Apartment building report

2001-05 Frankford Ave

3 stories5,407 sqftCMX2built 1915

Property at a glanceApartment building

2001-03 Frankford LLC

2026 assessment
$1.0M OPA value, not a listing price
2027 published assessment
$1.3M Future roll, not the current tax bill
Neighborhood area
Fishtown · East Kensington Approximate · based on ZIP 19125
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $1,267,300. It is not yet the billed-year tax basis.

$0$1.0M$2.0M$1.3M200720112015201920232027
Property assessmentAssessmentL&I violationPermitInspection

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record74 events · exact dates, newest first
  1. PermitAddition and/or Alterations
  2. PermitNew construction, addition, GFA change
  3. PermitNew Construction or Additions
  4. PermitNew Construction
  5. PermitNew Construction
  6. PermitAddition and/or Alterations
  7. PermitAddition and/or Alteration
  8. InspectionL&I investigation
  9. InspectionL&I investigation
  10. InspectionL&I investigation
  11. InspectionL&I investigation
  12. PermitAddition and/or Alteration
  13. InspectionL&I investigation
  14. PermitRough-In
  15. PermitAmend for conversion
  16. PermitNew Construction or Additions
  17. L&I violationPENALTY- NO PLUMB PERM INFO
  18. L&I violationCOMPL CONCEAL- PLUMB PERM WORK
  19. InspectionBP_BLDG
  20. PermitNew Construction
  21. PermitNew Construction
  22. PermitPlumbing
  23. PermitAdministrative
  24. PermitNew Construction
  25. PermitAddition and/or Alteration
  26. PermitAdministrative
  27. PermitNew Construction
  28. InspectionCSUINITIAL
  29. PermitZoning/use
  30. PermitZoning/use
  31. PermitDemolition
  32. InspectionCSUINITIAL
  33. PermitPlumbing
  34. InspectionCSUINITIAL
  35. PermitUse
  36. L&I violationEXTERIOR STRUCT UNSAFE COND 8
  37. L&I violationUNSAFE STRUCTURE
  38. InspectionCSUINITIAL
  39. PermitZoning
  40. PermitZoning
  41. L&I violationWORKMANLIKE- BUILDING CODE
  42. InspectionBP_BLDG
  43. PermitZoning/use
  44. PermitNew construction
  45. InspectionBP_BLDG
  46. L&I violationPERMB- TOTAL DEMOL
  47. L&I violationPERMB- CONST ERECT NEW STRUCT
  48. L&I violationDEBRIS REMOVE - CONSTR
  49. L&I violationSTOP WORK ORDER
  50. InspectionBP_BLDG
  51. PermitAdministrative
  52. InspectionCSUINITIAL
  53. InspectionCSUINITIAL
  54. InspectionCSUINITIAL
  55. InspectionCSUINITIAL
  56. InspectionPRECOURT (likely: pre-court compliance inspection)
  57. InspectionPRECOURT (likely: pre-court compliance inspection)
  58. InspectionCSUINITIAL
  59. InspectionCSUINITIAL
  60. PermitZoning/use
  61. PermitDemolition
  62. PermitMajor alteration
  63. PermitPlumbing
  64. L&I violationWALL DETERIORATED
  65. PermitElectrical
  66. PermitElectrical
  67. PermitElectrical
  68. PermitMajor alteration
  69. InspectionADMIN INSP (likely: administrative inspection)
  70. InspectionBC INSP (likely: building-code inspection)
  71. InspectionBC INSP (likely: building-code inspection)
  72. L&I violationRENEW LIC INDICATED
  73. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  74. InspectionBC INSP (likely: building-code inspection)

Verify the public record

$14,243/year estimated property tax

2026 taxable assessment $1,017,500 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,267,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881068753
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartment building, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartment building Apts 5-50 Units Masonry
Owner
2001-03 Frankford LLC
$ / sq ft
$234 above the $147 median for 2,826 apartments parcels citywide
Corridor
Frankford and Susquehanna city commercial corridor
Interior area
5,407 sqft
Lot size
6,169 sqft
Stories
3
Built
1915
Zoning
CMX2

Recorded owner

Who's behind it

2001-03 Frankford LLC · corporate / LLC owner

• Tax bills mail to 240 E Girard Ave, Philadelphia PA, 19125

Block context

2000 block of Frankford Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 2007-09 Frankford Ave  ·  2011-13 Frankford Ave

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 67 dated rows
  1. PermitAddition and/or Alterations

    Permit MP-2025-006411 · Issued

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.

  2. PermitNew construction, addition, GFA change

    Permit ZP-2025-005037 · Issued

    For the erection of an addition, that includes a residential roof deck with a pilot house. onto the existing attached structure. Size and location per plans.

  3. PermitNew Construction or Additions

    Permit PP-2024-013760 · Issued

    INSTALLING 50 FIXTURES 8 Hot Water Heaters 2 Hose Bibs 8 Kitchen Sinks 8 Washer Machines 8 Lavs 8 Shower Tubs 8 Toilets

  4. PermitNew Construction

    Permit EP-2024-007292 · Issued

    - Wiring throughout according to plans of 8-Residential Units and 2-Commercial Vanilla Box Units - 800A, 3-phase incoming service, 120/208V - 400A, 3-phase for the house panel, which houses the elevator - One commercial space with 100A, single phase panel - One commercial space with 200A, 3-phase electrical panel - Wiring throughout apartments with LED disc lights, decora switches and outlets, hardwired smoke detectors, all by plans provided. - All electric appliances throughout the apartments - All light fixtures (vanity lights, pendant lights, outdoor lights) will be supplied by the owner and installed by us. - Wiring of common area by plans, with exit and emergency signs. Installation shall comply with 2017 NEC. Install new addressable fire alarm system as per 2016 NFPA 72.

  5. PermitNew Construction

    Permit FP-2024-000464 · Issued

    INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE WITH 2 1/2-INCH WILKINS 350AST BACKFLOW PREVENTER AND AUTOMATIC FIRE SUPPRESSION SYSTEM. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.

  6. PermitAddition and/or Alterations

    Permit MP-2024-000925 · Amendment Application Incomplete

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  7. PermitAddition and/or Alteration

    Permit CP-2023-005896 · Issued

    FOR FINISH WORK ONLY AND CO FOR A NEW CONSTRUCTION BUILT AND INSPECTED UNDER AP#881595 WITH AMENDMENT UNDER PERMITS AP#896983 AND AP #944930.

  8. InvestigationL&I investigation

    Case 710475 · PASSED

    The cited inspection visit was marked passed.

  9. InvestigationL&I investigation

    Case 710475 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  10. InvestigationL&I investigation

    Case 710475 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  11. InvestigationL&I investigation

    Case 710475 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  12. PermitAddition and/or Alteration

    Permit EP-2020-008076 · Expired

    Install 1200 AMP service complete with ground. Wire throughout with outlets, switches, lights, GFCI receptacles, and smoke alarms as per 2017 NEC. Install fire alarm system complete per 2016 NFPA 72.

  13. InvestigationL&I investigation

    Case 710475 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  14. PermitRough-In

    Permit 1041567-RI · Expired

    INSTALL 1200AMP SERVICE AND GROUNDING SYSTEM AND WIRE THROUGHOUT AS PER 2008 NEC. (EAST DISTRICT) INSTALL FIRE ALARM WIRE SYSTEM AS PER NFPA 72.

  15. PermitAmend for conversion

    Permit 987776 · Issued

    FOR AN AMENDMENT TO PREVIOUSLY ISSUED NEW CONSTRUCTION PERMIT AP#881595 TO ADD NEW EXTERIOR ADA RAMPS TO THE REAR OF THE FIRST FLOOR, AS PER PLANS; NO OTHER CHANGES ON THIS PERMIT.

  16. PermitNew Construction or Additions

    Permit 967637 · Expired

    INSTALLATION OF WASTE LINES AND WATER LINES, STACKS, HOT WATER TANKS AND SET FIXTURES. 8 WATER CLOSET, 8 LAVS, 8 TUBS, 8 LAUNDRY, 8 KITCHEN SINKS, 2 HOSE BIBS.

  17. ViolationPENALTY- NO PLUMB PERM INFO

    Case 710475 · Violation 211973108 · Code A-901.13/3 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  18. ViolationCOMPL CONCEAL- PLUMB PERM WORK

    Case 710475 · Violation 211973109 · Code A-402.1/4 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  19. InvestigationBP_BLDG

    Case 710475 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  20. PermitNew Construction

    Permit 959500 · Expired

    WIRE MIXED USE BUILDING PER PLANS SUBMITTED 3/21/19 ACCORDING TO 2008 NEC AND NFPA 72(EAST DIST) WIRE MIXED USE BUILDING PER PLANS SUBMITTED 3/21/19 ACCORDING TO 2008 NEC AND NFPA 72(EAST DIST)

  21. PermitNew Construction

    Permit 956366 · Issued

    FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A THREE (3) STORY MIXED-USE STRUCTURE IN ACCORDANCE WITH NFPA 13 TO BE SUPPLIED BY A TWO (2) INCH FIRE SERVICE LINE AND TO INCLUDE A TWO (2) INCH BACKFLOW PREVENTION DEVICE AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  22. PermitPlumbing

    Permit 959244 · COMPLETED

    NEW HD HT FAI WDP INTO BLDG

  23. PermitAdministrative

    Permit 944930 · COMPLETED

    FOR AN AMENDMENT TO PREVIOUSLY ISSUED NEW CONSTRUCTION PERMIT AP#881595 TO ADD MORE UNDERPINNING (SEE PREVIOUSLY ISSUED AMENDED PERMIT AP#896983), AND REVISE EXISTING FOUNDATION WALL BETWEEN 2001-03 AND 2005 FRANKFORD AVENUE, AS PER REVISED PLANS; NO OTHER CHANGES ON THIS PERMIT; USING SAME SPECIAL INSPECTION AGENCY AS AP#896983.

  24. PermitNew Construction

    Permit 950216 · Expired

    INSTALL 8 NEW HVAC SYSTEMS FOR RESIDENTIAL SPACE. NOTE:COMMERCIAL 1ST FLOOR NOT PART OF THIS PERMIT ALL WORK DONE WITHIN THE RATED ASSEMBLIES OF UNITS WORK INSTALLED AS PER MANUFACTURER'S REQUIREMENTS/ FUEL GAS CADE AND EZ WARM AIR STANDARD AS PER NOTARIZED LETTER. CONTRACTOR HAS NO EMPLOYEES

  25. PermitAddition and/or Alteration

    Permit 911906 · Expired

    INTERIOR ALTERATIONS TO INCLUDE NON LOAD BEARING PARTITIONS, UPGRADES TO FINISHES, STRUCTURAL WORK, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  26. PermitAdministrative

    Permit 896983 · COMPLETED

    FOR AN AMENDMENT TO PREVIOUSLY ISSUED NEW CONSTRUCTION PERMIT AP#881595 TO ADD UNDERPINNING (INCL. SPECIAL INSPECTIONS), ALL FLOOR ASSEMBLIES TO BE 1-HOUR RATED, CHANGE CONSTRUCTION TYPE TO TYPE VA (REVISED CO ATTACHED TO THIS PERMIT), REVISE FOUNDATION/FRAMEWALL AT 2005 FRANKFORD AVE, REVISE COMMERCIAL TENANT ENTRANCE AT 2001 FRANKFORD AVE, AND REVISE ELEVATOR LOBBY AND ADD EXTERIOR ADA RAMP, AS PER REVISED PLANS; NO OTHER CHANGES ON THIS PERMIT OR TO PREVIOUSLY ISSUED CORE/SHELL PERMIT AP#770999.

  27. PermitNew Construction

    Permit 881595 · Expired

    **SEPARATE TENANT FIT-OUT (NEWCON) PERMIT REQUIRED FOR COMMERCIAL TENANT(S) ON FIRST FLOOR** FOR TENANT FIT-OUT (NEWCON) ON THE 2ND AND 3RD FLRS OF A NEW, THREE (3) STORY STRUCTURE (AKA 2001-03 FRANKFORD AVE; SEE AP#770999 FOR CORE & SHELL; USING EX. FOUNDATION), AND FOR THE RECONSTRUCTION OF AN EXISTING THREE (3) STORY STRUCTURE (AKA 2005 FRANKFORD AVE), TOGETHER USED AS MULTI-FAMILY HOUSEHOLD LIVING (EIGHT (8) DWELLING UNITS) ON THE 2ND/3RD FLRS, AS PER PLANS; SEPARATE PERMITS REQUIRED ALL MEP/FSP WORK; BUILDING TO BE FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 THROUGHOUT.

  28. InvestigationCSUINITIAL

    Case 606377 · PASSED

    The cited inspection visit was marked passed.

  29. PermitZoning/use

    Permit 841579 · COMPLETED

    FOR THE ERECTION OF AN ATTACHED STRUCTURE (2001-03 FRANKFORD AVE), AND FOR THE RECONSTRUCTION OF AN ABUTTING ATTACHED STRUCTURE (2005 FRANKFORD AVE), BOTH ON THE SAME LOT TO BE USED AS ONE BUILDING, SIZE AND LOCATION AS SHOWN ON PLAN/APPLICATION. FOR USE AS SIT-DOWN RESTAURANT (AT 2001-03 FRANKFORD AVE), AND BUSINESS AND PROFESSIONAL OFFICES (AT 2005 FRANKFORD AVE), ON THE FIRST FLOOR, AS PREVIOUSLY APPROVED (SEE AP#829664), WITH MULTI-FAMILY HOUSEHOLD LIVING (EIGHT (8) DWELLING UNITS) ABOVE; NO SIGNS ON THIS PERMIT.

  30. PermitZoning/use

    Permit 839916 · COMPLETED

    FOR DEMOLITION OF EXISITNG 3-STORY BUILDING IN ACCORDANCE WITH PLANS FOR USE AS A VACANT LOT

  31. PermitDemolition

    Permit 839917 · COMPLETED

    FOR THE DEMOLITION OF A THREE-STORY EXISTING STRUCTURE IN ACCORDANCE WITH PLANS. STRUCTURE TO BE DEMOLISHED BY HAND AND WITH HAND HELD TOOLS ONLY. PEDESTRIAN PROTECTION TO BE IN PLACE PRIOR TO START OF WORK AND TO BE MAINTAINED DURING ALL DEMOLITION ACTIVITIES. * A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 7 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED. * 21 DAY POSTING AND NOTICE REQUIRED PER A-303.2 * NEWLY EXPOSED WALLS TO BE TREATED

  32. InvestigationCSUINITIAL

    Case 606377 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  33. PermitPlumbing

    Permit 838125 · COMPLETED

    REMOVE HOUSE TRAP AND SEAL THE LATERAL PA20173412939(SFD)

  34. InvestigationCSUINITIAL

    Case 606377 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  35. PermitUse

    Permit 829664 · COMPLETED

    FOR A SIT-DOWN RESTAURANT AT SPACE# 1 AND BUSINESS AND PROFESSIONAL OFFICE AT SPACE # 2 AT FIRST FLOOR IN THE SAME BUILDING WITH MULTI-FAMILY HOUSEHOLD LIVING (EIGHT(8) DWELLING UNITS) FROM SECOND FLOOR THROUGH THIRD FLOORS. NO SIGN ON THIS APPLICATION.

  36. ViolationEXTERIOR STRUCT UNSAFE COND 8

    Case 606377 · Violation 4535421 · Code PM15-304.1H · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  37. ViolationUNSAFE STRUCTURE

    Case 606377 · Violation 4535420 · Code PM15-108.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  38. InvestigationCSUINITIAL

    Case 606377 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  39. PermitZoning

    Permit 796302 · COMPLETED

    FOR A LOT LINE ADJUSTMENT TO CREATE ONE LOT FROM TWO EXISTING LOTS (2001-03 FRANKFORD AVE AND 2005 FRANKFORD AVE). SIZE AND LOCATION AS PER PLAN. NO CHANGE IN HEIGHT OR AREA OF ANY EXISTING STRUCTURES.

  40. PermitZoning

    Permit 804825 · COMPLETED

    FOR A LOT LINE ADJUSTMENT TO CREATE ONE LOT FROM TWO EXISTING LOTS (2001-03 FRANKFORD AVE AND 2005 FRANKFORD AVE). SIZE AND LOCATION AS PER PLAN. NO CHANGE IN HEIGHT OR AREA OF ANY EXISTING STRUCTURES.

  41. ViolationWORKMANLIKE- BUILDING CODE

    Case 770999 · Violation 4548671 · Code A-104.1/1 · CLOSEDCASE

    City marked the case closed; that does not mean the original condition never existed.

  42. InvestigationBP_BLDG

    Case 576086 · PASSED

    The cited inspection visit was marked passed.

  43. PermitZoning/use

    Permit 771009 · COMPLETED

    FOR THE ERECTION OF AN ATTACHED BUILDING. SIZE AND LOCATION AS SHOWN ON APPROVED PLANS. FOR VACANT COMMERCIAL SPACE ON GROUND FLOOR (SEPARATE USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) AND MULTIFAMILY HOUSEHOLD LIVING (SIX (6) DWELLING UNITS) ABOVE. NO SIGNS ON THIS APPLICATION.

  44. PermitNew construction

    Permit 770999 · COMPLETED

    FOR THE ERECTION OF THREE (3) STORY BUILDING - CORE AND SHELL ONLY. SEPARATE PERMITS REQUIRED FOR TENANT FIT OUTS PRIOR TO OCCUPANCY. SEPARATE PERMITS REQUIRED FOR ALL M.E.P. AND FIRE SUPPRESSION WORK. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 THROUGHOUT.

  45. InvestigationBP_BLDG

    Case 576086 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  46. ViolationPERMB- TOTAL DEMOL

    Case 576086 · Violation 4293689 · Code A-301.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  47. ViolationPERMB- CONST ERECT NEW STRUCT

    Case 576086 · Violation 4293688 · Code A-301.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  48. ViolationDEBRIS REMOVE - CONSTR

    Case 576086 · Violation 4293687 · Code A-104.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  49. ViolationSTOP WORK ORDER

    Case 576086 · Violation 4293690 · Code A-504.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  50. InvestigationBP_BLDG

    Case 576086 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  51. PermitAdministrative

    Permit 756518 · COMPLETED

    AMEND PERMIT #731388 TO THE DEMOLITION COURTYARD FACING WALLS THAT HAD TO BE REMOVED DUE TO STRUCTURAL INSTABILITY IDENTIFIED DURING THE DEMOLITION PROCESS.

  52. InvestigationCSUINITIAL

    Case 221673 · CLOSED

    City marked the record closed; open the case for the closing reason.

  53. PermitZoning/use

    Permit 737686 · COMPLETED

    REMOVE EXISTING GARAGE EXTERIOR MASONRY WALLS, DOORS AND EXISTING ROOFIN

  54. PermitDemolition

    Permit 737687 · COMPLETED

    REMOVE EXISTING GARAGE EXTERIOR MASONRY WALLS, DOORS AND EXISTING ROOF IN THEIR ENTIRETY

  55. PermitMajor alteration

    Permit 731388 · COMPLETED

    MAKE SAFE PERMIT - FOR (BRIEF DESCRIPTION OF WORK AS PER ENGINEER’S REPORT IF APPLICABLE) TO RESOLVE CASE #221673. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6’ IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #221673.PERMIT TO COMPLY WITH VIOLATIONS

  56. PermitPlumbing

    Permit 564743 · COMPLETED

    NEW 3/4" BACK FLOW PREVENTOR AT BASEMENT FRONT WALL- WATTS #009 LF

  57. ViolationWALL DETERIORATED

    Case 221673 · Violation 4011453 · Code PM-307.1/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  58. PermitElectrical

    Permit 257507 · COMPLETED

    INSTALL (6) EXTERIOR LIGHT FIXTURES ON 1 PHOTO CELL, (2) GFI RECEPTACLES - EXTERIOR AS PER 2005 NEC (EAST DIST)

  59. PermitElectrical

    Permit 246284 · ABANDONED

    INSTALL 6 NEW EXTERIOR LIGHT FIXTURES AS PER 2005 NEC (EAST DISTRICT)

  60. PermitElectrical

    Permit 224840 · COMPLETED

    INSTALL NEW 200AMP SERVICE & 4 METER, 4 PANELS AS PER 2005 NEC (EAST DISTRICT)

  61. PermitMajor alteration

    Permit 148223 · EXPIRED

    REPAIR BRICK FACADE AS PER PLANS/REPORT

  62. InvestigationADMIN INSP (likely: administrative inspection)

    Case 123256 · PASSED

    Legacy inspection shorthand; the title alone does not state what condition was examined. The cited inspection visit was marked passed.

  63. InvestigationBC INSP (likely: building-code inspection)

    Case 123256 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  64. InvestigationBC INSP (likely: building-code inspection)

    Case 123256 · CLOSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.

  65. ViolationRENEW LIC INDICATED

    Case 123256 · Violation 721839 · Code LR-1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  66. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 123256 · Violation 721840 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.

  67. InvestigationBC INSP (likely: building-code inspection)

    Case 123256 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 5:56 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)