Commercial property report

4237-45 Walnut St

1 story7,800 sqftRM1built 1900

Property at a glanceOffices

42nd & Walnut Street Corp

2026 assessment
$2.2M OPA value, not a listing price
2027 published assessment
$2.3M Future roll, not the current tax bill
Neighborhood area
University City · West Powelton Approximate · based on ZIP 19104
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $2,340,000. It is not yet the billed-year tax basis.

$0$1.3M$2.5M$2.3M2005200920132017202120252027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record89 events · exact dates, newest first
  1. InspectionL&I investigation
  2. CertificationSprinkler Certification
  3. L&I violationFIRE RESISTANCE RATED CONSTRUCTION
  4. L&I violationFIRE EXTINGUISHER HANGERS & BRACKETS
  5. InspectionL&I investigation
  6. InspectionL&I investigation
  7. CertificationFire Alarm Certification
  8. InspectionL&I investigation
  9. L&I violationFDC SIGNAGE REQUIRED
  10. L&I violationPERIODIC TESTING
  11. InspectionL&I investigation
  12. InspectionL&I investigation
  13. CertificationSprinkler Certification
  14. CertificationSprinkler Certification
  15. CertificationSprinkler Certification
  16. InspectionL&I investigation
  17. L&I violationSUBMISSION OF CERTIFICATIONS
  18. L&I violationMANUAL FIRE ALARM BOX SIGNS
  19. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  20. L&I violationFIRE EXTINGUISHER HANGERS & BRACKETS
  21. CertificationSprinkler Certification
  22. CertificationFire Alarm Certification
  23. InspectionL&I investigation
  24. LicenseThe Sherwin-Williams Company: Hazardous Materials L&I license filing initially issued
  25. InspectionL&I investigation
  26. L&I violationFIRE ALARM TESTED/CERTIFIED
  27. L&I violationSAFETY DATA SHEETS/CONTAINER
  28. L&I violationNFPA 704 SIGNS
  29. L&I violationFIRE EXTINGUISHERS TAGGED
  30. L&I violationFIRE SUPPRESSION CERTIFICATION
  31. InspectionL&I investigation
  32. LicenseThe Sherwin-Williams Company: Dumpster License - Private Property L&I license filing initially issued
  33. PermitAlterations
  34. PermitAddition and/or Alteration
  35. PermitAddition and/or Alterations
  36. PermitAddition and/or Alterations
  37. PermitAddition and/or Alteration
  38. PermitAddition and/or Alteration
  39. PermitSign
  40. AppealZBA Permit Denial - Variance
  41. PermitSigns (Accessory / Non-Accessory)
  42. InspectionPRECOURT (likely: pre-court compliance inspection)
  43. AppealZoning board appeal
  44. AppealZoning board appeal
  45. InspectionBP_BLDG
  46. L&I violationSPEC INSP- NOT COMPLIED WITH
  47. InspectionBP_BLDG
  48. PermitElectrical
  49. PermitElectrical
  50. PermitMechanical
  51. PermitElectrical
  52. PermitPlumbing
  53. PermitSuppression
  54. PermitSuppression
  55. PermitMajor alteration
  56. PermitElectrical
  57. PermitSign
  58. PermitZoning/use
  59. AppealZoning board appeal
  60. PermitZoning
  61. PermitMechanical
  62. PermitSuppression
  63. PermitElectrical
  64. PermitMajor alteration
  65. InspectionPRECOURT (likely: pre-court compliance inspection)
  66. InspectionPRECOURT (likely: pre-court compliance inspection)
  67. InspectionADMIN INSP (likely: administrative inspection)
  68. InspectionADMIN INSP (likely: administrative inspection)
  69. InspectionADMIN INSP (likely: administrative inspection)
  70. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  71. InspectionADMIN INSP (likely: administrative inspection)
  72. PermitSuppression
  73. PermitMechanical
  74. PermitZoning admin review
  75. PermitElectrical
  76. PermitSuppression
  77. PermitElectrical
  78. PermitPlumbing
  79. PermitPlumbing
  80. PermitMajor alteration
  81. PermitZoning/use
  82. PermitFast form building
  83. AppealZoning board appeal
  84. PermitAdministrative
  85. PermitAdministrative
  86. PermitAdministrative
  87. LicenseRITE AID OF PENNSYLVANIA INC (DBA RITE AID): Food Establishment, Retail Perm Location (Large) business license marked inactive
  88. AppealZoning board appeal
  89. LicenseRITE AID OF PENNSYLVANIA INC (DBA RITE AID): Food Establishment, Retail Perm Location (Large) business license initially issued

Verify the public record

$30,136/year estimated property tax

2026 taxable assessment $2,152,900 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $2,340,000. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 883077710
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Where the record looks off

Conflicts in City paperwork. Flags on the data, not the property.

"Built 1900" is usually a placeholder

Philadelphia records use 1900 as a stand-in when the real construction year was never documented. Treat the age as unknown, not as 120+ years.

Property report

Commercial property

Offices, recorded in the City's offices category. The public record and owner trail follow.

2 open violations

What it is
Offices Off Bld N/Com W/Pkg Mason
Owner
42nd & Walnut Street Corp
$ / sq ft
$300 above the $142 median for 753 offices parcels citywide
Interior area
7,800 sqft
Lot size
22,811 sqft
Stories
1
Built
1900
Zoning
RM1

Recorded owner

Who's behind it

42nd & Walnut Street Corp · corporate / LLC owner

• Tax bills mail to 1315 Providence Rd, Secane PA, 19018 — outside Philadelphia

Block context

4200 block of Walnut St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 4235 Walnut St  ·  4233 Walnut St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
RITE AID OF PENNSYLVANIA INC (DBA RITE AID)Inactive

Food Establishment, Retail Perm Location (Large) · Initial issue date Oct 28, 2005 · Terminal license date Apr 19, 2007

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 89 dated rows
  1. InvestigationL&I investigation

    Case CF-2026-004530 · PASSED

    The cited inspection visit was marked passed.

  2. CertificationSprinkler Certification

    Certification BC-2026-003945 · Certified

    Expires 2027-02-05

  3. ViolationFIRE RESISTANCE RATED CONSTRUCTION

    Case CF-2026-004530 · Violation VI-2026-002881 · Code F-701.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  4. ViolationFIRE EXTINGUISHER HANGERS & BRACKETS

    Case CF-2026-004530 · Violation VI-2026-002880 · Code F-906.7 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  5. InvestigationL&I investigation

    Case CF-2026-004530 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  6. InvestigationL&I investigation

    Case CF-2025-105537 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  7. CertificationFire Alarm Certification

    Certification BC-2025-031983 · Certified

    Expires 2026-11-18

  8. InvestigationL&I investigation

    Case CF-2025-105537 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  9. ViolationFDC SIGNAGE REQUIRED

    Case CF-2025-105537 · Violation VI-2025-075568 · Code F-912.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  10. ViolationPERIODIC TESTING

    Case CF-2025-105537 · Violation VI-2025-075566 · Code F-901.6.4 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  11. InvestigationL&I investigation

    Case CF-2023-087218 · PASSED

    The cited inspection visit was marked passed.

  12. InvestigationL&I investigation

    Case CF-2025-105537 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  13. CertificationSprinkler Certification

    Certification BC-2025-003765 · Certified

    Expires 2026-02-04

  14. CertificationSprinkler Certification

    Certification BC-2024-033106 · Certified

    Expires 2025-12-10

  15. CertificationSprinkler Certification

    Certification BC-2024-007424 · Deficient

  16. InvestigationL&I investigation

    Case CF-2023-087218 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  17. ViolationSUBMISSION OF CERTIFICATIONS

    Case CF-2023-087218 · Violation VI-2023-065989 · Code F-901.6.4.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  18. ViolationMANUAL FIRE ALARM BOX SIGNS

    Case CF-2023-087218 · Violation VI-2023-065987 · Code F-907.4.2.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  19. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2023-087218 · Violation VI-2023-065986 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  20. ViolationFIRE EXTINGUISHER HANGERS & BRACKETS

    Case CF-2023-087218 · Violation VI-2023-065988 · Code F-906.7 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  21. CertificationSprinkler Certification

    Certification BC-2023-016331 · Deficient

  22. CertificationFire Alarm Certification

    Certification BC-2023-003853 · Certified

    Expires 2024-02-20

  23. InvestigationL&I investigation

    Case CF-2021-099353 · PASSED

    The cited inspection visit was marked passed.

  24. License issue eventThe Sherwin-Williams Company: Hazardous Materials L&I license filing initially issued

    License 883406 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  25. InvestigationL&I investigation

    Case CF-2021-099353 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  26. ViolationFIRE ALARM TESTED/CERTIFIED

    Case CF-2021-099353 · Violation VI-2021-071522 · Code FC-13-915.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  27. ViolationSAFETY DATA SHEETS/CONTAINER

    Case CF-2021-099353 · Violation VI-2021-071539 · Code FC-13-2701.8 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. ViolationNFPA 704 SIGNS

    Case CF-2021-099353 · Violation VI-2021-071538 · Code FC-13-2703.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. ViolationFIRE EXTINGUISHERS TAGGED

    Case CF-2021-099353 · Violation VI-2021-071527 · Code FC-13-906.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  30. ViolationFIRE SUPPRESSION CERTIFICATION

    Case CF-2021-099353 · Violation VI-2021-071525 · Code FC-13-915.1(A) · COMPLIED

    Resolution: COMPLIED - BY ENFORCEMENT ACTION City marked this violation complied with; check the resolution date and live case for what was accepted.

  31. InvestigationL&I investigation

    Case CF-2021-099353 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  32. License issue eventThe Sherwin-Williams Company: Dumpster License - Private Property L&I license filing initially issued

    License 878121 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  33. PermitAlterations

    Permit PP-2021-011446 · Completed

    Install Eyewash Station.

  34. PermitAddition and/or Alteration

    Permit EP-2021-003076 · Completed

    Install new lighting, switches, sensors/controls, receptacles, relocate existing panel NAP, wiring hvac equipment. Relocating existing fire alarm devices as required. As per the 2017 nec & 2016 nfpa-72. ** The service, panels and feeders are existing.

  35. PermitAddition and/or Alterations

    Permit MP-2021-001986 · Completed

    FOR ALTERATIONS TO AN EXISTING HVAC MECHANICAL SYSTEM TO INCLUDE EXHAUST FANS, REGISTERS/GRILLES/DIFFUSERS, AND ASSOCIATED DUCTWORK.

  36. PermitAddition and/or Alterations

    Permit FP-2021-001012 · Completed

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 2016, STANDARD 13, TO INCLUDE AN EXISTING 6-INCH DIAMETER SERVICE LINE, NEW 6-INCH DIAMETER BACKFLOW PREVENTION ASSEMBLY, AND AN EXISTING DRY SYSTEM LINE TO REMAIN ON SITE SERVICING A CATEGORY II ORDINARY HAZARD.

  37. PermitAddition and/or Alteration

    Permit CP-2021-001861 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO AN EXISTING BUILDING. WORK TO INCLUDE EXTERIOR MODIFICATION AS PER APPROVED PLAN**EXISTING BUILDING IS FULLY SPRINKLERED. ** SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK **

  38. PermitAddition and/or Alteration

    Permit CP-2021-000968 · Completed

    FOR INTERIOR DEMOLITION OF THE EXISTING STRUCTURE AS PER PLANS.

  39. PermitSign

    Permit GP-2021-001715 · Completed

    Install two (2) statically illuminated LED accessory wall signs 80.33 Sq Ft 4'-0" x 20'-1" Replace one (1) face s on existing freestanding sign OAH 13'; 6'-0" x 12'-0" (72 Sq Ft) Sizes and locations will remain the same.

  40. AppealZBA Permit Denial - Variance

    Appeal ZP-2020-008015 · Completed · Granted with conditions

    Related permit ZP-2020-008015 · PERMIT FOR THE ERECTION OF TWO(2) FLATWALL SIGNS ( 80.33 SF EACH; 160.66 SFTOAL AREA OF SIGN); FOR THE REMOVAL OF TWO(2) EXISTING SIGNS ( SIGN # A AND SIGN $ B)AND FOR THE FACE CHANGE OF EXISTING FREE-STANDING SIGN ( WITH THE SAME SIZE). SI

  41. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2020-008015 · Completed

    FOR THE ERECTION OF TWO(2) FLATWALL SIGNS ( 80.33 SF EACH; 160.66 SF TOAL AREA OF SIGN); FOR THE REMOVAL OF TWO(2) EXISTING SIGNS ( SIGN # A AND SIGN $ B)AND FOR THE FACE CHANGE OF EXISTING FREE-STANDING SIGN ( WITH THE SAME SIZE). SIZE AND LOCATION AS SHOWN IN THE APPLICATION.

  42. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 254138 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  43. AppealZoning board appeal

    Appeal 31129 · OPEN · Granted with conditions

    Related permit 794087 · PERMIT FOR REMOVAL OF ALL EXISTING SIGNAGE & FOR THE ERECTION OF THREE (3) STATICALLY ILLUMINATED WALL SIGNS & REFACE OF EXISTING DOUBLE-FACED NON-ILLUMINATED FREESTANDING SIGN; SIZE & LOCATION AS SHOWN IN APPLICATION. FOR USE AS BUSINESS &

  44. AppealZoning board appeal

    Appeal 27479 · CLOSED · Withdrawn

    Related permit 671839 · PERMIT FOR THE ERECTION OF ONE (1) INTERNALLY-ILLUMINATED WALL SIGN AND ONE (1) NON-ILLUMINATED WALL SIGN ON AN EXISTING SEMI-DETACHED STRUCTURE AND THE REFACE OF ONE (1) PANEL OF AN EXISTING FRESTANDING SIGN. SIZE AND LOCATION AS SHOWN IN

  45. InvestigationBP_BLDG

    Case 467277 · PASSED

    The cited inspection visit was marked passed.

  46. ViolationSPEC INSP- NOT COMPLIED WITH

    Case 467277 · Violation 3458899 · Code A-304.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  47. InvestigationBP_BLDG

    Case 467277 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  48. PermitElectrical

    Permit 579394 · COMPLETED

    FURNISH AND INSTALL 5 STROBES AND 1 HORN/STROBE ONTO EXISTING APPROVED FIRE ALARM SYSTEM AS PER NFPA72 (WEST DISTRICT)

  49. PermitElectrical

    Permit 572859 · COMPLETED

    FURNISH AND INSTALL 1 NEW 2X4 LIGHT,8 LIGHT SENSORS,18 QUAD RECEPTACLES,6 GFI RECEPTACLES AND 8 RECEPTACLES PER 2008 NEC (HEALTH CARE)

  50. PermitMechanical

    Permit 577404 · COMPLETED

    INSTALL 2 NEW DIFFUSERS AND RELOCATE 8 DIFFUSSERS

  51. PermitElectrical

    Permit 577088 · COMPLETED

    INSTALL 14 NEW COMM OUTLETS W/PLENUM RATED CATEGORY 6-DATA CABLE, RUN CABLE TO EXISTIN COMM ROOM CABLE LENGTH 150' AS PER NEC 2008 (OFFICES) WEST DISTRICT

  52. PermitPlumbing

    Permit 575436 · COMPLETED

    FURNISH AND INSTALL 1 LAV AND 5 EXAM ROOM SINKS,CONNECT TO EXISTING SANITARY,VENT AND DOMESTIC WATER-THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  53. PermitSuppression

    Permit 574245 · COMPLETED

    RELOCATE 12 SPRINKLER HEADS A DISTANCE OF 6".

  54. PermitSuppression

    Permit 573945 · REVOKED

    RELOCATE 8 DIFFUSSERS AND INSTALL 2 NEW DIFFUSERS

  55. PermitMajor alteration

    Permit 567905 · COMPLETED

    FOR LEVEL II INTERIOR ALTERATIONS TO CREATE NEW EXAM ROOMS AND OFFICES IN AN EXISTING HEALTH CARE CLINIC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION SYSTEMS.

  56. PermitElectrical

    Permit 547323 · COMPLETED

    CONNECT 2 WALL SIGNS AND 1 FREE STANDING SIGN TO EXISTING LINES, 120V, 20A.... IN ACCORDANCE WITH 2008 NEC

  57. PermitSign

    Permit 525556 · EXPIRED

    FOR THE INSTALLATION OF TWO (2) INTERNALLY-ILLUMINATED WALL SIGNS ON AN EXISTING ONE-STORY STRUCTURE AND FOR THE INSTALLATION OF A FREESTANDING ACCESSORY SIGN. SEPARATE PERMIT REQUIRED FOR ELECTRICAL SYSTEM.

  58. PermitZoning/use

    Permit 465203 · COMPLETED

    INSTALLATION OF 2 INTERNALLY ILLUMINATED WALL SIGNS, REPLACEMENT OF CABINET ON FREE STANDING SIGN AND APPLICATION OF SELF ADHESIVE DOOR WINDOW VINALS

  59. AppealZoning board appeal

    Appeal 21980 · CLOSED · Granted

    Related permit 465203 · INSTALLATION OF 2 INTERNALLY ILLUMINATED WALL SIGNS, REPLACEMENT OF CABINET ON FREE STANDING SIGN AND APPLICATION OF SELF ADHESIVE DOOR WINDOW VINALS

  60. PermitZoning

    Permit 459894 · COMPLETED

    NEW CONSTRUCTION OF A FOUR STORY APT BUILDING WITH ACCESSORY PARKING.

  61. PermitMechanical

    Permit 449505 · COMPLETED

    FOR THE RELOCATION OF ONE (1) THERMOSTAT AND FOR THE ADDITION OF FOUR (4) RETURN VENTS AND ONE (1) DIFFUSER.

  62. PermitSuppression

    Permit 454174 · COMPLETED

    RELOCATION OF 6 SPRINKLER HEADS.

  63. PermitElectrical

    Permit 445523 · COMPLETED

    9 DUPLEX RECEPTACLES 12 QUAD RECEPTACLES 2 FLOOR BOXES RELOCATE 6 2X2 FIXTURES RELOCATE 2X4 FIXTURES INSTALL 4 NEW FIXTURES 9 SWITCHES 2 PANIC BUTTONS 2 DOME LIGHTS PER 2008 NEC (HEALTH CARE FACILITY)

  64. PermitMajor alteration

    Permit 442378 · COMPLETED

    LEVEL 2 INTERIOR ALTERATIONS TO AN EXISTING HEALTH CARE CLINIC.

  65. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 254138 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  66. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 254138 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  67. InvestigationADMIN INSP (likely: administrative inspection)

    Case 254138 · FAILED

    Legacy inspection shorthand; the title alone does not state what condition was examined. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  68. InvestigationADMIN INSP (likely: administrative inspection)

    Case 254138 · CLOSED

    Legacy inspection shorthand; the title alone does not state what condition was examined. City marked the record closed; open the case for the closing reason.

  69. InvestigationADMIN INSP (likely: administrative inspection)

    Case 254138 · FAILED

    Legacy inspection shorthand; the title alone does not state what condition was examined. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  70. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 254138 · Violation 2473571 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.

  71. InvestigationADMIN INSP (likely: administrative inspection)

    Case 254138 · FAILED

    Legacy inspection shorthand; the title alone does not state what condition was examined. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  72. PermitSuppression

    Permit 257282 · COMPLETED

    RELOCATE OR ADD 78 SPRINKLERS IN THE ATTIC AS PER PLANS.

  73. PermitMechanical

    Permit 253483 · COMPLETED

    NEW SUPPLY AND RETURN OF DUCTWORK GRP'S NEW ROOF TOP SPLIT SYSTEM AS PER PLANS.

  74. PermitZoning admin review

    Permit 260448 · COMPLETED

    ADMIN REQUEST FOR MINOR SITE PLAN APPROVAL OF SITE PLAN APPROVED BY ZBA ON 11-04-09. PERMIT #236907

  75. PermitElectrical

    Permit 255810 · COMPLETED

    INSTALL FIRE ALARM SYSTEM IN MEDICAL OFFICE BUILDING PER PLANS.

  76. PermitSuppression

    Permit 254932 · COMPLETED

    RELOCATION OR ADD 94 SPRINKLERS AS PER PLANS.SEPARATED PERMIT FOR BFP.

  77. PermitElectrical

    Permit 253415 · COMPLETED

    FIT OUT, OF EXISTING BUILDING INTO MEDICAL OFFICE INCLUDING NEW SERVICE, PANELS,LIGHTS,RECEPTACLES & HVAC POWER. FIRE ALARM WILL BE UNDER A SEPARATE PERMIT AS PER 2005 NEC (WEST DISTRICT)

  78. PermitPlumbing

    Permit 253784 · COMPLETED

    39 FIXTURES FOR DOCTORS OFFICE WITH PIPING AS PER PLANS,BFP WATTS 909 2" TYPE RPZ

  79. PermitPlumbing

    Permit 253900 · COMPLETED

    LATERAL,HT,HD,FAI 2"WD

  80. PermitMajor alteration

    Permit 247945 · COMPLETED

    ALTERATIONS OF EXISTING BLDG. INTO MEDICAL OFFICES AND OUTPATIENT FACILITY TO INCLUDE A VESTIBULE AND ENTRANCE CANOPY ADDITION, REPAIR OF A PORTION OF THE EXISTING ROOF AND INTERIOR RENOVATIONS AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING.

  81. PermitZoning/use

    Permit 236907 · COMPLETED

    USE TO BLDG A MEDICAL OFFICES HAVING IN PATIENT ONLY. BLDG B USES AS PERMITTED IN C-2 COMMERCIAL DISTRICT. WITH RECONFIGURATION OF EXISTING PRIVATE ACCESSORY PARKING LOT CREATING 39 SPACES INCLUDING 4HC FROM 48 SPACES INCLUDING 4 HC. WITH ACCESSORY SIGNAGE

  82. PermitFast form building

    Permit 247412 · COMPLETED

  83. AppealZoning board appeal

    Appeal 10129 · CLOSED · Granted with conditions

    Related permit 236907 · PERMIT FOR THE ERECTION OF A ONE (1) STORY ADDITION MAX HEIGHT NOT TO EXCEED 35 FT FOR USE AS ENTRANCE VESTIBULE ACCESSORY TO THE EXISTING BUILDING WITH A PROPOSED USE OF MEDICAL OFFICES (NO OVERNIGHT STAYS) WITH ACCESSORY TESTING AND LABOR

  84. PermitAdministrative

    Permit 228123 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY FOR LIVE THEATRICAL PERFORMANCES - SHORT TERM EVENT IN ACCORDANCE WITH VARIANCE CASE #B0923-05. EVENT TO OCCUR FROM SEPTEMBER 4, 2009 THRU SEPTEMBER 9, 2009.

  85. PermitAdministrative

    Permit 169278 · COMPLETED

    APPLICATION FOR TEMPORARY USE OF PREMISES FOR LIVE THEATRUCAL PERFORMANCES AUGUST 29 - SEPT. 13,2008.

  86. PermitAdministrative

    Permit 91907 · COMPLETED

    T.C.O.

  87. License terminal eventRITE AID OF PENNSYLVANIA INC (DBA RITE AID): Food Establishment, Retail Perm Location (Large) business license marked inactive

    License 338362 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  88. AppealZoning board appeal

    Appeal 1084 · CLOSED · Denied

    PERMIT FOR RETAIL STATE LIQUOR STORE.

  89. License issue eventRITE AID OF PENNSYLVANIA INC (DBA RITE AID): Food Establishment, Retail Perm Location (Large) business license initially issued

    License 338362 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 27, 2026, 9:58 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)