Property report

1626-44 Fairmount Ave

4 stories66,334 sqftCMX2built 1920

Property at a glanceApartment building

Mm Fairmount Ave Partners

2026 assessment
$4.9M OPA value, not a listing price
2027 published assessment
$3.7M Future roll, not the current tax bill
Neighborhood area
Fairmount · Spring Garden Approximate · based on ZIP 19130
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $3,657,300. It is not yet the billed-year tax basis.

$0$2.5M$5.0M$3.7M2004200820122016202020242027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record128 events · exact dates, newest first
  1. InspectionL&I investigation
  2. L&I violationBENCHMARKING LATE
  3. InspectionL&I investigation
  4. CertificationFire Alarm Certification
  5. CertificationFire Alarm Certification
  6. CertificationSpecial Hazards Certification
  7. CertificationFire Alarm Certification
  8. CertificationFire Alarm Certification
  9. CertificationFire Alarm Certification
  10. CertificationSprinkler Certification
  11. InspectionL&I investigation
  12. CertificationSpecial Hazards Certification
  13. InspectionL&I investigation
  14. L&I violationCOMMERCIAL COOKING SYSTEMS
  15. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  16. L&I violationPERIODIC TESTING
  17. InspectionL&I investigation
  18. CertificationFire Alarm Certification
  19. CertificationFire Alarm Certification
  20. PermitAddition and/or Alteration
  21. CertificationFire Alarm Certification
  22. LicenseMM FAIRMOUNT AVE PARTNERS LP: Rental landlord or residential registration marked inactive
  23. PermitAlterations
  24. PermitAddition and/or Alteration
  25. PermitZoning/use
  26. PermitAdministrative
  27. PermitElectrical
  28. PermitMechanical
  29. PermitSuppression
  30. InspectionPRECOURT (likely: pre-court compliance inspection)
  31. PermitPlumbing
  32. PermitMajor alteration
  33. InspectionPRECOURT (likely: pre-court compliance inspection)
  34. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  35. InspectionCI INSP
  36. InspectionCI INSP
  37. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  38. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  39. L&I violationFIRE ALARM TESTED/CERTIFIED
  40. L&I violationPULL STATION SIGNS
  41. L&I violationOPEN JUNCTION BOXES
  42. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  43. InspectionCI INSP
  44. PermitUse
  45. LicenseMM FAIRMOUNT AVE PARTNERS LP: Rental landlord or residential registration initially issued
  46. PermitSign
  47. PermitZoning/use
  48. PermitZoning/use
  49. PermitSign
  50. PermitMechanical
  51. PermitAdministrative
  52. PermitElectrical
  53. PermitMajor alteration
  54. PermitNew Construction
  55. PermitElectrical
  56. PermitUse
  57. PermitAlteration
  58. PermitMajor alteration
  59. PermitUse
  60. PermitSign
  61. PermitElectrical
  62. PermitPlumbing
  63. PermitSuppression
  64. PermitMechanical
  65. PermitSuppression
  66. L&I violationPERMB- INSTALL DUCTWORK
  67. PermitPlumbing
  68. PermitElectrical
  69. PermitZoning/use
  70. PermitUse
  71. PermitMajor alteration
  72. PermitPlumbing
  73. L&I violationINSURANCE - POST CERT
  74. L&I violationLIC MUST BE AVAIL FOR INSP
  75. PermitMajor alteration
  76. PermitAlteration
  77. PermitZoning admin review
  78. PermitUse
  79. PermitZoning
  80. PermitZoning
  81. PermitZoning
  82. PermitZoning
  83. PermitZoning
  84. InspectionPRECOURT (likely: pre-court compliance inspection)
  85. InspectionPRECOURT (likely: pre-court compliance inspection)
  86. InspectionPRECOURT (likely: pre-court compliance inspection)
  87. InspectionBC INSP (likely: building-code inspection)
  88. InspectionBC INSP (likely: building-code inspection)
  89. InspectionBC INSP (likely: building-code inspection)
  90. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  91. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  92. InspectionBC INSP (likely: building-code inspection)
  93. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  94. L&I violationPERM Z- NEW USE
  95. L&I violationPERM Z- NEW USE
  96. InspectionBC INSP (likely: building-code inspection)
  97. InspectionPRECOURT (likely: pre-court compliance inspection)
  98. InspectionBC INSP (likely: building-code inspection)
  99. InspectionPRECOURT (likely: pre-court compliance inspection)
  100. L&I violationLICENSE-VAC LOT
  101. L&I violationLICENSE-VAC LOT
  102. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  103. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  104. InspectionPRECOURT (likely: pre-court compliance inspection)
  105. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  106. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  107. L&I violationEXT S-CORNICE BARGEBOARD DEFEC
  108. L&I violationLICENSE-VAC COMM BLDG
  109. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  110. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  111. L&I violationLICENSE-VAC COMM BLDG
  112. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  113. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  114. InspectionCSUINITIAL
  115. InspectionCSUINITIAL
  116. PermitMajor alteration
  117. InspectionCSUINITIAL
  118. InspectionCSUINITIAL
  119. AppealRB_LIRB
  120. L&I violationWALL FRACTURED
  121. L&I violationARCHITECT/ENGINEER SERVICES
  122. L&I violationWALL DETERIORATED
  123. InspectionCSUINITIAL
  124. InspectionCSUINITIAL
  125. L&I violationROOF PARTIALLY COLLAPSED
  126. InspectionCSUINITIAL
  127. InspectionCSUINITIAL
  128. InspectionL_INITIAL

Verify the public record

$40,427/year estimated property tax

2026 taxable assessment $2,888,070 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $3,657,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881809850
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $2,888,070 of $4,853,900 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Apartment building, recorded in the City's multi-family category. The public record and owner trail follow.

What it is
Apartment building Apts 5-50 Units Masonry
Owner
Mm Fairmount Ave Partners
$ / sq ft
$55 assessed value ÷ interior sqft
Corridor
Broad and Fairmount city commercial corridor
Interior area
66,334 sqft
Lot size
18,914 sqft
Stories
4
Built
1920
Zoning
CMX2

Recorded owner

Who's behind it

Mm Fairmount Ave Partners · corporate / LLC owner

• Owns 2 properties across Philadelphia under this name, assessed at $4.8M combined
• Tax bills mail to Po Box 56313, Philadelphia PA, 19130

Block context

1600 block of Fairmount Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1624 Fairmount Ave  ·  1622 Fairmount Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 23, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

MM FAIRMOUNT AVE PARTNERS LPInactive

Rental · Initial issue date Mar 30, 2017 · Terminal license date May 28, 2021

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 128 dated rows
  1. InvestigationL&I investigation

    Case CF-2026-003551 · PASSED

    The cited inspection visit was marked passed.

  2. ViolationBENCHMARKING LATE

    Case CF-2026-003551 · Violation VI-2026-002244 · Code 9-3402(2) · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  3. InvestigationL&I investigation

    Case CF-2026-003551 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  4. CertificationFire Alarm Certification

    Certification BC-2026-012060 · Certified

    Expires 2026-07-18

  5. CertificationFire Alarm Certification

    Certification BC-2026-012101 · Certified

    Expires 2026-07-18

  6. CertificationSpecial Hazards Certification

    Certification BC-2024-033128 · Certified

    Expires 2025-08-30

  7. CertificationFire Alarm Certification

    Certification BC-2024-019358 · Certified

    Expires 2025-06-27

  8. CertificationFire Alarm Certification

    Certification BC-2023-011507 · Certified

    Expires 2024-05-23

  9. CertificationFire Alarm Certification

    Certification BC-2023-026154 · Certified

    Expires 2024-05-22

  10. CertificationSprinkler Certification

    Certification BC-2024-018932 · Certified

    Expires 2024-05-11

  11. InvestigationL&I investigation

    Case CF-2022-056928 · PASSED

    The cited inspection visit was marked passed.

  12. CertificationSpecial Hazards Certification

    Certification BC-2022-010244 · Certified

    Expires 2023-07-08

  13. InvestigationL&I investigation

    Case CF-2022-056928 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  14. ViolationCOMMERCIAL COOKING SYSTEMS

    Case CF-2022-056928 · Violation VI-2022-043554 · Code F-904.12 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  15. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2022-056928 · Violation VI-2022-043553 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  16. ViolationPERIODIC TESTING

    Case CF-2022-056928 · Violation VI-2022-043555 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  17. InvestigationL&I investigation

    Case CF-2022-056928 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  18. CertificationFire Alarm Certification

    Certification BC-2023-002763 · Certified

    Expires 2023-06-10

  19. CertificationFire Alarm Certification

    Certification BC-2023-002764 · Certified

    Expires 2023-06-10

  20. PermitAddition and/or Alteration

    Permit EP-2022-002393 · Expired

    Replace receptacles and conduit from office and entry door. AS PER NEC 2017

  21. CertificationFire Alarm Certification

    Certification BC-2021-004725 · Certified

    Expires 2022-07-02

  22. License terminal eventMM FAIRMOUNT AVE PARTNERS LP: Rental landlord or residential registration marked inactive

    License 733694 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  23. PermitAlterations

    Permit PP-2020-003902 · Completed

    For Interior Plumbing work to include capping off 3 toilets & 3 lav sinks, Installing 2 floor sinks & 1 sink drain, as per 2018 Philadelphia Plumbing Code.

  24. PermitAddition and/or Alteration

    Permit CP-2020-000072 · Completed

    FOR LEVEL II ALTERATIONS TO AN EXISTING RESTAURANT ON THE GROUND FLOOR LEVEL FOR THE REMOVAL OF BATHROOM WITH THE INSTALLATION OF A RETAIL COUNTER ACCESSORY TO ASSEMBLY SPACE. ALTERATIONS TO INCLUDE ERECTION OF PARTITION WALLS, PROVIDE FINISHES, FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  25. PermitZoning/use

    Permit 935650 · COMPLETED

    FOR THE ERECTION OF ONE (1) FLAT NON ILLUMINATED WALL SIGN. FOR AN EXISTING SIT DOWN RESTAURANT (PERMIT NO. 847430) AS SHOWN IN THE ATTACHED PLANS.

  26. PermitAdministrative

    Permit 921314 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  27. PermitElectrical

    Permit 910630 · COMPLETED

    OUTLETS,SWITCHES,GFI'S,DEDICATED CIRCUITS AS PER PLANS AND 2008 NEC.**NO FIRE ALARM ON THIS PERMIT**

  28. PermitMechanical

    Permit 912759 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR FIRST FLOOR AND BASEMENT RESTAURANT AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR KITCHEN EXHAUST SYSTEM.

  29. PermitSuppression

    Permit 912400 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. RELOCATE FOUR (4) SPRINKLER HEADS

  30. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 622939 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  31. PermitPlumbing

    Permit 905993 · COMPLETED

    PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION & LEVEL 2 ALTERATIONS TO CREATE SIT-DOWN RESTAURANT/BAR; 6-WC,6-LAV,2-FLOOR DRAINS,4-KITCHEN SINKS AND 5-CATCH BASINS.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  32. PermitMajor alteration

    Permit 892972 · COMPLETED

    PARTIAL CHANGE OF OCCUPANCY CLASSIFICATION & LEVEL 2 ALTERATIONS TO CREATE SIT-DOWN RESTAURANT/BAR TENANT INCLUDING ERECTION OF PARTITION WALLS FOR TOILET ROOM, KITCHEN & SERVICE SPACES PER APPROVED PLANS; BUILDING IS FULLY SPRINKLERED. SEPARATE PERMIT REQ'D FOR INSTALLATION OF PRE-FABRICATED STAIRWAY ASSEMBLY (DEFERRED) & ANY MECH., ELEC., PLUMB., & FIRESUPP. WORK.

  33. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 622930 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  34. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 622930 · CLOSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.

  35. InvestigationCI INSP

    Case 622939 · CLOSED

    City marked the record closed; open the case for the closing reason.

  36. InvestigationCI INSP

    Case 622939 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  37. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 622930 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  38. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 622930 · Violation 4677757 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.

  39. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 622939 · Violation 4677766 · Code FC-13-915.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  40. ViolationPULL STATION SIGNS

    Case 622939 · Violation 4677765 · Code FC-13-907.51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  41. ViolationOPEN JUNCTION BOXES

    Case 622939 · Violation 4677764 · Code FC-13-605.6 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  42. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 622930 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  43. InvestigationCI INSP

    Case 622939 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  44. PermitUse

    Permit 847430 · COMPLETED

    USE OF THE GROUND FLOOR COMMERCIAL SPACE AS A SIT DOWN RESTAURANT ON THE ENTIRE FIRST FLOOR

  45. License issue eventMM FAIRMOUNT AVE PARTNERS LP: Rental landlord or residential registration initially issued

    License 733694 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  46. PermitSign

    Permit 738794 · COMPLETED

    FOR THE REMOVAL OF EXISTING SIGNAGE AND FOR THE ERECTION OF TWO (2) ACCESSORY NON-ILLUMINATED FLAT WALLS SIGNS AND THREE (3) WINDOW VINYL SIGNS. SIZE AND LOCATION AS SHOWN PER APPLICATION/PLAN. SIGNS ACCESSORY TO PREVIOUSLY APPROVED USE OF FINANCIAL SERVICES IN GROUND FLOOR RETIAL SPACE "A" (NWC OF FAIRMOUNT AVENUE & 17TH STREET) OF AN EXISTING BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS SEALED BY STRUCTURAL ENGINEER. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  47. PermitZoning/use

    Permit 738788 · COMPLETED

    FOR THE REMOVAL OF EXISTING SIGNAGE AND FOR THE ERECTION OF TWO (2) ACCESSORY NON-ILLUMINATED FLAT WALLS SIGNS AND THREE (3) WINDOW VINYL SIGNS. SIZE AND LOCATION AS SHOWN PER APPLICATION/PLAN. SIGNS ACCESSORY TO PREVIOUSLY APPROVED USE OF FINANCIAL SERVICES IN GROUND FLOOR RETIAL SPACE "A" (NWC OF FAIRMOUNT AVENUE & 17TH STREET) OF AN EXISTING BUILDING WITH OTHER USES AND PARKING AS PREVIOUSLY APPROVED.

  48. PermitZoning/use

    Permit 726845 · COMPLETED

    REPLACING TWO ILLUMINATED WALL SIGNS (A) 55 1/4" X 31'-4" AND REPLACING TWO FACES ON EXISTING PYLON SIGN 19 3/4" X 12'-0 AS PER PLANS.

  49. PermitSign

    Permit 726847 · COMPLETED

    REPLACING TWO ILLUMINATED WALL SIGNS (A) 55 1/4" X 31'-4" AND REPLACING TWO FACES ON EXISTING PYLON SIGN 19 3/4" X 12'-0 AS PER PLANS.

  50. PermitMechanical

    Permit 730388 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  51. PermitAdministrative

    Permit 717190 · COMPLETED

    FOR A CERTIFICATE OF OCCUPANCY FOR AN EXISTING BUILDING. OCCUPANCIES INCLUDE A MERCANTILE SPACE (SPACE 101), TWO (2) PERSONAL SERVICE FACILITIES (SPACES 201 & 202). PLANS FOR PERSONAL SERVICE SPACES PREVIOUSLY APPROVED UNDER PERMITS #657725 & 660011 (C.O. WAS NOT INCLUDED DUE TO NOT HAVING AN ACCESSIBLE ROUTE, WHICH HAS SINCE BEEN PROVIDED).

  52. PermitElectrical

    Permit 698915 · COMPLETED

    FIRE ALARM: ADD DEVICES TO EXISTING SYSTEM AS PER NFPA 72 CC DISTRICT

  53. PermitMajor alteration

    Permit 575018 · COMPLETED

    FOR SELECTIVE INTERIOR DEMOLITION AND LEVEL 3 ALTERATIONSTO UPDATE RESIDENTIAL UNITS. ALL UNITS TO BE TYPE B UNITS. BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS. **ALL ASBESTOS TO BE TREATED & REMOVED PRIOR TO COMMENCEMENT OF WORK.** SEPARATE PERMITS ALSO REQUIRED FOR RETAIL TENANT FIT-OUTS AND PARKING IMPROVEMENTS. SEE PERMIT #557625 FOR UPGRADES TO EXISTING BUILDING AND PRE-REQUISITE APPROVALS (SPECIAL INSPECTIONS, AIR, STRUCTURAL REPORTS, ENERGY, STREETS DEPT., WATER DEPT.). ELEVATOR SHAFTS TO MAINTAIN TWO (2) HOUR FIRE-RESISTANCE RATED CONSTRUCTION. ELEVATORS TO BE INSTALLED AT A FUTURE DATE.

  54. PermitNew Construction

    Permit 667886 · Expired

    WORK OUT SPACE, FIT OUT ON 2ND FLOOR EXISTING 200AMP 3 PHASE, PANEL 120V/208V INSTALLATION OF LIGHT FIXTURTES, EXIT/EMERGENCY SIGNS, DEDICATED LINES FOR GYM FIT OUT AS PER 2008 NEC (CC DISTRICT) NO FIRE ALARM ON THIS PERMIT

  55. PermitElectrical

    Permit 666363 · COMPLETED

    WIRE AND INSTALL OUTLETS AND LIGHTS PER 2008 NEC (COMMERICAL)CC DISTRICT*EXISTING SERVICE PANEL AND FIRE ALARM*

  56. PermitUse

    Permit 668643 · COMPLETED

    FOR USE AS RETAIL SALE OF CONSUMER GOODS IN SPACE '101', PERSONAL SERVICES IN SPACE '201', PERSONAL SERVICES IN SPACE '202', AND MULTI-FAMILY HOUSEHOLD LIVING (ELEVEN (11) DWELLING UNITS) ON FLOORS ABOVE. NO SIGNS ON THIS APPLICATION. NO SIGNS ON THIS PERMIT.

  57. PermitAlteration

    Permit 660011 · COMPLETED

    FOR PRESCRIPTIVE INTERIOR ALTERATIONS TO INSTALL NON-BEARING PARTITIONS AND TOILET ROOMS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS. PERMIT DOES NOT INCLUDE CERTIFICATE OF OCCUPANCY AS ACCESSIBLE ROUTE IS NOT PROVIDED AT THIS TIME.

  58. PermitMajor alteration

    Permit 657725 · COMPLETED

    FOR ALTERATIONS TO CREATE WALL BREACHES, ACCESSIBILITY UPGRADES, AND THE INSTALLATION OF ELEVATORS IN EXISTING SHAFTS AS SHOWN IN APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR TENANT SPACE FIT-OUTS AS WELL AS ALL MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS.

  59. PermitUse

    Permit 663513 · COMPLETED

    FOR A PERSONAL SERVICES AT SPACE # 201 AND SPACE # 202 AT SECOND FLOOR IN THE SAME BUILDING WITH ALL OTHER USES AS PREVIOUSLY APPROVED.NO SIGN ON THIS APPLICATION.

  60. PermitSign

    Permit 642496 · COMPLETED

    INSTALL FLATWALL SIGNS

  61. PermitElectrical

    Permit 645384 · COMPLETED

    FURNISH AND INSTALL NEW LIGHTING AND POWER PER 2008 NEC (BANK)INSTALL NEW FIRE ALARM SYSTEM TO TIE INTO EXISITNG BUILDING AND FIRE ALARM CONTROL PANEL PER NFPA 72*(SERVICE PROVIDED BY OTHERS)

  62. PermitPlumbing

    Permit 652887 · COMPLETED

    ROUGH (1) WC (1) LAV (1) KITCHEN SINK AND (1) MOP SINK (BANK)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  63. PermitSuppression

    Permit 650929 · COMPLETED

    RELOCATE 10 SPRINKLER HEADSIN 1ST FLOOR (BANK)

  64. PermitMechanical

    Permit 644870 · COMPLETED

    ELEVEN(11) HVAC SPLIT SYSTEMS (LINE SETS TO BE RUN ON EXTERIOR WALL)

  65. PermitSuppression

    Permit 633123 · COMPLETED

    INSTALL NFPA 13R SPRINKLER SYSTEM. RESIDENTIAL BLDG/MULTI-UNIT BLDG. 2" FEED MAIN. CODE/DESIGN PROF: PHIL SCONYO, PE

  66. ViolationPERMB- INSTALL DUCTWORK

    Case 575018 · Violation 3733642 · Code A-301.1/43 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  67. PermitPlumbing

    Permit 642353 · COMPLETED

    6" STORM & SANITARY LATERALS, HOUSE TRAP, FAI & 2" WATER - PA1# 2015-2581091 - "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  68. PermitElectrical

    Permit 630089 · COMPLETED

    INSTALL ALL POWER 2000AMP SERVICE COMPLETE, LIGHTING SWITCHES, RECEPTS, INTERCONNECTED SMOKES AND CO DETECTORS, TELE, CATV AS PER 2008 NEC (CC DISTRICT) NO COMMERCIAL SPACE ON THIS PERMIT INSTALL FIRE ALARM SYSTEM AS PER NFPA72

  69. PermitZoning/use

    Permit 631941 · COMPLETED

    THE APPLICATION IS FOR THE ERECTION OF TWO INTERNALLY ILLUMINATED FLAT WALL SIGNS ACCESSORY TO FINANCIAL SERVICE(BANK), IN THE FIRST FLOOR OF AN EXISTING ATTACHED STRUCTURE, WITH ALL OTHER PREVIOUS USES (SIZE AND LOCATION AS SHOWN IN THE APPLICATION).

  70. PermitUse

    Permit 630006 · COMPLETED

    FOR USE AS FINANCIAL SERVICES IN GROUND FLOOR RETAIL SPACE 'A' (NWC FAIRMOUNT AVE & 17TH ST) OF AN EXISTING BUILDING WITH OTHER USES AND PARKING AS PREVIOUSLY APPROVED. NO SIGNS ON THIS PERMIT.

  71. PermitMajor alteration

    Permit 624437 · COMPLETED

    LEVEL II ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO CREATE A BANK IN EXISTING FIRST FLOOR SHELL TENANT SPACE AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  72. PermitPlumbing

    Permit 622869 · COMPLETED

    INTERIOR PLUMBING ALTERATIONS THROUGHOUT FOR A RETAIL SPACE ON THE GROUND FLOOR AND (11)DWELLING UNITS IN AN EXISTING STRUCTURE - NOTE: EXTERIOR, BACKFLOW PREVENTION CONTAINMENT DEVICE, FUEL GAS & SEWER/WATER CONNECTIONS TO THE CITY MAINS REQUIRE SEPARATE PERMIT(S) - THE INSTALLATION WILL BE IN COMPLIANCE WITH THE PHILADELPHIA PLUMBING CODE 2004

  73. ViolationINSURANCE - POST CERT

    Case 557629 · Violation 3451844 · Code A-302.8/32 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  74. ViolationLIC MUST BE AVAIL FOR INSP

    Case 557629 · Violation 3451843 · Code A-302.8/31 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  75. PermitMajor alteration

    Permit 557629 · COMPLETED

    INTERIOR AND EXTERIOR STRUCTURAL/ARCHITECTURAL REMEDIATION AND STABILIZATION AND REHAB OF EXISTING VACANT 4 & 2 STORY SHELL STRUCTURES ONLY. LIFE SAFETY UPGRADES PRIOR TO INTERIOR FITOUTS. SELECTIVE INTERIOR/EXTERIOR DEMOLITION AND REPAIRS OF DAMAGED WALLS, NEW LINTELS, NEW FLOOR & ROOF FRAMING, STAIRS, NEW ROOF, AND ARCHITECTURAL FACADE AND EXTERIOR REHAB. STRUCTURAL FOUNDATION, FOOTINGS AND UNDERPINNING STABILIZATION WORK TO BE INSPECTED BY REGISTERED ENGINEER. SEPARATE SIDEWALK SHELTER PLATFORM PERMIT AND STREETS DEPARTMENT APPROVAL IS REQUIRED PRIOR TO INSTALLATION. SEPARATE ARCHITECTURAL FIT OUTS/ALTERATIONS AND CERTIFICATE OF OCCUPANCY PERMITS REQUIRED **AS NOTED/IDENTIFIED ON PLANS ARCHITECTURAL REFERENCES FOR FUTURE WORK ONLY, NOT REVIEWED FOR CODE COMPLIANCE - INCLUDING ALL CIVIL/SITE AND PARKING LOT FOR REFERENCE ONLY(NOT APPROVED OR REVIEWED)** ADDITIONAL PERMITS FOR FITOUTS - CO & FIT OUTS, ELECTRICAL, PLUMBING, HVAC, SPRINKLERS, SIGNS AND SPECIAL INSPECTION AGENCY WILL BE REQUIRED.

  76. PermitAlteration

    Permit 549406 · COMPLETED

    CLEAN AND CLOSE IN PLACE TWO HEATING OIL TANKS WITHIN BUILDING, LOCATION SHOWN WITH IN THE BUILDING.

  77. PermitZoning admin review

    Permit 547320 · COMPLETED

    EXTENSION OF PERMIT # 513173 PURSUANT TO PA ACT 46 OF 2010 AS MODIFIED BY ACT 87 OF 2012. THIS EXTENSION TO EXPIRE ON JULY 1, 2016 UNLESS EXTENDED BY OTHER PORTIONS OF THE PHILADELPHIA CODE. CONTACT DISTRICT OFFICE TO INSTITUTE THE REQUIRED INSPECTIONS.

  78. PermitUse

    Permit 513173 · COMPLETED

    FOR THREE (3) VACANT COMMERCIAL SPACES (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) ON GROUND FLOOR AND TWELVE (12) INTERIOR PARKING SPACES INCLUDING TWO (2) HANDICAP ACCESSIBLE PARKING ON GROUND FLOOR AND SEVEN (7) ACCESSORY OPEN AIR PARKING SPACES (TOTAL 19 PARKING SPACES); RETAIL STORES ACCESSORY STORAGE IN BASEMENT; VACANT COMMERCIAL SPACES (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) AND THREE (3) FAMILY DWELLING ON SECOND FLOOR; FOUR (4) FAMILY DWELLINGS ON EACH THIRD AND FOURTH FLOORS (TOTAL ELEVEN (11) MULTIFAMILY HOUSEHOLD LIVING UNITS) IN THE SAME EXISTING BUILDING. NO SIGN ON THIS PERMIT.

  79. PermitZoning

    Permit 502899 · COMPLETED

    RELOCATION OF LOT LINE TO CREATE ONE (1) LOT FROM FIVE (5) DEEDED LOTS (1626, 1628, 1630, 1632-40 AND 1642-44 FAIRMOUNT AVE). SIZE AND LOCATION AS SHOWN ON THE APPLICATION

  80. PermitZoning

    Permit 505932 · COMPLETED

    RELOCATION OF LOT LINE TO CREATE ONE (1) LOT FROM FIVE (5) DEEDED LOTS (1626, 1628, 1630, 1632-40 AND 1642-44 FAIRMOUNT AVE). SIZE AND LOCATION AS SHOWN ON THE APPLICATION

  81. PermitZoning

    Permit 505933 · COMPLETED

    RELOCATION OF LOT LINE TO CREATE ONE (1) LOT FROM FIVE (5) DEEDED LOTS (1626, 1628, 1630, 1632-40 AND 1642-44 FAIRMOUNT AVE). SIZE AND LOCATION AS SHOWN ON THE APPLICATION

  82. PermitZoning

    Permit 505934 · COMPLETED

    RELOCATION OF LOT LINE TO CREATE ONE (1) LOT FROM FIVE (5) DEEDED LOTS (1626, 1628, 1630, 1632-40 AND 1642-44 FAIRMOUNT AVE). SIZE AND LOCATION AS SHOWN ON THE APPLICATION

  83. PermitZoning

    Permit 505935 · COMPLETED

    RELOCATION OF LOT LINE TO CREATE ONE (1) LOT FROM FIVE (5) DEEDED LOTS (1626, 1628, 1630, 1632-40 AND 1642-44 FAIRMOUNT AVE). SIZE AND LOCATION AS SHOWN ON THE APPLICATION

  84. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 368134 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  85. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 368132 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  86. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 368132 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  87. InvestigationBC INSP (likely: building-code inspection)

    Case 368134 · CLOSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.

  88. InvestigationBC INSP (likely: building-code inspection)

    Case 368134 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  89. InvestigationBC INSP (likely: building-code inspection)

    Case 368132 · CLOSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.

  90. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 367254 · CLOSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.

  91. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 367254 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  92. InvestigationBC INSP (likely: building-code inspection)

    Case 368132 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  93. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 367255 · CLOSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.

  94. ViolationPERM Z- NEW USE

    Case 368132 · Violation 2889214 · Code A-301.1/65 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  95. ViolationPERM Z- NEW USE

    Case 368134 · Violation 2877262 · Code A-301.1/65 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  96. InvestigationBC INSP (likely: building-code inspection)

    Case 368134 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  97. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 318373 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  98. InvestigationBC INSP (likely: building-code inspection)

    Case 368132 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  99. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 318364 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  100. ViolationLICENSE-VAC LOT

    Case 367254 · Violation 2787857 · Code PM-102.4/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  101. ViolationLICENSE-VAC LOT

    Case 367255 · Violation 2700090 · Code PM-102.4/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  102. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 367254 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  103. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 367255 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  104. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 318373 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  105. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 318364 · CLOSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.

  106. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 318373 · CLOSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.

  107. ViolationEXT S-CORNICE BARGEBOARD DEFEC

    Case 318364 · Violation 2477174 · Code PM-304.5/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  108. ViolationLICENSE-VAC COMM BLDG

    Case 318364 · Violation 2477173 · Code PM-102.4/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  109. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 318364 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  110. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 318373 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  111. ViolationLICENSE-VAC COMM BLDG

    Case 318373 · Violation 2669009 · Code PM-102.4/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  112. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 318373 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  113. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 318364 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  114. InvestigationCSUINITIAL

    Case 237734 · PASSED

    The cited inspection visit was marked passed.

  115. InvestigationCSUINITIAL

    Case 237734 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  116. PermitMajor alteration

    Permit 332311 · COMPLETED

    REPAIR NON BEARING, MASONRY WALL AT EAST SIDE OF STRUCTURE. LIMITED AREAS OF REPLACEMENT CMU TO BE PERFORMED.

  117. InvestigationCSUINITIAL

    Case 237734 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  118. InvestigationCSUINITIAL

    Case 237734 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  119. AppealRB_LIRB

    Appeal 11823 · CLOSED · Withdrawn

    Related permit 234947 · AN INDEPENDENT MASON HAS CHECKED THE ENTIRE FRONT AND SIDE OF THE BUILDING, INCLUDING THE SOFFIT AREA. HE FOUND NO ROOF PROBLEMS.

  120. ViolationWALL FRACTURED

    Case 237734 · Violation 2209506 · Code PM-307.1/9 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  121. ViolationARCHITECT/ENGINEER SERVICES

    Case 237734 · Violation 2209504 · Code A-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  122. ViolationWALL DETERIORATED

    Case 237734 · Violation 2209505 · Code PM-307.1/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  123. InvestigationCSUINITIAL

    Case 237734 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  124. InvestigationCSUINITIAL

    Case 234947 · PASSED

    The cited inspection visit was marked passed.

  125. ViolationROOF PARTIALLY COLLAPSED

    Case 234947 · Violation 1681579 · Code PM-307.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  126. InvestigationCSUINITIAL

    Case 234947 · PASSED

    The cited inspection visit was marked passed.

  127. InvestigationCSUINITIAL

    Case 234947 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  128. InvestigationL_INITIAL

    Case 30070 · CLOSED

    City marked the record closed; open the case for the closing reason.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 12:52 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)