Multi-family report

1943-51 N 9th St

6,679 sqftRM1built 2018

Property at a glanceApartment building

Entity-held

2026 assessment
$88K OPA value, not a listing price
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

Published City assessments for this building against its block and ZIP. Dated City filings are marked on the same line. Select one to read it. Assessments are tax-roll values, not sale prices or appraisals.

$0$250K$500KZIP 19122 (Olde Kensington · North Philadelphia) median$88K2015201720192021202320252027
Property assessmentBlock median & rangeZIP 19122 (Olde Kensington · North Philadelphia) medianAssessmentAppealPermit

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record32 events · exact dates, newest first
  1. PermitMechanical
  2. PermitMechanical
  3. PermitMechanical
  4. PermitMechanical
  5. PermitPlumbing
  6. PermitElectrical
  7. PermitElectrical
  8. PermitElectrical
  9. PermitElectrical
  10. PermitPlumbing
  11. PermitPlumbing
  12. PermitPlumbing
  13. PermitPlumbing
  14. PermitSuppression
  15. PermitSuppression
  16. PermitSuppression
  17. PermitSuppression
  18. PermitNew construction
  19. PermitNew construction
  20. PermitNew construction
  21. PermitNew construction
  22. PermitZoning admin review
  23. PermitZoning/use
  24. PermitZoning admin review
  25. PermitZoning admin review
  26. PermitZoning admin review
  27. PermitZoning admin review
  28. PermitZoning
  29. PermitZoning
  30. PermitZoning
  31. PermitZoning
  32. AppealZoning board appeal

Flags: 1 zoning/board appeal on record. Informational only. Not investment advice or a consumer report (FCRA).

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $87,600. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 886780602
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

The property, on paper

OPA physical field record.

Interior
6,679 sqft livable area
Lot
3,157 sqft
Exterior condition
Newer construction city code 1
Newer construction
Interior condition
New / rehabbed city code 2
New / rehabbed
Quality grade
A- assessor's grade
Zoning
RM1 city zoning code
Zoning appeals
1 CLOSED · Granted · 2016

OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.

Recorded owner

Who's behind it

Philadelphia Housing Auth · corporate / LLC owner

• Owns 4773 properties across Philadelphia under this name, assessed at $1.4B combined
• Tax bills mail to 2013 Ridge Ave, Philadelphia PA, 19121

Block context

1900 block of N 9th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1941 N 9th St  ·  1939 N 9th St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 32 dated rows
  1. PermitMechanical

    Permit 872998 · COMPLETED

    COMPLETE NEW HVAC SYTEM WITH 3T HP OUTDOOR UNIT ON GROUND NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  2. PermitMechanical

    Permit 842258 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  3. PermitMechanical

    Permit 839376 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES-INSTALL ONE HVAC SYSTEM; HEATING AND COOLING AND DUCT WORK IN A SINGLE FAMILY DWELLING. FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  4. PermitMechanical

    Permit 839373 · COMPLETED

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES-INSTALL ONE HVAC SYSTEM; HEATING AND COOLING AND DUCT WORK IN A SINGLE FAMILY DWELLING. FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  5. PermitPlumbing

    Permit 829073 · COMPLETED

    ROUGH IN AND SET FIXTURES 1 WASHER BOX,1 KITCHEN,2 WC,2 LAVS,2 TUBS,1 FLOOR DRAIN PVC PIPE AND PEX WATER PIPE (SFD)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  6. PermitElectrical

    Permit 822242 · COMPLETED

    INSTALL 200AMP SERVICE COMPLETE GROUNDING ALL MEW WIRING SWITCHES LIGHTS RECEPTACLES 110V SMOKE DETECTOR/CO2 DETECTORS CATV AND TEL WIRING THROUGHOUT HOME AS PER 2008 NEC

  7. PermitElectrical

    Permit 821779 · COMPLETED

    INSTALL 200AMP SERVICE COMPLETE GROUNDING ALL NEW WIRING OF BUILDING WITH SWITCHES, LIGHTS, RECEPTACLES, 110V SMOKE DETECTORS/CO2 DETECTORS, CATV AND TEL WIRING THROUGHOUT THE HOME AS PER 2008 NEC (EAST DISTRICT)

  8. PermitElectrical

    Permit 814630 · COMPLETED

    INSTALL 200 AMP SERVICE, COMPLETE GROUNDING ALL NEW WIRING SWITCHES, LIGHTS, RECEPTACLES, 110V SMOKE DETECTORS/ CO2 DETECTORS, CATV&NTEL WIRING, THROUGH OUT THE HOME AS PER 2008 NEC

  9. PermitElectrical

    Permit 814602 · COMPLETED

    INSTALL 200 AMP SERVICE, COMPLETE GROUNDING ALL NEW WIRING SWITCHES, LIGHTS, RECEPTACLES, 110V SMOKE DETECTORS/ CO2 DETECTORS, CATV&NTEL WIRING, THROUGH OUT THE HOME AS PER 2008 NEC

  10. PermitPlumbing

    Permit 812132 · COMPLETED

    INSTALLATION TO INCLUDE 1-6" COMBINED LAT AND HOUSE TRAP WITH FAI 1-2" COMBINED WATER SERVICE WITH RFSS COMBO WATER METER 1-3" REAR YARD DRAIN AND RAIN WATER CONDUCTOR AS PER PHILADELPHIA 2004 PLUMBING CODE.

  11. PermitPlumbing

    Permit 812257 · COMPLETED

    PLUMBING CONSTRUCTION FOR A NEW SINGLE FAMILY DWELLING.

  12. PermitPlumbing

    Permit 812281 · COMPLETED

    PLUMBING CONSTRUCTION FOR A NEW SINGLE FAMILY DWELLING.

  13. PermitPlumbing

    Permit 812282 · COMPLETED

    PLUMBING CONSTRUCTION FOR A NEW SINGLE FAMILY DWELLING.

  14. PermitSuppression

    Permit 797418 · COMPLETED

    FOR THE INSTALLATION OF A RESIDENTIAL FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13-D THROUGHOUT A THREE (3) STORY STRUCTURE PER PLANS. THIS IS A MULTI-PURPOSE SYSTEM UTILIZING A COMBINED TWO INCH (2") DOMESTIC AND FIRE SERVICE LINE. SEPARATE PERMITS REQUIRED FOR ALL PLUMBING WORK.

  15. PermitSuppression

    Permit 800172 · COMPLETED

    INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D THROUGHOUT NEW THREE (3) STORY TOWNHOUSE TO INCLUDEW NEW 2-INCH COMBINED LINE AS PER APPROVED PLANS.

  16. PermitSuppression

    Permit 801770 · COMPLETED

    INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13D THROUGHOUT NEW THREE (3) STORY TOWNHOUSE TO INCLUDEW NEW 2-INCH COMBINED LINE AS PER APPROVED PLANS.

  17. PermitSuppression

    Permit 797414 · COMPLETED

    THE INSTALLATION OF A TWO (2) INCH COMBINED SERVICE LINE FOR A FIRE & DOMESTIC SUPPLY LINE. MULTIPURPOSE RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13D.

  18. PermitNew construction

    Permit 752722 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 749143 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  19. PermitNew construction

    Permit 747538 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 747531 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  20. PermitNew construction

    Permit 747537 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 747531 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  21. PermitNew construction

    Permit 738192 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 737569 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  22. PermitZoning admin review

    Permit 763022 · COMPLETED

    FOR THE ADMINISTRATIVE REVIEW OF A/P NO 738174 (CAL NO 28876) TO DECREASE THE HEIGHT OF THE BUILDING AND PARAPET. NO CHANGE TO FOOTPRINT OR GFA OF STRUCTURE. A/P NO 738174 WAS ISSUED FOR THE ERECTION OF AN ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (FOUR (4) DWELLING UNITS). NO SIGNS OR PARKING ON APPLICATION.

  23. PermitZoning/use

    Permit 738174 · COMPLETED

    FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. ON PARCEL D: FOR THE ERECTION OF AN ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (FOUR (4) DWELLING UNITS). NO SIGNS OR PARKING ON APPLICATION.

  24. PermitZoning admin review

    Permit 746319 · COMPLETED

    TO CORRECT PERMIT NO 738173 TO READ AS FOLLOWS: FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION.

  25. PermitZoning admin review

    Permit 746317 · COMPLETED

    TO CORRECT PERMIT NO 738171 TO READ AS FOLLOWS: FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION.

  26. PermitZoning admin review

    Permit 746316 · COMPLETED

    TO CORRECT PERMIT NO 717444 TO READ AS FOLLOWS: FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION.

  27. PermitZoning admin review

    Permit 746318 · COMPLETED

    TO CORRECT PERMIT NO 738172 TO READ AS FOLLOWS: FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION.

  28. PermitZoning

    Permit 738171 · COMPLETED

    FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. ON PARCEL D: FOR THE ERECTION OF AN ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (FOUR (4) DWELLING UNITS). NO SIGNS OR PARKING ON APPLICATION.

  29. PermitZoning

    Permit 738172 · COMPLETED

    FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. ON PARCEL D: FOR THE ERECTION OF AN ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (FOUR (4) DWELLING UNITS). NO SIGNS OR PARKING ON APPLICATION.

  30. PermitZoning

    Permit 738173 · COMPLETED

    FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. ON PARCEL D: FOR THE ERECTION OF AN ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (FOUR (4) DWELLING UNITS). NO SIGNS OR PARKING ON APPLICATION.

  31. PermitZoning

    Permit 717444 · COMPLETED

    FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. ON PARCEL D: FOR THE ERECTION OF AN ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (FOUR (4) DWELLING UNITS). NO SIGNS OR PARKING ON APPLICATION.

  32. AppealZoning board appeal

    Appeal 28876 · CLOSED · Granted

    Related permit 717444 · PERMIT FOR THE LOT ADJUSTMENT TO CREATE ONE LOT (PARCEL D) FROM FOUR (4) EXISTING DEEDED LOTS AND FOUR (4) OPA ACCOUNTS (1943 N 9TH STREET, 1945 N 9TH STREET, 1947-49 N 9TH STREET AND 1951 N 9TH STREET). SIZE AND LOCATION AS SHOWN ON PLANS

Where this comes from

Methodology & freshness

This report was assembled Jul 23, 2026, 4:01 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.