House report

1800 Pine St

2 bd2 ba3,300 sqftRM1built 1900

Property at a glanceHouse

Individual, other or unknown mailing address

2026 assessment
$1.5M OPA value, not a listing price
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

Published City assessments for this house against its block and ZIP. Dated City filings are marked on the same line. Select one to read it. Assessments are tax-roll values, not sale prices or appraisals.

$0$1.0M$2.0MZIP 19103 (Rittenhouse · Logan Square) median$1.1M201420172020202320262027
Property assessmentBlock median & rangeZIP 19103 (Rittenhouse · Logan Square) medianAssessmentPermit

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Every dated record9 events · exact dates, newest first
  1. PermitAdministrative
  2. PermitElectrical
  3. PermitPlumbing
  4. PermitMechanical
  5. PermitSuppression
  6. PermitZoning/use
  7. PermitMajor alteration
  8. PermitDemolition
  9. PermitDemolition

Informational only. Not investment advice or a consumer report (FCRA).

Verify the public record

$20,706/year estimated property tax

2026 taxable assessment $1,479,200 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,119,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 888089542
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Where the record looks off

Conflicts in City paperwork. Flags on the data, not the property.

"Built 1900" is usually a placeholder

Philadelphia records use 1900 as a stand-in when the real construction year was never documented. Treat the age as unknown, not as 120+ years.

The property, on paper

OPA physical field record.

Bedrooms
2
Bathrooms
2
Interior
3,300 sqft livable area
Heat
Forced hot air city code A
Central air
Yes
Exterior condition
Average city code 4
Interior condition
Above average city code 3
Quality grade
C+ assessor's grade
Zoning
RM1 city zoning code

OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.

Block context

1800 block of Pine St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1800 Pine St  ·  1800 Pine St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 23, 2026.

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 9 dated rows
  1. PermitAdministrative

    Permit 706847 · COMPLETED

    FOR A TEMPORARAY CERTIFICATE OF OCCUPANCY UNIT #103

  2. PermitElectrical

    Permit 645713 · COMPLETED

    RELOCATE WIRING FOR STRUCTURAL REPAIRS, REWIRE AND INSTALL NEW WIRING FOR ALL LIGHTING, POWER OUTLETS AND APPLIANCE CIRCUITS FOR NEW LAYOUT OF ALL LIVING AREAS THROUGHOUT CONDO AND INCLUDING EXTERIOR AREAS PER 2008 NEC (CONDO)CC DISTRICT

  3. PermitPlumbing

    Permit 647900 · COMPLETED

    INSTALL 3 WATER CLOSETS, 4 BASINS, 2 SHOWERS, 1 KITCHEN, 1 DISHWASHER, AND 1 WASHING MACHINE (REPLACE TO EXISTING WITH SOME MODIFICATIONS) ALL WORK TO COMPLY WITH THE 2004 PPC

  4. PermitMechanical

    Permit 639769 · COMPLETED

    INSTALLATION OF NEW DUCTWORK THROUGHOUT THE THIRD FLOOR; REMOVAL OF EXISTING HVAC EQUIPMENT SERVING 4TH FLOOR AND INSTALLATION OF 2-TON SYSTEM (AIR HANDLER WITH HOT WATER COIL AND OUTDOOR CONDENSING UNIT). NEW EXTERIOR UNIT TO BE REPLACED AT SAME LOCATION AS EXISTING; HISTORICAL COMMISSION APPROVAL REQUIRED IF RELOCATED. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL WORK.

  5. PermitSuppression

    Permit 646089 · COMPLETED

    RELOCATE 10 SPRINKLER HEADS TO CONFORM TO NEW CEILING.**EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  6. PermitZoning/use

    Permit 625371 · COMPLETED

    ADDITION OF ROOF TOP DECK AT MAIN/ FRONT BLOCK RAILINGS TO BE SET BACK AS TO NOT BE VIEWED FROM STREET.

  7. PermitMajor alteration

    Permit 606137 · COMPLETED

    ALL WORK PER PLANS APPROVED BY PHILADELPHIA HISTORICAL COMMISSION - SEE REQUIRED PHC APPROVAL ITEMS. LIMITED INTERIOR AND EXTERIOR DEMOLITION AT THIRD AND FOURTH FLOOR LEVELS; INTERIOR ALTERATIONS INCLUDING NEW PARTITIONS AND FINISHES THROUGHOUT DWELLING UNIT PER PLANS. NEW ROOF DECKS AT FOURTH FLOOR REAR AND UPPER ROOF WITH INTERCONNECTING STAIR. INSTALLATION OF REPLACEMENT CHANNEL FRAMING AT EXTERIOR BALCONY, SISTERING OF ROOF JOISTS AND INSTALLATION OF NEW WIDE FLANGE STEEL BEAMS PER ENGINEER'S DETAILS. ALL SPECIAL INSPECTION REPORTS TO BE FURNISHED TO FIELD INSPECTOR. SEPARATE PERMITS REQUIRED FOR ALL FS/M/E/P WORK.

  8. PermitDemolition

    Permit 621990 · COMPLETED

    INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILINGS ONLY AS PER EZ STANDARD. NO OTHER WORK ALLOWED UNDER THIS PERMIT. NO STRUCTURAL CHANGES. MUST MAINTAIN ALL CODE REQUIRED FIRE RATING ON WALL AND FLOOR/CEILING ASSEMBLIES. THREE SETS OF PLANS DRAWN TO PROFESSIONAL QUALITY ARE TO BE SUBMITTED FOR REVIEW AND APPROVAL BY THE DEPARTMENT BEFORE WORK ON RENOVATION STARTS. CONTACT STREETS DEPARTMENT FOR DUMPSTER PERMIT AND FOOTWAY CLOSURE PERMITS.

  9. PermitDemolition

    Permit 579793 · EXPIRED

    REMOVE DOORS, TRIM AND DRYWALL, REMOVE A PORTION OF DRYWALL SO WE CAB ASSES THE CURRENT STRUCTURE.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 11:00 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)