Apartment building report

4146-48 Parkside Ave

5 stories17,150 sqftRM1built 2022

Property at a glanceApartments

4148 Parkside LP

2026 assessment
$2.6M OPA value, not a listing price
2027 published assessment
$3.5M Future roll, not the current tax bill
Neighborhood area
University City · West Powelton Approximate · based on ZIP 19104
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $3,525,800. It is not yet the billed-year tax basis.

$0$2.5M$5.0M$3.5M20192021202320252027
Property assessmentAssessmentL&I violationPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record19 events · exact dates, newest first
  1. L&I violationRUBBISH & GARBAGE
  2. InspectionL&I investigation
  3. License4148 parkside lp: Rental landlord or residential registration initially issued
  4. PermitAddition and/or Alterations
  5. PermitNew Construction
  6. InspectionL&I investigation
  7. PermitNew Construction or Additions
  8. InspectionL&I investigation
  9. InspectionL&I investigation
  10. PermitNew Construction or Additions
  11. PermitNew Construction
  12. InspectionL&I investigation
  13. InspectionL&I investigation
  14. InspectionL&I investigation
  15. InspectionL&I investigation
  16. PermitNew Construction
  17. PermitNew Construction
  18. PermitNew construction, addition, GFA change
  19. PermitFoundation

Verify the public record

$3,623/year estimated property tax

2026 taxable assessment $258,820 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $3,525,800. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881000775
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $258,820 of $2,597,200 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartments, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartments Vacant Land Reside < Acre
Owner
4148 Parkside LP
$ / sq ft
$206 above the $147 median for 2,826 apartments parcels citywide
Licensed units
28 active rental license
Interior area
17,150 sqft
Lot size
5,460 sqft
Stories
5
Built
2022
Zoning
RM1

Recorded owner

Who's behind it

4148 Parkside LP · corporate / LLC owner

• Tax bills mail to 1218 Green St, Philadelphia PA, 19123
• Holds an active rental license for this address

Block context

4100 block of Parkside Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 4142-44 Parkside Ave  ·  4150-52 Parkside Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 25, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

4148 parkside lpActive

Rental · Initial issue date Feb 14, 2023 · Filed expiration Feb 13, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 19 dated rows
  1. ViolationRUBBISH & GARBAGE

    Case CF-2025-013268 · Violation VI-2025-010455 · Code PM15-308.1 · SVN ISSUED

    Resolution: SVN ISSUED

  2. InvestigationL&I investigation

    Case CF-2025-013268 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  3. License issue event4148 parkside lp: Rental landlord or residential registration initially issued

    License 916690 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  4. PermitAddition and/or Alterations

    Permit MP-2022-004886 · Completed

    FOR THE INSTALLATION OF AN HVAC SYSTEM THROUGHOUT A FIVE (5) STORY MULTI-FAMILY DWELLING TO INCLUDE NEW APPLIANCES, GRILLES / REGISTERS / DIFFUSERS, AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2020-005326 FOR ASSOCIATED BUILDING PERMIT.

  5. PermitNew Construction

    Permit EP-2022-002903 · Completed

    Installation all new wiring,1200A service, generator, all em/exit lighting ,wiring of all units, Wp outlets installed at juliet balconies, all 110V interconnected smoke alarms ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  6. InvestigationL&I investigation

    Case CF-2022-012285 · PASSED

    The cited inspection visit was marked passed.

  7. PermitNew Construction or Additions

    Permit PP-2022-005174 · Completed

    installation of plumbing system for 28 family dwellings

  8. InvestigationL&I investigation

    Case CF-2022-012285 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  9. InvestigationL&I investigation

    Case CF-2022-012285 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  10. PermitNew Construction or Additions

    Permit PP-2022-006448 · Completed

    Supply and install new combined domestic & fire line Supply and install new 2” water service Supply new 2” meter (Installed By PWD) Supply and install (1) new 2” fire service main to building Supply and install new 6” sewer line main to curb Supply and install new 6” curb traps Supply and install new 4” fresh air inlets Supply and install new 4” sanitary & storm lines curb to building

  11. PermitNew Construction

    Permit FP-2022-001006 · Completed

    COMBINED AUTOMATIC SPRINKLER & CLASS I MANUAL WET STANDPIPE SYSTEMS WITH TWO (2) INCH FIRE SERVICE LINE & 2 1/2-INCH BACKFLOW PREVENTION (BFP) ASSEMBLY TO SERVE PREVIOUSLY APPROVED MULTI-FAMILY DWELLING. AUTOMATIC SPRINKLER SYSTEM & STANDPIPE SYSTME INSTALLATION PER NFPA 13/14.

  12. InvestigationL&I investigation

    Case CF-2022-012285 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  13. InvestigationL&I investigation

    Case CF-2021-058350 · PASSED

    The cited inspection visit was marked passed.

  14. InvestigationL&I investigation

    Case CF-2021-058350 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  15. InvestigationL&I investigation

    Case CF-2021-058350 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  16. PermitNew Construction

    Permit EP-2020-010626 · Completed

    Temporary 100 Amp Service as per 2017 nec

  17. PermitNew Construction

    Permit CP-2020-005326 · Completed

    NEW CONSTRUCTION OF A FIVE (5) STORY DETACHED STRUCTURE FOR USE AS TWENTY-EIGHT (28) DWELLING UNITS AS PER APPROVED PLANS. BUILDING REQUIRED TO BE FULLY SPRINKLERED PER NFPA 13 AND INCLUDE STANDPIPES PER NFPA 14. FIRE RETARDANT TREATED STUDS AND SHEATHING REQUIRED FOR TYPE III CONSTRUCTION. FIRE WATCH REQUIRED PER CODE BULLETIN F-2001.*2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK** AMENDMENT APPROVED 12/16/22 AMEND NEW CONSTRUCTION PERMIT CP-2020-005326 TO INCLUDE 2 HOUR RATED MECHANICAL SHAFT AS PER APPROVED PLANS.

  18. PermitNew construction, addition, GFA change

    Permit ZP-2021-001125 · Issued

    FOR THE AMENDMENT TO PERMIT #643472 TO ELIMINATE PILOTHOUSE AND ROOF DECK, AND CHANGE ELEVATION TO A HEIGHT OF 58.5'. SIZE AND LOCATION AS SHOWN IN THE APPLICATION/PLANS.

  19. PermitFoundation

    Permit 924077 · Expired

    FOR THE ERECTION OF A FOUNDATION ONLY FOR A FUTURE SIX (6) STORY DETACHED STRUCTURE, AS PER PLANS; NO OTHER WORK ON THIS PERMIT; OWNER IS RESPONSIBLE FOR CHANGES TO FOUNDATION UPON FINAL BUILDING PERMIT REVIEW; SEE AP#643472 FOR ZONING APPROVAL OF BUILDING FOOTPRINT.

Where this comes from

Methodology & freshness

This report was assembled Jul 26, 2026, 6:28 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)