Commercial property report

180 W Girard Ave

Research this property with Analyst →

2 stories84,826 sqftCMX3built 2011

Property at a glanceStore

Sup I Schmidts LLC

2026 assessment
$12M OPA value, not a listing price
2027 published assessment
$12M Future roll, not the current tax bill
Neighborhood area
Northern Liberties · Callowhill Approximate · based on ZIP 19123
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar
Open L&I record

2 violation rows marked OPEN in 2 active cases

The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.

Open City history ↗
Case CF-2022-019951

Inspection, Testing & Maintenance

IN VIOLATION

Opened Mar 11, 2022 · Latest inspection FAILED · Aug 25, 2024

  • Inspection, Testing & MaintenanceF-901.6
Case CF-2024-116690

Fdc Locking Caps

IN VIOLATION - COURT

Opened Nov 1, 2024 · Latest inspection FAILED · Jan 15, 2025

  • Fdc Locking CapsF-912.4.1

OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $11,790,800. It is not yet the billed-year tax basis.

$0$13M$25M$12M200820122016202020242027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record303 events · exact dates, newest first
  1. PermitAddition and/or Alterations
  2. LicenseTHE SHAKE SEAFOOD: Food Preparing and Serving (30+ SEATS) business license marked inactive
  3. PermitAddition and/or Alteration
  4. PermitSign
  5. PermitAddition and/or Alterations
  6. PermitAlterations
  7. PermitSigns (Accessory / Non-Accessory)
  8. PermitAddition and/or Alteration
  9. PermitAddition and/or Alteration
  10. CertificationSprinkler Certification
  11. LicenseGBC Food Services LLC (Yummi Sushi): Food Preparing and Serving business license marked inactive
  12. PermitAddition and/or Alteration
  13. InspectionL&I investigation
  14. L&I violationACCESS TO A PUBLIC WAY
  15. InspectionL&I investigation
  16. CertificationSpecial Hazards Certification
  17. LicenseSushi Maru Express, Inc.: Food Preparing and Serving business license initially issued
  18. PermitSign
  19. PermitSign
  20. PermitSigns (Accessory / Non-Accessory)
  21. CertificationSpecial Hazards Certification
  22. PermitSigns (Accessory / Non-Accessory)
  23. InspectionL&I investigation
  24. InspectionL&I investigation
  25. InspectionL&I investigation
  26. InspectionL&I investigation
  27. InspectionL&I investigation
  28. InspectionL&I investigation
  29. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  30. L&I violationPERIODIC TESTING
  31. L&I violationFDC LOCKING CAPS
  32. CertificationSprinkler Certification
  33. InspectionL&I investigation
  34. InspectionL&I investigation
  35. InspectionL&I investigation
  36. L&I violationFDC LOCKING CAPS
  37. CertificationSpecial Hazards Certification
  38. PermitAddition and/or Alteration
  39. PermitSign
  40. CertificationSprinkler Certification
  41. CertificationFire Alarm Certification
  42. InspectionL&I investigation
  43. PermitSigns (Accessory / Non-Accessory)
  44. PermitNew Construction
  45. InspectionL&I investigation
  46. CertificationSprinkler Certification
  47. L&I violationINTERIOR SURFACES
  48. L&I violationELEVATORS
  49. InspectionL&I investigation
  50. PermitAddition and/or Alteration
  51. PermitAddition and/or Alteration
  52. PermitAddition and/or Alteration
  53. L&I violationFAIL OBTAIN LICENSE (Obtain the license identified in the notice)
  54. L&I violationPERIODIC TESTING
  55. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  56. L&I violationINSPECTION, TESTING & MAINTENANCE
  57. InspectionL&I investigation
  58. PermitSign
  59. PermitAddition and/or Alterations
  60. PermitAddition and/or Alterations
  61. PermitAlterations
  62. PermitAddition and/or Alteration
  63. PermitAddition and/or Alterations
  64. PermitAddition and/or Alteration
  65. PermitSigns (Accessory / Non-Accessory)
  66. InspectionL&I investigation
  67. AppealZBA Permit Denial - Variance
  68. PermitChange of Use
  69. CertificationFire Alarm Certification
  70. PermitAddition and/or Alteration
  71. LicenseTHE SHAKE SEAFOOD: Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive
  72. LicenseTHE SHAKE SEAFOOD: Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued
  73. LicenseFAMILY DOLLAR STORES OF PA INC (TAX AND LICENSE DEPT.): Food Establishment, Retail Perm Location (Large) business license marked inactive
  74. CertificationSprinkler Certification
  75. InspectionL&I investigation
  76. LicenseTHE SHAKE SEAFOOD: Food Preparing and Serving (30+ SEATS) business license initially issued
  77. InspectionL&I investigation
  78. L&I violationINSPECTION, TESTING & MAINTENANCE
  79. PermitNew Construction
  80. CertificationFire Alarm Certification
  81. CertificationSprinkler Certification
  82. CertificationSprinkler Certification
  83. PermitAddition and/or Alterations
  84. PermitSign
  85. PermitSigns (Accessory / Non-Accessory)
  86. PermitSigns (Accessory / Non-Accessory)
  87. PermitNew Construction
  88. InspectionL&I investigation
  89. PermitAddition and/or Alteration
  90. PermitAddition and/or Alteration
  91. PermitAddition and/or Alterations
  92. InspectionL&I investigation
  93. PermitAlterations
  94. PermitAddition and/or Alterations
  95. PermitRough-In
  96. PermitAddition and/or Alterations
  97. PermitChange of Use
  98. PermitAddition and/or Alteration
  99. AppealZBA Permit Denial - Special Exception
  100. InspectionL&I investigation
  101. L&I violationMEANS OF EGRESS ILLUMINATION
  102. L&I violationEXIT SIGN ILLUMINATION
  103. L&I violationEGRESS READILY OPENABLE
  104. L&I violationFIRE DOORS CLOSE/LATCH
  105. LicenseGBC Food Services LLC (Yummi Sushi): Food Preparing and Serving business license initially issued
  106. InspectionL&I investigation
  107. InspectionL&I investigation
  108. L&I violationUNSAFE STRUCTURE
  109. L&I violationSTEEL COMPONENTS
  110. L&I violationEXTERIOR FLOORING
  111. InspectionL&I investigation
  112. InspectionL&I investigation
  113. L&I violationEXTERIOR STRUCTURE STAIRS, DECKS, PORCHES
  114. PermitElectrical
  115. PermitPlumbing
  116. PermitElectrical
  117. PermitSuppression
  118. PermitZoning/use
  119. PermitMajor alteration
  120. PermitUse
  121. InspectionBP_BLDG
  122. PermitPlumbing
  123. L&I violationPERMP- ALTER/REPAIR/REPL PLUMB
  124. L&I violationPERMB- INSTALL HVAC SYS
  125. L&I violationPERME- ALTER ELEC INSTALLATION
  126. InspectionBP_BLDG
  127. PermitElectrical
  128. PermitSuppression
  129. PermitZoning/use
  130. PermitSign
  131. PermitMajor alteration
  132. PermitUse
  133. PermitElectrical
  134. PermitMajor alteration
  135. PermitMechanical
  136. InspectionPRECOURT (likely: pre-court compliance inspection)
  137. InspectionCI INSP
  138. PermitMajor alteration
  139. PermitUse
  140. InspectionPRECOURT (likely: pre-court compliance inspection)
  141. InspectionCI INSP
  142. InspectionCI INSP
  143. PermitMechanical
  144. L&I violationEXTERIOR STRUCT PROTECTIVE TRE
  145. L&I violationGENERAL REQ.- CITE CODE SECTIO
  146. L&I violationFIRE SUPPRESSION CERTIFICATION
  147. InspectionCI INSP
  148. PermitPlumbing
  149. PermitElectrical
  150. PermitSuppression
  151. PermitMajor alteration
  152. InspectionBC INSP (likely: building-code inspection)
  153. InspectionBC INSP (likely: building-code inspection)
  154. InspectionBC INSP (likely: building-code inspection)
  155. InspectionBC INSP (likely: building-code inspection)
  156. InspectionBC INSP (likely: building-code inspection)
  157. L&I violationVENDOR ST NUISANCE AH
  158. L&I violationVENDOR ST NUISANCE AH
  159. L&I violationVENDOR ST NUISANCE AH
  160. L&I violationVENDOR ST NUISANCE AH
  161. L&I violationVENDOR ST NUISANCE AH
  162. InspectionBC INSP (likely: building-code inspection)
  163. InspectionBC INSP (likely: building-code inspection)
  164. InspectionBC INSP (likely: building-code inspection)
  165. InspectionBC INSP (likely: building-code inspection)
  166. InspectionBC INSP (likely: building-code inspection)
  167. LicenseSUPER FRESH FOOD MARKET (SUSAN KIJOWSKI): Food Establishment, Retail Perm Location (Large) business license marked inactive
  168. LicenseGRACE HEE KIM (FRESH KING SUSHI): Food Preparing and Serving business license marked inactive
  169. PermitSuppression
  170. PermitMajor alteration
  171. PermitSign
  172. InspectionPRECOURT (likely: pre-court compliance inspection)
  173. InspectionPRECOURT (likely: pre-court compliance inspection)
  174. PermitElectrical
  175. PermitElectrical
  176. PermitZoning/use
  177. PermitSuppression
  178. PermitElectrical
  179. PermitElectrical
  180. PermitElectrical
  181. LicenseFAMILY DOLLAR STORES OF PA INC (TAX AND LICENSE DEPT.): Food Establishment, Retail Perm Location (Large) business license initially issued
  182. PermitSuppression
  183. PermitElectrical
  184. PermitMechanical
  185. PermitMajor alteration
  186. LicenseGRACE HEE KIM (FRESH KING SUSHI): Food Preparing and Serving business license initially issued
  187. PermitMajor alteration
  188. PermitMechanical
  189. PermitSign
  190. PermitSign
  191. L&I violationINSURANCE - POST CERT
  192. PermitUse
  193. PermitPlumbing
  194. PermitPlumbing
  195. PermitZoning/use
  196. PermitZoning/use
  197. InspectionCI INSP
  198. PermitSuppression
  199. PermitElectrical
  200. InspectionCI INSP
  201. L&I violationANNUAL CERT FIRE ALARM
  202. L&I violationANNUAL CERT FIRE SUPP
  203. InspectionCI INSP
  204. PermitElectrical
  205. PermitPlumbing
  206. PermitMechanical
  207. PermitMajor alteration
  208. PermitUse
  209. InspectionPRECOURT (likely: pre-court compliance inspection)
  210. PermitSuppression
  211. PermitSuppression
  212. L&I violationPERM - MUST POST
  213. PermitPlumbing
  214. PermitMajor alteration
  215. PermitMechanical
  216. PermitSign
  217. PermitZoning/use
  218. PermitUse
  219. InspectionBP_BLDG
  220. InspectionBP_BLDG
  221. PermitElectrical
  222. L&I violationPERMZ- OR REMOVE ADVERTISING
  223. L&I violationPERMB- FLAT WALL SIGN
  224. L&I violationPENALTY- NO BLDG PERM INFO
  225. InspectionBP_BLDG
  226. PermitElectrical
  227. PermitMechanical
  228. PermitPlumbing
  229. PermitSuppression
  230. PermitMajor alteration
  231. PermitUse
  232. PermitSign
  233. PermitZoning/use
  234. PermitMechanical
  235. LicenseFAMILY DOLLAR STORES OF PA, INC: Dumpster License - Private Property L&I license filing initially issued
  236. PermitElectrical
  237. PermitZoning/use
  238. PermitSign
  239. PermitSuppression
  240. InspectionCI INSP
  241. PermitMajor alteration
  242. PermitElectrical
  243. PermitElectrical
  244. PermitElectrical
  245. PermitUse
  246. PermitPlumbing
  247. PermitMechanical
  248. PermitSuppression
  249. PermitAdministrative
  250. PermitElectrical
  251. InspectionCI INSP
  252. L&I violationFIRE LANE MARKED
  253. L&I violationFIRE LANE PROHIB CONT ACCESS
  254. L&I violationVIOL C&I MESSAGE
  255. InspectionCI INSP
  256. LicenseSUPER FRESH FOOD MARKET (SUSAN KIJOWSKI): Food Establishment, Retail Perm Location (Large) business license initially issued
  257. PermitElectrical
  258. PermitSuppression
  259. PermitSign
  260. PermitPlumbing
  261. PermitMajor alteration
  262. PermitMechanical
  263. PermitZoning/use
  264. PermitZoning/use
  265. PermitMajor alteration
  266. PermitZoning
  267. PermitUse
  268. PermitElectrical
  269. AppealZoning board appeal
  270. InspectionBP_BLDG
  271. InspectionBP_BLDG
  272. PermitUse
  273. InspectionBP_BLDG
  274. PermitMechanical
  275. PermitAdministrative
  276. PermitAdministrative
  277. L&I violationPERMB- FLAT WALL SIGN
  278. InspectionBP_BLDG
  279. AppealBuilding standards appeal
  280. PermitSuppression
  281. PermitMechanical
  282. PermitMajor alteration
  283. L&I violationPERMB- INSTALL HVAC SYS
  284. L&I violationPERMB- ALTER REPAIR INT PART (Building permit required for interior alteration or repair)
  285. L&I violationLISTED CONDIT DOES NOT COMPLY
  286. InspectionBP_BLDG
  287. PermitElectrical
  288. PermitSuppression
  289. PermitElectrical
  290. PermitPlumbing
  291. PermitNew construction
  292. InspectionBP_BLDG
  293. PermitAdministrative
  294. InspectionBP_BLDG
  295. PermitZoning/use
  296. PermitZoning/use
  297. L&I violationPERMB- CONST FOUNDATION
  298. L&I violationPENALTY- NO BLDG PERM INFO
  299. L&I violationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)
  300. InspectionBP_BLDG
  301. PermitZoning
  302. L&I violationCLIP VIOLATION NOTICE
  303. L&I violationVACANT LOT KEEP CLEAN GET LIC

Verify the public record

$165,048/year estimated property tax

2026 taxable assessment $11,790,800 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $11,790,800. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 882932476
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Store, recorded in the City's commercial category. The public record and owner trail follow.

1 open violation

What it is
Store Shop Cent N'Hood Masonry
Owner
Sup I Schmidts LLC
$ / sq ft
$139 below the $151 median for 7,668 commercial parcels citywide
Corridor
2nd and Girard city commercial corridor
Interior area
84,826 sqft
Lot size
129,514 sqft
Stories
2
Built
2011
Zoning
CMX3

Recorded owner

Who's behind it

Sup I Schmidts LLC · corporate / LLC owner

• Tax bills mail to 340 Royal Poinciana Way, Palm Beach FL, 33480 — outside Philadelphia

Block context

100 block of W Girard Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 160 W Girard Ave  ·  154-58 W Girard Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
Sushi Maru Express, Inc.Active

Food Preparing and Serving · Initial issue date Aug 29, 2025 · Filed expiration Aug 28, 2026

THE SHAKE SEAFOODInactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Apr 14, 2022 · Terminal license date Jun 12, 2026

GBC Food Services LLC (Yummi Sushi)Inactive

Food Preparing and Serving · Initial issue date Oct 7, 2020 · Terminal license date Dec 5, 2025

FAMILY DOLLAR STORES OF PA INC (TAX AND LICENSE DEPT.)Inactive

Food Establishment, Retail Perm Location (Large) · Initial issue date Jul 9, 2014 · Terminal license date Jun 29, 2022

GRACE HEE KIM (FRESH KING SUSHI)Inactive

Food Preparing and Serving · Initial issue date Jun 5, 2014 · Terminal license date Jun 29, 2015

SUPER FRESH FOOD MARKET (SUSAN KIJOWSKI)Inactive

Food Establishment, Retail Perm Location (Large) · Initial issue date Sep 6, 2011 · Terminal license date Jun 29, 2016

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Inferred from public records · 2025-07-30 through 2026-07-30

Food and drink at this property

1 possible-opening record signal in this 12-month window. These are classifications, not confirmed announcements.

Inference, not an opening announcement. Possible-opening classifications are inferences from public permit and license records, not confirmed opening announcements. A permit is authorization for a stated scope, not proof that work occurred or finished. A license is an L&I registration, not proof that a business is open or operating. Food and drink uses the seven exact L&I license types already used by BlockReport. The City record does not support a reliable restaurant, bar, and cafe split. License renewals do not create new events. The opening date is the earliest initial issue date for a deduped OPA parcel, normalized business identity, and license type. Sources: L&I building permits and L&I business licenses, data through Jul 30, 2026.

Open every source row 303 dated rows
  1. PermitAddition and/or Alterations

    Permit FP-2026-001177 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 8 existing sprinkler heads for renovations in 2nd level of Acme

  2. License terminal eventTHE SHAKE SEAFOOD: Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 892203 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  3. PermitAddition and/or Alteration

    Permit EP-2026-003572 · Completed

    Connect (1) new wall sign to existing sign circuit. No new wiring for building permit involved. General Permit #GP-2026-000168.

  4. PermitSign

    Permit GP-2026-000168 · Completed

    FOR THE INSTALLATION OF ONE (1) NON-ILLUMINATED ACCESSORY WALL SIGN

  5. PermitAddition and/or Alterations

    Permit MP-2026-000382 · Issued

    FOR A MECHANICAL WORK TO ACCOMMODATE AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.

  6. PermitAlterations

    Permit PP-2026-000796 · Issued

    Replace existing bathroom fixtures and a new water fountain. Install various drains and a grease interceptor for new cheese area and floral department. Replace various sinks around the store.

  7. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2026-000202 · Completed

    FOR ERECTION OF ONE (1) NON-ILLUMINATED ACCESSORY FLAT WALL SIGN WITH MURAL ON EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLAN.

  8. PermitAddition and/or Alteration

    Permit EP-2026-000555 · Issued

    Interior alteration including lighting, wiring devices and refrigeration equipment. All work to be done according to the 2017 NEC and per approved plans.

  9. PermitAddition and/or Alteration

    Permit CP-2026-000212 · Issued

    FOR LEVEL II INTERIOR ALTERATIONS WITHOUT A CHANGE IN USE AND OCCUPANCY CLASSIFICATION TO AN EXISTING GROUP M RETAIL GROCERY STORE. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK.

  10. CertificationSprinkler Certification

    Certification BC-2026-003538 · Deficient

  11. License terminal eventGBC Food Services LLC (Yummi Sushi): Food Preparing and Serving business license marked inactive

    License 853040 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  12. PermitAddition and/or Alteration

    Permit EP-2025-009466 · Completed

    Provide 120V circuit to entrance way blade sign only. 100' of conduit and wire for entrance way blade sign. Permit is for sign only. Make connection to panel with 20A breaker

  13. InvestigationL&I investigation

    Case CF-2025-106492 · PASSED

    The cited inspection visit was marked passed.

  14. ViolationACCESS TO A PUBLIC WAY

    Case CF-2025-106492 · Violation VI-2025-076243 · Code F-1028.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  15. InvestigationL&I investigation

    Case CF-2025-106492 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. CertificationSpecial Hazards Certification

    Certification BC-2025-023844 · Certified

    Expires 2026-09-03

  17. License issue eventSushi Maru Express, Inc.: Food Preparing and Serving business license initially issued

    License 0987567 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  18. PermitSign

    Permit GP-2025-004272 · Issued

    FOR THE INSTALLATION OF TWO (2) DOUBLE-FACED PROJECTING SIGNS WITH STATIC ILLUMINATION AND ONE (1) FLAT WALL SIGN WITH STATIC ILLUMINATION PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR THE ELECTRICAL WORK.

  19. PermitSign

    Permit GP-2025-004997 · Completed

    FOR THE INSTALLATION OF TWO (2) STATICALLY-ILLUMINATED ACCESSORY WALL SIGNS PER APPROVED PLANS.

  20. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2025-004598 · Issued

    FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATE WALL SIGN AND TWO (2) STATICALLY ILLUMINATED PROJECTING SIGNS. SIZE AND LOCATION AS SHOWN IN PLAN.

  21. CertificationSpecial Hazards Certification

    Certification BC-2025-014897 · Certified

    Expires 2026-05-29

  22. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2025-003360 · Completed

    FOR THE REMOVAL OF TWO (2) WALL SIGNS AND THE INSTALLATION OF TWO (2) STATICALLY ILLUMINATED WALL SIGNS. SIZE AND LOCATION AS SHOWN IN THE APPLICATION / PLANS.

  23. InvestigationL&I investigation

    Case CF-2023-073779 · PASSED

    The cited inspection visit was marked passed.

  24. InvestigationL&I investigation

    Case CF-2020-086552 · PASSED

    The cited inspection visit was marked passed.

  25. InvestigationL&I investigation

    Case CF-2024-116690 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  26. InvestigationL&I investigation

    Case CF-2024-116690 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  27. InvestigationL&I investigation

    Case CF-2024-116690 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  28. InvestigationL&I investigation

    Case CF-2024-084885 · PASSED

    The cited inspection visit was marked passed.

  29. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2024-116690 · Violation VI-2024-089496 · Code F-903.5 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  30. ViolationPERIODIC TESTING

    Case CF-2024-116690 · Violation VI-2024-089497 · Code F-901.6.4 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  31. ViolationFDC LOCKING CAPS

    Case CF-2024-116690 · Violation VI-2024-089495 · Code F-912.4.1 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  32. CertificationSprinkler Certification

    Certification BC-2024-030199 · Certified

    Expires 2025-10-30

  33. InvestigationL&I investigation

    Case CF-2024-084885 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  34. InvestigationL&I investigation

    Case CF-2022-019951 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  35. InvestigationL&I investigation

    Case CF-2024-084885 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  36. ViolationFDC LOCKING CAPS

    Case CF-2024-084885 · Violation VI-2024-065963 · Code F-912.4.1 · CLOSED

    Resolution: CLOSED - REISSUED/REWRITTEN City marked the record closed; open the case for the closing reason.

  37. CertificationSpecial Hazards Certification

    Certification BC-2024-017392 · Certified

    Expires 2025-05-31

  38. PermitAddition and/or Alteration

    Permit EP-2024-000137 · Expired

    100' of conduit and wire for entrance way blade sign PERMIT IS FOR SIGN POWER ONLY

  39. PermitSign

    Permit GP-2023-010535 · Completed

    FOR THE INSTALLATION OF ONE (1) STATIC INTERNALLY ILLUMINATED ACCESSORY DOUBLE-FACED PROJECTING SIGN. **SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL WORK**

  40. CertificationSprinkler Certification

    Certification BC-2024-007190 · Deficient

  41. CertificationFire Alarm Certification

    Certification BC-2024-007189 · Deficient

  42. InvestigationL&I investigation

    Case CF-2023-101773 · PASSED

    The cited inspection visit was marked passed.

  43. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2023-007561 · Issued

    FOR THE ERECTION OF ONE (1) STATIC INTERNALLY ILLUMINATED ACCESSORY DOUBLE-FACED PROJECTING SIGN. SIZE AND LOCATION AS SHOWN ON PLANS.

  44. PermitNew Construction

    Permit EP-2022-008884 · Completed

    Install new electrical service and panels in tenant 1,and remove circuits from tenant 2 (both shell spaces)-2017 nec. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS. ** SEPARATE ELECTRICAL PERMITS REQUIRED FOR FITOUTS**

  45. InvestigationL&I investigation

    Case CF-2023-073779 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  46. CertificationSprinkler Certification

    Certification BC-2023-022743 · Certified

    Expires 2024-10-06

  47. ViolationINTERIOR SURFACES

    Case CF-2023-101773 · Violation VI-2023-075609 · Code PM15-305.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  48. ViolationELEVATORS

    Case CF-2023-101773 · Violation VI-2023-075610 · Code PM15-606.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  49. InvestigationL&I investigation

    Case CF-2023-101773 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  50. PermitAddition and/or Alteration

    Permit EP-2023-006311 · Issued

    Fire pump electrical connections, replace in kind. This electrical permit application is in connection to the fire suppression permit FP-2023-000816 diesel engine fire pump,wire electric motor jockey pump. Certify all fire pump monitoring is tied into fire alarm system. Location is in pump room located at the Acme loading dock through the parking garage As per NFPA 72

  51. PermitAddition and/or Alteration

    Permit EP-2023-007872 · Completed

    Tele Data cabling as per attached drawings. All cabling to be plenum rated less than 200' drops. AS PER NEC 2017

  52. PermitAddition and/or Alteration

    Permit EP-2023-007234 · Completed

    INSTALLING A NEW FIRE ALARM POWER SUPPLY AND FIRE ALRM DEVICES TO THE EXISTING BUILDING FIRE ALARM SYSTEM. ALL WORK IN ACCORDANCE WITH THE 2017 NEC & 2016 NFPA-72. Total Contract is $235,500 Electric Value - $219,500 - Permit # EP2023-003542 Fire Alarm Value - $16,000

  53. ViolationFAIL OBTAIN LICENSE (Obtain the license identified in the notice)

    Case CF-2023-073779 · Violation VI-2023-055321 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  54. ViolationPERIODIC TESTING

    Case CF-2023-073779 · Violation VI-2023-055318 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  55. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2023-073779 · Violation VI-2023-055319 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.

  56. ViolationINSPECTION, TESTING & MAINTENANCE

    Case CF-2023-073779 · Violation VI-2023-055320 · Code F-901.6 · COMPLIED

    Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.

  57. InvestigationL&I investigation

    Case CF-2023-073779 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  58. PermitSign

    Permit GP-2023-002729 · Expired

    FOR THE CONSTRUCTION OF TWO (2) ACCESSORY FLAT WALLS SIGNS (STATIC ILLUMINATION). FOR USE AS PREVIOUSLY APPROVED. AS PER APPROVED PLANS.

  59. PermitAddition and/or Alterations

    Permit FP-2023-000816 · Completed

    TO INSTALL A NEW FIRE PUMP INTO AN EXISTING SYSTEM OF NFPA-13 FIRE SERVICE. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  60. PermitAddition and/or Alterations

    Permit FP-2023-001036 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans.

  61. PermitAlterations

    Permit PP-2023-005234 · Completed

    Plumbing Permit (Interior) for combo CP-2023-000272

  62. PermitAddition and/or Alteration

    Permit EP-2023-003542 · Completed

    Electrical Permit for combo CP-2023-000272

  63. PermitAddition and/or Alterations

    Permit MP-2023-001761 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2023-000272

  64. PermitAddition and/or Alteration

    Permit CP-2023-000272 · Completed

    FOR A LEVEL II ALTERATIONS TO A PORTION OF THE FIRST FLOOR (SPACE 102A) OF AN EXISTING STRUCTURE. FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**SIGN NOT APPROVED ON THIS PERMIT**

  65. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2023-000686 · Issued

    FOR THE ERECTION OF TWO (2) ACCESSORY FLAT WALLS SIGNS (STATIC ILLUMINATION). SIZE AND LOCATION AS SHOWN PER APPLICATION/PLAN.

  66. InvestigationL&I investigation

    Case CF-2022-019951 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  67. AppealZBA Permit Denial - Variance

    Appeal ZP-2022-007213 · Completed · Granted with conditions

    Related permit ZP-2022-007213 · PERMIT FOR USE ANIMAL SERVICES - BOARDING AND OTHER SERVICES

  68. PermitChange of Use

    Permit ZP-2022-007213 · Issued

    Animal Services - Boarding and Other Services

  69. CertificationFire Alarm Certification

    Certification BC-2023-019821 · Certified

    Expires 2023-12-07

  70. PermitAddition and/or Alteration

    Permit CP-2022-004347 · Expired

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CREATE TWO (2) SHELL TENANT SPACES (SUITES 102A & 102B - SEPARATE USE REGISTRATION AND FIT-OUT PERMITS REQUIRED PRIOR TO OCCUPANCY) ON THE GROUND FLOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  71. License terminal eventTHE SHAKE SEAFOOD: Food Estab, Retail Non-Permanent Location (Event) L&I license filing marked inactive

    License 902177 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  72. License issue eventTHE SHAKE SEAFOOD: Food Estab, Retail Non-Permanent Location (Event) L&I license filing initially issued

    License 902177 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  73. License terminal eventFAMILY DOLLAR STORES OF PA INC (TAX AND LICENSE DEPT.): Food Establishment, Retail Perm Location (Large) business license marked inactive

    License 634543 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  74. CertificationSprinkler Certification

    Certification BC-2023-010160 · Deficient

  75. InvestigationL&I investigation

    Case CF-2022-019951 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  76. License issue eventTHE SHAKE SEAFOOD: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 892203 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  77. InvestigationL&I investigation

    Case CF-2022-019951 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  78. ViolationINSPECTION, TESTING & MAINTENANCE

    Case CF-2022-019951 · Violation VI-2022-016354 · Code F-901.6 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  79. PermitNew Construction

    Permit FP-2022-000425 · Completed

    EZ STANDARD KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. INSTALL (1) ONE ANSUL R-102 WET CHEMICAL COMMERCIAL KITCHEN FIRE SUPPRESSION SYSTEM FOR PROTECTION OF KITCHEN EXHAUST HOOD - SEE MECHANICAL PERMIT MP-2021-000721 FOR KITCHEN HOOD. (CP-2021-007108)

  80. CertificationFire Alarm Certification

    Certification BC-2022-001928 · Certified

    Expires 2022-12-22

  81. CertificationSprinkler Certification

    Certification BC-2022-002862 · Certified

    Expires 2022-12-14

  82. CertificationSprinkler Certification

    Certification BC-2022-002863 · Deficient

  83. PermitAddition and/or Alterations

    Permit MP-2021-007380 · Expired

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  84. PermitSign

    Permit GP-2021-010947 · Expired

    FOR THE INSTALLATION OF SIGNS PER APPROVED PLANS.

  85. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2021-006363 · Issued

    FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED WALL SIGN. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLAN. NO CHANGE TO HEIGHT OR AREA OF STRUCTURE.

  86. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2021-012250 · Issued

    FOR THE REMOVAL OF TWO (2) STATICALLY ILLUMINATED WALL SIGNS, THE REMOVAL OF TWO (2) NON-ILLUMINATED WINDOW SIGNS, THE ERECTION OF TWO (2) STATICALLY ILLUMINATED WALL SIGNS, AND THE ERECTION OF TWO (2) NON-ILLUMINATED WINDOW SIGNS. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS.

  87. PermitNew Construction

    Permit EP-2021-006826 · Completed

    Install 400 amp electrical service as per 2017 NEC.

  88. InvestigationL&I investigation

    Case CF-2020-086552 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  89. PermitAddition and/or Alteration

    Permit EP-2021-006834 · Completed

    Replacement of the existing Fire Alarm System as per nfpa 72, Tthe existing system is obsolete. The existing wiring will be reused and the existing initiating devices will be removed and replaced with new in existing locations. Existing Notification devices will remain. New power supplies will also be installed. All work in accordance with the 2017 nec & 2916 nfpa-72

  90. PermitAddition and/or Alteration

    Permit EP-2021-000641 · Completed

    THE 400 AMP SERVICE AND PANEL ARE EXISTING. INSTALL LIGHT FIXTURES, SWITCHES, OUTLETS PROVIDE WIRING FOR THE KITCHEN EQUIPMENT, SHUNT TRIP GAS VALVE & KITCHEN HOOD. AS PER 2017 NEC INSTALL NEW FIRE ALARM SYSTEM AS PER THE 2016 NFPA 72

  91. PermitAddition and/or Alterations

    Permit FP-2021-001604 · Completed

    Relocate (29) sprinkler heads to accommodate wall and ceiling layout as per NFPA 13 See CP-07108

  92. InvestigationL&I investigation

    Case CF-2020-086552 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  93. PermitAlterations

    Permit PP-2021-000223 · Completed

    INSTALL 2 FLOOR DRAIN, 1 MOP SINK, 1 ICE MACHINE, (1) 2-COMPARTMENT SINK, 5 LAVATORY, 6 TOILETS, 1 URINAL, (2) 3-COMPARTMENT SINKS, 2 HAND SINK, 2 GREASE TRAP, 1 DISH WASHER

  94. PermitAddition and/or Alterations

    Permit MP-2021-000721 · Completed

    For the installation of a Type I Commercial Kitchen Exhaust Hood within the kitchen of a Group A-2 restaurant tenant within Suite 106A, including all associated ductwork and exhaust/make-up air fans, as per plans; separate permit required for installation of kitchen hood fire suppression system; see CP-2020-007108 for building permit.

  95. PermitRough-In

    Permit PP-2021-001184 · Completed

    ROUGH IN ALL FIXTURES 2 FLOOR DRAIN, 1 MOP SINK, 1 ICE MACHINE, (1) 2-COMPARTMENT SINK, 5 LAVATORY, 6 TOILETS, 1 URINAL, (2) 3-COMPARTMENT SINKS, 2 HAND SINK, 2 GREASE TRAP, 1 DISH WASHER

  96. PermitAddition and/or Alterations

    Permit MP-2021-000437 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For Mechanical Work to include the installation as per attached standards. Deviations from these standards require submission of construction and site plans. EXISTING SYSTEM, NEW DUCT WALL ACCORDING TO PLANS,

  97. PermitChange of Use

    Permit ZP-2021-001003 · Issued

    Eating and Drinking Establishments - Sit-Down Restaurant

  98. PermitAddition and/or Alteration

    Permit CP-2020-007108 · Completed

    FOR LEVEL II INTERIOR ALTERATIONS (WITH NO CHANGE IN OCCUPANCY) PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.

  99. AppealZBA Permit Denial - Special Exception

    Appeal 39709 · In Process · Complete

    PERMIT FOR SIT DOWN RESTAURANT, AS PART OF AN EXISTING SHOPPING CENTER IN A DETACHED STRUCTURE AP 1030867

  100. InvestigationL&I investigation

    Case CF-2020-086552 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  101. ViolationMEANS OF EGRESS ILLUMINATION

    Case CF-2020-086552 · Violation VI-2020-052205 · Code FC-13-1006.1 · COMPLIED

    Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.

  102. ViolationEXIT SIGN ILLUMINATION

    Case CF-2020-086552 · Violation VI-2020-052206 · Code FC-13-1007.2 · COMPLIED

    Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.

  103. ViolationEGRESS READILY OPENABLE

    Case CF-2020-086552 · Violation VI-2020-052207 · Code FC-13-1003.4 · COMPLIED

    Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.

  104. ViolationFIRE DOORS CLOSE/LATCH

    Case CF-2020-086552 · Violation VI-2020-052208 · Code FC-13-703.2.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  105. License issue eventGBC Food Services LLC (Yummi Sushi): Food Preparing and Serving business license initially issued

    License 853040 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  106. InvestigationL&I investigation

    Case CF-2020-000399 · PASSED

    The cited inspection visit was marked passed.

  107. InvestigationL&I investigation

    Case CF-2020-018950 · PASSED

    The cited inspection visit was marked passed.

  108. ViolationUNSAFE STRUCTURE

    Case CF-2020-018950 · Violation VI-2020-006729 · Code PM15-108.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  109. ViolationSTEEL COMPONENTS

    Case CF-2020-018950 · Violation VI-2020-006730 · Code PM15-306.1(5) · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  110. ViolationEXTERIOR FLOORING

    Case CF-2020-018950 · Violation VI-2020-006731 · Code PM15-304.1(I) · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  111. InvestigationL&I investigation

    Case CF-2020-018950 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  112. InvestigationL&I investigation

    Case CF-2020-000399 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  113. ViolationEXTERIOR STRUCTURE STAIRS, DECKS, PORCHES

    Case CF-2020-000399 · Violation VI-2020-000203 · Code PM15-304.10 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  114. PermitElectrical

    Permit 1046456 · COMPLETED

    THE BUILDING TENANT SPACE IS USED AS AS PROFESSIONAL MEDICAL OFFICE--WORK INVOLVES THE INSTALLATION OF A NEW FIRE ALARM SYSTEM AS PER NFPA 72. (NC DISTRICT)

  115. PermitPlumbing

    Permit 1040716 · COMPLETED

    INSTALLATION OF ROUGH PLUMBING FOR MEDICAL SUITE--INCLUDES NEW WATER AND DRAIN LINES THROUGHOUT AND NEW FIXTURES (1) HWH, (4) TOILETS, (1) WATER COOLER, (13) LAV'S

  116. PermitElectrical

    Permit 1042863 · COMPLETED

    ELECTRIC FIT OUT, ROUGH AND FINISH OFFICE SPACE PER 2017 NEC LIGHTS, OUTLETS, RECEPTACLES, 2 BATH FANS (NORTH DIST)

  117. PermitSuppression

    Permit 1042621 · COMPLETED

    EXTENSION OF EXISTING NFPA 13 SPRINKLER SYSTEM TO ACCOMODATE NEW MEDICAL TENANT IN SPACE 108 AS PER APPROVED PLANS. NO WORK TO EXISTING FIRE MAIN AND RISER. ALL WORK TO BE PERFORMED BY PHILADELPHIA LICENSED FIRE SUPPRESSION CONTRACTOR.

  118. PermitZoning/use

    Permit 1028283 · COMPLETED

    INSTALL ONE (1) LED LIT ACCESSORY CHANNEL LETTER SIGN 4'-4 11/16"X22'-6 9/16"(98.99 SQ FT) ON FRON ELEVATION. INSTALL ONE (1) LED LIT ACCESSORY CHANNEL LETTER SIGN 3'-11 1/2"X20'4 1/8" (80.53 SQ FT) ON REAR ELEVATION. INSTALL DOOR VINYL ON FRONT ENTRY 16" X 19" (2 SQFT EACH). INSTALL DOOR VINYL ON REAR ENTRY 16'X19" (2 SQFT EACH).

  119. PermitMajor alteration

    Permit 1023541 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS TO INCLUDE A CHANGE OF OCCUPANCY FOR RENOVATIONS TO EXISTING FIRST FLOOR (SPACE #108) AS PER APPROVED PLANS** EXISTING BUILDING FULLY SPRINKLERED**IEBC 2018**SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  120. PermitUse

    Permit 1027540 · COMPLETED

    FOR A MEDICAL, DENTAL, HEALTH PRACTITIONER ( GROUP PRACTITIONER) AT SPACE# 108 AS PART OF EXISTING STRUCTURE. NO SIGN ON THIS APPLICATION

  121. InvestigationBP_BLDG

    Case 706368 · PASSED

    The cited inspection visit was marked passed.

  122. PermitPlumbing

    Permit 1011143 · COMPLETED

    REPLACE 2-WATER CLOSETS,2-LAVS AND 1-DRINKING FOUNTAIN FIXTURES IN KIND ONE FOR ONE WITH NO ALTERATIONS TO PIPING.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  123. ViolationPERMP- ALTER/REPAIR/REPL PLUMB

    Case 706368 · Violation 5179245 · Code A-301.1/55 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  124. ViolationPERMB- INSTALL HVAC SYS

    Case 706368 · Violation 5179243 · Code A-301.1/46 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  125. ViolationPERME- ALTER ELEC INSTALLATION

    Case 706368 · Violation 5179244 · Code A-301.1/53 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  126. InvestigationBP_BLDG

    Case 706368 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  127. PermitElectrical

    Permit 991784 · COMPLETED

    INSTALL NEW LIGHTING OUTLETS SWITCHES DATA RACEWAY AS PER 2008 NEC CODE (NORTH DIST)

  128. PermitSuppression

    Permit 993851 · COMPLETED

    RELOCATE 20 EXISTING SPRINKLER HEADS TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO 13 AND ALL LOCAL CODES.

  129. PermitZoning/use

    Permit 985120 · COMPLETED

    INSTALL (2) SETS OF ILLUMINATED CHANNEL LETTERS ON FRONT AND REAR BUILDING FACADE. SIGN A-1:2'-10" X 13'-7 1/4" = 38.54 SF (2ND STREET). SIGN A-2: 2'-6" X12' = 30 SF (PARKING LOT) FOR THE ERECTION OF TWO INTERNALLY ILLUMINATED ACCESSORY CHANNEL LETTER (FLAT WALL) SIGNS ON AN EXISTING STRUCTURE (SIZE AND LOCATION AS SHOWN ON THE PLAN)ACCESSORY TO A PREVIOUSLY APPROVED FITNESS CENTRE (PERSONAL SERVICES) IN SPACE # 104 OF AN EXISTING STRUCTURE WITH OTHER EXISTING USES AS PREVIOUSLY APPROVED..

  130. PermitSign

    Permit 985121 · COMPLETED

    INSTALL (2) SETS OF ILLUMINATED CHANNEL LETTERS ON FRONT AND REAR BUILDING FACADE. SIGN A-1:2'-10" X 13'-7 1/4" = 38.54 SF (2ND STREET). SIGN A-2: 2'-6" X12' = 30 SF (PARKING LOT)DETAILS AS SHOWN ON THE PLAN.

  131. PermitMajor alteration

    Permit 949829 · COMPLETED

    FOR LEVEL II INTERIOR ALTERATIONS FOR TENANT FIT-OUT IN AN EXISTING BUILDING. SIZE AND LOCATION AS PER APPROVED PLANS. SEPERATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING.

  132. PermitUse

    Permit 949776 · COMPLETED

    FOR USE AS PERSONEL SERVICES IN SPACE # 104 OOF AN EXISTING STRUCTURE WITH OTHER PREVIOUSLY APPROVED USES (NO SIGNS ON THIS PERMIT)

  133. PermitElectrical

    Permit 905022 · COMPLETED

    DISCONNECT AND REMOVE WIRING FOR DEMOLITION OF CABINET BY OTHERS,INSTALL 2-RECEPTS IN NEW WALL AND 1-EXIT FIXTURE ON AN EXISTING SERVICE AS PER 2008 NEC (CC DISTRICT)

  134. PermitMajor alteration

    Permit 894397 · COMPLETED

    INTERIOR RENVOATION OF EXISTING SPACE TO EXPAND WHOLESALE SPACE. SEPARATE PERMIT REQ'D FOR ANY ELECTRICAL & FIRE SUPPRESSION WORK.

  135. PermitMechanical

    Permit 896027 · COMPLETED

    INSTALL 2 HVAC UNITS WITH DUCTWORK. NO PENETRATION OF FIREWALLS. (COMMERCIAL)

  136. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 579102 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  137. InvestigationCI INSP

    Case 453350 · PASSED

    The cited inspection visit was marked passed.

  138. PermitMajor alteration

    Permit 862091 · COMPLETED

    PARKING GARAGE REPAIRS AS PER PLAN.

  139. PermitUse

    Permit 852332 · COMPLETED

    FOR A FITNESS CENTER IN SPACE # 108 AS PART OF AN EXITING SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APRPOVED. NO SIGN ON THIS PERMIT.

  140. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 579102 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  141. InvestigationCI INSP

    Case 579102 · CLOSED

    City marked the record closed; open the case for the closing reason.

  142. InvestigationCI INSP

    Case 579102 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  143. PermitMechanical

    Permit 758548 · COMPLETED

    INSTALLATION OF NEW 9000 BTU/H DUCTLESS A/C SYSTEM IN EXISTING SECOND FLOOR SUPERMARKET AS PER APPROVED PLANS.

  144. ViolationEXTERIOR STRUCT PROTECTIVE TRE

    Case 579102 · Violation 4485652 · Code PM15-304.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  145. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 579102 · Violation 4485650 · Code FC-13-912 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  146. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 579102 · Violation 4485651 · Code FC-13-915.1A · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  147. InvestigationCI INSP

    Case 579102 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  148. PermitPlumbing

    Permit 752971 · COMPLETED

    ALTERATIONS: INTERIOR PLUMBING;SECOND FLOOR GROCERY STORE; PHARMACY, FLORAL, & STARBUCKS AREA -THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  149. PermitElectrical

    Permit 753134 · COMPLETED

    RETAIL GROCERY STORE: RELOCATE REFRIGERATOR CASES AND ADD NEW REFIRG CASES.POWER AND HOOKUP OF DELI-PREP COOKING EQUIPMENT.3 OUTSIDE BEER SIGN.29 LIGHTS FOR RESTROOMS,LOUNGE AND OFFICE.RELOCATE PHARMACY POWER,DATA AND SECURITY EQUIPMENT. HOOKUP STARBUCKS FIXTURE PER 2008 NEC (SUPERMRKET)

  150. PermitSuppression

    Permit 748678 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS

  151. PermitMajor alteration

    Permit 745463 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO EXISTING SECOND FLOOR GROCERY STORE AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  152. InvestigationBC INSP (likely: building-code inspection)

    Case 554832 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  153. InvestigationBC INSP (likely: building-code inspection)

    Case 554880 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  154. InvestigationBC INSP (likely: building-code inspection)

    Case 555000 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  155. InvestigationBC INSP (likely: building-code inspection)

    Case 555012 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  156. InvestigationBC INSP (likely: building-code inspection)

    Case 555031 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  157. ViolationVENDOR ST NUISANCE AH

    Case 554832 · Violation 4080132 · Code 09-203.7/5 · ERROR

  158. ViolationVENDOR ST NUISANCE AH

    Case 554880 · Violation 4080283 · Code 09-203.7/5 · ERROR

  159. ViolationVENDOR ST NUISANCE AH

    Case 555000 · Violation 4081020 · Code 09-203.7/5 · ERROR

  160. ViolationVENDOR ST NUISANCE AH

    Case 555012 · Violation 4081100 · Code 09-203.7/5 · ERROR

  161. ViolationVENDOR ST NUISANCE AH

    Case 555031 · Violation 4081194 · Code 09-203.7/5 · ERROR

  162. InvestigationBC INSP (likely: building-code inspection)

    Case 554832 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  163. InvestigationBC INSP (likely: building-code inspection)

    Case 554880 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  164. InvestigationBC INSP (likely: building-code inspection)

    Case 555031 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  165. InvestigationBC INSP (likely: building-code inspection)

    Case 555012 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  166. InvestigationBC INSP (likely: building-code inspection)

    Case 555000 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  167. License terminal eventSUPER FRESH FOOD MARKET (SUSAN KIJOWSKI): Food Establishment, Retail Perm Location (Large) business license marked inactive

    License 542649 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  168. License terminal eventGRACE HEE KIM (FRESH KING SUSHI): Food Preparing and Serving business license marked inactive

    License 631301 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  169. PermitSuppression

    Permit 591762 · EXPIRED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  170. PermitMajor alteration

    Permit 586434 · EXPIRED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO INSTALL AN INTERIOR VESTIBULE IN RETAIL SPACE 7 AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY ME OR FIRE SUPPRESSION WORK**

  171. PermitSign

    Permit 554980 · COMPLETED

    2 FLAT WALL CHANNEL LETTER SIGNS

  172. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 416348 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  173. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 416348 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  174. PermitElectrical

    Permit 550024 · COMPLETED

    INSTALLATION OF 60AMP MCB 120/208V 3PHASE 4 WIRE PANEL BEING TIED INTO THE EXITING LANDLORD ELECTRICAL SERVICE.INSTALLATION OF LIGHTING AND POWER BRANCH CIRCUITS PER 2008 NEC & NFPA 72(BANK)

  175. PermitElectrical

    Permit 554930 · COMPLETED

    FURNISH & INSTALL 11-DUAL CAT 5E PLENUM RATED CABLES, & 2-CAT 6 PLENUM TATED CABLE TO D MARC 100' (COMM) TO COMPLY WITH ARTICLES 300.21, 300.22 & 800 OF THE 2008 NEC

  176. PermitZoning/use

    Permit 550169 · COMPLETED

    FOR THE ERECTION OF TWO FLATWALL CHANNEL LETTER SIGNS ACCESSORY TO A BANK SPACE 6B IN A STRUCTURE WITH PREVIOUSLY APPROVED USES. SIZE AND LOCATION AS SHOWN ON SUBMITTED PLAN.

  177. PermitSuppression

    Permit 552377 · COMPLETED

    RELOCATE SPRINKLERS

  178. PermitElectrical

    Permit 544674 · COMPLETED

    RETAIL FIT OUT TO INCLUDE SERVICE FEED FROM LL BUSS DUCT,BRANCH CIRCUIT WIRING AND DEVICES.FIRE ALARM INSTALL DEVICES TO EXISTING BUILDING SYSTEM PER 2008 NEC & NFPA 72(SHOPPING CENTER)*CERTIFICATION AND TESTING BY LL FIRE ALARM PROVIDER

  179. PermitElectrical

    Permit 544675 · COMPLETED

    RETAIL FIT OUT TO INCLUDE SERVICE FEED FROM LL BUSS DUCT,BRANCH CIRCUIT WIRING AND DEVICES.FIRE ALARM INSTALL DEVICES TO EXISTING BUILDING SYSTEM PER 2008 NEC & NFPA 72(SHOPPING CENTER)*CERTIFICATION AND TESTING BY LL FIRE ALARM PROVIDER

  180. PermitElectrical

    Permit 550989 · COMPLETED

    INSTALL BURGLAR ALARM PANEL, KEYPAD, (4)DOOR CONTACTS, (2)MOTION DETECTORS, (4)GLASS BREAK DETECTORS & SOUNDER, (6)CCTV CAMERAS.... IN ACCORDANCE WITH 2008 NEC

  181. License issue eventFAMILY DOLLAR STORES OF PA INC (TAX AND LICENSE DEPT.): Food Establishment, Retail Perm Location (Large) business license initially issued

    License 634543 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  182. PermitSuppression

    Permit 543809 · COMPLETED

    TIE INTO EXISTING WET PIPE SPRINKLER SYSTEM TO ADD AND RELOCATE SPRINKLERS TO ACCOMODATE TENANT FITOUT AS PER PLAN.

  183. PermitElectrical

    Permit 547313 · COMPLETED

    CONNECT 2 OUTDOOR WALL SIGNS TO EXISTING LINES, 120V, 20A... IN ACCORDANCE WITH 2008 NEC

  184. PermitMechanical

    Permit 534091 · COMPLETED

    MECHANICAL FIT-OUT FOR A NEW FINANCIAL SERVICES TENANT IN SPACE '6B' OF AN EXISTING BUILDING. WORK TO INCLUDE ALL DUCTWORK, REGISTERS, DIFFUSERS, FANS, EXHAUST AND APPLIANCES AS SHOWN ON APPROVED PLANS.

  185. PermitMajor alteration

    Permit 533112 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS TO FIT-OUT A TENANT SPACE FOR USE AS A FINANCIAL ESTABLISHMENT (BANK). BUILDING IS FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION SYSTEMS.

  186. License issue eventGRACE HEE KIM (FRESH KING SUSHI): Food Preparing and Serving business license initially issued

    License 631301 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  187. PermitMajor alteration

    Permit 528564 · COMPLETED

    TENANT FITOUT PER PLANS; INTERIOR ALTERATIONS INCLUDING NEW PARTITIONS TO CREATE ACCESSIBLE TOILET ROOMS, STORAGE, OFFICE AND PET WASHING AREAS (WITH ONE ACCESSIBLE WASHING STATION); NEW ACCESSIBLE CHECKOUT AREA; NEW FINISHES THROUGHOUT. SEPARATE PERMITS REQUIRED FOR ANY ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK. SEE PERMIT # 529475 FOR MECHANICAL WORK.

  188. PermitMechanical

    Permit 529475 · COMPLETED

    INSTALLATION OF TWO (2) AIR HANDLERS, COOLING COIL, ASSOCAITED DUCTWORK WITH GRILLES, REGISTERS AND DIFFUSERS, LOUVERS AT EXTERIOR WALL, EXHAUST FANS AND UNIT HEATER. SEPARATE PERMITS REQUIRED FOR ALL ELECTRICAL AND PLUMBING WORK. SEE PERMIT # 528564 FOR ALTERATIONS.

  189. PermitSign

    Permit 528582 · COMPLETED

    INSTALL A 18"X 198" FLAT WALL CHANNEL LETTER SIGN - EYE CARE CENTER

  190. PermitSign

    Permit 530425 · COMPLETED

    INSTALLATION OF (2) INTERNALLY ILLUMINATED RACEWAY MOUNTED FLAT WALL SIGNS.

  191. ViolationINSURANCE - POST CERT

    Case 504334 · Violation 3157722 · Code A-302.8/32 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  192. PermitUse

    Permit 532026 · COMPLETED

    USE FROM VACANT TO A BANK IN SPACE 6B

  193. PermitPlumbing

    Permit 532241 · COMPLETED

    ROUGH IN FOR 2 TOILETS,2 LAVS,1 ELECTRIC WATER COOLER,1 MOP SINK,3 FLOOR SINKS AND 3 FLOOR DRAINS (SHOPPING CENTER)

  194. PermitPlumbing

    Permit 532234 · COMPLETED

    ROUGH IN 1 TOILET,1 LAV SINK AND 1 KITCHEN SINK (BANK)

  195. PermitZoning/use

    Permit 525432 · COMPLETED

    INSTALLATION OF ONE INTERN ILLUM RACEWAY MOUNTED. CHANNEL LETTERS ON FRONT ELEVATION AND 1 SET OF 24" INTERN ILLUM RACEWAY MOUNTED LETTERS ON REAR ELEVATION ACCESSORY TO FOR THE RETAIL SALES OF PETS / PET SUPPLIES (WITH ACCESSORY ANIMAL SERVICES) IN SPACE 7

  196. PermitZoning/use

    Permit 525779 · COMPLETED

    INSTALL FLAT WALL SIGN ON SPACE # 5

  197. InvestigationCI INSP

    Case 416348 · CLOSED

    City marked the record closed; open the case for the closing reason.

  198. PermitSuppression

    Permit 522332 · COMPLETED

    RELOCATE 15 SPRINKLERS TO ACCOMODATE NEW CEILING LAYOUT

  199. PermitElectrical

    Permit 517243 · COMPLETED

    FITOUT SERVICE, LIGHTING, OUTLETS & BRANCH CKTS, F/A DEVICES ADDED TO EXISTING SYSTEM & RELOCATE EXIST CERT BY FA VENDOR AS PER NEC 2008 & NFPA 72 (COMM)

  200. InvestigationCI INSP

    Case 416348 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  201. ViolationANNUAL CERT FIRE ALARM

    Case 416348 · Violation 3316184 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  202. ViolationANNUAL CERT FIRE SUPP

    Case 416348 · Violation 3316185 · Code FC-915.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  203. InvestigationCI INSP

    Case 416348 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  204. PermitElectrical

    Permit 501922 · COMPLETED

    TENANT FIT-OUT - NEW 200AMP ELECTRICAL SERVICE, LUMINAIRES, OUTLETS AND BRANCH CIRCUITS AS PER 2008 NEC (CC DISTRICT) INSTALL NEW FIRE ALARM SYSTEM AND TIE INTO BUILDINGS SYSTEM AS PER NFPA72

  205. PermitPlumbing

    Permit 508694 · COMPLETED

    1 TOILET,1 LAV,2 HAND SINKS AND 1 KITCHEN SINK (HEALTH CARE FACILITY)

  206. PermitMechanical

    Permit 505928 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR TENANT FIT OUT AS PER APPROVED PLANS.

  207. PermitMajor alteration

    Permit 504334 · COMPLETED

    LEVEL II ALTERATIONS FOR A TENANT FIT-OUT OF SPACE 5 TO INCLUDE A CERTIFICATE OF OCCUPANCY AS PER APPROVED PLANS. **SEPARATE MEP PERMITS REQUIRED**

  208. PermitUse

    Permit 505926 · COMPLETED

    FOR USE AS GROUP MEDICAL, DENTAL AND HEALTH PRACTITIONER OFFICE IN SPACE 5 OF AN EXISTING SHOPPING CENTER WITH OTHER USES, PARKING AND SIGNAGE AS PREVIOUSLY APPROVED. NO SIGNS ON THIS APPLICATION.

  209. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 368601 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  210. PermitSuppression

    Permit 504757 · COMPLETED

    RELOCATE 18 SPRINKLER HEADS IN SPACE #1

  211. PermitSuppression

    Permit 503616 · COMPLETED

    RELOCATE 9 SPRINKLER HEADS ONLY IN SPACE #1.

  212. ViolationPERM - MUST POST

    Case 488948 · Violation 2975040 · Code A-302.8/30 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  213. PermitPlumbing

    Permit 497643 · COMPLETED

    ROUGH IN FOR 2 BATHROOMS 1 MOP SINK,2 TOILETS,1 KITCHEN SINK,2 LAV,2 FLOOR DRAINS (PHYSICAL THERAPY WITHIN SHOPPING CENTER)

  214. PermitMajor alteration

    Permit 488948 · COMPLETED

    FOR LEVEL II ALTERATIONS TO THE FIRST FLOOR OF AN EXISTING STRUCTURE. ALTERATION TO INCLUDE THE ERECTION OF PARITION WALLS, PROVIDE ACCESSIBILITY IMPROVEMENTS AND MILLWORK. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.

  215. PermitMechanical

    Permit 493981 · COMPLETED

    FOR LEVEL II ALTERATION TO HVAC SYSTEM, ALTERATION TO INCLUDE THE ERECTION OF REGISTERS, DIFFUSER, HVAC EQUIPMENT WITH ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ELECTRICAL AND PLUMBING WORK.

  216. PermitSign

    Permit 493025 · COMPLETED

    INSTALL ONE SET OF CHANNEL LETTERS ON RACEWAY TO WALL FRONT.INSTALL ONE SET OF CHANNEL LETTERS ON RACEWAY UNDER GARAGE AREA PER SUBMITTED PLAN.

  217. PermitZoning/use

    Permit 489375 · COMPLETED

    INSTALLATION OF (1) SET OF ILLUM CHANNEL LETTERS TO WALL 3'X26'7" AND INSTALL (1) SET OF ILLUM LETTERS TO GARAGE WALL 2'X17" FOR PHYSICAL THERATPY BUILDING ON SPACE # 1

  218. PermitUse

    Permit 490343 · COMPLETED

    ATI PHYSICAL THERAPHY FACILITY

  219. InvestigationBP_BLDG

    Case 368601 · CLOSED

    City marked the record closed; open the case for the closing reason.

  220. InvestigationBP_BLDG

    Case 368601 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  221. PermitElectrical

    Permit 453788 · COMPLETED

    WIRE ELECTRICAL "T MOBILE" SIGN TO PANEL INSIDE STORE - AS PE 2008 NEC

  222. ViolationPERMZ- OR REMOVE ADVERTISING

    Case 368601 · Violation 2998955 · Code A-301.1/66 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  223. ViolationPERMB- FLAT WALL SIGN

    Case 368601 · Violation 2998954 · Code A-301.1/21 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  224. ViolationPENALTY- NO BLDG PERM INFO

    Case 368601 · Violation 2998956 · Code A-901.13/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  225. InvestigationBP_BLDG

    Case 368601 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  226. PermitElectrical

    Permit 445520 · COMPLETED

    INSTALL NEW WIRING FOR RETAIL SPACE, INSTALL NEW TRANSFORMER, 200A PANEL, CKTS FOR LIGHTS AND OUTLETS. ALL WORK DONE IN ACCORDANCE WITH 2008 NEC(CC DIST)(COMMERCIAL)

  227. PermitMechanical

    Permit 446429 · COMPLETED

    INSTALLATION OF HVAC SYSTEM, NEW AIR HANDLING UNITS, ELECTRIC HEATERS, DUCTWORK, DIFFUSERS, FANS & ACCESSORY MECHANICALS AND PIPING, CONNECT TO EXISTING ADJACENT SYSTEM AS PER PLANS AND SPECIFICATIONS.

  228. PermitPlumbing

    Permit 446446 · COMPLETED

    INSTALL NEW VENT LINE & WATER LINES TO SERVE 1-KITCHEN SINK, 1-TOILET, 1-SINK & 1-MOP SINK, DRAIN LINES EXISTING (STORE)

  229. PermitSuppression

    Permit 446230 · COMPLETED

    RELOCATE 10 EXISTING SPRINKLER HEADS(COMMERCIAL)

  230. PermitMajor alteration

    Permit 442382 · COMPLETED

    TENANT FITOUT FOR ANIMAL SERVICES/DOG TRAINING FACILITY AS PER PLANS. CERTIFICATE OF OCCUPANCY REQUIRED.

  231. PermitUse

    Permit 442338 · COMPLETED

    USE TO ANIMAL SERVICES AND RETAIL SALES OF PET RELATED PRODUCTS

  232. PermitSign

    Permit 438817 · COMPLETED

    INSTALLING 2 FLATWALL CHANNELL LETTER SIGNS AND REPLACEMENT OF 1 LETTER TO AN EXISTING SIGN. AS PER ATTACHED DRAWINGS AND PLANS.

  233. PermitZoning/use

    Permit 436307 · COMPLETED

    INSTALL 2 ILLUM WALL SIGNS. REPLACE THE LETTER "T" ON AN EXISTING WALL SIGN AS PER PLANS

  234. PermitMechanical

    Permit 390411 · COMPLETED

    INSTALL 2 AIR HANDLERS, GRILLES, REGISTERS,DIFFUSERS AND DUCTWORK AS PER PLAN.

  235. License issue eventFAMILY DOLLAR STORES OF PA, INC: Dumpster License - Private Property L&I license filing initially issued

    License 562437 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  236. PermitElectrical

    Permit 388092 · COMPLETED

    TENANT FITOUT TO INCLUDE ELE SERVICE, HVAC LINES, LT, SW, RECEPTS, REFRIGERATION POWER, SIGN LINES, EXT/EMER LT, PHONE CONDUIT STUBS AS PER 2008 NEC. RELOCATE EXISTING FA AS PER NFPA-72.(COMMERCIAL RETAIL)(CC DIST)

  237. PermitZoning/use

    Permit 389856 · COMPLETED

    USE TO VARIETY STORE. INSTALL 2 SETS ILLUM LETTERS ON RACEWAYS.

  238. PermitSign

    Permit 390216 · COMPLETED

    INSTALL TWO SETS OF ILLUM LETTERS ON RACEWAYS FOR RETAIL VARIETY STORE.

  239. PermitSuppression

    Permit 386207 · COMPLETED

    RELOCATE 30 EXISTING SPRINKLER HEADS(COMMERCIAL)

  240. InvestigationCI INSP

    Case 296965 · PASSED

    The cited inspection visit was marked passed.

  241. PermitMajor alteration

    Permit 371901 · COMPLETED

    TENANT FIT-OUT FOR RETAIL VARIETY STORE AND CERTIFICATE OF OCCUPANCY.

  242. PermitElectrical

    Permit 375848 · COMPLETED

    INSTALLATION OF A LOW VOLTAGE BURG ALARM SYSTEM AND CAMERA'S.

  243. PermitElectrical

    Permit 374892 · COMPLETED

    INSTALL 4 NEW NOTIFICATION STATIONS, RELOCATE 4 NOTIFICATION STATIONS, RELOCATE 2 PULL STATIONS AS PER NFPA 72 (RETAIL STORE IN SHOPPING CENTER)

  244. PermitElectrical

    Permit 373400 · COMPLETED

    FURNISH AND INSTALL (24)QUAD CATEGORY 5E PLENUM OUTLETS/CABLES. LONGEST RUN- 80FT. .... IN ACCORDANCE WITH 2008 NEC

  245. PermitUse

    Permit 371900 · COMPLETED

    ASC FOR THE VERIETY STORE

  246. PermitPlumbing

    Permit 371243 · COMPLETED

    INSTALL WATER AND SANITARY TO EXISTING LINES IN SPAVE ITH 2 WATER CLOSETS, 2 LAVS, 1 DRINKING FOUNTAIN, 1 MOP RECEPT, AND I UTILITY SINK (FRONT AND 1ST FLOOR(T-MOBILE))(COMMERCIAL-RETAIL)

  247. PermitMechanical

    Permit 325032 · COMPLETED

    HVAC, DUCTWORK. SEPERATE PERMIT FOR ALTS., SEE 324740 FOR PLANS

  248. PermitSuppression

    Permit 370507 · COMPLETED

    RELOCATE 20 EXISTING SPRINKLERS TO NEW CEILING FOR COMMERCIAL SPACE.

  249. PermitAdministrative

    Permit 365801 · COMPLETED

    AMEND PREVIOUSLY ISSUED PERMIT # 324740 TO REVISE FLOOR/ CEILING LAYOUT.SEPARATE ELECTRICAL PERMITS REQUIRED.

  250. PermitElectrical

    Permit 368322 · COMPLETED

    EXISTING SERVICE, AD 1 PANEL, LIGHTING,ECEPTACLES, TELEPHONE AND DATA WIRING, AS PER 2008 NEC,STORE

  251. InvestigationCI INSP

    Case 296965 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  252. ViolationFIRE LANE MARKED

    Case 296965 · Violation 2253747 · Code FC-503.3/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  253. ViolationFIRE LANE PROHIB CONT ACCESS

    Case 296965 · Violation 2253748 · Code FC-503.4/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  254. ViolationVIOL C&I MESSAGE

    Case 296965 · Violation 2253746 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  255. InvestigationCI INSP

    Case 296965 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  256. License issue eventSUPER FRESH FOOD MARKET (SUSAN KIJOWSKI): Food Establishment, Retail Perm Location (Large) business license initially issued

    License 542649 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  257. PermitElectrical

    Permit 352585 · COMPLETED

    1 75KVA TRANSFORMER, 1 200AMP PANEL, 233 LIGHT FIXTURES, 12 SWITCHES, 42 RECEPTACLES, DOOR BELL SYSTEM, 14 TELE DATA OUTLETS, RELOCATE 7 FIRE ALARM DEVICES, 2 NEW FIRE ALARMS STROBES, 7 SOUND SYSTEM SPEAKER, 7 HVAC EQUIP LINES AS PER 2008 NEC,NFPA-72

  258. PermitSuppression

    Permit 350585 · COMPLETED

    FOR THE RELOCATION OF (43) SPRINKLER HEADS AND THE INSTALLATION OF (4) ADDITIONAL SPRINKLER HEADS AS PER PLAN.

  259. PermitSign

    Permit 333567 · COMPLETED

    ERECTIONO F 2 FLATWALL SIGNS. INTERNALLY ILLUM

  260. PermitPlumbing

    Permit 343186 · COMPLETED

    INSTALLATION OF 2 WATER CLOSETS, 2 LAVYS, 1 MOP RECEPTOR AND 1 DRINKING FOUNTAIN WITH BRANCH PIPING TO EXISTING SANITARY LINE

  261. PermitMajor alteration

    Permit 331152 · COMPLETED

    TENANT FITOUT FOR LCB RETAIL STORE, C/O PART OF THIS APPLICATION

  262. PermitMechanical

    Permit 334390 · COMPLETED

    TENANT FITOUT FOR LCB RETAIL STORE, HVAC WORK IS PART OF THIS APPLICATION.

  263. PermitZoning/use

    Permit 329523 · COMPLETED

    RELOCATION OF LOT LINES TO CREATE (2) LOTS FROM (1) AS VERTICAL AND HORIZONTAL SUBDIVISION. RECONFIGURE/CREATION OF 4 COMMERCIAL/RETAIL SPACES FROM 3 EXISTING SPACES WITH USES AS FOLLOWS; FLOOR 1: SPACES V & W USE PERMITS REQUIRED. LOT1A SALE OF LIQUOR AND ALCOHOL (PA STATE STORE) FLOOR 2 TO BE SUPERMARKET, AS PREVIOUSLY APPROVED.

  264. PermitZoning/use

    Permit 323747 · COMPLETED

    INSTALL (2) ILLUMINATED FLATWALL SIGNS FOR RETAIL PHONE STORE.

  265. PermitMajor alteration

    Permit 324740 · COMPLETED

    REQUEST BLDG PERMIT FOR INTERIOR ALTERATIONS FOR THE RETAIL SALE OF CELL PHONES AND ACCESSORIES. SEPERATE PERMIT FOR MECHANICAL.

  266. PermitZoning

    Permit 314476 · COMPLETED

    RELOCATION OF LOT LINES TO CREATE (2) LOTS FROM (1) AS VERTICAL AND HORIZONTAL SUBDIVISION. RECONFIGURE/CREATION OF 4 COMMERCIAL/RETAIL SPACES FROM 3 EXISTING SPACES WITH USES AS FOLLOWS; FLOOR 1: SPACES V & W USE PERMITS REQUIRED. LOT1A SALE OF LIQUOR AND ALCOHOL (PA STATE STORE) FLOOR 2 TO BE SUPERMARKET, AS PREVIOUSLY APPROVED.

  267. PermitUse

    Permit 324667 · COMPLETED

    USE TO RETIAL FOR CELL PHONES AND ACCESSORIES IN TENANT SPACE #4 WITHING EXISTING SHOPPING CENTER.

  268. PermitElectrical

    Permit 316369 · COMPLETED

    INSTALL 60 CAT5E DATA CABLES,INSTALL 25 CAT5E VOICE CABLE ALL CABLE WILL BE INSTALLED IN J HOOKS,ALL SLEEVES WILL BE FIRE STOP AS PER 2008 NEC

  269. AppealZoning board appeal

    Appeal 14222 · CLOSED · Granted

    Related permit 314476 · PERMIT FOR THE RELOCATION OF LOT LINES TO CREATE TWO (2) LOTS FROM ONE (1) LOT ( FOR UNITY OF USE OF 2 LOTS AS 1 LOT FOR THE PURPOSES OF ZONING AND WHERE THE UNITY OF USE WILL BE BOUNDED BY EASEMENTS, AGREEMENTS AND COVENANTS CLEARLY LIMITI

  270. InvestigationBP_BLDG

    Case 260282 · PASSED

    The cited inspection visit was marked passed.

  271. InvestigationBP_BLDG

    Case 260282 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  272. PermitUse

    Permit 317583 · COMPLETED

    SPACE V- RETAIL SALES OF LIQUOR AND ALCOHOLIC BEVERAGES IN A SHOPPING CENTER

  273. InvestigationBP_BLDG

    Case 245250 · PASSED

    The cited inspection visit was marked passed.

  274. PermitMechanical

    Permit 315386 · COMPLETED

    REFRIGERATION MECHANICAL HOUSE AND FIXTURE AND INTERCONNECTING PIPING.

  275. PermitAdministrative

    Permit 308809 · COMPLETED

    REVISING PERMIT#285479 TO RELOCATE PHARMACY ONLY. NO CHANGE IN EGRESS OR EGRESS DISTANCE

  276. PermitAdministrative

    Permit 299226 · COMPLETED

    REVISE PERMIT #241428 TO ALLOW PARKING GARAGE TO BE CONSIDERED OPEN, AS PERMITTED BY VARIANCE

  277. ViolationPERMB- FLAT WALL SIGN

    Case 260282 · Violation 1944714 · Code A-301.1/21 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  278. InvestigationBP_BLDG

    Case 260282 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  279. AppealBuilding standards appeal

    Appeal 13494 · OPEN · APPROVED

    Related permit 299226 · ON 9/29/10,THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #299226.

  280. PermitSuppression

    Permit 300355 · COMPLETED

    INSTALL KITCHEN HOOD FIRE SUPPRESSION SYSTEM. ( ANSUL R-102, 6 GALLON )

  281. PermitMechanical

    Permit 299235 · COMPLETED

    INSTALL (7) SPLIT SYSTEM & OUTSIDE AIR DUCTWORK PER PLAN

  282. PermitMajor alteration

    Permit 285479 · COMPLETED

    TENANT FIT-OUT OF SUPERMARKET. FIT OUT TO INCLUDE NEW AISLES, FLOORS WALLS, EMPLOYEE LOUNGE MECH ROOMS REFRIGERATION ROOMS,FREEZER ROOMS,HVAC,INCLUDING ROOFTOP UNITS.ALL WORK BY LICENSED CONTRACTORS. SEP PERMITS FOR SPRINKLERS, AND SIGNS.

  283. ViolationPERMB- INSTALL HVAC SYS

    Case 245250 · Violation 1767342 · Code A-301.1/46 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  284. ViolationPERMB- ALTER REPAIR INT PART (Building permit required for interior alteration or repair)

    Case 245250 · Violation 1767341 · Code A-301.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  285. ViolationLISTED CONDIT DOES NOT COMPLY

    Case 245250 · Violation 1767340 · Code A-501.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  286. InvestigationBP_BLDG

    Case 245250 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  287. PermitElectrical

    Permit 276104 · COMPLETED

    INTERIOR FRONT OF NEW SUPERMARKET SPACE INCLUDING NEW PANELS, LIGHTING, POWER WIRING TO HVAC AND REFRIGERATION SYSTEMS, GENERAL PURPOSE OUTLETS AND NEW FIRE ALARM SYSTEM AS PER 2008 NEC NFPA 72 (CC DISTRICT)

  288. PermitSuppression

    Permit 275249 · COMPLETED

    INSTALL NEW SPRINKLER SYSTEM AS PER PLAN

  289. PermitElectrical

    Permit 274348 · COMPLETED

    FIRE ALARM AS PER NFPA-72, POWER AND LIGHT AS PER 2008 NEC (CC DIST)

  290. PermitPlumbing

    Permit 262772 · COMPLETED

    NEW SUPERMARKET WITH PARKING GARAGE AND RETAIL SPACES.

  291. PermitNew construction

    Permit 241428 · COMPLETED

    CONSTRUCTION OF A 2-STORY STRUCTURE FOR USE AS AN ENCLOSED PARKING GARAGE, SUPERMARKET AND 13 VACANT COMMERCIAL SPACES. USE REGISTRATION PERMIT FOR VACANT TENANT SPACES REQUIRED PRIOR TO OCCUPANCY.

  292. InvestigationBP_BLDG

    Case 204206 · PASSED

    The cited inspection visit was marked passed.

  293. PermitAdministrative

    Permit 232317 · COMPLETED

    REVISE PERMIT #225598 TO SHOW CORRECT ADDRESS 180 W. GIRARD AVE, LOT 1 BRT 88-2932475

  294. InvestigationBP_BLDG

    Case 204206 · PASSED

    The cited inspection visit was marked passed.

  295. PermitZoning/use

    Permit 225609 · COMPLETED

    CREATING THREE (3) LOTS FROM ONE (1) LOT TO BE USED AS LOT #1 WILL BE ERECTION OF A TWO STORY BUILDING TO BE USED FOR RETAIL/SUPERMARKET WITH ACCESSORY PARKING GARAGE FOR (311 SPACES) AND ACC SIGNAGE, LOT #2 WILL HAVE FOUR (4) BLDGS. BLDG 1 WILL HAVE (26) STORIES TO BE USED AS RESIDENTAIL (285 UNITS) AND 1ST FLOOR FOR RETAIL BLDG 2 (16) STORIES (229) DWELLING UNITS AND A PARKING GARAGE WITH (216) SPACES BLDG 3 (4) STORIES (53) DWELLING UNITS BLDG 4 (5) STORIES WITH (33) DWELLING UNITS 1ST FLOOR RETAIL LOT #3 PREVIOULSY APPROVED STRUCTURE PERMIT NO. 706562 USES AS PERMITTED IN ASC.

  296. PermitZoning/use

    Permit 225610 · COMPLETED

    ACCESSORY SIGNS

  297. ViolationPERMB- CONST FOUNDATION

    Case 204206 · Violation 1409411 · Code A-301.1/15 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  298. ViolationPENALTY- NO BLDG PERM INFO

    Case 204206 · Violation 1409412 · Code A-901.13/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  299. ViolationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)

    Case 204206 · Violation 1409413 · Code A-504.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  300. InvestigationBP_BLDG

    Case 204206 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  301. PermitZoning

    Permit 196557 · COMPLETED

    RELOCATION OF LOT LINES

  302. ViolationCLIP VIOLATION NOTICE

    Case 174052 · Violation 1059574 · Code CP-01 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  303. ViolationVACANT LOT KEEP CLEAN GET LIC

    Case 174052 · Violation 1059575 · Code PM-306.0/91 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

Where this comes from

Methodology & freshness

This report was assembled Jul 26, 2026, 1:07 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)