PREVIOUS PERMIT, AP# 728409 FOR BASE BUILDING WORK AND AP# 978149 FOR LANDLORD WORK**

  142. PermitSign

    Permit 1044516 · Completed

    FOR THE INSTALLATION OF ONE (1) ILLUMINATED INTERIOR SIGN CABINET @21SF. ACCESSORY TO USE AS LIBRARIES AND CULTURAL EXHIBITS (ART GALLERY) WITH ALL OTHER USES AS PREVIOUSLY.

  143. PermitAddition and/or Alteration

    Permit 1049670 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CREATE A VANILLA BOX COMMERCIAL SPACE (SEPARATE PERMIT REQUIRED FOR CO PRIOR TO OCCUPANCY) IN TENANT SPACE 1185 OF AN EXISTING COVERED MALL BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  144. PermitNew Construction

    Permit 1051959 · Completed

    INSTALL 16 LOUD SPEAKERS AND AMPLIFIER AS PER 2017 NEC SQ FT 15648

  145. PermitNew Construction

    Permit 1051571 · Completed

    FURNISH & INSTALL 63-CAT6 PLENUM RATED CABLES FOR VOICE/DATA LONGEST RUN 150' AS PER NEC 2017 CC DISTRICT

  146. PermitRough-In

    Permit 1050843-RI · Expired

    LOW VOLTAGE INSTALLATION ADDING A BURGULAR ALARM SYSTEM THROUGH ENTIRE SPACE WITH MOTION DETECTORS, KEYPAD, DOOR CONTACTS, SOUNDERS, AND A PANEL IN DSW DEPARTMENT STORE.

  147. PermitRough-In

    Permit 1050873-RI · Completed

    PROVIDE POWER, LIGHTING AND RECEPS FOR TENANT FIT OUTN

  148. PermitNew Construction

    Permit 1050705 · Completed

    Relocate (25) sprinkler heads to accommodate a new tenant layout.

  149. PermitNew Construction

    Permit 1049870 · Completed

    6 SPEAKERS,2 SUBWOOFERS,1 AMP AND MUSIC PLAYER PER 2017 NEC (COMMERCIAL)

  150. PermitAlterations

    Permit 1040269 · Expired

    PROVIDE/MODIFY SANITARY VENT AND WATER TO ALLOW FOR NEW WATER HEATER, MOP SINK AND FLOOR DRAIN PER 2004 PHILA PLUMBING CODE

  151. PermitAlterations

    Permit 1040276 · Expired

    TIE INTO EXISTING SANITARY VENT AND WATER TO ALLOW FOR NEW WATER HEATER, MOP SINK AND FLOOR DRAIN PER 2004 PHILA PLUMBING CODE

  152. PermitSign

    Permit 1043328 · Expired

    FOR THE ERECTION OF ONE (1) NEW WALL SIGN, AND ONE (1) PROJECTING SIGN MAX 2' PROJECTION. ALL ILLUMINATED. SIZE AND LOCATION AS SHOWN IN THE ATTACHED PLANS. SIZE AND LOCATION AS SHOWN IN THE ATTACHED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK. SIGNS ONLY PERMIT. ACCESSORY TO PREVIOUSLY APPROVED RETAIL SALES OF FOOD, BEVERAGES, TAKE-OUT/SIT DOWN RESTAURANT.

  153. PermitSign

    Permit 1043497 · Completed

    INSTALL (1) SET OF HALO LIT LED LETTERS ON INTERIOR STOREFRONT 17.75" HIGH BY 54" WIDE= 6.65 FT2. INSTALL (1) SET OF HALO LIT LED LETTERS ON INTERIOR STOREFRONT 46.5685" HIGH BY 112.6453" WIDE = 36.5 FT2. (DETAILS AS SHOWN ON THE PLAN).

  154. PermitAmend for conversion

    Permit 1044802 · Issued

    AMENDMENT TO 1019222 UPDATE INSTALLATION PER ATTACHED PLANS

  155. PermitAddition and/or Alteration

    Permit 1033644 · Completed

    INTERIOR ALTERATIONS TO FIT-OUT RETAIL SPACE C110 IN THE CONCOURSE LEVEL OF AN EXISTING SHOPPING MALL AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. *2018* SEE AP#1009779 FOR PREVIOUS PERMIT. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  156. PermitNew Construction

    Permit 1044274 · Completed

    7 STROBES, 1 NAC PANEL, 1 SMOKE DETECTOR, 2 RELAYS PER NFPA 72 (CC DIST)

  157. PermitNew Construction

    Permit 1044512 · Completed

    FURNISH AND INSTALL ALL NEW SERVICE, OUTLETS AND LIGHTING PER PLANS ALONG WITH SPEAK AND TELEDATA WIRING.'17 NEC.

  158. PermitSign

    Permit 1048662 · Expired

    WALL SIGN PERMIT-Installation of # 1 flat wall sign as per application# 1048662. Through bolt sign with 3/8" bolts as per detail.

  159. PermitNew Construction

    Permit 1044269 · Completed

    3 STROBES, 1- NAC PANEL, 1- SMOKE DETECTOR, 2- RELAYS PER NFPA 72 (CC DIST)

  160. PermitNew Construction

    Permit 1043711 · Completed

    PROVIDE LIGHTING AND RECEPTACLES FOR TENANT FIT-OUT.PER '17 NEC.

  161. PermitNew Construction

    Permit 1043026 · Expired

    Relocate 69 existing sprinkler heads.

  162. PermitNew Construction

    Permit 1043034 · Completed

    Relocate 53 existing sprinkler heads.

  163. PermitNew Construction

    Permit 1043029 · Expired

    Relocate 23 existing sprinkler heads.

  164. PermitNew Construction

    Permit 1043246 · Completed

    100A 480 V PANEL -- 10 SWITCHES, 30 KVA TRANSFORMER -- 1 VAV BOX, 100A 208 V PANEL, 20 RECEPTACLES, 1 EWH.'17 NEC.

  165. PermitNew Construction

    Permit 1043262 · Completed

    150A 480/277V PANEL, 45KVA TRANSFORMER, 150A 208/120 V PANEL, TIME CLOCK, 20 RECEPTACLES 132 LIGHT FIXTURES, 3 SWITCHES, 1 VAV, 1 EWH, 1 EX FAN AS PER 2017 NEC. (CC DISTRICT)

  166. PermitAlterations

    Permit 1044803 · Completed

    RUN SANITARY & WATER LINES FROM THE MAINS FOR 1 WATER CLOSET, 1 LAV & 1-EEMAX INSTANT WARM WATER HEATER for 9th Market Street Plumbing permits

  167. PermitAddition and/or Alteration

    Permit 1037966 · Completed

    LEVEL II INTERIOR ALTERATIONS TO FIT-OUT RETAIL SPACE #2045 IN THE AN EXISTING SHOPPING MALL AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK.

  168. PermitNew Construction

    Permit 1038565 · Completed

    FOR THE INSTALLATAION OF NEW HVAC SYSTEM, ASSOCIATED DUCTWORK AND EIGHTEEN (13) REGISTERS/DIFFUSSERS TO BE TIED INTO EXISTING SYSTEM AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION. (SEE AP#1037966 FOR PLANS)

  169. PermitAlterations

    Permit 1043899 · Completed

    INSTALL 1-WATER COOLER & RUN SANITARY & WATER LINES TO THE MAINS LINES THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  170. PermitSign

    Permit 1019222 · Expired

    ILLUMINATED LOGO SIGN 75" X 17'-7 5/8" FOR THE ERECTION OF AN INTERNALLY ILLUMINATED ACCESSORY LOGO (FLAT WALL ) SIGN ON AN EXISTING STRUCTURE (SIZE AND LOCATION AS SHOWN ON THE PLAN) SIGN ACCESSORY TO AN EXISTING RETAIL SALES OF WEARING APPAREL IN SPACE # 1095 IN THE SAME BUILDING WITH OTHER EXISTING USES AS PREVIOUSLY APPROVED.

  171. PermitNew Construction

    Permit 1032930 · Completed

    INSTALLATION OF A NEW MECHANICAL SYSTEM FOR THE THIRD FLOOR OF AN EXISTING STRUCTURE TO INCLUDE A NEW HVAC SYSTEM,AIR HANDLERS , REGISTERS AND DIFFUSERS, AND ALL ASSOCIATED DUCTWORK AS PER APPROVED PLANS.APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY ,CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS REQUIRED FOR ANY OTHER ELECTRICAL PLUMBING AND FIRE SUPPRESSION WORK**

  172. PermitAddition and/or Alteration

    Permit 1031229 · Completed

    LEVEL II INTERIOR ALTERATION FOR TENANT FIT OUT OF AN EXISTING WHITE BOX SPACE( SPACE#1065-KATE SPADE). ALTERATION TO INCLUDE THE ERECTION OF NON LOAD BEARING PARTITIONS, FURNISHINGS, MILLWORK FIXTURES, NEW FINISHES, AND ALL OTHER WORK AS PER APPROVED PLANS.**REFER TO ORIGINAL ALTERATIONS PERMIT AP# 728409 FOR BASE BUILDING WORK AND AP# 978149 FOR LANDLORD WORK** SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING.SIGN AND FIRE SUPPRESSION WORK**IEBC 2018**

  173. PermitRough-In

    Permit 1041109-RI · Completed

    ALL PLUMBING FOR KIOSK POTATO CORBER- FIXTURES INCLUDE: 2- FLOOR SINKS, 1-MOP SINK, 1-3 COMP SINK, ALSO A WATER HEATER AND GREASE TRAP

  174. PermitNew Construction

    Permit 1032774 · Issued

    network cabling, longest run of 250' speaker installation per 2017 nec (cc dist)

  175. PermitAddition and/or Alteration

    Permit 1031646 · Completed

    LEVEL II INTERIOR ALTERATIONS TO FIT-OUT SPACE #1165 FOR A TAKE-OUT RESTAURANT (STARBUCKS COFFEE) IN THE AN EXISTING SHOPPING MALL AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK.

  176. PermitNew Construction

    Permit 1023392 · Completed

    HVAC SYSTEM INSTALLATION FOR SPACE 3020 ON THIRD FLOOR OF EXISTING BUILDING AS PER APPROVED PLANS. ** 2019 IMC **

  177. PermitNew Construction

    Permit 1039220 · Completed

    INSTALL 1-120/208V 150AMP 3PHASE 4WIRE PANEL BOARD,INSTALL 15-RECEPTS FOR KITCHEN EQUIPMENT 120V 20AMPS EACH,INSTALL 2-LIGHTING CIRCUITS AT 120V 20AMPS FOR LED GRAPHICS AND LED LIGHTS AS PER 2017 NEC (CC DISTRICT)

  178. PermitAddition and/or Alteration

    Permit 1036221 · Expired

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS. CONSTRUCTION OF A NEW KIOSK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK.

  179. PermitAddition and/or Alteration

    Permit 1036217 · Completed

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS. CONSTRUCTION OF A NEW KIOSK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK.

  180. PermitNew Construction

    Permit 1028933 · Completed

    TENANT FIT OUT OF OFFICES & COMMON SPACES UTILIZING NEW & EXISTING PANELS FOR BRANCH WIRING, LTG & RECEPTS. AS PER 2017 NEC.(CC DISTRICT) INSTALL NEW FIRE ALARM PANEL ON EXISTING BUILDING SYSTEM WITH WIRING & DEVICE PER PLANS.AS PER NFPA72.(CC DISTRICT)

  181. PermitNew Construction

    Permit 1020534 · Expired

    FOR INSTALLATION OF HVAC SYSTEM INCLUDING 7 AIR REGISTERS- 3 LINEAR AT G.W.B., 4 AT EXPOSED DUCTWORK . 1 RETURN AIR TRANSFER GRILL AT STOCKROOM WALL. VAV AIR RETURN IS THROUGH EXISTING SLOT DIFFUSERS LOCATED IN THE EXISTING MALL BULKHEAD ABOVE THE TENANT STOREFRONT AS PER PLANS.

  182. PermitAddition and/or Alteration

    Permit 1019769 · Expired

    FOR INTERIOR ALTERATIONS TO INCLUDE FITOUT OF MERCANTILE SPACE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  183. PermitAddition and/or Alteration

    Permit 1019773 · Completed

    FOR INTERIOR ALTERATIONS TO EXISTING TENANT SPACE TO INCLUDE NEW PARTITIONS, STOREFRONT AND INTERIOR FINISHES, AS PER APPROVED PLANS.

  184. PermitNew Construction

    Permit 1031616 · Expired

    FOR MECHANICAL ALTERATIONS TO EXISTING TENANT SPACE, TO INCLUDE NEW REGISTERS/DIFFUSERS WITH ASSOCIATED DUCTWORK, AS PER APPROVED PLANS. SEE APP# 1019773 FOR APPROVED PLANS.

  185. License issue eventRound One Entertainment, Inc.: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 832089 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  186. License issue eventKNEAD MORE DOUGH LLC: Food Preparing and Serving business license initially issued

    License 831813 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  187. PermitNew Construction

    Permit 1032456 · Completed

    EXTENSION OF EXISTING NFPA 13 SPRINKLER SYSTEM TO PROTECT COMMERCIAL SPACE 3020 IN AN EXISTING COVERED MALL BUILDING AS PER APPROVED PLANS. NO WORK TO EXISTING MAIN AND RISER. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  188. PermitAddition and/or Alteration

    Permit 1025607 · Completed

    TENANT FIT OUT OF A KIOSK FOR POTATO CORNER IN TENABT SPACE K07 AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL MEP/FSP WORK; BUILDING IS FULLY SPRINKLERED; NO SIGNS ON THIS PERMIT.

  189. PermitNew Construction

    Permit 1031867 · Issued

    TYING SIGNS INTO PROVIDED CIRCUITS PER EACH SIGN LOCATION. INTERIOR CONCOURSE SIGNS-ALL WIRING IN CONDUIT. 110V CIRCUIT 1 20AMP 110V DEDICATED CIRCUIT PER SIGN, 9 ADDDITIONAL INTERIOR SIGNS, PLEASE SEE ATTACHED ELECTRIC DRAWINGS. '17 NEC

  190. PermitNew Construction

    Permit 1031868 · Completed

    TYING SIGNS INTO PROVIDED CIRCUITS PER EACH SIGN LOCATION. 1. EXTERIOR CHANNEL LETTER "SIGN A" 3 AMPS. 1 EXTERIOR CHANNEL LETTER "SIGN B" 7 AMPS. 1 LED MODULE 10AMP OPEN SIGN PROVIDE DUPLEX. ALL SIGN POWER SUPPLYS ARE RATED 110-277 VOLTS PER 2017 NEC

  191. PermitAlterations

    Permit 1027240 · Completed

    FURNISH AND INSTALL (20) WATER, (11) LAVS, (5) KITCHEN SINKS, (2) DRINKING FOUNTAINS, (3) FLOOR DRAINS, (4) 20-GALLON WATER HEATERS--PROVIDE LABOR AND MATERIAL TO EXTEND FROM EXISTING SANITARY AND DOMIESTIC WATER AS SHOWN **PLUMBING CODE

  192. PermitSign

    Permit 1026247 · Expired

    INSTALL SIGN (1) INTERIOR 70"W X 20"H LED ILLUM FLAT WALL SIGN AND (2) EXTERIOR ILLUM CHANNEL LETTER FLAT WALL SIGNS 184"W X 48"H ACCESORY SIGNAGE FOR SPACE #2120.

  193. PermitSign

    Permit 1026096 · Expired

    FOR THE ERECTION OF NINE (9) FLAT WALL SIGNS (STATIC ILLUMINATION). SIZES AND LOCATIONS AS SHOWN PER APPROVED PLANS/APPLICATION. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  194. PermitSign

    Permit 1026111 · Completed

    FOR THE ERECTION OF THREE (3) FLAT WALL SIGNS AND ONE (1) PROJECTING SIGN (STATIC ILLUMINATION). SIZES AND LOCATIONS AS SHOWN PER APPROVED PLANS/APPLICATION. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  195. PermitSign

    Permit 1023234 · Expired

    AMERICAN EAGLE INSTALL (1) SINGLE FACED, SET OF FACT LIT CHANNEL LETTERSON EXTERIOR STOREFRONT ELEVATION. 24"HHIGH BY 373.6875"WIDE=62.28 FT2 AERIE INSTALL (1) SINGLE FACED, SET OF FACE LIT CHANNEL LETTERS ON EXTERIOR STOREFRONT ELEVATION. 33"HIGH BY 81.1875" WIDE = 18.6 FT2

  196. PermitNew Construction

    Permit 995916 · Completed

    PROVIDE COMPLETE FIRE ALARM SYSTEM FOR TENANT SPACE. AS PER 2017 NFPA72. (CC DISTRICT)

  197. PermitNew Construction

    Permit 1028026 · Expired

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK IN A ASSEMBLY OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  198. License issue eventTHE JUICE SQUAD: Food Preparing and Serving business license initially issued

    License 829412 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  199. PermitNew Construction

    Permit 1027511 · Completed

    INSTALL 21-CCTV CAMERAS,1-NVR,ALL EQUIPMENT FURNISHED BY OTHERS,INSTALL WIRING FOR DEVICES,INSTALL 1-KEYPAD,1-ALARM,1-SIREN,9-MOTION DETECTORS,1-DOOR CONTACT AND 5-GLASS BREAKS AS PER 2017 NEC (CC DISTRICT)

  200. PermitNew Construction

    Permit 1015859 · Completed

    AMENDING PERMIT #973786 DESIGN MODIFICATION AS PER APPROVED PLAN. '17 NEC.

  201. PermitNew Construction

    Permit 1011494 · Completed

    PROVIDE FIRE ALARM FOR A RETAIL FIT OUT AS PER ENGINEER SEALED AND CITY APPROVED DRAWINGS ,NFPA 72.

  202. PermitNew Construction

    Permit 1014702 · Completed

    PROVIDE 100 AMP FEEDER, POWER TO DOOR OPERATORS AND A DOOR BUZZER. PROVIDE TEMPORARY LIGHTING AND RECEPTACLES AS PER 2017 NEC (CC DIST)

  203. PermitNew Construction

    Permit 1010358 · Completed

    PROVIDE FIRE ALARM FOR TENANT SPACE AS PER ENGINEER SEALED AND CITY APPROVED DRAWINGS.

  204. PermitAddition and/or Alteration

    Permit 1010280 · Completed

    EXTERIOR ALTERATION AND LEVEL II INTERIOR ALTERATIONS FOR TENANT FIT-OUT ON THE THIRD FLOOR LEVEL OF THE FASHION DISTRICT OF PHILADELPHIA AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *IEBC 2018**SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  205. PermitNew Construction

    Permit 1007297 · Expired

    INSTALL NEW DATA LINES AND POINT OF SALE REGISTERS. INSTALL NEW PATCH IN TELECOM/SERVER ROOM.'17 NEC.

  206. PermitAddition and/or Alteration

    Permit 1012075 · Completed

    FOR INTERIOR ALTERATIONS TO INCLUDE FITOUT OF MERCANTILE SPACE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  207. PermitSign

    Permit 995058 · Expired

    INSTALLATION OF A DOUBLE FACED ILLUMINATED PROJECTING SIGN PER APPROVED PLANS. SIGN ACCESSORY TO SPACE #500. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  208. PermitNew Construction

    Permit 1013715 · Completed

    13 SPEAKERS,1 AMP,1 MUSIC PLAYER AND 1 VOLUME CONTROLLER PER 2017 NEC (RETAIL)

  209. License issue eventCity Winery Philadelphia, LLC: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 824046 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  210. PermitNew Construction

    Permit 1007315 · Completed

    INSTALL FIRE ALARM FOR TENANT SPACE IN SHOPPING MALL

  211. PermitNew Construction

    Permit 1001987 · Expired

    INSTALLATION OF STRUCTURED COMMUNICATIONS CABLING SYSTEM AND PERIFERAL EQUIPMENT. INSTALLATION OF TERMINATION EQUIPMENT INTO WALL MOUNT RACK. 43 TOTAL CAT6 CABLES, LONGEST RUN ESTIMATED AT 125 FEET AS PER 2017 NEC (CC DIST)

  212. PermitNew Construction

    Permit 1006931 · Completed

    PROVIDE FIRE ALARM FOR TENANT FIT OUT NFPA 72 (CC DIST)

  213. PermitNew Construction

    Permit 1009620 · Expired

    Relocate 8 existing sprinkler heads

  214. PermitNew Construction

    Permit 1005920 · Expired

    INSTALLATION OF NEW HVAC SYSTEM FOR RETAIL SPACE 2050 IN AN EXISTING COVERED MALL BUILDING TO INCLUDE DUCTWORK, EXHAUST FAN AND VAV BOXES AS PER APPROVED PLANS.

  215. PermitNew Construction

    Permit 1000125 · Completed

    TO INSTALL A NEW BURGULAR ALARM SYSTEM WITH A VISTA-20P PANEL, DOOR CONTACTS, GLASS BREAKS, KEYPAD AND MOTION DETECTORS, NEW CCTV SYSTEM SHALL INCLUDE DVR, POE SWITCH AND CAMERAS AS PER NEC 2017 (CENTER CITY DIST.)

  216. License issue eventAPS GALLERY FOODS, LLC: Food Preparing and Serving business license initially issued

    License 821723 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  217. PermitNew Construction

    Permit 996595 · Expired

    INSTALL FIRE ALARM WIRING AND DEVICES FOR LANDLORD UNDER DRAWINGS PER 2017 NEC

  218. PermitNew Construction

    Permit 1001623 · Expired

    ALL LOW VOLTAGE - INSTALL 1-INTRUSION PANEL, 1-KEYPAD, 2-WIRELESS DOOR CONTRACTS, 1-DOOR CONTACT, 2-MOTION DETECTORS, 1-SIREN & 1-WIRELESS RECEIVER AS PER NEC 2017 CC DISTRICT

  219. PermitNew Construction

    Permit 1000788 · Completed

    INSTALL CAT6 CABLE FROM IDF CLOSETS TO 137 FURTURE SPACES AS PER 2017 NEC

  220. PermitNew Construction

    Permit 990035 · Completed

    ELECTRICAL LIGHTING AND DEVICES FOR NEW TENANTS. 10 RECEP 10 SWITCHES PER 2017 NEC

  221. PermitNew Construction

    Permit 987875 · Issued

    INSTALL ONE ELECTRICAL PANEL. INSTALLATION OF POWER RECEPTS AND LIGHTING. INSTALLTION OF LOW VOLTAGE CABLE FOR SOUND, SECURITY, AND CAT 5 CABLING FOR TELE/DATA SYSTEM AND LOW VOTAGE SWITCHES. AS PER 2017 NEC (CC DISTRICT) NO FIRE ALARM.

  222. PermitNew Construction

    Permit 975683 · Completed

    FURNISH LABOR AND MATERIAL FOR A TENANT FITOUT INCLUDING TEMPORARY NEW SERVICE TO SPACE NEW LIGHTING POWER A/V TELE/DATA AND SECURITY FOR RETAIL SPACE PER 2017 NEC INSTALL COMPLETE FIRE ALARM SYSTEM PER ENGINEER SEALED AND CITY APPROVED DRAWINGS.

  223. PermitNew Construction

    Permit 993018 · Expired

    INSTALL 7-NEW CAMERAS WITH NVR AND ADDING INTRUSION SYSTEM CONTAINING ALARM PANEL, 3-MOTION DETECTORS, 2-WIRELESS PANIC BUTTON AND SOUNDER AS PER NEC 2017 CC DISTRICT

  224. PermitAddition and/or Alteration

    Permit 962507 · Completed

    LEVEL II INTERIOR ALTERATIONS WITH A PARTIAL CHANGE OF OCCUPANCY FOR FIT-OUT OF ACCESSORY CLOTHING STORAGE (SPACE 2050A) WITHIN THE SECOND LEVEL OF THE FASHION DISTRICT OF PHILADELPHIA, WITH NO STRUCTURAL WORK, AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  225. PermitNew Construction

    Permit 990609 · Completed

    8 SPEAKERS,1 AMP,1 MUSIC PLAYER AND 1 VC PER 2017 NEC (COMMERCIAL)

  226. PermitAddition and/or Alteration

    Permit 978043 · Expired

    LEVEL II INTERIOR ALTERATIONS TO CREATE RESTAURANT SPACE (SPACE 2037) WITHIN THE FASHION DISTRICT OF PHILADELPHIA, WITH NO STRUCTURAL WORK, AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  227. PermitNew Construction

    Permit 980700 · Completed

    PROVIDE FIRE ALARM SYSTEM FOR TENANT SPACE AS PER NFPA 72

  228. PermitNew Construction

    Permit 986538 · Completed

    15 CAMERAS,3 TOUCH SCREENS,16 SPEAKERS AND CAT 5 WIRE PER 2017 NEC (RETAIL SPACE)

  229. PermitAddition and/or Alteration

    Permit 976882 · Completed

    LEVEL II INTERIOR ALTERATIONS TO FIT-OUT SPACE C198B FOR A RETAIL BAKERY PREP AREA IN AN EXISTING MALL BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  230. PermitNew Construction

    Permit 976526 · Completed

    relocate (4) existing sprinkler heads to accommodate new tenant layout.

  231. PermitAddition and/or Alteration

    Permit 975475 · Completed

    LEVEL II INTERIOR ALTERATIONS TO FIT-OUT SPACE C198 FOR A RETAIL EYE WEAR STORE IN AN EXISTING MALL BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. *2018* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  232. PermitNew Construction

    Permit 972514 · Expired

    INSTALLATION OF NEW HVAC SYSTEM FOR SPACE 2090 TO INCLUDE DUCTWORK AS PER APPROVED PLANS.

  233. PermitNew Construction

    Permit 973500 · Issued

    BLDG A SPACE C-220A INSTALLATION OF (5) LIGHTS (40) 20 AMP RECEPTACLES AND (1) MECHANICAL UNIT

  234. PermitNew Construction

    Permit 973504 · Issued

    BLDG C SPACE 145 11 LIGHT FIXTURES, 4-20AMP RECEPTACLES, 1 MECH UNIT.

  235. PermitNew Construction

    Permit 881286 · Issued

    INSTALLATION OF (2)100AMP PANELS,(1)30KVA TRANSFORMER,COMMON AREA LIGHTING AND BRANCH POWER FOR CORE AND SHELL APPROX 11 RECEPTACLES AND 50 LIGHTS FIXTURES PER 2008 NEC (RETAIL)

  236. PermitNew Construction

    Permit 875308 · Expired

    INSTALLATION OF NEW HVAC SYSTEM FOR RETAIL TENANT SPACE C145 WITHIN AN EXISTING COVERED MALL BUILDING TO INCLUDE VAV, DUCTWORK AND GRD'S AS PER APPROVED PLANS.

  237. PermitZoning

    Permit 730164 · COMPLETED

    FOR THE ESTABLISHMENT OF UNITY OF USE TO CREATE ONE (1) LOT FOR ZONING PURPOSES (TO BE KNOWN AS 907-37 MARKET STREET) WITH RESTRICTIVE COVENANTS, AGREEMENTS AND EASEMENTS TO BE RECORDED BY DEED TO BIND CURRENT AND FUTURE OWNERS OF THE CONTIGUOUS TEN (10) (801S MARKET ST # A, 833 MARKET ST, 901S MARKET ST # A, 901 MARKET ST, 903 MARKET ST, 905 MARKET ST, 907-37 MARKET ST, 1001-19 MARKET ST, 1025 MARKET ST, 15-19 N 10TH ST) PARCELS TO PRESERVE THE UNITY OF USE AND THE LEGALITY OF THE ENTIRE PROJECT THAT STEMS FROM SINGLE ZONING LOT TREATMENT. PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY, PROOF OF RECORDATION OF EASEMENTS, AGREEMENTS AND RESTRICTIVE COVENANTS MUST BE SUPPLIED. SEE A/P NO 728943.

  238. InvestigationCI INSP

    Case 458197 · PASSED

    The cited inspection visit was marked passed.

  239. ViolationFIRE PROT SYS MAINTENANCE

    Case 458197 · Violation 3370547 · Code FC-901.7/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  240. ViolationVIOL C&I MESSAGE

    Case 458197 · Violation 3370546 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  241. InvestigationCI INSP

    Case 458197 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 25, 2026, 1:57 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)