Industrial property report

339 E Lehigh Ave

7 stories · 251,657 sqft · ICMX · built 2023

Property at a glanceIndustrial

339-41 Lehigh Eat LLC

2026 assessment
$31M OPA value, not a listing price
2027 published assessment
$31M Future roll, not the current tax bill
Neighborhood area
Fishtown · East Kensington Approximate · based on ZIP 19125
Street view of 339 E Lehigh Ave
From the street · imagery © Google
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $31,457,100. It is not yet the billed-year tax basis.

$0$25M$50M$31M2010201320162019202220252027
Property assessmentAssessmentL&I violationAppealPermitInspectionCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record52 events · exact dates, newest first
  1. InspectionL&I investigation
  2. CertificationFire Alarm Certification
  3. InspectionL&I investigation
  4. L&I violationFIRE EXTINGUISHERS REQUIRED
  5. L&I violationINSPECTION, TESTING & MAINTENANCE
  6. InspectionL&I investigation
  7. CertificationFire Alarm Certification
  8. CertificationFire Alarm Certification
  9. PermitAddition and/or Alteration
  10. PermitAddition and/or Alteration
  11. PermitAlterations
  12. CertificationSprinkler Certification
  13. PermitAlterations
  14. PermitNew Construction
  15. PermitNew Construction
  16. PermitAmend for conversion
  17. PermitNew Construction
  18. PermitTank Install/Removal
  19. PermitRough-In
  20. PermitDemolition
  21. PermitAlterations
  22. PermitDemolition
  23. PermitElectrical
  24. PermitNew Construction
  25. PermitNew Construction
  26. PermitZoning/use
  27. PermitZoning/use
  28. PermitZoning
  29. AppealZoning board appeal
  30. InspectionBP_BLDG
  31. InspectionBP_BLDG
  32. L&I violationPERMB - CLEAR/DIG/DISTURB SITE
  33. L&I violationPERMB- CONST FOUNDATION
  34. L&I violationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)
  35. L&I violationPENALTY- NO BLDG PERM INFO
  36. InspectionBP_BLDG
  37. InspectionBC INSP (likely: building-code inspection)
  38. PermitPlumbing
  39. InspectionBP_BLDG
  40. PermitElectrical
  41. PermitPlumbing
  42. L&I violationNON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)
  43. L&I violationCAL LO (Commercial Activity License required)
  44. InspectionBC INSP (likely: building-code inspection)
  45. PermitUse
  46. PermitAlteration
  47. PermitAlteration
  48. InspectionBP_BLDG
  49. L&I violationPERMB- ALTER REPAIR INT PART (Building permit required for interior alteration or repair)
  50. L&I violationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)
  51. L&I violationPERM Z- NEW USE
  52. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

Verify the public record

$129,586/year estimated property tax

2026 taxable assessment $9,257,430 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $31,457,100. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 884346903
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $9,257,430 of $30,858,100 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Industrial property

Industrial, recorded in the City's industrial category. The public record and owner trail follow.

What it is
Industrial Ind Bldg Mini Whse Mason
Owner
339-41 Lehigh Eat LLC
$ / sq ft
$125 above the $70 median for 3,574 industrial parcels citywide
Interior area
251,657 sqft
Lot size
42,909 sqft
Stories
7
Built
2023
Zoning
ICMX

Recorded owner

Who's behind it

339-41 Lehigh Eat LLC · corporate / LLC owner

• Tax bills mail to 2727 N Central Ave, Phoenix AZ, 85004 — outside Philadelphia

Block context

300 block of E Lehigh Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 337 E Lehigh Ave  ·  335 E Lehigh Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 23, 2026.

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 52 dated rows
  1. InvestigationL&I investigation

    Case CF-2025-126496 · PASSED

    The cited inspection visit was marked passed.

  2. CertificationFire Alarm Certification

    Certification BC-2026-003859 · Certified

    Expires 2027-02-10

  3. InvestigationL&I investigation

    Case CF-2025-126496 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  4. ViolationFIRE EXTINGUISHERS REQUIRED

    Case CF-2025-126496 · Violation VI-2025-091062 · Code F-906.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  5. ViolationINSPECTION, TESTING & MAINTENANCE

    Case CF-2025-126496 · Violation VI-2025-091063 · Code F-901.6 · COMPLIED

    Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.

  6. InvestigationL&I investigation

    Case CF-2025-126496 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  7. CertificationFire Alarm Certification

    Certification BC-2025-011324 · Certified

    Expires 2026-04-14

  8. CertificationFire Alarm Certification

    Certification BC-2024-014788 · Certified

    Expires 2025-05-02

  9. PermitAddition and/or Alteration

    Permit EP-2021-010247 · Completed

    Connect owners air compression from existing power and circuits to make the final connection to U-Haul sign. Power & circuits were provided by others under base permit job as per 2017 NEC. Amendment: We need to change the electrical inspection agency to United Inspection Agency

  10. PermitAddition and/or Alteration

    Permit EP-2021-010068 · Completed

    Inspect the owner's security equipment and wiring as directed by the building inspector to ensure all wiring meets current code & NEC 2017 standards. Equipment includes but is not limited to: 11 alarm panels & expanders, 16 keypads, 105 dual-tone sirens, 45 door contacts, 36 motion detectors, 80 PA speakers, 2 door master stations, 10 power supplies, 50 cameras, 51 video door stations & 2 master stations. Amendment: We need to change the electrical inspection agency to: United Inspection Agency Inc. 716 N. Bethlehem Pike Suite 300 Lower Gwynedd, PA 19002 Bureau Veritas doesn't have any licensed inspectors available for the city.

  11. PermitAlterations

    Permit PP-2021-013751 · Completed

    INSTALL 2 FLOOR DRAINS, 5 HOT WATER HEATERS, 5 LAVATORIES, 20 ROOF DRAINS, 1 SUMP PUMP, 5 WATER CLOSETS AND 8 MOP SINKS ACCORDING TO THE 2018 PPC.

  12. CertificationSprinkler Certification

    Certification BC-2021-003435 · Certified

    Expires 2022-07-26

  13. PermitAlterations

    Permit PP-2021-009646 · Completed

    Install 8 inch curb trap FAI

  14. PermitNew Construction

    Permit 1030672 · Completed

    INSTALL A 1500 KVA TRANSFORMER, 1600 AMP SERVICE, FIRE PUMP SERVICE, 250 KW GENERATOR AND TRANSFER SWITCH FOR ELEVATOR STAND BY POWER. PROVIDE POWER FOR THE ELEVATORS, MECHANICAL AND HVAC EQUIPMENT. PROVIDE WIRING THROUGHOUT FOR THE LIGHTS, SWITCHES, CONTROLS AND RECEPTACLES. PROVIDE EMERGENCY LIGHTING THROUGHOUT. AS PER THE 2017 NEC 7 2016 NFPA-72.

  15. PermitNew Construction

    Permit 1045423 · Completed

    FOR THE FURNISHING AND INSTALLATION OF (31) SPLIT SYSTEMS, (6) GAS FIRED HEATERS, (1) RADIANT GAS HEATER, AND (17) EXHAUST FANS DUCTWORK GRD'S LOUVERS/DAMPERS, REFRIGERANT & CONDENSATE PIPING,FELX/COLLARS/SPIRAL PIPE AS PER PLANS (78) REGISTER/DIFFUSERS IN A SELF STORAGE AND TRUCK RENTAL FACILITY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. **IMC 2018**

  16. PermitAmend for conversion

    Permit 1044251 · Completed

    FOR THE AMENDMENT OF BUILDING PERMIT 962371, ISSUED FOR FOUNDATION AND NEW CONSTRUCTION OF A SEVEN STORY BUILDING(NOT HIGH RISE-HIGHEST OCCUPIED FLOOR LEVEL IS 72'-0" ABOVE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS) FOR USE AS SELF STORAGE AND TRUCK RENTAL FACILITY. PERMIT TO BE APPROVED FOR THE ASSEMBLY AND DISASSEMBLY OF ASSOCIATED TOWER CRANE TO BE LOCATED ENTIRELY WITHIN PROPERTY LINES, NO ENCROACHMENT OF PUBLIC FOOTWAYS PROPOSED AS PER DESIGN ENGINEERED PLANS AND SPECIFICATIONS. IF FIELD CONDITIONS VARY CONTACT STRUCTURAL ENGINEER PRIOR TO THE START OF ANY WORK.

  17. PermitNew Construction

    Permit 1023201 · Completed

    INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM DESIGNED PER NFPA 13 STANDARDS WITH AN ELECTRIC FIRE PUMP, STANDPIPES AND WET FIRE SPRINKLERS THROUGHOUT AS PER PLANS. ALL SERVED BY A NEW 6 INCH FIRE SERVICE LINE.

  18. PermitTank Install/Removal

    Permit 1041819 · Completed

    REMOVE AND DISPOSE OF ONE (1) 1,000-GALLON UNDERGROUND STORAGE TANK (UST) AND TWO (2) 500-GALLON UNDERGROUND STORAGE TANKS.

  19. PermitRough-In

    Permit 1030956-RI · Completed

    ROUGH IN UNDERGROUND SLAB AND ABOVE GROUND WATER ANAD SANITARY 5 WC 5 LAV, 1 FD, 7 MOPS SINK INSIDE THE BUILDING

  20. PermitDemolition

    Permit 1015793 · COMPLETED

    COMPLETE DEMOLITION OF AN EXISTING DETACHED TWO-STORY, MASONRY AND WOOD OFFICE BUILDING BY MECHANICAL METHODS. ALL PERMITTED DEMOLITION ACTIVITY TO BE IN ACCORDANCE WITH APPROVED SITE SAFETY DEMOLITION PLAN & SUCH PLAN TO BE MAINTAINED ON SITE AT ALL TIMES IN ACCORDANCE WITH PHILADELPHIA ADMINISTRATIVE CODE. PARTIAL SIDEWALK CLOSURE REQUIRED AS REFLECTED ON APPROVED SITE PLAN AND IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE STREET CLOSURE PERMIT REQUIRED PRIOR TO START OF WORK. ANY DEVIATION WILL REQUIRE AN AMENDED BUILDING PERMIT.

  21. PermitAlterations

    Permit 1018612 · Completed

    SEAL 5" LATERAL-PA1#20192342943-REMOVE HOUSE TRAP AND HERMETICALLY SEALING THE LATERAL BY A CAP OR PLUG PER SECTION P-606.1 OF THE PHILADELPHIA PLUMBING CODE 2004 - "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  22. PermitDemolition

    Permit 1006556 · COMPLETED

    REMOVE ONE (1) 1000 GALLON UNDERGROUND STORAGE TANK. THE REMOVAL MUST COMPLY WITH THE REGULATIONS OF THE PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION (PADEP). REMOVE AND DISPOSE OF ONE

  23. PermitElectrical

    Permit 998452 · COMPLETED

    INSTALL NEW 100AMP TEMPORARY SERVICE FOR TRAILER ON CONSTRUCTION SITE FOR NEW UHAUL BUILDING ONLY AS PER 2014 NEC (EAST DISTRICT)

  24. PermitNew Construction

    Permit 982223 · Completed

    200 AMP TEMPORARY ELECTRICAL POWER FOR NEW CONSTRUCTION OF UHAUL BUILDING AS PER 2008 NEC (NORTH DIST)

  25. PermitNew Construction

    Permit 962371 · Completed

    FOR THE ERECTION OF A SEVEN (7) STORY BUILDING FOR USE AS A SELF STORAGE AND TRUCK RENTAL FACILITY, ENSURE HIGHEST OCCUPIED FLOOR LEVEL IS 72'-0" ABOVE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS. BUILDING IS SPRINKLERED IN ACCORDANCE WITH NFPA 13 STANDARD, WITH STANDPIPES LOCATED IN EXIT STAIRWAYS PER NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR MECHANCIAL, ELECTRICAL, PLUMBING AND FIRE SUPRESSION WORK.***AMENDED PERMIT REQUIRED FOR SPECIAL INSPECTIONS***A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 21 FEET OF THE BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE 2009 IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO THE START OF ANY WORK

  26. PermitZoning/use

    Permit 959880 · COMPLETED

    FOR THE COMPLETE DEMOLITION OF ALL EXISTING STRUCTURES ON THE LOTS; FOR THE CONSTRUCTION OF A DETACHED BUILDING FOR USE AS A SELF-STORAGE FACILITY WITH ACCESSORY TRUCK RENTALS (PERSONAL VEHICLE SALES AND RENTALS) WITH ACCESSORY PARKING SPACES (5 TOTAL), ACCESSORY LOADING SPACES (2 TOTAL), STREET TREES (2 TOTAL).

  27. PermitZoning/use

    Permit 963833 · COMPLETED

    FOR THE ERECTION OF SEVEN (7) ACCESSORY WALL SIGNS, SIZE AND LOCATION AS SHOWN ON APPROVED PLANS UNDER AP#959880).

  28. PermitZoning

    Permit 912657 · COMPLETED

    RELOCATION OF LOT LINES TO CREATE 1 LOT FROM 2 EXISTING LOTS FOR DEMO OF ALL EXISTING STRUCTURES ON THE LOT

  29. AppealZoning board appeal

    Appeal 35538 · OPEN · Granted

    Related permit 912657 · PERMIT FOR RELOCATION OF LOT LINES TO CREATE ONE (1) LOT FROM TWO (2) EXISTING LOTS (339-41 E. LEHIGH AVENUE AND 301 E. GURNEY STREET); FOR THE DEMOLITION OF ALL EXISTING STRUCTURES ON THE LOTS; FOR THE CONSTRUCTION OF A DETACHED BUILDING F

  30. InvestigationBP_BLDG

    Case 639545 · CLOSED

    City marked the record closed; open the case for the closing reason.

  31. InvestigationBP_BLDG

    Case 639545 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  32. ViolationPERMB - CLEAR/DIG/DISTURB SITE

    Case 639545 · Violation 4758155 · Code A-301.1/77 · CLOSED

    City marked the record closed; open the case for the closing reason.

  33. ViolationPERMB- CONST FOUNDATION

    Case 639545 · Violation 4758154 · Code A-301.1/15 · CLOSED

    City marked the record closed; open the case for the closing reason.

  34. ViolationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)

    Case 639545 · Violation 4758156 · Code A-504.1/3 · CLOSED

    City marked the record closed; open the case for the closing reason.

  35. ViolationPENALTY- NO BLDG PERM INFO

    Case 639545 · Violation 4758157 · Code A-901.13/1 · CLOSED

    City marked the record closed; open the case for the closing reason.

  36. InvestigationBP_BLDG

    Case 639545 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  37. InvestigationBC INSP (likely: building-code inspection)

    Case 250716 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  38. PermitPlumbing

    Permit 307897 · COMPLETED

    REPLACE CURB TRAP AND FRESH AIR INLET

  39. InvestigationBP_BLDG

    Case 249254 · PASSED

    The cited inspection visit was marked passed.

  40. PermitElectrical

    Permit 302299 · COMPLETED

    REPLACE (6) RECEPTACLES AND (4) LIGHTING FIXTURES AS PER 2008 NEC (EAST DIST)

  41. PermitPlumbing

    Permit 300700 · COMPLETED

    INSTALL VANITY AND TOILET WITH ATTENDANT COPPER WATER SUPPLY LINES WITH VALUES

  42. ViolationNON-REGULATED LACKS PERMIT (The cited activity or use lacked a required permit)

    Case 250716 · Violation 1811749 · Code 14-1704/10 · COMPLIED

    The title alone does not identify the missing permit or prove the present use remains unauthorized. City marked this violation complied with; check the resolution date and live case for what was accepted.

  43. ViolationCAL LO (Commercial Activity License required)

    Case 250716 · Violation 1811748 · Code 19-2602.1/1 · COMPLIED

    Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city. City marked this violation complied with; check the resolution date and live case for what was accepted.

  44. InvestigationBC INSP (likely: building-code inspection)

    Case 250716 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  45. PermitUse

    Permit 299453 · COMPLETED

    LEAGLIZE THE USE OF AUTO TAG AGENCY AND NOTARY PUBLIC TO AN EXISTING COMMERCIAL PROPERTY.

  46. PermitAlteration

    Permit 299646 · COMPLETED

    REPLACE WATER DAMAGED DRY WALL REPLACE COUNTRE TOPS REPLACE INTERIOR DOOR TO COMPLY VIOLATION 249254

  47. PermitAlteration

    Permit 299528 · COMPLETED

    INSTALL 2 FRONT WINDOWS, ALUMINUM AND GLASS IN EXISTING OPENINGS(COMMERCIAL)SEE HANSEN CASE 249254

  48. InvestigationBP_BLDG

    Case 249254 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  49. ViolationPERMB- ALTER REPAIR INT PART (Building permit required for interior alteration or repair)

    Case 249254 · Violation 1799330 · Code A-301.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  50. ViolationSWO- CONSTR W/O BLDG PERMIT (Stop-work order for construction without a building permit)

    Case 249254 · Violation 1799334 · Code A-504.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  51. ViolationPERM Z- NEW USE

    Case 249254 · Violation 1799333 · Code A-301.1/65 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  52. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 249254 · Violation 1799331 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 9:53 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)