Apartment building report

3737 Chestnut St

25 stories300,000 sqftCMX4built 2014

Property at a glanceApartment building

Cpi Krp 3737 Chestnut Owner LLC

2026 assessment
$86M OPA value, not a listing price
2027 published assessment
$66M Future roll, not the current tax bill
Neighborhood area
University City · West Powelton Approximate · based on ZIP 19104
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $66,293,600. It is not yet the billed-year tax basis.

$0$50M$100M$66M201320162019202220252027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record77 events · exact dates, newest first
  1. CertificationEmergency and Standby Power Systems Certification
  2. CertificationFire Alarm Certification
  3. PermitSigns (Accessory / Non-Accessory)
  4. PermitAddition and/or Alteration
  5. PermitNew Construction or Additions
  6. PermitAddition and/or Alteration
  7. PermitAddition and/or Alteration
  8. PermitChange of Use
  9. CertificationFire Alarm Certification
  10. CertificationSprinkler Certification
  11. CertificationSprinkler Certification
  12. InspectionL&I investigation
  13. InspectionL&I investigation
  14. InspectionL&I investigation
  15. L&I violationFACADES
  16. L&I violationADMINISTRATION GENERAL
  17. L&I violationPORTABLE FIRE EXTINGUISHERS
  18. L&I violationCERTIFICATION
  19. L&I violationBUILDING SERVICES & SYSTEMS F-601
  20. L&I violationDOOR SWING
  21. L&I violationDOORS, GATES, & TURNSTILES
  22. L&I violationFDC SIGNAGE REQUIRED
  23. L&I violationFIRE RESISTANCE RATED CONSTRUCTION
  24. InspectionL&I investigation
  25. InspectionL&I investigation
  26. PermitChange of Use
  27. InspectionCI INSP
  28. InspectionCI INSP
  29. L&I violationPERM Z- NEW USE
  30. InspectionCI INSP
  31. InspectionCI INSP
  32. L&I violationEMERGENCY DRILL RECORD CONTENT
  33. L&I violationFIRE ALARM TESTED/CERTIFIED
  34. L&I violationFIRE SUPPRESSION CERTIFICATION
  35. L&I violationFIRE SAFETY/EVACUATION PLAN
  36. L&I violationSHELTER-IN-PLACE PLAN CONTENT
  37. InspectionCI INSP
  38. LicenseCPI/KRP 3737 Chestnut Owner, LLC (Korman Residential at 3737 Chestnut): Rental landlord or residential registration initially issued
  39. LicenseCPI/KRP 3737 Chestnut Owner, LLC (Korman Residential at 3737 Chestnut): High Rise L&I license filing initially issued
  40. PermitElectrical
  41. PermitSign
  42. PermitZoning/use
  43. AppealZoning board appeal
  44. InspectionBP_BLDG
  45. PermitSuppression
  46. L&I violationPERMP- ALTER/REPAIR/REPL PLUMB
  47. L&I violationPERMB- INSTALL FIRE SUPP SYS
  48. InspectionBP_BLDG
  49. InspectionBP_BLDG
  50. InspectionBP_BLDG
  51. PermitElectrical
  52. PermitElectrical
  53. PermitPlumbing
  54. L&I violationPERMP- ALTER/REPAIR/REPL PLUMB
  55. L&I violationPERMB- INSTALL FIRE SUPP SYS
  56. InspectionBP_BLDG
  57. PermitMechanical
  58. PermitElectrical
  59. PermitSign
  60. PermitNew construction
  61. PermitElectrical
  62. PermitSuppression
  63. PermitPlumbing
  64. PermitElectrical
  65. PermitPlumbing
  66. PermitZoning/use
  67. PermitMechanical
  68. PermitMajor alteration
  69. PermitUse
  70. PermitMechanical
  71. PermitAddition and/or Alteration
  72. PermitAdministrative
  73. PermitAdministrative
  74. PermitAdministrative
  75. PermitAdministrative
  76. PermitElectrical
  77. CertificationFacade Report

Verify the public record

$1,202,151/year estimated property tax

2026 taxable assessment $85,880,200 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $66,293,600. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881116125
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartment building, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartment building Apts 100+ Units Masonry
Owner
Cpi Krp 3737 Chestnut Owner LLC
$ / sq ft
$221 above the $147 median for 2,826 apartments parcels citywide
Corridor
36th Street and vicinity city commercial corridor
Licensed units
276 active rental license
Interior area
300,000 sqft
Lot size
16,062 sqft
Stories
25
Built
2014
Zoning
CMX4

Recorded owner

Who's behind it

Cpi Krp 3737 Chestnut Owner LLC · corporate / LLC owner

• Tax bills mail to 410 Lancaster Avenue, Haverford PA, 19041 — outside Philadelphia
• Holds an active rental license for this address

Block context

3700 block of Chestnut St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 3721 Chestnut St  ·  3717l-19 Chestnut St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 29, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

CPI/KRP 3737 Chestnut Owner, LLC (Korman Residential at 3737 Chestnut)Active

Rental · Initial issue date Jan 10, 2019 · Filed expiration Jan 9, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 77 dated rows
  1. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-015693 · Certified

    Expires 2026-06-10

  2. CertificationFire Alarm Certification

    Certification BC-2025-004657 · Certified

    Expires 2025-03-27

  3. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2023-009410 · Issued

    FOR THE ERECTION OF TWO (2) ACCESSORY STATICALLY ILLUMINATED WALL SIGNS. SIZES AND LOCATIONS AS SHOWN ON APPLICATION/PLANS.

  4. PermitAddition and/or Alteration

    Permit EP-2023-006935 · Completed

    Installing 12 Cat-5 low voltage data cables inside Tropical Smoothie Cafe as per 2017 nec

  5. PermitNew Construction or Additions

    Permit PP-2023-004567 · Completed

    INSTALL 2 HUB DRAINS, 2 FLOOR DRAIN, 4 FLOOR SINKS, 1 PREP SINK, 3-COMPARTMENT SINK, 1 GREASE INTERCEPTOR, 2 HAND SINKS, 1 MOP SINK, 1 LAVATORY, 1 WATER CLOSET, 1 HOT WATER HEATER AND 1 ICE MAKER ACCORDING TO THE 2018 PPC AND PER PLANS. **AMEND** THERE IS A SMALL REVISION TO THE GREASETRAP LOCATION AND THE TYPE OF WATER HEATER.

  6. PermitAddition and/or Alteration

    Permit EP-2023-003687 · Completed

    1) Bid is based on drawings dated 8.29.2023 supplied by TK studio 2) All sign seal electrical drawling’s 3) Furnish and Install all required power for outlets based on E110 4) Furnish wiring and switching 5) Install Lighting supplied by others based on E150 6) Furnish and Install wiring for Refrigeration equipment based on E110 7) Furnish and Install 120/208 electrical panel “RPB” 8) Furnish and Install light switching based on E120 9) Provide necessary inspections for the projects 10) “Ring and string” for low data/communications wiring by others as per drawing E120 11) Demo existing as required per drawings As per 2017 nec

  7. PermitAddition and/or Alteration

    Permit CP-2023-000203 · Completed

    FOR THE LEVEL II ALTERATION TO CREATE A PREPARED FOOD SHOP WITHIN THE EXISTING TENANT SPACE AS PER APPROVED PLANS. BUILDING IS FULLY SPRINKLERED. SEPATATE PERMITS REQUIRED FOR MEP AND FP WORK. Amendment to include Bulkhead Detail.

  8. PermitChange of Use

    Permit ZP-2023-002665 · Issued

    Eating and Drinking Establishments - Prepared Food Shop

  9. CertificationFire Alarm Certification

    Certification BC-2023-008511 · Certified

    Expires 2024-03-28

  10. CertificationSprinkler Certification

    Certification BC-2023-008500 · Certified

    Expires 2024-03-23

  11. CertificationSprinkler Certification

    Certification BC-2022-005904 · Certified

    Expires 2023-04-06

  12. InvestigationL&I investigation

    Case CF-2021-110971 · PASSED

    The cited inspection visit was marked passed.

  13. InvestigationL&I investigation

    Case CF-2021-110971 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  14. InvestigationL&I investigation

    Case CF-2021-110971 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  15. ViolationFACADES

    Case CF-2021-110971 · Violation VI-2021-080078 · Code PM15-315.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  16. ViolationADMINISTRATION GENERAL

    Case CF-2021-110971 · Violation VI-2021-079979 · Code FC-13-101 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  17. ViolationPORTABLE FIRE EXTINGUISHERS

    Case CF-2021-110971 · Violation VI-2021-079980 · Code FC-13-906 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  18. ViolationCERTIFICATION

    Case CF-2021-110971 · Violation VI-2021-079981 · Code FC-13-915 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  19. ViolationBUILDING SERVICES & SYSTEMS F-601

    Case CF-2021-110971 · Violation VI-2021-079982 · Code FC-13-601 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  20. ViolationDOOR SWING

    Case CF-2021-110971 · Violation VI-2021-079991 · Code FC-13-1008.2.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  21. ViolationDOORS, GATES, & TURNSTILES

    Case CF-2021-110971 · Violation VI-2021-080054 · Code FC-13-1008 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. ViolationFDC SIGNAGE REQUIRED

    Case CF-2021-110971 · Violation VI-2021-080055 · Code FC-13-912.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  23. ViolationFIRE RESISTANCE RATED CONSTRUCTION

    Case CF-2021-110971 · Violation VI-2021-080079 · Code FC-13-701 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  24. InvestigationL&I investigation

    Case CF-2021-110971 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  25. InvestigationL&I investigation

    Case 720874 · PASSED

    The cited inspection visit was marked passed.

  26. PermitChange of Use

    Permit ZP-2020-004733 · Issued

    Eating and Drinking Establishments - Sit-Down Restaurant; Eating and Drinking Establishments - Take-Out Restaurant

  27. InvestigationCI INSP

    Case 716889 · PASSED

    The cited inspection visit was marked passed.

  28. InvestigationCI INSP

    Case 720874 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  29. ViolationPERM Z- NEW USE

    Case 720874 · Violation 211984756 · Code A-301.1/65 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  30. InvestigationCI INSP

    Case 716889 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  31. InvestigationCI INSP

    Case 720874 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  32. ViolationEMERGENCY DRILL RECORD CONTENT

    Case 716889 · Violation 5284540 · Code FC-13-405 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  33. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 716889 · Violation 5284541 · Code FC-13-915.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  34. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 716889 · Violation 5284542 · Code FC-13-915.1A · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  35. ViolationFIRE SAFETY/EVACUATION PLAN

    Case 716889 · Violation 5284538 · Code FC-13-404.2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  36. ViolationSHELTER-IN-PLACE PLAN CONTENT

    Case 716889 · Violation 5284539 · Code FC-13-404331 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  37. InvestigationCI INSP

    Case 716889 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  38. License issue eventCPI/KRP 3737 Chestnut Owner, LLC (Korman Residential at 3737 Chestnut): Rental landlord or residential registration initially issued

    License 799158 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  39. License issue eventCPI/KRP 3737 Chestnut Owner, LLC (Korman Residential at 3737 Chestnut): High Rise L&I license filing initially issued

    License 754244 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  40. PermitElectrical

    Permit 760908 · COMPLETED

    PROVIDE ONE 120V 20AMP BRANCH CIRCUIT AND TIME CLOCK FOR EXTERIOR SIGNAGE, AS PER 2008 NEC.

  41. PermitSign

    Permit 743737 · COMPLETED

    FOR THE INSTALLATION OF TWO (2) SETS (13 1/4" X 46 1/16") OF STATICALLY ILLUM. FLAT WALL (CHANNEL LETTERS) SIGNS AS PER PLANS,SIGNS ACCESSORY TO A BUSINESS AND PROFESSIONAL OFFICE ON THE SECOND FLOOR OF AN EXISTING STRUCTURE,

  42. PermitZoning/use

    Permit 725194 · COMPLETED

    TIAA OCCUPIES ENTIRE SECOND FLOOR. SOUTH ELEVATION -(1) SET OF ILLUM. CHANNEL LETTERS TO WALL 13 1/4"X46 1/6"= 4.2 SQ FT ABOVE 1ST FL. WEST ELEVATION `1) SET OF ILLUM CHANNEL LETTERS TO WALL 13 1/4" X 46 1/6"= 4.2 SQ FT ABOVE FIRST ST FL ACCESSORY TO BUSINESS AND PROFESSIONAL OFFICE USE ON THE SECOND FLOOR IN AN EXISTING BLDG. WITH ALL OTHER USES AS PREVIOUSLY APPROVED

  43. AppealZoning board appeal

    Appeal 29089 · OPEN · Granted

    Related permit 725194 · PERMIT FOR THE INSTALLATION OF (2) ILLUMINATED CHANNEL LETTER FLAT WALL SIGNS. ACCESSORY TO A PREVIOUSLY APPROVED USE AS FINANCIAL SERVICES ON THE SECOND FLOOR. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS.

  44. InvestigationBP_BLDG

    Case 557686 · PASSED

    The cited inspection visit was marked passed.

  45. PermitSuppression

    Permit 726124 · COMPLETED

    RELOCATE 20 SPRINKLER HEADS 2ND FLR

  46. ViolationPERMP- ALTER/REPAIR/REPL PLUMB

    Case 557686 · Violation 4099737 · Code A-301.1/55 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  47. ViolationPERMB- INSTALL FIRE SUPP SYS

    Case 557686 · Violation 4099736 · Code A-301.1/27 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  48. InvestigationBP_BLDG

    Case 557686 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  49. InvestigationBP_BLDG

    Case 549230 · PASSED

    The cited inspection visit was marked passed.

  50. InvestigationBP_BLDG

    Case 549230 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  51. PermitElectrical

    Permit 711703 · COMPLETED

    FURNISH AND INSTALL 52 CAT 6 PLENUM RATED CABLE AND 1 RG COAX CABLE, LONGEST CABLE RUN APPROX 200' LONG AS PER 2008 NEC (CC DISTRICT)

  52. PermitElectrical

    Permit 711275 · COMPLETED

    INSTALL 4-STROBE, 3-SPEAKER/STROBE & ASSOCIATED CABLING, EXISTING DEVICE WILL BE RELOCATED AS PER NFPA 72 WEST DISTRICT

  53. PermitPlumbing

    Permit 714874 · COMPLETED

    NEW ROUGH-IN TO INCLUDE SANITARY WASTE AND VENT AND DOMESTIC HOT AND COLD WATER PIPING FOR NEW SINK AT BREAK ROOM AND WATER CLOSET AND LAV AT ADA TOILET ROOM. NO OTHER FIXTURES ON THIS PERMIT

  54. ViolationPERMP- ALTER/REPAIR/REPL PLUMB

    Case 549230 · Violation 4086890 · Code A-301.1/55 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  55. ViolationPERMB- INSTALL FIRE SUPP SYS

    Case 549230 · Violation 4086889 · Code A-301.1/27 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  56. InvestigationBP_BLDG

    Case 549230 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  57. PermitMechanical

    Permit 710911 · COMPLETED

    INSTALLATION OF HVAC SYSTEM AS PER PLAN.

  58. PermitElectrical

    Permit 704689 · COMPLETED

    INSTALL 69-LIGHT FIXTURES, 19-SWITCHES/OCC SENSORS, 11-EXIT/EMERGENCY DEVICES, 34-RECEPTACLES, 1-WORKSTATION FEED, 1-EXHAUST FAN, 1-MINI SPLIT & ASSOCIATED BRANCH CIRCUITING FROM EXISTING PANEL AS PER NEC 2008 WEST DISTRICT

  59. PermitSign

    Permit 706008 · COMPLETED

    FOR THE INSTALLATION OF ONE FLAT WALL SIGN

  60. PermitNew construction

    Permit 696022 · COMPLETED

    FIT OUT FOR NEW FINIANCIAL SERVICES SPACE ON PARTIAL SECOND FLOOR AS PER PLAN. **SEPARATE PERMITS REQUIRED FOR ELECTRICAL, PLUMBING AND MECHANICAL WORK.**

  61. PermitElectrical

    Permit 691354 · COMPLETED

    INSTALL 2-STROBES, RELOCATE 1-SPEAKER/STROBE, 1-PULL STATION & PROVIDE ASSOCIATED CABLING ON EXISTING BLDG SYSTEM AS PER NFPA 72 WEST DISTRICT

  62. PermitSuppression

    Permit 689418 · COMPLETED

    FOR ALTERATIONS TO EXIST AUTOMATIC SPRINKLER SYSTEM W. EXISTING FIRE SERVICE, BACKFLOW PREVENTION (BFP) & FIRE PUMP ASSEMBLIES TO SERVE PREVIOUSLY APPROVED COMMERCIAL SPACE WITHIN EXIST. MIXED-USE MULTI-FAMILY DWELLING. AUTOMATIC SPRINKLER SYSTEM INSTALL PER NFPA 13.

  63. PermitPlumbing

    Permit 679691 · COMPLETED

    ALTERATION: INTERIOR PLUMBING FOR A 1ST FLOOR RESTAURANT, IN A HIGH RISE BUILDING.THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE, 2004.

  64. PermitElectrical

    Permit 686216 · COMPLETED

    INSTALL LIGHT FIXTURES, SWITCHES, RECECPTACLES (2) BATHROOM EXHAUST FAN, EXIT AND EMERGENCY LIGHTS, (1)HOT WATER HEATER OUTLET. THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  65. PermitPlumbing

    Permit 693042 · COMPLETED

    INSTALL 3/4" RPZ BACKFLOW PREVENTOR TO SUB OFF MAIN BACKFLOW

  66. PermitZoning/use

    Permit 682222 · COMPLETED

    FOR THE ERECTION OF ONE(1) FLATWALL SIGN FOR A SIT-DOWN RESTAURANT AT SPACE # 2 AT FIRST FLOOR IN THE SAME BUILDING WITH ALL OTHER USES AS PREVIOUSLY APPROVED.

  67. PermitMechanical

    Permit 681166 · COMPLETED

    FOR ALTERATION TO THE EXISTING HVAC SYSTEM AS PER PLANS.

  68. PermitMajor alteration

    Permit 666033 · COMPLETED

    FOR INTIAL FITOUT OF PREVIOUSLY APPROVED VACANT TENANT SPACE TO CREATE SIT-DOWN RESTAURANT WITHIN MIXED-USE HIGH-RISE MULTI-FAMILY BUILDING TO INCLUDE INSTALLATION OF STRUCTURAL STEEL FRAMING & STAIR INSTALLATION FOR INTERIOR MEZZANINE LEVEL, ERECTION OF PARTITIONS FOR CORRIDOR, KITCHEN & TOILET ROOM SPACES & FINISH WORK; SPACE TO BE FULLY SPRINKLERED. SEPARATE PERMIT REQ'D FOR MECH., ELEC., PLUMB., & FIRESUPP WORK.

  69. PermitUse

    Permit 658501 · COMPLETED

    FOR A SIT DWON RESTUARANT AS A COFFEE SHOP AT SPACE #2

  70. PermitMechanical

    Permit 652091 · COMPLETED

    INSTALL (1) 4 TON 1600CFM WATER SOURCE HEAT PUMP AND (1) 2.5 TON WATER SOURCE HEAT PUMP IN TENANTS SPACE ** EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION OF NON LOAD-BEARING PARTITION WALLS AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  71. PermitAddition and/or Alteration

    Permit 637860 · Expired

    INTERIOR ALTERATIONS TO CREATE A VACANT TENANT SPACE #1 WITH AN ADA RESTROOM. SEPARATE PERMIT REQUIRED FOR FIT-OUT AND CERTIFICATE OF OCCUPANCY.

  72. PermitAdministrative

    Permit 638680 · COMPLETED

    TCO FOR FLOOR 19-22 ALSO TO INCLUDE GROUND FLOOR TO 18TH FLOOR AND COMMUNITY GATHERING/DAYCARE SPACE AS PREVIOUSLY APPROVED

  73. PermitAdministrative

    Permit 636133 · COMPLETED

    TCO FOR COMMUNITY GATHERING AND DAYCARE

  74. PermitAdministrative

    Permit 631087 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR FLOORS 14 TO 18, THIS TCO TO INCLUDE FLOORS PREVIOUS APPROVED. (GROUND FLOOR TO 12TH)

  75. PermitAdministrative

    Permit 623370 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR THE GROUND FLOOR LEVEL TO THE (12TH) FLOOR. TCO DOES NOT INCLUDE ANY RETAIL SPACES.

  76. PermitElectrical

    Permit 603549 · COMPLETED

    FURNISH & INSTALL 1328 WORK AREA OUTLETS (WAQS) CONSISTING OF TOTAL 731 CATEGORY 6 CABLES & 930 RG-6 COAXIAL CABLES & 276 MICRODUCTS (1937 TOTAL CABLES)APT BLDG AS PER 2008 WEST DISTRICT

  77. CertificationFacade Report

    Certification BC-2022-010751 · Safe with Repair

    Expires 2018-01-21

Where this comes from

Methodology & freshness

This report was assembled Jul 30, 2026, 6:22 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)