Commercial property report

3310 S 20th St

1 story8,415 sqftICMXbuilt 1944

Property at a glanceCommercial

Renaissance Estate Owners Association

2026 assessment
$1.3M OPA value, not a listing price
2027 published assessment
$1.4M Future roll, not the current tax bill
Neighborhood area
Girard Estate · South Philadelphia Approximate · based on ZIP 19145
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $1,431,900. It is not yet the billed-year tax basis.

$0$1.0M$2.0M$1.4M20202022202420262027
Property assessmentAssessmentL&I violationPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record44 events · exact dates, newest first
  1. L&I violationOCCUPANT LOAD SIGN
  2. L&I violationFDC SIGNAGE REQUIRED
  3. L&I violationFDC ACCESS
  4. L&I violationPERIODIC TESTING
  5. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  6. InspectionL&I investigation
  7. InspectionL&I investigation
  8. InspectionL&I investigation
  9. L&I violationWORKMANLIKE- BUILDING CODE
  10. L&I violationOCCUPIED W/O FINAL APPROVAL
  11. InspectionL&I investigation
  12. L&I violationCOMPL CONCEAL- BLDG PERM WORK
  13. InspectionL&I investigation
  14. L&I violationCOMPL CONCEAL- PLUMB PERM WORK
  15. InspectionL&I investigation
  16. CertificationSprinkler Certification
  17. PermitNew Construction or Additions
  18. InspectionL&I investigation
  19. PermitNew Construction or Additions
  20. PermitNew Construction or Additions
  21. PermitNew Construction or Additions
  22. PermitNew Construction or Additions
  23. PermitNew Construction or Additions
  24. PermitNew Construction or Additions
  25. PermitNew Construction or Additions
  26. PermitNew Construction or Additions
  27. PermitNew Construction or Additions
  28. InspectionL&I investigation
  29. InspectionL&I investigation
  30. PermitNew Construction
  31. PermitNew Construction
  32. PermitNew Construction
  33. PermitNew Construction
  34. PermitNew Construction
  35. PermitNew Construction
  36. PermitNew Construction
  37. PermitNew Construction
  38. PermitNew Construction
  39. PermitNew Construction
  40. PermitNew Construction
  41. PermitNew Construction
  42. PermitNew Construction
  43. PermitNew Construction
  44. PermitNew Construction

Verify the public record

$18,259/year estimated property tax

2026 taxable assessment $1,304,400 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,431,900. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 882250701
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

9 open violations

What it is
Commercial Str/Off 1 Sty Masonry
Owner
Renaissance Estate Owners Association
$ / sq ft
$170 above the $151 median for 7,668 commercial parcels citywide
Interior area
8,415 sqft
Lot size
9,373 sqft
Stories
1
Built
1944
Zoning
ICMX

Recorded owner

Who's behind it

Renaissance Estate Owners Association · corporate / LLC owner

• Tax bills mail to 3310 S 20th St, Philadelphia PA, 19145

Block context

3300 block of S 20th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 3316 S 20th St  ·  3320 S 20th St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 10, 2026.

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 44 dated rows
  1. ViolationOCCUPANT LOAD SIGN

    Case CF-2026-065969 · Violation VI-2026-043189 · Code F-1104.30 · OPEN

  2. ViolationFDC SIGNAGE REQUIRED

    Case CF-2026-069676 · Violation VI-2026-043219 · Code F-912.5 · OPEN

  3. ViolationFDC ACCESS

    Case CF-2026-069676 · Violation VI-2026-043220 · Code F-912.4 · OPEN

  4. ViolationPERIODIC TESTING

    Case CF-2026-069676 · Violation VI-2026-043221 · Code F-901.6.4 · OPEN

  5. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2026-069676 · Violation VI-2026-043222 · Code F-903.5 · OPEN

  6. InvestigationL&I investigation

    Case CF-2026-065969 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  7. InvestigationL&I investigation

    Case CF-2026-069676 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  8. InvestigationL&I investigation

    Case CF-2026-065969 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  9. ViolationWORKMANLIKE- BUILDING CODE

    Case CF-2026-002921 · Violation VI-2026-016216 · Code A-104.1/1 · OPEN

  10. ViolationOCCUPIED W/O FINAL APPROVAL

    Case CF-2026-002921 · Violation VI-2026-016212 · Code A-402.5 · OPEN

  11. InvestigationL&I investigation

    Case CF-2026-002921 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  12. ViolationCOMPL CONCEAL- BLDG PERM WORK

    Case CF-2026-002914 · Violation VI-2026-001969 · Code A-402.1/1 · OPEN

  13. InvestigationL&I investigation

    Case CF-2026-002914 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  14. ViolationCOMPL CONCEAL- PLUMB PERM WORK

    Case CF-2026-002698 · Violation VI-2026-001680 · Code A-402.1/4 · OPEN

  15. InvestigationL&I investigation

    Case CF-2026-002698 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. CertificationSprinkler Certification

    Certification BC-2024-014857 · Certified

    Expires 2025-05-15

  17. PermitNew Construction or Additions

    Permit PP-2021-007609 · Completed

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  18. InvestigationL&I investigation

    Case CF-2021-050018 · PASSED

    The cited inspection visit was marked passed.

  19. PermitNew Construction or Additions

    Permit PP-2021-007618 · Completed

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  20. PermitNew Construction or Additions

    Permit PP-2021-007581 · Issued

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  21. PermitNew Construction or Additions

    Permit PP-2021-007580 · Completed

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  22. PermitNew Construction or Additions

    Permit PP-2021-007613 · Issued

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  23. PermitNew Construction or Additions

    Permit PP-2021-007601 · Completed

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  24. PermitNew Construction or Additions

    Permit PP-2021-007588 · Expired

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  25. PermitNew Construction or Additions

    Permit PP-2021-007604 · Completed

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  26. PermitNew Construction or Additions

    Permit PP-2021-007575 · Expired

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  27. PermitNew Construction or Additions

    Permit PP-2021-007577 · Expired

    For Interior Plumbing Work to Include Installing VENTS, DRAINS, and SERVICE LINES throughout for [4] WATER CLOSETS, [4] LAVATORIES, [3] TUBS/SHOWERS, [1] KITCHEN SINK, [1] WASHER, [1] WATER HEATER, and [1] HOSE BIBB as per 2018 Philadelphia Plumbing Code.

  28. InvestigationL&I investigation

    Case CF-2021-050018 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  29. InvestigationL&I investigation

    Case CF-2021-050018 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  30. PermitNew Construction

    Permit EP-2020-004963 · Completed

    INSTALL NEW 200AMP SERVICE AND WIRE ENTIRE BUILDING WITH CIRCUITS FOR RECEPTS,SWITCHES,LIGHTS,FIXTURES,SMOKES AND CO DETECTORS AS PER 2014 NEC (SOUTH DISTRICT)

  31. PermitNew Construction

    Permit MP-2020-001742 · Completed

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per EZ Standard

  32. PermitNew Construction

    Permit MP-2020-001750 · Completed

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD)

  33. PermitNew Construction

    Permit MP-2020-001748 · Completed

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per EZ Standard.

  34. PermitNew Construction

    Permit MP-2020-001745 · Issued

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per EZ Standard

  35. PermitNew Construction

    Permit MP-2020-001741 · Issued

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per EZ Standard.

  36. PermitNew Construction

    Permit MP-2020-001746 · Completed

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per ez standards

  37. PermitNew Construction

    Permit MP-2020-001744 · Completed

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per EZ Standard

  38. PermitNew Construction

    Permit MP-2020-001749 · Issued

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) AS PER EZ STANDARD

  39. PermitNew Construction

    Permit MP-2020-001740 · Issued

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per EZ Standard

  40. PermitNew Construction

    Permit MP-2020-001747 · Issued

    Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD) as per EZ Standard.

  41. PermitNew Construction

    Permit MP-2020-001231 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of new ductwork, registers/grilles/diffusers, and warm-air appliances as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans.*No rooftop units* Install (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD)

  42. PermitNew Construction

    Permit MP-2020-001234 · Expired

    For Mechanical work in a New Two Family Dwelling to include Installing (2) 96% Eff. 40,000 BTU Gas furnaces Exhausted via direct vent to the exterior. install ductwork, grilles, [20]registers and diffusers, installing (2) 2 Ton 13 seer A/C condensers (SFD).

  43. PermitNew Construction

    Permit 1045745 · Issued

    install (2) gas furnances with ductwork

  44. PermitNew Construction

    Permit 1045747 · Expired

    INSTALL (2) gas furnaces with ductwork

Where this comes from

Methodology & freshness

This report was assembled Jul 19, 2026, 6:20 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)