Property report

2929l Walnut St

18 stories319,590 sqftbuilt 2015

Property at a glanceOffices

Individual owner on record

2026 assessment
$280M OPA value, not a listing price
2027 published assessment
$282M Future roll, not the current tax bill
Neighborhood area
University City · West Powelton Approximate · based on ZIP 19104
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $282,218,900. It is not yet the billed-year tax basis.

$0$250M$500M$282M2016201820202022202420262027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record158 events · exact dates, newest first
  1. InspectionL&I investigation
  2. InspectionL&I investigation
  3. L&I violationFIRE RESISTANCE RATED CONSTRUCTION
  4. L&I violationDOOR OPERATIONS
  5. L&I violationRELIABILITY
  6. L&I violationHAZARD IDENTIFICATION SIGNS
  7. L&I violationSELF- OR AUTOMATIC-CLOSING DOORS
  8. L&I violationWASTE & LINEN CHUTES
  9. L&I violationUNAPPROVED CONDITIONS
  10. L&I violationINSPECTION, TESTING AND MAINTENANCE
  11. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  12. L&I violationPERIODIC TESTING
  13. L&I violationRECORD KEEPING
  14. PermitAddition and/or Alteration
  15. PermitAddition and/or Alterations
  16. PermitAddition and/or Alterations
  17. PermitAddition and/or Alteration
  18. PermitAddition and/or Alteration
  19. PermitAddition and/or Alteration
  20. PermitAddition and/or Alteration
  21. PermitAddition and/or Alterations
  22. PermitAlterations
  23. PermitAddition and/or Alteration
  24. PermitAddition and/or Alterations
  25. PermitAddition and/or Alteration
  26. PermitAddition and/or Alteration
  27. LicenseHazardous Materials initially issued
  28. InspectionL&I investigation
  29. L&I violationFDC SIGNAGE REQUIRED
  30. InspectionL&I investigation
  31. L&I violationCERTIFICATION
  32. L&I violationSECURING COMPRESSED CYLINDERS
  33. L&I violationNFPA 704 SIGNS
  34. L&I violationPULL STATION SIGNS
  35. L&I violationFIREBLOCKING/DRAFTSTOPPING
  36. L&I violationHAZMAT LICENSE REQUIRED
  37. L&I violationSTANDBY POWER SYSTEM TESTED
  38. L&I violationSTORAGE MEANS OF EGRESS
  39. L&I violationSTORAGE
  40. PermitAlterations
  41. PermitAddition and/or Alteration
  42. PermitAddition and/or Alterations
  43. PermitElectrical
  44. PermitElectrical
  45. PermitMechanical
  46. PermitElectrical
  47. PermitSuppression
  48. PermitMajor alteration
  49. PermitMechanical
  50. PermitAdministrative
  51. PermitElectrical
  52. PermitElectrical
  53. PermitSuppression
  54. PermitElectrical
  55. PermitPlumbing
  56. PermitElectrical
  57. PermitMajor alteration
  58. PermitPlumbing
  59. PermitElectrical
  60. PermitElectrical
  61. PermitMechanical
  62. PermitMechanical
  63. PermitElectrical
  64. PermitSuppression
  65. PermitPlumbing
  66. PermitMajor alteration
  67. PermitElectrical
  68. PermitMechanical
  69. LicenseHigh Rise initially issued
  70. PermitElectrical
  71. PermitPlumbing
  72. PermitAdministrative
  73. LicenseRental initially issued
  74. PermitSuppression
  75. PermitElectrical
  76. PermitMajor alteration
  77. InspectionEP_ELEC
  78. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  79. PermitAdministrative
  80. InspectionEP_ELEC
  81. PermitMechanical
  82. PermitElectrical
  83. L&I violationELECTRICAL AGENCY
  84. L&I violationELECTRICAL INSPECTOR
  85. InspectionEP_ELEC
  86. PermitElectrical
  87. PermitNew construction
  88. PermitElectrical
  89. PermitElectrical
  90. L&I violationFIRE ALARM TESTED/CERTIFIED
  91. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  92. PermitElectrical
  93. PermitElectrical
  94. PermitElectrical
  95. PermitMechanical
  96. L&I violationBOX-NEEDED AT TERMINATION
  97. L&I violationPENALTY- NO ELEC PERM INFO
  98. L&I violationPERME- ALTER ELEC INSTALLATION
  99. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  100. InspectionEP_ELEC
  101. PermitSuppression
  102. PermitPlumbing
  103. PermitPlumbing
  104. PermitAdministrative
  105. PermitSuppression
  106. PermitNew construction
  107. PermitNew construction
  108. PermitNew construction
  109. PermitAdministrative
  110. PermitSuppression
  111. PermitElectrical
  112. PermitElectrical
  113. PermitAdministrative
  114. PermitAdministrative
  115. PermitSuppression
  116. PermitMechanical
  117. PermitAdministrative
  118. PermitPlumbing
  119. PermitNew construction
  120. PermitSuppression
  121. PermitSuppression
  122. PermitAdministrative
  123. PermitElectrical
  124. PermitElectrical
  125. PermitElectrical
  126. PermitAdministrative
  127. PermitDemolition
  128. PermitMechanical
  129. PermitMechanical
  130. PermitMechanical
  131. PermitSuppression
  132. PermitNew construction
  133. PermitAdministrative
  134. PermitAdministrative
  135. PermitSuppression
  136. PermitPlumbing
  137. PermitElectrical
  138. PermitAdministrative
  139. AppealBuilding standards appeal
  140. PermitAdministrative
  141. PermitPlumbing
  142. PermitElectrical
  143. PermitElectrical
  144. PermitAdministrative
  145. PermitNew construction
  146. PermitZoning/use
  147. PermitPlumbing
  148. PermitMechanical
  149. PermitSuppression
  150. PermitNew construction
  151. PermitAlteration
  152. PermitAdministrative
  153. PermitSuppression
  154. PermitAdministrative
  155. PermitElectrical
  156. PermitMechanical
  157. PermitPlumbing
  158. PermitSuppression

Verify the public record

$3,925,276/year estimated property tax

2026 taxable assessment $280,416,900 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $282,218,900. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 883063410
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Offices, recorded in the City's offices category. The public record and owner trail follow.

11 open violations

What it is
Offices Air Rights Commercial
Owner
Individual owner on record Individual name redacted
$ / sq ft
$883 above the $142 median for 753 offices parcels citywide
Corridor
30th Street city commercial corridor
Licensed units
165 active rental license
Interior area
319,590 sqft
Stories
18
Built
2015

Block context

2900 block of Walnut St. Compare parcels, ownership, and public-record history.

See the whole block →
Open every source row 158 dated rows
  1. InvestigationL&I investigation

    Case CF-2026-060075 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  2. InvestigationL&I investigation

    Case CF-2026-060075 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  3. ViolationFIRE RESISTANCE RATED CONSTRUCTION

    Case CF-2026-060075 · Violation VI-2026-036638 · Code F-701.2 · OPEN

  4. ViolationDOOR OPERATIONS

    Case CF-2026-060075 · Violation VI-2026-036639 · Code F-1010.1.9 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  5. ViolationRELIABILITY

    Case CF-2026-060075 · Violation VI-2026-036642 · Code F-1031.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  6. ViolationHAZARD IDENTIFICATION SIGNS

    Case CF-2026-060075 · Violation VI-2026-036643 · Code F-5003.5 · OPEN

  7. ViolationSELF- OR AUTOMATIC-CLOSING DOORS

    Case CF-2026-060075 · Violation VI-2026-036636 · Code F-1105.5.4.2.4 · OPEN

  8. ViolationWASTE & LINEN CHUTES

    Case CF-2026-060075 · Violation VI-2026-036637 · Code F-1103.4.9 · OPEN

  9. ViolationUNAPPROVED CONDITIONS

    Case CF-2026-060075 · Violation VI-2026-036551 · Code F-604.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  10. ViolationINSPECTION, TESTING AND MAINTENANCE

    Case CF-2026-060075 · Violation VI-2026-036543 · Code F-907.8.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  11. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2026-060075 · Violation VI-2026-036542 · Code F-903.5 · OPEN

  12. ViolationPERIODIC TESTING

    Case CF-2026-060075 · Violation VI-2026-036541 · Code F-901.6.4 · OPEN

  13. ViolationRECORD KEEPING

    Case CF-2026-060075 · Violation VI-2026-036552 · Code F-405.5 · OPEN

  14. PermitAddition and/or Alteration

    Permit EP-2023-012176 · Completed

    Fire Alarm: Relocate 2 strobe, Install 1 speaker/strobe, 3 strobes. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.

  15. PermitAddition and/or Alterations

    Permit FP-2023-002857 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (14) sprinkler heads to accommodate interior alterations on 16th and 17th floors

  16. PermitAddition and/or Alterations

    Permit MP-2023-004935 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE OFFICE LAYOUT CHANGES ON THE 16TH AND 17TH FLOORS OF AN EXISTING HIGH RISE OFFICE BUILDING AS PER APPROVED PLANS. *2018 IMC REVIEW*

  17. PermitAddition and/or Alteration

    Permit EP-2023-011009 · Completed

    Relocate (6) light fixtures. Install (4) light fixtures, (10) switches, (22) receptacles, (8) floor receptacles, (1) furniture power as per 2017 NEC.

  18. PermitAddition and/or Alteration

    Permit CP-2023-006189 · Completed

    For a level II interior alteration without change of occupancy classification on the 16th & 17th floors of the high-rise office building. Building is fully sprinklered.** work to be completed per approved plans** If field conditions vary ,please contact the design professional prior to start of work**Separate permits required for M.E.P.S work.**

  19. PermitAddition and/or Alteration

    Permit EP-2022-000976 · Expired

    Video Surveillance & Access Control Equipment, tele comm with longest 270' plenum.

  20. PermitAddition and/or Alteration

    Permit EP-2021-012802 · Completed

    Fire Alarm: Install (4) strobe, (8) speaker/strobe, relocate (1) speaker/strobe. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  21. PermitAddition and/or Alterations

    Permit FP-2021-002838 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (111) sprinklers heads on the 16th and 17th floors. (CP-2021-004728)

  22. PermitAlterations

    Permit PP-2021-016891 · Completed

    INSTALL 5 HOT WATER HEATERS AND 5 KITCHEN SINKS ACCORDING TO THE 2018 PPC.

  23. PermitAddition and/or Alteration

    Permit EP-2021-010613 · Completed

    Install (139) light fixture, (59) switch, (22) power pack, (114) receptacle, (23) furniture feed, (31) floor receptacle, (4) equipment power, (2) meter, (2) transformer, (2) 208/120 volt panel as per 2017 NEC.

  24. PermitAddition and/or Alterations

    Permit MP-2021-005919 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT ON THE 16TH AND 17TH FLOORS OF AN EXISTING HIGHRISE BUILDING AS PER APPROVED PLANS. *2018 IMC REVIEW*

  25. PermitAddition and/or Alteration

    Permit CP-2021-004728 · Completed

    For level II interior alteration without change of occupancy classification on the 16th & 17th floors of the high-rise office building. Building is fully sprinklered. Separate permits required for M.E.P.S work.

  26. PermitAddition and/or Alteration

    Permit EP-2021-008720 · Completed

    Data Cabling. 21 cables in total. Rough in and terminate all cables to existing Telecom Room. AS PER NEC 2017

  27. License issue eventHazardous Materials initially issued

    License 866792 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  28. InvestigationL&I investigation

    Case CF-2020-087922 · PASSED

    The cited inspection visit was marked passed.

  29. ViolationFDC SIGNAGE REQUIRED

    Case CF-2020-087922 · Violation VI-2020-053386 · Code FC-13-912.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  30. InvestigationL&I investigation

    Case CF-2020-087922 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  31. ViolationCERTIFICATION

    Case CF-2020-087922 · Violation VI-2020-053387 · Code FC-13-915 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  32. ViolationSECURING COMPRESSED CYLINDERS

    Case CF-2020-087922 · Violation VI-2020-053388 · Code FC-13-3003.5.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  33. ViolationNFPA 704 SIGNS

    Case CF-2020-087922 · Violation VI-2020-053379 · Code FC-13-2703.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  34. ViolationPULL STATION SIGNS

    Case CF-2020-087922 · Violation VI-2020-053380 · Code FC-13-907.5.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  35. ViolationFIREBLOCKING/DRAFTSTOPPING

    Case CF-2020-087922 · Violation VI-2020-053381 · Code FC-13-703.1.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  36. ViolationHAZMAT LICENSE REQUIRED

    Case CF-2020-087922 · Violation VI-2020-053382 · Code FC-13-2701.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  37. ViolationSTANDBY POWER SYSTEM TESTED

    Case CF-2020-087922 · Violation VI-2020-053383 · Code FC-13-604.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  38. ViolationSTORAGE MEANS OF EGRESS

    Case CF-2020-087922 · Violation VI-2020-053384 · Code FC-13-315.2.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  39. ViolationSTORAGE

    Case CF-2020-087922 · Violation VI-2020-053385 · Code FC-13-304.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  40. PermitAlterations

    Permit PP-2020-007940 · Expired

    Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018.

  41. PermitAddition and/or Alteration

    Permit EP-2020-004692 · Completed

    Renovation to existing 11th floor corridor. install (25) light fixture, (3) exit, (6) switch, (3) fire alarm speaker/strobe, relocate (3) fire alarm device . ALL WORK TO BE DONE ACCORDING TO APPROVED DRAWINGS. 2017 NEC AND 2016 NFPA-72.

  42. PermitAddition and/or Alterations

    Permit MP-2020-001161 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM IN THE 11TH FLOOR COMMON CORRIDOR AS PER APPROVED PLANS.

  43. PermitElectrical

    Permit 979755 · COMPLETED

    INSTALLATION OF LOW VOLTAGE OF CATEGORY 6 CABLES FOR COMPUTERS FOR 83 LOCATIONS AS PER 2017 NEC (WEST DISTRICT)

  44. PermitElectrical

    Permit 949929 · COMPLETED

    RELOCATE 3 SPEAKER/STROBES AND INSTALL 2 NEW SPEAKER/STROBES AS PER PLANS AND SPECS AND IN ACCORDANCE WITH NFPA 70.

  45. PermitMechanical

    Permit 946087 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR 10TH FLOOR OFFICE SPACE TO INCLUDE VAV BOXES, DUCTWORK AND DIFFUSERS AS PER APPROVED PLANS.

  46. PermitElectrical

    Permit 943383 · COMPLETED

    INSTALL RECEPTACLES, FURN FEEDS, LIGHT FIXTURES AND LIGHTING CONTROLS AS PER PLANS AND SPECS AND IN ACCORDANCE WITH NEC 2008

  47. PermitSuppression

    Permit 943976 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  48. PermitMajor alteration

    Permit 935800 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO TENTH FLOOR OFFICE SPACE IN AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  49. PermitMechanical

    Permit 896979 · COMPLETED

    RELOCATE 17 DIFFUSERS TO COMPLY WITH EZ PERMIT STANDARDS FOR DUCTWORK

  50. PermitAdministrative

    Permit 901918 · COMPLETED

    TCO FOR 5TH FLOOR

  51. PermitElectrical

    Permit 896600 · COMPLETED

    INSTALL LIGHTING AND LIGHTING CONTROLS,RECEPTACLES & BRAMCH WIRING, EXISTING ELETRICAL PANELS 225AMP 120/208V & 400AMP 277/408V FEEDER & METERING ARE TO BE REUSED AS PER 2008 NEC (WEST DISTRICT) INSTALL FIRE ALARM TO EXISTING BUILDING SYSTEM (4-SPEAKERS/STROBE, 1-STROBE) AS PER NFPA72

  52. PermitElectrical

    Permit 876471 · COMPLETED

    PROVIDE AND INSTALL 134 CAT6 PLENUM CABLES @100' AVERAGE.ALL CABLING WILL BE INSTALLED IN J-HOOKS AND ALL PENETRATIONS WILL BE FIRE STOPPED PER 2008 NEC (OFFICE SPACE)

  53. PermitSuppression

    Permit 897300 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRESUBMISSION OF CONSTRUCTION PLANS.

  54. PermitElectrical

    Permit 895602 · COMPLETED

    INSTALL 34- PLENUM RATED, CAT6 COMPUTER COMMUNICATION POINTS- LONGEST RUN APPROX 95'... PER 2008 NEC (OFFICE)

  55. PermitPlumbing

    Permit 895853 · COMPLETED

    INSTALL NEW SANITARY WASTE AND VENT AND HOT AND COLD WATER PIPING FOR NEW SINK AT PANTRY

  56. PermitElectrical

    Permit 881564 · COMPLETED

    FURNISH AND INSTALL 23 SPEAKER/STROBES,27 STROBES,1 NAC,3 DETECTORS AND 3 RELAYS PER NFPA 72

  57. PermitMajor alteration

    Permit 885689 · COMPLETED

    FOR THE LEVEL II ALTERATION TO CREATE A TENANT SPACE ON THE 15TH FLOOR OF A BUILDING. TENANT SPACE FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  58. PermitPlumbing

    Permit 874503 · COMPLETED

    INSTALL NEW SANITARY,WASTE AND VENT HOT AND COLD PIPING FOR NEW SINKS AT PANTRY WELLNESS ROOM.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  59. PermitElectrical

    Permit 874317 · COMPLETED

    FURNISH AND INSTALL NEW PANELS, RECEPTACLES, LIGHTS & SWITCHES AS PER 2008 NEC (WEST DISTRICT)

  60. PermitElectrical

    Permit 873474 · COMPLETED

    INSTALL NEW 50AMP FEEDER FROM PANEL TO NEW TRANSFORMER, 1-208/120VOLT 3PH,100AMP PANEL, 1-30KVE TRANSFORMER, INSTALL LIGHTING, RECEPTACLES, HVAC FEEDERS AS PER 2008 NEC (WEST DISTRICT) ADD ADDITIONAL SPEAKER STROBES AND STROBES AS PER NFPA72

  61. PermitMechanical

    Permit 875126 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR FIFTH FLOOR OFFICE SPACE TO INCLUDE VAV BOXES, DUCTWORK AND DIFFUSERS AS PER APPROVED PLANS.

  62. PermitMechanical

    Permit 873956 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR 12TH FLOOR OFFICE SPACE (SUITE 1230) TO INCLUDE NINE (9) VAV DAMPERS, DUCT AND AIR DEVICES AS PER APPROVED PLANS.

  63. PermitElectrical

    Permit 872815 · COMPLETED

    INSTALL 35- CAT6 PLENUM CABLES, LONGEST RUN 125'. NEW WALL MOUNT RACK TO SUPPORT NEW CABLE. TERMINATE, TEST & LABEL NEW CABLING. 70- NEW PATCH CORDS, GROUND NEW RACK, SUPPORT ALL CABLING... IN ACCORDANCE WITH 2008 NEC (HI-RISE OFFICES)

  64. PermitSuppression

    Permit 874349 · COMPLETED

    RELOCATE 25 HEADS ON 12TH FLOOR. FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  65. PermitPlumbing

    Permit 874006 · COMPLETED

    INSTALL NEW SANITARY, WASTE & VENT * HOT & COLD WATER PIPING FOR NEW SINK & FLOOR DRAIN AT PANTRY THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  66. PermitMajor alteration

    Permit 858286 · COMPLETED

    FOR INTERIOR ALTERATIONS TO EXPAND OFFICE SPACE AT 12TH FLOOR (SUITE 1230), TO INCLUDE NEW INTERIOR PARTITIONS AND INTERIOR FINISHES, AS PER APPROVED PLANS. SEE APP# 706758 FOR ORIGINAL PERMIT

  67. PermitElectrical

    Permit 862392 · COMPLETED

    ADD SPEAKER STROBES AND STROBES TO EXISTING FIRE ALARM SYSTEM AS PER NFPA 72

  68. PermitMechanical

    Permit 865165 · COMPLETED

    HVAC INSTALLATION INCLUDES TWO AIR DAMPERS, DUCTWORK, AIR DEVICES AS PER PLANS

  69. License issue eventHigh Rise initially issued

    License 772731 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  70. PermitElectrical

    Permit 857505 · COMPLETED

    2-NEW PANEL, 1-TRANSFORMER, 18-RECEPTACLES, 2-SWITCH, REWORK LIGHTING AS PER NEC 2008

  71. PermitPlumbing

    Permit 864322 · COMPLETED

    INSTALL SOIL, VENT AND DOMESTIC WATER PIPING FROM CORE OF BUILDING TO NEW PANTRY/BREAK ROOM. INSTALL PANTRY SINK AND FAUCET

  72. PermitAdministrative

    Permit 864141 · COMPLETED

    TCO FOR ENTIRE BUILDING. PARENT PERMIT 551141. SEPARATE CERTIFICATES OF OCCUPANCY OR TEMPORARY CERTIFICATES REQUIRED FOR NEW TENANT FIT-OUTS.

  73. License issue eventRental initially issued

    License 771308 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  74. PermitSuppression

    Permit 859159 · COMPLETED

    RELOCATE 22 EXISTING SPRINKLER HEADS (COMMERCIAL)

  75. PermitElectrical

    Permit 856497 · COMPLETED

    INSTALL 10- REPLACEMENT LIGHTS ON OUTSIDE WALL OF LOADING DOCK AND IN EXTERIOR STAIR WELL

  76. PermitMajor alteration

    Permit 854103 · COMPLETED

    LEVEL II ALTERATION TO PARTIAL 16TH FLOOR AS PER PLANS. ** SEPARATE PERMIT IS REQUIRED FOR M.E.P.S.**

  77. InvestigationEP_ELEC

    Case 609581 · PASSED

    The cited inspection visit was marked passed.

  78. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 606247 · PASSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.

  79. PermitAdministrative

    Permit 837005 · COMPLETED

    AMEND PERMIT A/P 745675 CHANGE IN SCOPE INSTALLATION OF 51 NORMAL AND EMERGENCY LIGHT FIXTURES,4 SWITCHES,6 RECEPTACLES,6 EQUIPMENT BRANCH CIRCUITS,2 DEVICES INCLUDING NEW SUBPANELS,1 TRANSFORMER AND FEEDERS PER 2008 NEC (OFFICE SPACE)MIDDLE ATLANTIC INSPECTION AGENCY

  80. InvestigationEP_ELEC

    Case 600252 · PASSED

    The cited inspection visit was marked passed.

  81. PermitMechanical

    Permit 813158 · COMPLETED

    HVAC INSTALLATION FOR THE EXPANSION SPACE FURNISH ONE VAV BOX & DUCT FOR 2 VAV PER REVISED PLANS

  82. PermitElectrical

    Permit 801298 · COMPLETED

    TENANT FIT OUT LIGHTING AND POWER AND FIRE ALARM PER 2008 NEC AND NFPA 72 (OFFICE SPACE)

  83. ViolationELECTRICAL AGENCY

    Case 609581 · Violation 4489429 · Code 09-1304(3) · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  84. ViolationELECTRICAL INSPECTOR

    Case 609581 · Violation 4489430 · Code 09-1305(3) · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  85. InvestigationEP_ELEC

    Case 609581 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  86. PermitElectrical

    Permit 806773 · COMPLETED

    FURNISH & INSTALL 149 CATEGORY 6 PLENUM CABLES ON THE 15TH FLOORS AS PER NEC 2008 CC DISTRICT

  87. PermitNew construction

    Permit 806666 · COMPLETED

    NEW CONSTRUCTION FIT OUT OF 15TH FLOOR SHELL SPACES (SEE NEW CONSTRUCTION PERMIT 551141) FOR OFFICE SPACES TO INCLUDE ACCESSORY CONFERENCE SPACES INCLUDE THE WESTERN FLOOR PLATE AREA APPROX 3,000 ADDITIONAL AS PER PLANS. BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  88. PermitElectrical

    Permit 810194 · COMPLETED

    INSTALL CELLULAR DAS SYSTEM INCLUSIVE OF 361 INDOOR ANTENNAS,4 GPS ROOF ANTENNAS,18 SIGNAL AMPLIFIERS,25,000FT OF PLENUM RATES INDOOR CELLAR COAX,500FT OF OUTDOOR RATED COAX,6,000FT OF FIBER OPTIC CABLE,3 EQUIPMENT CABINETS AND ASSOCIATED HEAD END CELLULAR CARRIER INTERFACE EQUIPMENT WITH LONGEST RUN OF 100' AS PER 2008 NEC (WEST DISTRICT)

  89. PermitElectrical

    Permit 809925 · COMPLETED

    INSTALL 21 CAT6 PLENUM RATED CABLES WITH LONGEST RUN OF 115' AS PER 2008 NEC (CC DISTRICT)

  90. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 606247 · Violation 4465635 · Code FC-13-915.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  91. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 606247 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  92. PermitElectrical

    Permit 806772 · COMPLETED

    FURNISH & INSTALL 68 CATEGORY 6 PLENUM CABLES ON THE 15TH FLOORS AS PER NEC 2008 CC DISTRICT

  93. PermitElectrical

    Permit 804565 · COMPLETED

    2-NEW PANEL, 1-TRANSFORMER, 1-METER, 2 FAN POWER FEEDS, 9-DEPLEX RECEPTACLES, 10-QUADS, 3-WALL FURNITURE FEEDS, 4-GFI'S, 1-CLOCK OUTLET, 1-FLOOR BOX, 1-EXHAUST FAN, 3-EXITS, 25-LIGHTS, 8-WALL/CEILING MOTION AS PER NEC 2008 CC DISTRICT AND FIRE ALARM AS PER NFPA 72

  94. PermitElectrical

    Permit 804567 · COMPLETED

    F&I FLOOR BOXES, 9-DUPLEX RECEPT, 7-QUAD, 7-RING & STRING, 3-DEDICATED GFI, 1-WATER HEATER, 1-EMON METER, 2-PANELS, 1-CEILING TRANSFORMER, 60-LIGHT, 10-CEIL/WALL MOTION, 2-EXIT, 2-DIMMER, 2-SW AS PER NEC 2008 CC DISTRICT AND FIRE ALARM AS PER NFPA 72

  95. PermitMechanical

    Permit 799637 · COMPLETED

    FURNISH AND INSTALL DUCT, DIFFUSERS & 11 VAV BOXES FOR NEW OFFICE LAYOUT

  96. ViolationBOX-NEEDED AT TERMINATION

    Case 600252 · Violation 4426460 · Code E-1201.1/302 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  97. ViolationPENALTY- NO ELEC PERM INFO

    Case 600252 · Violation 4426459 · Code A-901.13/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  98. ViolationPERME- ALTER ELEC INSTALLATION

    Case 600252 · Violation 4426458 · Code A-301.1/53 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  99. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 600252 · Violation 4426457 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  100. InvestigationEP_ELEC

    Case 600252 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  101. PermitSuppression

    Permit 804986 · COMPLETED

    WE WILL BE RELOCATIONG (16) SPRINKLER HEADS AT IRONSTONE, THE FMC TOWER BUILDING, ON THE 15TH FLOOR.

  102. PermitPlumbing

    Permit 801318 · COMPLETED

    MODIFY SANITARY, VENT AND DOMESTIC WATER PIPING FOR NEW SINK IN PANTRY, CONNECT TO EXISTING PLUMBING.

  103. PermitPlumbing

    Permit 803389 · COMPLETED

    INSTALL ONE SINK,ONE INDIRECT WASTE,CONNECT ONE COFFEE MAKER,CONNECT ONE DISHWASHER,AND CONNECT ONE REFRIGERATOR ICE MAKER (OFFICE SPACE)

  104. PermitAdministrative

    Permit 803573 · COMPLETED

    FOR ALL AREAS ON FLOORS 16 & 17 EXCEPT NEWLY CONSTRUCTED INTER FLOOR STAIR CASE.

  105. PermitSuppression

    Permit 802032 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  106. PermitNew construction

    Permit 796036 · COMPLETED

    NEW CONSTRUCTION FIT OUT OF THE 15TH FLOOR SHELL SPACES (SEE NEW CONSTRUCTION PERMIT 551141) FOR OFFICE SPACE AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK.

  107. PermitNew construction

    Permit 796040 · COMPLETED

    NEW CONSTRUCTION FIT OUT OF THE 15TH FLOOR SHELL SPACES (SEE NEW CONSTRUCTION PERMIT 551141) FOR OFFICE SPACE AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK.

  108. PermitNew construction

    Permit 795390 · COMPLETED

    NEW CONSTRUCTION FIT OUT OF 15TH FLOOR SHELL SPACES (SEE NEW CONSTRUCTION PERMIT 551141) FOR OFFICE SPACES TO INCLUDE ACCESSORY CONFERENCE SPACES AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  109. PermitAdministrative

    Permit 795930 · COMPLETED

    RESIDENTIAL LEVELS 45 & 46. MECHANICAL LEVELS 47,48,49,50.

  110. PermitSuppression

    Permit 795823 · COMPLETED

    RELOCATE (72) EXISTING SPRINKLER HEADS IN ORDER TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES.

  111. PermitElectrical

    Permit 786662 · COMPLETED

    INSTALLATION OF 518 CAT6 AND 48 CAT 6A CABLES ORIGINATING FROM 16TH FLOOR TELECOMMUNICATIONS ROOM INSTALLATION OF 2 EQUIPMENT RACKS AND ASSOCIATED TERMINATION HARDWARE INSTALLATION OF FIBER OPTIC BACKBONE BETWEEN THE TENANT TELECOMMUNICATION ROOM AND THE BLDG FLOOR TELECOMMUNICATION RISER ROOM

  112. PermitElectrical

    Permit 782277 · COMPLETED

    OFFICE FITOUT INCLUDING LIGHTING AND POWER PANELBOARDS, OCCUPANCY SENSORS, DIMMERS, NEW LIGHTING RECPETACLES AND CONNECTIONS TO FURNITURE CUBICLE AS PER 2008 NEC (WEST DISTRICT) INSTALL FIRE ALARM DEVICES AS PER NFPA 72 (PLANS TO FOLLOW)

  113. PermitAdministrative

    Permit 788335 · COMPLETED

    TCO FOR LEVEL 28 THETRE AND AV ROOM, LVL B-1 STORAGE AREAS

  114. PermitAdministrative

    Permit 788358 · COMPLETED

    TCO FOR LEVEL B-1 KITCHEN/RESTAURANT

  115. PermitSuppression

    Permit 787370 · COMPLETED

    RELOCATE (512) EXISTING SPRINKER HEADS. (COMMERCIAL)

  116. PermitMechanical

    Permit 783333 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR 16TH & 17TH FLOOR OFFICE FIT-OUTS IN A NEW HIGH-RISE BUILDING AS PER APPROVED PLANS.

  117. PermitAdministrative

    Permit 783065 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR RESIDENTIAL UNITS 13 & 14 ON FLOORS 30 - 45.

  118. PermitPlumbing

    Permit 782996 · COMPLETED

    PLUMBING FOR 4- COFFEE STATION SINKS. ALL CONNECTIONS INTO EXISTING RISERS.

  119. PermitNew construction

    Permit 774816 · COMPLETED

    NEW CONSTRUCTION FIT OUT OF 16TH AND 17TH FLOOR SHELL SPACES (SEE NEW CONSTRUCTION PERMIT 551141) FOR OFFICE SPACES TO INCLUDE ACCESSORY CONFERENCE SPACES AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  120. PermitSuppression

    Permit 778395 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (RESIDENTIAL)- FOR THE RELOCATION OF RESIDENTIAL SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  121. PermitSuppression

    Permit 777155 · COMPLETED

    FOR THE INSTALLATION OF NEW WET CHEMICAL KITCHEN HOOD FIRE SUPPRESSION SYSTEM AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  122. PermitAdministrative

    Permit 771849 · COMPLETED

    TO AMEND PERMIT# 753512 TO INCLUDE THE INSTALLATION OF FOUR (4) KITCHEN HOODS, AS PER APPROVED PLANS.

  123. PermitElectrical

    Permit 746313 · COMPLETED

    FIT OUT EXISTING SHELL SPACE FOR A NEW RESTAURANT PER DRAWINGS. NEW ELECTRICAL PANELS, TRANSFORMERS, RECEPTACLES, KITCHEN EQUIPMENT POWER, HVAC POWER AND LIGHT FIXTURES. NEW FIRE ALARM DEVICES CONNECTED TO EXISTING BUILDING FIRE ALARM SYSTEM.

  124. PermitElectrical

    Permit 749049 · COMPLETED

    OFFICE FIT OUT WORK INCLUDING TEMP POWER AND LIGHT, AND POWER PANEL BOARDS, OCCUPANCY SENSORS, DIMMERS, NEW LIGHTING, RECEPTACLES, AND CONNECTIONS TO FURNITURE CUBICLE AS PER NEC 2008 AND FIRE ALARM AS PER NFPA 72 WEST DISTRICT. CONSTRUCTION PERMIT AP#743118

  125. PermitElectrical

    Permit 770441 · COMPLETED

    INSTALL 12-TEMPORARY STRING LIGHTS ON FLOOR & 9-TEMPORARY RECEPTACLES ON FLOORS 16 & 17 STARTING USING EXISTING POWER IN BUILDING 03/30/17 TO 9/30/17 AS PER NEC 2008

  126. PermitAdministrative

    Permit 769497 · COMPLETED

    RESIDENTIAL FLOOR 29 AND AMENITIES LEVEL 28 POOL AREA.

  127. PermitDemolition

    Permit 769473 · COMPLETED

    EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  128. PermitMechanical

    Permit 753513 · COMPLETED

    FOR THE INSTALLATION OF AIR-HANDLING UNIT, VAV TERMINAL UNITS, NEW REGISTERS/DIFFUSERS AND ASSOCIATED DUCT WORK, AS PER APPROVED PLANS.

  129. PermitMechanical

    Permit 753512 · COMPLETED

    FOR THE INSTALLATION OF MAKE-UP AND EXHASUT FANS, AS PER APPROVED PLANS. KITCHEN HOODS ARE NOT PART OF THIS APPLICATION.

  130. PermitMechanical

    Permit 763451 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR 14TH FLOOR OFFICE FIT-OUT IN A HIGH-RISE BUILDING TO INCLUDE (39) VAV BOXES, (3) HEAT PUMP A/C UNITS, DUCT & AIR DEVICES AS PER APPROVED PLANS.

  131. PermitSuppression

    Permit 768510 · COMPLETED

    RELOCATE (53) EXISTING SPRINKLER HEADS. (COMMERCIAL)

  132. PermitNew construction

    Permit 751850 · COMPLETED

    FIT OUT OF THE 11TH FLOOR OFFICE SPACE AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ANY M.E.P. AND FIRE SUPPRESSION WORK. FOR ISSUANCE OF CERTIFICATE OF OCCUPANCY.

  133. PermitAdministrative

    Permit 753431 · COMPLETED

    AMEND NEW CONSTRUCTION FIT-OUT PERMIT NUMBER 716194 FOR MODIFICATIONS TO FLOOR LAYOUTS ON 6TH THROUGH 8TH FLOORS AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED.

  134. PermitAdministrative

    Permit 749312 · COMPLETED

    AMEND BUILDING PERMIT #738029 TO INCLUDE ERECTION OF NEW INTERIOR MEZZANINE AND INCREASE IN OCCUPANT LOAD FOR ENTIRE RESTAURANT SPACE AS PER APPROVED PLANS AND BBS VARIANCE NO. 29800.

  135. PermitSuppression

    Permit 759237 · COMPLETED

    INSTALLATION OF NEW SUPPLY LINES AND (210) SPRINKLERS COMPLYING WITH THE NFPA 13 STANDARD FOR 10TH FLOOR OFFICE FIT-OUT WITHIN AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. SEE PERMIT 594547 FOR STANDPIPE RISERS, MAIN SUPPLY AND BACKFLOW ASSEMBLY INSTALLATION.

  136. PermitPlumbing

    Permit 753501 · COMPLETED

    NEW CONSTRUCTION: INTERIOR PLUMBING; RESTAURANT; GROUND FLOOR B1 - THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  137. PermitElectrical

    Permit 749250 · COMPLETED

    FURNISH AND INSTALL 74 CATEGORY 6 PLENUM CABLES AVG CABLE PULL 125 FEET PER 2008 NEC (OFFICE SPACE)

  138. PermitAdministrative

    Permit 747616 · COMPLETED

    FOR THE AMENDMENT OF APPROVED PERMIT #728900 TO DOCUMENT WORK TO BE COMPLETED ON THE 15TH FLOOR LEVEL INSTEAD OF THE 14TH FLOOR LEVEL. PERMIT PREVIOUSLY APPROVED FOR FOR THE FITOUT OF A TENANT SPACE IN A BUILDING. TENANT SPACE FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  139. AppealBuilding standards appeal

    Appeal 29800 · CLOSED · APPROVED

    Related permit 749312 · ON 01/20/2017, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #749312.

  140. PermitAdministrative

    Permit 757269 · COMPLETED

    TCO OR LEVELS 39 TO 44. AMENITIES LEVEL 28 BUSINESS CENTER AND LOBBY. INCLUDES UNITS 3317 & 3318 ON LEVEL 33. AMENITIES LEVEL 28 BUSINESS CENTER ROOMS 2813,2814,2845,2802,2824,2863 AND LOBBY/LIBRARY ROOMS 2803 A,B,C

  141. PermitPlumbing

    Permit 747621 · COMPLETED

    NEW CONSTRUCTION: INTERIOR PLUMBING; 10TH FLOOR OFFICE;SANITARY WASTE; VENT PIPING; DOMESTIC WATER PIPING; WATER HEATER;3 SINKS -THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  142. PermitElectrical

    Permit 732252 · COMPLETED

    CONDUIT RISER WORK ONLY- INSTALL APPORX 3000' OF CONDUIT WITH PULLSTRINGS.

  143. PermitElectrical

    Permit 745675 · COMPLETED

    INSTALL OF NORMAL & EMERGENCY 154-LIGHT FIXTURES,12- SWITCHING), 50-RECEPTACALES, 22-EWUIPMENT, BRANCH ECIRCUTING & DEVICES INCLUDING 2-NEW SUBPANELS, 1-TRANSFORMER & ASSOCIATED FEEDER AS PER NEC 2008 CC DISTRICT

  144. PermitAdministrative

    Permit 755760 · COMPLETED

    TCO

  145. PermitNew construction

    Permit 743118 · COMPLETED

    NEW CONSTRUCTION FIT OUT OF 10TH FLOOR SHELL SPACE (SEE NEW CONSTRUCTION PERMIT 551141) FOR OFFICE SPACES AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. SPECIAL INSPECTION FOR FIREPROOFING COVERED UNDER NEW CONSTRUCTION PERMIT.

  146. PermitZoning/use

    Permit 749314 · COMPLETED

    FOR THE ERECTION OF AN INTERIOR MEZZANINE [NO INCREASE IN GFA OR FAR PER SECTION 14-202(4)(B)(.10)] WITHIN AN EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS SHOWN IN APPLICATION. FOR USE AS AN EXTENSION OF A PREVIOUSLY APPROVED SIT-DOWN RESTAURANT ON THE FIRST FLOOR OF AN EXISTING BUILDING WITH OTHER PREVIOUSLY APPROVED USES. NO SIGNS ON THIS PERMIT.

  147. PermitPlumbing

    Permit 749170 · COMPLETED

    INSTALL ONE PANTRY SINK WITH SOIL, VENT AND DOMESTIC WATER CONNECTING TO BUILDING SUPPLY

  148. PermitMechanical

    Permit 747555 · COMPLETED

    INSTALLATION OF NEW HVAC SYSTEM FOR OFFICE SPACE ON 10TH FLOOR OF A HIGH-RISE BUILDING AS PER APPROVED PLANS.

  149. PermitSuppression

    Permit 748639 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  150. PermitNew construction

    Permit 738029 · COMPLETED

    FIT OUT OF SHELL COMMERCIAL SPACE ON GROUND FLOOR AND LEVEL B1 FOR A RESTAURANT AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. **NO MEZZANINE CONSTRUCTION ON THIS PERMIT, SEPARATE PERMIT REQUIRED** **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  151. PermitAlteration

    Permit 728900 · COMPLETED

    FOR THE FITOUT OF A TENANT SPACE ON THE 14TH FLOOR OF A BUILDING. TENANT SPACE FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  152. PermitAdministrative

    Permit 744915 · COMPLETED

    TCO FOR FLOORS B1 (EXCEPT B103-107, B110, B129, B133) AND FLOORS 30 THROUGH 38 (EXCEPT UNITS 13 AND 14 ON EACH FLOOR AT THE HOIST BAYS AND UNITS 3317 AND 3318).

  153. PermitSuppression

    Permit 732447 · COMPLETED

    INSTALLATION OF NEW PRE-ACTION SPRINKLER SYSTEMS IN ACCORDANCE WITH NFPA 13 ON THE 6TH AND 8TH FLOORS OF AN EXISTING BUILDING AS PER APPROVED PLANS. SYSTEM TO TIE INTO EXISTING SPRINKLER SYSTEM.

  154. PermitAdministrative

    Permit 735788 · COMPLETED

    AMEND PERMIT #551141 TO INCLUDE THE REMOVAL OF THE GLASS SMOKE VESTIBULES ON LEVEL 28, MID AND LOW ELEVATORS AND THE ADDITION OF A SMOKE CONTAINMENT SYSTEM AS PER APPROVED PLANS. SMOKE CONTAINMENT TO BE IN ACCORDANCE WITH SECTION 708.14.1, EXCEPTION 3 OF THE 2009 IBC. AMENDED PERMIT ALSO TO INCLUDE NEW ADDRESS OF 2929 WALNUT STREET INSTEAD OF 2930 CHESTNUT STREET (NO LONGER VALID ADDRESS FOR BUILDING)

  155. PermitElectrical

    Permit 731916 · COMPLETED

    INSTALL 3000-CATEGORY 6 PLENUM RATED CABLES AND AVG CABLE IS ABOUT 175 FEET AS PER 2008 NEC (WEST DISTRICT)

  156. PermitMechanical

    Permit 724311 · COMPLETED

    FOR THE INSTALLATION OF MECHANICAL SYSTEM ON 6TH, 7TH, AND 8TH FLOORS TO INCLUDE NEW VAV UNITS, AIR CONDITIONING UNITS, NEW REGISTERS/DIFFUSERS WITH ASSOCIATED DUCT WORK, AS PER APPROVED PLANS.

  157. PermitPlumbing

    Permit 724315 · COMPLETED

    ALTERATION: INSTALLATION OF SUPPLY AND DWV LINES TO AND FROM LAVATORY SINK FIXTURES ON FLOORS 6 THROUGH 8 IN EXISTING BUILDING. INCLUDING 7-INDIVIDUAL WATER HEATERS PER LAV. THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004.

  158. PermitSuppression

    Permit 732341 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

Where this comes from

Methodology & freshness

This report was assembled Jul 10, 2026, 4:26 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)