Apartment building report

2215 E Tioga St

3 stories5,184 sqftICMXbuilt 2022

Property at a glanceApartments

East Tioga Lofts LLC

2026 assessment
$6.3M OPA value, not a listing price
2027 published assessment
$6.9M Future roll, not the current tax bill
Neighborhood area
Port Richmond · Kensington Approximate · based on ZIP 19134
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $6,924,200. It is not yet the billed-year tax basis.

$0$5.0M$10M$6.9M2011201420172020202320262027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record62 events · exact dates, newest first
  1. CertificationSprinkler Certification
  2. CertificationSprinkler Certification
  3. CertificationFire Alarm Certification
  4. CertificationSprinkler Certification
  5. CertificationFire Alarm Certification
  6. LicenseEast Tioga Lofts LLC: Rental landlord or residential registration initially issued
  7. PermitNew Construction or Additions
  8. PermitSitework with Onsite Utility Services
  9. PermitAddition and/or Alterations
  10. PermitRough-In
  11. PermitNew Construction or Additions
  12. PermitNew Construction or Additions
  13. PermitNew Construction or Additions
  14. PermitNew Construction or Additions
  15. PermitNew Construction or Additions
  16. PermitNew Construction
  17. PermitAddition and/or Alteration
  18. PermitNew Construction
  19. PermitNew Construction
  20. PermitNew Construction
  21. PermitNew Construction
  22. PermitNew Construction
  23. PermitNew Construction
  24. PermitNew Construction
  25. PermitNew Construction or Additions
  26. PermitNew Construction
  27. PermitNew Construction
  28. PermitNew Construction
  29. PermitRough-In
  30. PermitRough-In
  31. PermitRough-In
  32. PermitRough-In
  33. PermitRough-In
  34. PermitRough-In
  35. PermitNew Construction
  36. PermitNew Construction or Additions
  37. PermitRough-In
  38. PermitRough-In
  39. PermitNew Construction
  40. PermitNew Construction
  41. PermitNew Construction
  42. PermitNew Construction
  43. PermitAddition and/or Alteration
  44. PermitNew Construction
  45. PermitNew Construction
  46. PermitNew Construction
  47. PermitNew Construction
  48. PermitNew Construction
  49. PermitNew Construction
  50. AppealZBA Permit Denial - Variance
  51. PermitNew construction, addition, GFA change
  52. LicenseChristina M. Brennan: Vacant Commercial Property L&I license filing marked inactive
  53. InspectionL&I investigation
  54. InspectionL&I investigation
  55. LicenseChristina M. Brennan: Vacant Commercial Property L&I license filing initially issued
  56. L&I violationFIRE PROTECTION/VACANT BUILDIN
  57. L&I violationFIRE ALARM TESTED/CERTIFIED
  58. L&I violationFIRE SUPPRESSION CERTIFICATION
  59. L&I violationFIRE ALARM MONITORING
  60. L&I violationPLUMBING SYSTEMS-GENERAL
  61. LicenseJOHN ROSS: Dumpster License - Private Property L&I license filing marked inactive
  62. LicenseJOHN ROSS: Dumpster License - Private Property L&I license filing initially issued

Verify the public record

$11,292/year estimated property tax

2026 taxable assessment $806,702 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $6,924,200. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881000476
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $806,702 of $6,306,200 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartments, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartments Ind. Lght Mfg Masonry
Owner
East Tioga Lofts LLC
$ / sq ft
$1336 above the $147 median for 2,826 apartments parcels citywide
Licensed units
45 active rental license
Interior area
5,184 sqft
Lot size
27,900 sqft
Stories
3
Built
2022
Zoning
ICMX

Recorded owner

Who's behind it

East Tioga Lofts LLC · corporate / LLC owner

• Tax bills mail to 9450 Sw Gemini Dr, Beaverton OR, 97008 — outside Philadelphia
• Holds an active rental license for this address

Block context

2200 block of E Tioga St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 2201 E Tioga St  ·  2245 E Tioga St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 24, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

East Tioga Lofts LLCActive

Rental · Initial issue date Nov 9, 2022 · Filed expiration Nov 8, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 62 dated rows
  1. CertificationSprinkler Certification

    Certification BC-2026-002789 · Certified

    Expires 2027-01-05

  2. CertificationSprinkler Certification

    Certification BC-2025-015085 · Certified

    Expires 2026-04-10

  3. CertificationFire Alarm Certification

    Certification BC-2024-021955 · Certified

    Expires 2025-08-01

  4. CertificationSprinkler Certification

    Certification BC-2023-026103 · Certified

    Expires 2024-10-19

  5. CertificationFire Alarm Certification

    Certification BC-2023-016904 · Certified

    Expires 2024-08-15

  6. License issue eventEast Tioga Lofts LLC: Rental landlord or residential registration initially issued

    License 910326 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  7. PermitNew Construction or Additions

    Permit PP-2022-011035 · Completed

    Plumbing Permit for combo SP-2022-000394

  8. PermitSitework with Onsite Utility Services

    Permit SP-2022-000394 · Expired

    2 trough drains and one class 1 inlet

  9. PermitAddition and/or Alterations

    Permit FP-2022-000925 · Completed

    For the installation of an automatic wet sprinkler system in accordance with NFPA 13 (using an existing, six (6) inch fire service line as per PWD Utility Plan dated 10/29/2021, and a new, six (6) inch backflow prevention device located within the basement), throughout an existing two (2) story semi-detached structure to be used as Group R-2, as per plans and hydraulic calculations; see CP-2021-000081 for building permit.

  10. PermitRough-In

    Permit FP-2022-000997 · Expired

    Rough-In Permit for FP-2022-000925 (CP-2021-000081)

  11. PermitNew Construction or Additions

    Permit PP-2021-023477 · Completed

    Installation of 4 toilets 4 lavs 4 tubs 2 laundry 2 kitchen sinks 2 hot water heaters 2 1" water services curb trap/FAi

  12. PermitNew Construction or Additions

    Permit PP-2021-022580 · Completed

    Installation of 4 toilets 4 lavs 4 tubs 2 laundry 2 kitchen sinks 2 1" water services curb trap/FAi

  13. PermitNew Construction or Additions

    Permit PP-2021-023641 · Completed

    Installation of 4 toilets 4 lavs 4 tubs 2 laundry 2 kitchen sinks 2 1" water services curb trap/FAi

  14. PermitNew Construction or Additions

    Permit PP-2021-023465 · Completed

    Installation of 4 toilets 4 lavs 4 tubs 2 laundry 2 kitchen sinks 2 1" water services curb trap/FAi

  15. PermitNew Construction or Additions

    Permit PP-2021-023464 · Completed

    Installation of 4 toilets 4 lavs 4 tubs 2 laundry 2 kitchen sinks 2 1" water services curb trap/FAi

  16. PermitNew Construction

    Permit EP-2021-002266 · Completed

    ERECTION OF AN ATTACHED STRUCTURE FOR USE AS TWO FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEO TECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13D) WORK. (UNDERPINNNING IS NOT PART OF THIS PERMIT). ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. Amendment: I wish to change my inspection agency from United Inspection to Middle Department Inspection Agency. United was selected incorrectly, all other permits at this property under my name are with Middle Department and i wish to keep that consistent.

  17. PermitAddition and/or Alteration

    Permit EP-2021-010816 · Completed

    New 1200 amp service. Wire building as per plans and 2017 NEC. Install new fire alarm system as per nfpa 72

  18. PermitNew Construction

    Permit EP-2021-002267 · Completed

    Electrical Permit for combo RP-2021-000246 Amendment: I wish to change my inspection agency from United Inspection to Middle Department Inspection Agency. United was selected incorrectly, all other permits at this property under my name are with Middle Department and i wish to keep that consistent.

  19. PermitNew Construction

    Permit FP-2021-003169 · Completed

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2013, STANDARD 13D TO INCLUDE A ONE (1)-INCH DIAMETER COMBINED SERVICE LINE. 2/14/2022: FOR AMENDMENT TO REVISE THE SPRINKLER CONFIGURATION AT THE THIRD STORY.

  20. PermitNew Construction

    Permit FP-2021-003162 · Completed

    INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13D THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 1" MAIN FIRE SERVICE LINE PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. AMENDED AS OF 2/11/2022 FOR THE RELOCATIN/REMOVAL OF ONE(1) SPRINKLER HEAD AS PER APPROVED PLANS.

  21. PermitNew Construction

    Permit FP-2021-003171 · Completed

    FOR THE INSTALLTION OF A FRE SUPPRESION SYSTEM IN ACCORDANCE WITH NFPA 2013, STANDARD 13D TO INCLUDE A ONE (1)-INCH DIAMETER COMBINED SERVICE LINE. 1/27/2022: FOR AMENDMENT TO REVISE SPRINKLER CONFIGURATION AT THE 3RD STORY LEVEL WITH THE REMOVAL OF ONE (1) HEAD.

  22. PermitNew Construction

    Permit FP-2021-003166 · Completed

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2013, STANDARD 13D TO INCLUDE A ONE (1)-INCH DIAMETER COMBINED SERVICE LINE. 2/14/2022: FOR AMENDMENT TO REVISE THE SPRINKLER CONFIGURATION AT THE THIRD STORY.

  23. PermitNew Construction

    Permit FP-2021-003163 · Completed

    INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13D THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 1" MAIN FIRE SERVICE LINE PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. AMENDED AS OF 2/11/2022 FOR THE RELOCATION/ REMOVAL OF A SPRINKLER HEAD AS PER APPROVED PLANS.

  24. PermitNew Construction

    Permit FP-2021-003165 · Completed

    INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13D THROUGHOUT AN EXISTING STRUCTURE. INSTALLATION TO INCLUDE 1" MAIN FIRE SERVICE LINE PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. AMENDED AS OF 2/6/2022 FOR THE REMOVAL OF A SPRINKLER HEAD AS PER APPROVED PLANS.

  25. PermitNew Construction or Additions

    Permit PP-2021-023455 · Completed

    Installation of 4 toilets 4 lavs 4 tubs 2 laundry 2 kitchen sinks 2 1" water services curb trap/FAi MD

  26. PermitNew Construction

    Permit EP-2021-001960 · Completed

    Electrical Permit for combo RP-2021-000240 Amendment: I wish to change my inspection agency from United Inspection to Middle Department Inspection Agency. United was selected incorrectly, all other permits at this property under my name are with Middle Department and i wish to keep that consistent.

  27. PermitNew Construction

    Permit MP-2021-004752 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (Installation of one 2 ton heat pump system and installation of one 2 1/2 ton heat pump system).

  28. PermitNew Construction

    Permit MP-2021-004747 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (Installation of one 2 ton heat pump system and installation of one 2 1/2 ton heat pump system).

  29. PermitRough-In

    Permit FP-2021-003256 · Expired

    Rough-In Permit for FP-2021-003169 (RP-2021-000246) Unit 05

  30. PermitRough-In

    Permit FP-2021-003258 · Completed

    Rough-In Permit for FP-2021-003171 (RP-2021-000249) Unit 06

  31. PermitRough-In

    Permit FP-2021-003248 · Expired

    Rough-In Permit for FP-2021-003162 (RP-2021-000238) Unit 01

  32. PermitRough-In

    Permit FP-2021-003250 · Expired

    Rough-In Permit for FP-2021-003163 (RP-2021-000242) Unit 04

  33. PermitRough-In

    Permit FP-2021-003252 · Expired

    Rough-In Permit for FP-2021-003165 (RP-2021-000240) Unit 02

  34. PermitRough-In

    Permit FP-2021-003253 · Completed

    Rough-In Permit for FP-2021-003166 (RP-2021-000241) Unit 3

  35. PermitNew Construction

    Permit MP-2021-004755 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (Installation of one 2 ton heat pump system and installation of one 2 1/2 ton heat pump system. 10 Diffusers Total).

  36. PermitNew Construction or Additions

    Permit PP-2021-009402 · Completed

    Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018.

  37. PermitRough-In

    Permit PP-2020-013749 · Completed

    Rough in 32 apts unit 32 bathrooms 32 kitchen sinks 32 laundry

  38. PermitRough-In

    Permit EP-2021-010820 · Expired

    Rough-In Permit for EP-2021-010816 New 1200 amp service. Wire building as per plans and 2014 NEC. Install new fire alarm system as per nfpa 72

  39. PermitNew Construction

    Permit MP-2021-004749 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (Installation of one 2 ton heat pump system and installation of one 2 1/2 ton heat pump system).

  40. PermitNew Construction

    Permit MP-2021-004751 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. EACH HVAC UNIT TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT. NO PENETRATIONS OF RATED ASSEMBLIES. (Installation of one 2 ton heat pump system and installation of one 2 1/2 ton heat pump system).

  41. PermitNew Construction

    Permit MP-2021-004739 · Completed

    Installation of one 2 ton heat pump system and one 2 1/2 ton heat pump system..

  42. PermitNew Construction

    Permit MP-2021-004770 · Completed

    For the installation of mechanical work to include registers/diffusers, supply/exhaust ductwork, appliances, rooftop units, and all other work as per approved plans.

  43. PermitAddition and/or Alteration

    Permit CP-2021-000081 · Completed

    For addition to the existing warehouse struture with level III alteration throughout the existing detached structure with complete change of occupancy classification to create a multi-family apartment buidling as per approved plans. Building to be fully sprinklered. Asbestos to be removed prior to occupancy. Separate permits required for M.E.P.S. work. Amendment to revise scope to reduce dwelling units from 35 to 33 dwelling units and remove addition from scope of work. Amendment to include sitework.

  44. PermitNew Construction

    Permit RP-2021-000240 · Completed

    ERECTION OF AN ATTACHED STRUCTURE FOR USE AS TWO FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEO TECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13D) WORK. (UNDERPINNNING IS NOT PART OF THIS PERMIT). ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. Permit Amendment 4-15-2021 Foundation revisions to change from precast foundations to poured concrete foundation

  45. PermitNew Construction

    Permit RP-2021-000238 · Completed

    ERECTION OF AN ATTACHED STRUCTURE FOR USE AS TWO FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEO TECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13D) WORK. (UNDERPINNNING IS NOT PART OF THIS PERMIT). ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. Amend Permit 4-6-2021 Foundation revisions to change from precast foundations to poured concrete foundation

  46. PermitNew Construction

    Permit RP-2021-000241 · Completed

    ERECTION OF AN ATTACHED STRUCTURE FOR USE AS TWO FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEO TECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13D) WORK. (UNDERPINNNING IS NOT PART OF THIS PERMIT). ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. Amend Permit 4-6-2021 Foundation revisions to change from precast foundations to poured concrete foundation

  47. PermitNew Construction

    Permit RP-2021-000246 · Completed

    ERECTION OF AN ATTACHED STRUCTURE FOR USE AS TWO FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEO TECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13D) WORK. (UNDERPINNNING IS NOT PART OF THIS PERMIT). ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. Amend Permit 4-6-2021 Foundation revisions to change from precast foundations to poured concrete foundation

  48. PermitNew Construction

    Permit RP-2021-000242 · Completed

    ERECTION OF AN ATTACHED STRUCTURE FOR USE AS TWO FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEO TECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13D) WORK. (UNDERPINNNING IS NOT PART OF THIS PERMIT). ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. Amend Permit 4-6-2021 Foundation revisions to change from precast foundations to poured concrete foundation

  49. PermitNew Construction

    Permit RP-2021-000249 · Completed

    ERECTION OF AN ATTACHED STRUCTURE FOR USE AS TWO FAMILY HOUSEHOLD LIVING. SHEETING AND SHORING AS PRESCRIBED IN GEO TECH REPORT. SEPARATE PERMITS REQUIRED FOR SPRINKLER (13D) WORK. (UNDERPINNNING IS NOT PART OF THIS PERMIT). ENERGY CODE COMPLIANCE IN ACCORDANCE WITH 2018 IECC. PRIOR TO ISSUANCE OF C.O SUBMITTAL OF AIR BARRIER CHECKLIST AND ENVELOPE TESTING CERTIFICATE IS REQUIRED. BOTH TO BE COMPLETED BY AN APPROVED PARTY. Amend Permit 4-6-2021 Foundation revisions to change from precast foundations to poured concrete foundation

  50. AppealZBA Permit Denial - Variance

    Appeal HA-2020-001391 · In Process · Complete

    Related permit 1050117 · See refusal

  51. PermitNew construction, addition, GFA change

    Permit 1050117 · Completed

    FOR THE ERECTION OF ONE(1) STORY AND TWO(2) STORY ADDITION OF AN EXISTING STRUCTURE ( E TIOGA STREET FRONTAGE); FOR THE ERECTION OF ONE(1) DETACHED STRUCTURE ( NTE 60' HIGH)( NORTH END OF THE PROPERTY). SIZE AND LOCATION AS SHOWN IN THE APPLICATION

  52. License terminal eventChristina M. Brennan: Vacant Commercial Property L&I license filing marked inactive

    License 819027 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  53. InvestigationL&I investigation

    Case 672560 · PASSED

    The cited inspection visit was marked passed.

  54. InvestigationL&I investigation

    Case 672560 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  55. License issue eventChristina M. Brennan: Vacant Commercial Property L&I license filing initially issued

    License 819027 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  56. ViolationFIRE PROTECTION/VACANT BUILDIN

    Case 672560 · Violation 211958566 · Code FC-13-311.22 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  57. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 672560 · Violation 211958523 · Code FC-13-915.1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  58. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 672560 · Violation 211958525 · Code FC-13-915.1A · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  59. ViolationFIRE ALARM MONITORING

    Case 672560 · Violation 211958522 · Code FC-13-901111 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  60. ViolationPLUMBING SYSTEMS-GENERAL

    Case 672560 · Violation 211958567 · Code PM15-504.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  61. License terminal eventJOHN ROSS: Dumpster License - Private Property L&I license filing marked inactive

    License 541161 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  62. License issue eventJOHN ROSS: Dumpster License - Private Property L&I license filing initially issued

    License 541161 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 10:32 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)