Industrial property report

3025 Meetinghouse Rd

Research this property with Analyst →

1 story207,500 sqftI1built 2019

Property at a glanceIndustrial building

6th And Brown LLC

2026 assessment
$26M OPA value, not a listing price
2027 published assessment
$34M Future roll, not the current tax bill
Neighborhood area
Parkwood · Far Northeast Approximate · based on ZIP 19154
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $33,633,600. It is not yet the billed-year tax basis.

$0$25M$50M$34M201820202022202420262027
Property assessmentAssessmentL&I violationPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record47 events · exact dates, newest first
  1. LicenseCompass Group USA, Inc.: Food Establishment, Retail Permanent Location business license marked inactive
  2. InspectionL&I investigation
  3. PermitAddition and/or Alteration
  4. PermitAddition and/or Alteration
  5. LicenseCompass Group USA, Inc.: Food Establishment, Retail Permanent Location business license initially issued
  6. PermitAddition and/or Alteration
  7. PermitAddition and/or Alteration
  8. PermitAddition and/or Alteration
  9. PermitAddition and/or Alterations
  10. InspectionL&I investigation
  11. InspectionL&I investigation
  12. L&I violationSPECIAL INSPECTIONS REQUIRED
  13. InspectionL&I investigation
  14. InspectionL&I investigation
  15. InspectionL&I investigation
  16. L&I violationFDC IMPACT PROTECTION
  17. L&I violationFDC ACCESS
  18. InspectionL&I investigation
  19. PermitAddition and/or Alteration
  20. PermitAlterations
  21. PermitAddition and/or Alterations
  22. PermitAlterations
  23. PermitAddition and/or Alteration
  24. PermitAddition and/or Alteration
  25. PermitSign
  26. PermitAddition and/or Alteration
  27. PermitSigns (Accessory / Non-Accessory)
  28. PermitAddition and/or Alteration
  29. PermitAddition and/or Alterations
  30. PermitNew construction, addition, GFA change
  31. PermitRough-In
  32. PermitAlterations
  33. PermitAddition and/or Alteration
  34. PermitAddition and/or Alteration
  35. PermitChange of Use
  36. PermitSigns (Accessory / Non-Accessory)
  37. PermitSign
  38. PermitZoning/use
  39. PermitSign
  40. PermitSuppression
  41. PermitPlumbing
  42. L&I violationSIGNAGE-MAJOR BLDG REQUIRED
  43. PermitElectrical
  44. PermitPlumbing
  45. PermitMechanical
  46. PermitNew construction
  47. PermitZoning/use

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $33,633,600. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 884293100
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Industrial property

Industrial building, recorded in the City's industrial category. The public record and owner trail follow.

What it is
Industrial building Ind Warehouse Masonry+Oth
Owner
6th And Brown LLC
$ / sq ft
$162 above the $70 median for 3,574 industrial parcels citywide
Interior area
207,500 sqft
Lot size
704,655 sqft
Stories
1
Built
2019
Zoning
I1

Recorded owner

Who's behind it

6th And Brown LLC · corporate / LLC owner

• Owns 2 properties across Philadelphia under this name, assessed at $43M combined
• Tax bills mail to 885 Spring View Dr, Southampton PA, 18966 — outside Philadelphia

Block context

3000 block of Meeting House Rd. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 3099 Meetinghouse Rd  ·  3000 Meetinghouse Rd

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
Compass Group USA, Inc.Inactive

Food Establishment, Retail Permanent Location · Initial issue date May 7, 2024 · Terminal license date Jul 5, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 47 dated rows
  1. License terminal eventCompass Group USA, Inc.: Food Establishment, Retail Permanent Location business license marked inactive

    License 950872 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  2. InvestigationL&I investigation

    Case CF-2021-093355 · PASSED

    The cited inspection visit was marked passed.

  3. PermitAddition and/or Alteration

    Permit EP-2024-009958 · Completed

    Install new 120/208 power for new Automation Vehicle Inspection Equipment all low voltage installed by others . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  4. PermitAddition and/or Alteration

    Permit CP-2024-004018 · Completed

    FOR THE INSTALLATION OF NEW EQUIPMENTS FOR AN AUTOMATIC VEHICLE INSPECTION. WORK TO BE PERFORMED PER APPROVED PLANS.**SEPARATE PERMIT REQUIRED FOR ALL OTHER WORK**IELECTRICAL WORK INCLUDED IN THE PERMIT**F FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.**

  5. License issue eventCompass Group USA, Inc.: Food Establishment, Retail Permanent Location business license initially issued

    License 950872 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  6. PermitAddition and/or Alteration

    Permit CP-2024-000195 · Completed

    FOR THE RELOCATION AND RECONFIGURATION OF EXISTING STAIR CROSSOVERS TO ACCOMMODATE AN EXISTING CONVEYOR SYSTEM. ** WORK TO BE COMPLETED PER PLAN ** IF FIELD CONDITIONS VARY, PLEASE CONTACT DESIGN ENGIEER PRIOR TO THE COMPLETION OF WORK**

  7. PermitAddition and/or Alteration

    Permit EP-2023-011432 · Completed

    3- 200 amp feeders, 480 volt, 3 phase-3 wire, to 3 automated conveyor control panels 2- 30 amp branch circuits, 480 volt, 3 phase-3 wire, to 2 compressors wiring run in conduits. Includes relocation of existing 120 volt, 30 amp twist lock power drops and installing 1 new 120 volt, 30 amp twist lock power drop. ALL WORK IS TOM BE DONE ACCORDING TO APPROVED DRAWINGS -2017 NEC.

  8. PermitAddition and/or Alteration

    Permit CP-2023-006614 · Completed

    FOR LEVEL 2 ALTERATIONS TO REPLACE EXISTING CONVEYOR EQUIPMENT WITH UPGRADED NEW CONVEYOR EQUIPMENT AS PER PLANS.

  9. PermitAddition and/or Alterations

    Permit MP-2023-005493 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2023-006614

  10. InvestigationL&I investigation

    Case CF-2023-032346 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  11. InvestigationL&I investigation

    Case CF-2023-032346 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  12. ViolationSPECIAL INSPECTIONS REQUIRED

    Case CF-2023-032346 · Violation VI-2023-024535 · Code A-304.2/2 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  13. InvestigationL&I investigation

    Case CF-2023-032346 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  14. InvestigationL&I investigation

    Case CF-2021-093355 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  15. InvestigationL&I investigation

    Case CF-2021-093355 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. ViolationFDC IMPACT PROTECTION

    Case CF-2021-093355 · Violation VI-2021-067877 · Code FC-13-912.3.3 · CLOSED

    Resolution: CLOSED - STOP PROCESSING City marked the record closed; open the case for the closing reason.

  17. ViolationFDC ACCESS

    Case CF-2021-093355 · Violation VI-2021-067878 · Code FC-13-912.3 · CLOSED

    Resolution: CLOSED - STOP PROCESSING City marked the record closed; open the case for the closing reason.

  18. InvestigationL&I investigation

    Case CF-2021-093355 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  19. PermitAddition and/or Alteration

    Permit EP-2020-011721 · Completed

    Provide fire alarm equipment and wiring for the addition of 2 dry type sprinkler system in new canopy as per 2016 NFPA 72.

  20. PermitAlterations

    Permit PP-2021-001012 · Expired

    SITE WORK AS SHOWN IN PLANS (PWD TRACKING NUMBER FY18-PROP-4971-01) TO INCLUDE NEW RCP STORMWATER PIPING TO CONNECT TO EXISTING STORMWATER MANAGEMENT BMP (WITHIN PROPERTY LINES) THIS WORK PREVIOUSLY APPLIED FOR UNDER PP-2020-012054; HOWEVER, THAT PERMIT WAS ISSUED WITHOUT PLANS. PLANS FOR THIS STORMWATER CONNECTION ATTACHED.

  21. PermitAddition and/or Alterations

    Permit FP-2020-001760 · Completed

    FOR THE EXTENSION OF EXISTING NFPA 13 SPRINKLER SYSTEM TO PROTECT ADDITIONAL SPACE ON OFFICE SPACE AS PER APPROVED PLAN. NO WORK ON EXISTING RISER, FIRE PUMP AND BACK-FLOW PREVENTOR

  22. PermitAlterations

    Permit PP-2020-012054 · Completed

    FOR THE CONSTRUCTION OF ONE (1) NEW CANOPY ATTACHED TO EXISTING WAREHOUSE/DISTRIBUTION CENTER AND SITE WORK TO INCLUDE PAVING FOR TWO HUNDRED AND THREE (203) SURFACE PARKING SPACES INCLUDING SEVEN (7) ADA PARKING SPACES, EIGHTY-FOUR (84) ACCESSORY PARKING SPACES INSIDE PARTIAL FIRST FLOOR WITH EIGHT (8) OFF-STREET LOADING SPACES AND FORTY-EIGHT (48) OFF-STREET VAN LOADING SPACES UNDER THE CANOPY TWENTY (20) ACCESSORY BICYCLE PARKING SPACES, PER SUBMITTED PLANS. **NO SIGNS ON THIS PERMIT** (3) ELECTRICAL WORK: CONDUITS/BOXES AND LIGHT FIXTURES AS SHOWN; NEW WIRING WITHIN CANOPY (4) PLUMBING: UNDERGROUND WORK AS SHOWN IN SITE PLANS (PWD TRACKING NUMBER FY18-PROP-4971-01) TO INCLUDE: - NEW RCP STORMWATER PIPING TO CONNECT TO EXISTING STORMWATER MANAGEMENT BMP (WITHIN PROPERTY LINES)

  23. PermitAddition and/or Alteration

    Permit EP-2020-009557 · Completed

    FOR THE CONSTRUCTION OF ONE (1) NEW CANOPY ATTACHED TO EXISTING WAREHOUSE/DISTRIBUTION CENTER AND SITE WORK TO INCLUDE PAVING FOR TWO HUNDRED AND THREE (203) SURFACE PARKING SPACES INCLUDING SEVEN (7) ADA PARKING SPACES, EIGHTY-FOUR (84) ACCESSORY PARKING SPACES INSIDE PARTIAL FIRST FLOOR WITH EIGHT (8) OFF-STREET LOADING SPACES AND FORTY-EIGHT (48) OFF-STREET VAN LOADING SPACES UNDER THE CANOPY TWENTY (20) ACCESSORY BICYCLE PARKING SPACES, PER SUBMITTED PLANS. **NO SIGNS ON THIS PERMIT** (3) ELECTRICAL WORK: CONDUITS/BOXES AND LIGHT FIXTURES AS SHOWN; NEW WIRING WITHIN CANOPY (4) PLUMBING: UNDERGROUND WORK AS SHOWN IN SITE PLANS (PWD TRACKING NUMBER FY18-PROP-4971-01) TO INCLUDE: - NEW RCP STORMWATER PIPING TO CONNECT TO EXISTING STORMWATER MANAGEMENT BMP (WITHIN PROPERTY LINES)

  24. PermitAddition and/or Alteration

    Permit CP-2020-006439 · Completed

    INSTALLATION OF PRE-MANUFACTURED STORAGE RACKING SYSTEM WITHIN A PREVIOUSLY APPROVED WAREHOUSE STRUCTURE AS PER APPROVED PLANS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK** AMENDMENT APPROVED 1/6/21 AMEND PERMIT CP-2020-006439 TO INCLUDE STAIR PLANS AND DETAILS.

  25. PermitSign

    Permit GP-2020-009995 · Completed

    For the erection of two (2) accessory, statically illuminated wall signs, and eleven (11) accessory, non-illuminated wall signs, onto a detached single-story structure used as a warehouse, as per plans; see ZP-2020-008126 for zoning/use approval.

  26. PermitAddition and/or Alteration

    Permit EP-2020-010090 · Completed

    Install 174 CAT6 plenum cables, Install 66 wireless access points, install (6) 12 strand fiber cables as per 2017 nec

  27. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-008126 · Completed

    FOR ERECTION OF FOUR (4) FLAT WALL SIGNS AND DIRECTIONAL SIGNS WITHOUT LOGO. SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLANS.

  28. PermitAddition and/or Alteration

    Permit CP-2020-005727 · Expired

    FOR THE CONSTRUCTION OF ONE (1) NEW CANOPY ATTACHED TO EXISTING WAREHOUSE/DISTRIBUTION CENTER AND SITE WORK TO INCLUDE PAVING FOR TWO HUNDRED AND THREE (203) SURFACE PARKING SPACES INCLUDING SEVEN (7) ADA PARKING SPACES, EIGHTY-FOUR (84) ACCESSORY PARKING SPACES INSIDE PARTIAL FIRST FLOOR WITH EIGHT (8) OFF-STREET LOADING SPACES AND FORTY-EIGHT (48) OFF-STREET VAN LOADING SPACES UNDER THE CANOPY TWENTY (20) ACCESSORY BICYCLE PARKING SPACES, PER SUBMITTED PLANS. **NO SIGNS ON THIS PERMIT** AMENDMENT APPROVED ON 4/5/2021 FOR THE AMENDMENT TO BUILDING PERMIT CP-2020-005727 TO INCLUDE PROPOSED PREFABRICATED SMOKER'S SHELTER, PER SUBMITTED PLANS AND MANIFACTURER'S SPECIFICATIONS. (3) ELECTRICAL WORK: CONDUITS/BOXES AND LIGHT FIXTURES AS SHOWN; NEW WIRING WITHIN CANOPY (4) PLUMBING: UNDERGROUND WORK AS SHOWN IN SITE PLANS (PWD TRACKING NUMBER FY18-PROP-4971-01) TO INCLUDE: - NEW RCP STORMWATER PIPING TO CONNECT TO EXISTING STORMWATER MANAGEMENT BMP (WITHIN PROPERTY LINES)

  29. PermitAddition and/or Alterations

    Permit MP-2020-001397 · Completed

    For the installation of a mechanical/HVAC system (including all ductwork, registers, diffusers, appliances, and fuel gas piping) throughout a new single-story detached structure to be used as Groups A-3/B/S-1 (warehouse w/accessory offices and employee amenities), as per plans; see CP-2020-001784 for new construction fit-out permit; Systems Commissioning required - compliance checklist, preliminary commissioning report, and building O&M documents to be provided to inspector prior to final inspection.

  30. PermitNew construction, addition, GFA change

    Permit ZP-2020-001356 · Issued

    FOR THE ERECTION OF AN ADDITION TO THE EXISTING DETACHED BUILDING (SIZE AND LOCATION AS SHOWN ON PLANS)

  31. PermitRough-In

    Permit FP-2020-001763 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  32. PermitAlterations

    Permit PP-2020-003489 · Completed

    Tenant finish, warehouse with offices and restroom. Other equipment includes - catch basin, drinking fountains, floor sink, and foot baths.

  33. PermitAddition and/or Alteration

    Permit EP-2020-006562 · Completed

    2000A MDP, 200A GENERATOR TAP BOX, PANELBOARDS, TRANSFORMERS, UPS, LIGHTING INVERTERS, FEEDERS, LIGHTING, LIGHTING CONTROLS, RECEPTACLES, DOCK CONTROLLERS, HVAC POWER WIRING, FIRE ALARM, RACEWAYS ONLY FOR TELECOM AND SECURITY .All work to be done according to engineer sealed drawings. 2017 NEC and 2016 NFPA-72.

  34. PermitAddition and/or Alteration

    Permit CP-2020-001784 · Completed

    FOR LEVEL III ALTERATIONS OF WAREHOUSE BUILDING CONSTRUCTED UNDER BUILDING PERMIT 919506. BUILDING TO BE FULLY STRINKLERED WITH NFPA 13 THROUGHOUT. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION.

  35. PermitChange of Use

    Permit ZP-2020-003488 · Completed

    Wholesale, Distribution, and Storage - Warehouse.

  36. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-003607 · Issued

    FOR THE REFACE OF ONE (1) WALL SIGN AND ONE (1) FREESTANDING SIGN. SIGN AND LOCATION AS SHOWN ON APPROVED PLANS. TO DOCUMENT TWO (2) DIRECTIONAL SIGNS.

  37. PermitSign

    Permit GP-2020-004833 · Completed

    Install new wall sign 48.65" x 40" Reface freestanding sign (documentation only)(NO BUILDING PERMIT REQUIRED FOR REFACING OF THIS FREE STANDING SIGN)

  38. PermitZoning/use

    Permit 972375 · COMPLETED

    FOR THE ERECTION OF ONE WALL SIGN AND ONE FREESTANDING SIGN. SIZE AND LOCATION AS SHOWN ON APPROVED PLANS. TO DOCUMENT TWO DIRECTIONAL SIGNS. SIGNS ACCESSORY TO LIMITED INDUSTRIAL USE.

  39. PermitSign

    Permit 972376 · COMPLETED

    FOR THE ERECTION OF ONE WALL SIGN AND THREE FREESTANDING SIGNS. ALL WORK TO BE DONE IN ACCORDANCE WITH APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL WORK.

  40. PermitSuppression

    Permit 945996 · COMPLETED

    FOR THE INSTALLATION OF NFPA 13 SYSTEM FOR A BUILDING FOR LIMITED INDUSTRIAL USE, FIRE SUPPRESSION SYSTEM SERVICED BY EIGHT INCH FIRE SERVICE LINE WITH A BACKFLOW PREVENTER ASSEMBLY AND A FIRE PUMP. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH A NFPA 13 STANDARD.

  41. PermitPlumbing

    Permit 940913 · COMPLETED

    INSTALL 4 10"RD, STUB 2 6" SAN FUTURE, 1 4" FD. INSTALLATION WILL COMPLY WITH THE 2004 PHILA PLUMBING CODE. (EAST DIST)

  42. ViolationSIGNAGE-MAJOR BLDG REQUIRED

    Case 919506 · Violation 4946789 · Code A-1001.7/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  43. PermitElectrical

    Permit 942057 · COMPLETED

    INSTALL (1500 KVA)PAD MOUNTED TRANSFORMER, (1)2000 AMP 480 VOLT PANEL, (1) 200 AMP 480 VOLT PANEL, (1)30 AMP 208 VOLT PANEL, (1)125HP FIRE PUMP, (1) 5KW EUH, (2) EXHAUST FAN, (1)10HP CAMBRIDGE UNIT, (37)LIGHT FIXTURE, (48)EMERGENCY/EXIT FIXTURE, (2)LIGHT SWITCH, (7)SITE LIGHT, (7)RECEPTACLE, (33)FIRE ALARM DEVICE, (1)300AMP TEMPORARY SERVICE AS PER DRAWINGS.AS PER NEC 2008 AS PER NFPA 72

  44. PermitPlumbing

    Permit 942104 · COMPLETED

    NEW CONSTRUCTION: EXTERIOR PLUMBING; (1) STORY DETACHED WAREHOUSE STRUCTURE; BUILDING PERMIT IS A CORE AND SHELL ONLY PERMIT. SEPARATE PERMIT REQUIRED FOR FINAL FIT OUT AND CERTIFICATE OF OCCUPANCY;TWO 6" SANITARY DRAINS INSTALL ONE 3" DOMESTIC WATER SERVICE

  45. PermitMechanical

    Permit 937977 · COMPLETED

    FOR THE INSTALLATION OF A MECHANICAL SYSTEM AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL AND PLUMBING WORK.

  46. PermitNew construction

    Permit 919506 · COMPLETED

    FOR THE ERECTION OF A ONE (1) STORY DETACHED WAREHOUSE STRUCTURE. THIS IS A CORE AND SHELL ONLY PERMIT. SEPARATE PERMIT REQUIRED FOR FINAL FIT OUT AND CERTIFICATE OF OCCUPANCY. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  47. PermitZoning/use

    Permit 897831 · COMPLETED

    FOR THE ERECTION OF ONE(1) DETACHED STRUCTURE(NTE 60'HIGH); FOR THE CREATION OF TWO HUNDRED AND FOURTY-FIVE(245) ACCESSORY PARKING SPACES INCLUDING WITH SEVEN(7)ACCESSIBLE SPACES INCLUDING WITH ONE(1) VAN ACCESSIBLE SPACE; FIFTY(50) LOADING SPACES AND FOURT-SEVEN(47) OFF-STREET LOADING DOCK AND TWENTY-TWO(22) BICYCLE SPACES FOR A LIMITED INDUSTRIAL USE. SIZE AND LOCATION AS SHOWN IN THE APPLICATION.

Where this comes from

Methodology & freshness

This report was assembled Jul 25, 2026, 10:03 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)