6 violation rows marked OPEN in 1 active case

The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.

Open City history ↗
Case CF-2026-006825

Notice Of Violation

IN VIOLATION

Opened Jan 22, 2026 · Latest inspection FAILED · Jul 23, 2026

  • Damper Certification ReportF-701.6.1.5
  • Inspection, Testing & MaintenanceF-901.6
  • Periodic TestingF-901.6.4
  • High-Rise BuildingF-105.6.3
  • RecordsF-1203.4.3
  • Penetrations Maintaining ProtectionF-703.1

OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.

Assessment and City record timeline

Published City assessments for this house against its block and ZIP. Dated City filings are marked on the same line. Select one to read it. Assessments are tax-roll values, not sale prices or appraisals.

$0$1.0M$2.0MZIP 19102 (Center City West) median$1.6M2006201020142018202220262027
Property assessmentBlock median & rangeZIP 19102 (Center City West) medianAssessmentL&I violationPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record97 events · exact dates, newest first
  1. InspectionL&I investigation
  2. PermitAddition and/or Alteration
  3. PermitAlterations
  4. PermitAddition and/or Alteration
  5. InspectionL&I investigation
  6. PermitAddition and/or Alteration
  7. LicenseDong Ahn & Hua Fang Wu: Rental landlord or residential registration initially issued
  8. PermitNew Construction or Additions
  9. InspectionL&I investigation
  10. L&I violationEQUIPMENT ROOMS
  11. L&I violationUNAPPROVED CONDITIONS
  12. L&I violationDOOR OPERATION
  13. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  14. L&I violationCOMMERCIAL SYSTEM TEST
  15. L&I violationDAMPER CERTIFICATION REPORT
  16. L&I violationINSPECTION, TESTING & MAINTENANCE
  17. L&I violationPERIODIC TESTING
  18. L&I violationHIGH-RISE BUILDING
  19. L&I violationRECORDS
  20. L&I violationPENETRATIONS MAINTAINING PROTECTION
  21. PermitAddition and/or Alterations
  22. PermitAddition and/or Alterations
  23. PermitAddition and/or Alteration
  24. PermitAddition and/or Alteration
  25. PermitAddition and/or Alteration
  26. PermitAddition and/or Alterations
  27. PermitAddition and/or Alterations
  28. PermitAddition and/or Alteration
  29. PermitAddition and/or Alteration
  30. PermitAddition and/or Alteration
  31. PermitAddition and/or Alterations
  32. PermitAddition and/or Alterations
  33. PermitAddition and/or Alteration
  34. PermitAlterations
  35. PermitAddition and/or Alteration
  36. PermitAddition and/or Alteration
  37. PermitAddition and/or Alterations
  38. PermitAddition and/or Alteration
  39. PermitAddition and/or Alteration
  40. PermitAddition and/or Alteration
  41. PermitAddition and/or Alteration
  42. PermitAlterations
  43. PermitAlterations
  44. PermitAddition and/or Alterations
  45. PermitAddition and/or Alteration
  46. PermitAddition and/or Alterations
  47. PermitAddition and/or Alterations
  48. PermitAddition and/or Alteration
  49. PermitChange of Use
  50. PermitAddition and/or Alteration
  51. PermitAddition and/or Alteration
  52. PermitAlterations
  53. PermitAddition and/or Alteration
  54. PermitAddition and/or Alterations
  55. PermitAddition and/or Alteration
  56. PermitAlterations
  57. PermitAddition and/or Alterations
  58. PermitAddition and/or Alterations
  59. PermitAddition and/or Alteration
  60. PermitAddition and/or Alterations
  61. PermitAddition and/or Alteration
  62. LicenseELIZABETH A DALE: Rental landlord or residential registration marked inactive
  63. InspectionL&I investigation
  64. InspectionL&I investigation
  65. InspectionL&I investigation
  66. L&I violationMARKING ON ACCESS DOORS
  67. L&I violationDOOR OPERATIONS
  68. L&I violationDOOR OPENING FORCE
  69. L&I violationSTORAGE IN BUILDINGS
  70. L&I violationPENETRATIONS MAINTAINING PROTECTION
  71. L&I violationDOOR OPERATION
  72. L&I violationEXIT SIGN ILLUMINATION
  73. L&I violationFIRE EVACUATION PLANS
  74. PermitAddition and/or Alteration
  75. PermitAddition and/or Alteration
  76. LicenseCORETRUST VALUE I LP: High Rise L&I license filing marked inactive
  77. LicenseARAMARK CORPORATION: Food Preparing and Serving business license marked inactive
  78. LicenseTWO LIBERTY PLACE RESTAURANT PARTNERS LLC (R2L): Food Preparing and Serving (30+ SEATS) business license marked inactive
  79. LicenseCIGNA CORPORATION (ARAMARK FOOD SERVICES): Food Preparing and Serving (30+ SEATS) business license marked inactive
  80. LicenseARAMARK CORPORATION: Food Preparing and Serving (30+ SEATS) business license initially issued
  81. PermitNew Construction
  82. LicenseARAMARK CORPORATION: Food Preparing and Serving business license initially issued
  83. PermitNew Construction
  84. LicenseELIZABETH A DALE: Rental landlord or residential registration initially issued
  85. PermitNew Construction
  86. PermitNew Construction
  87. PermitAlterations
  88. PermitAlterations
  89. LicenseRESIDENCES AT TWO LIBERTY PLACE CONDO ASSOC (RAY KENNEDY COMM MGR AGT): Rental landlord or residential registration marked inactive
  90. LicenseRIM KWANG: Food Establishment, Retail Permanent Location business license marked inactive
  91. LicenseINSURANCE CO OF NORTH AMERICA: High Rise L&I license filing marked inactive
  92. LicenseRESIDENCES AT TWO LIBERTY PLACE CONDO ASSOC (RAY KENNEDY COMM MGR AGT): Rental landlord or residential registration initially issued
  93. LicenseCORETRUST VALUE I LP: High Rise L&I license filing initially issued
  94. LicenseTWO LIBERTY PLACE RESTAURANT PARTNERS LLC (R2L): Food Preparing and Serving (30+ SEATS) business license initially issued
  95. LicenseCIGNA CORPORATION (ARAMARK FOOD SERVICES): Food Preparing and Serving (30+ SEATS) business license initially issued
  96. LicenseRIM KWANG: Food Establishment, Retail Permanent Location business license initially issued
  97. LicenseINSURANCE CO OF NORTH AMERICA: High Rise L&I license filing initially issued

Flags: active rental license · 6 L&I violation rows marked OPEN. Informational only. Not investment advice or a consumer report (FCRA).

Verify the public record

$20,588/year estimated property tax

2026 taxable assessment $1,470,800 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,642,800. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 888092164
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

The property, on paper

OPA physical field record.

Bedrooms
3
Bathrooms
3
Stories
1
Interior
2,350 sqft livable area
Basement
Full, finished city code 1
Heat
Forced hot air city code A
Central air
Yes
Exterior condition
Above average city code 3
Interior condition
Above average city code 3
Quality grade
B+ assessor's grade

OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.

Recorded owner

Who's behind it

Reliance Trust Company Of · corporate / LLC owner

• Tax bills mail to 500 Delaware Ave, Wilmington DE, 19801 — outside Philadelphia
• Holds an active rental license for this address

Block context

0 block of S 16th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 50 S 16th St  ·  50 S 16th St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
ARAMARK CORPORATIONActive

Food Preparing and Serving (30+ SEATS) · Initial issue date Feb 13, 2020 · Filed expiration Feb 12, 2027

ARAMARK CORPORATIONInactive

Food Preparing and Serving · Initial issue date Oct 11, 2019 · Terminal license date Dec 9, 2020

TWO LIBERTY PLACE RESTAURANT PARTNERS LLC (R2L)Inactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Nov 19, 2009 · Terminal license date Jun 29, 2020

CIGNA CORPORATION (ARAMARK FOOD SERVICES)Inactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Aug 29, 2006 · Terminal license date Jun 29, 2020

RIM KWANGInactive

Food Establishment, Retail Permanent Location · Initial issue date Jun 22, 2006 · Terminal license date Dec 22, 2012

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

Dong Ahn & Hua Fang WuActive

Rental · Initial issue date Feb 9, 2026 · Filed expiration Feb 8, 2027

ELIZABETH A DALEInactive

Rental · Initial issue date Jul 16, 2019 · Terminal license date Sep 13, 2022

RESIDENCES AT TWO LIBERTY PLACE CONDO ASSOC (RAY KENNEDY COMM MGR AGT)Inactive

Rental · Initial issue date Apr 7, 2011 · Terminal license date Apr 29, 2016

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 97 dated rows
  1. InvestigationL&I investigation

    Case CF-2026-006825 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  2. PermitAddition and/or Alteration

    Permit EP-2026-005678 · Issued

    New circuits: Install new circuit from panel to new location (1) cook-top, (1) wall oven (1) microwave, (2) counter-top, (1) fridge, (1) dishwasher, (1) g.disposal, (1) general lighting Lighting: Install dimmer switch, switch control wire, feed wire, customer provided light fixture or recessed lights. Recessed: (4) kitchen fixtures customer provided: (2) section of under-cabinet lights, (4) pendant lights Receptacles: Install feed wire, outlet box and standard white receptacle or customer provided under-cabinet outlet strip (4) kitchen, (2) under-cabinet outlet strip (customer provided), all appliances

  3. PermitAlterations

    Permit PP-2026-006245 · Issued

    Kitchen renovation Relocate drain and water lines to new fixture locations Install finished fixtures: kitchen sink, disposal, dishwasher Relocate 3" stack

  4. PermitAddition and/or Alteration

    Permit CP-2026-001498 · Issued

    FOR LEVEL II ALTERATIONS TO INCLUDE NEW FLOORING, FIXTURES, FURNISHINGS, AND FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  5. InvestigationL&I investigation

    Case CF-2026-006825 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  6. PermitAddition and/or Alteration

    Permit EP-2026-000111 · Issued

    Wire 80 recessed lights, 70 receptacles, and install low voltage wiring including coaxial and cable for entertainment and 2017 NEC. Service is existing.

  7. License issue eventDong Ahn & Hua Fang Wu: Rental landlord or residential registration initially issued

    License 0999209 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  8. PermitNew Construction or Additions

    Permit PP-2026-000664 · Issued

    Install 1 kitchen sink, 1 dishwasher, 1 washing machine box, 1 laundry sink, 5 lavatories, 3 shower/tub and 3 water closets. All work to be done according to the 2018 PPC and per approved plans.

  9. InvestigationL&I investigation

    Case CF-2026-006825 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  10. ViolationEQUIPMENT ROOMS

    Case CF-2026-006825 · Violation VI-2026-004379 · Code F-315.3.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  11. ViolationUNAPPROVED CONDITIONS

    Case CF-2026-006825 · Violation VI-2026-004388 · Code F-604.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  12. ViolationDOOR OPERATION

    Case CF-2026-006825 · Violation VI-2026-004382 · Code F-705.2.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  13. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2026-006825 · Violation VI-2026-004329 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  14. ViolationCOMMERCIAL SYSTEM TEST

    Case CF-2026-006825 · Violation VI-2026-004330 · Code F-904.12.5.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  15. ViolationDAMPER CERTIFICATION REPORT

    Case CF-2026-006825 · Violation VI-2026-004327 · Code F-701.6.1.5 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  16. ViolationINSPECTION, TESTING & MAINTENANCE

    Case CF-2026-006825 · Violation VI-2026-004326 · Code F-901.6 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  17. ViolationPERIODIC TESTING

    Case CF-2026-006825 · Violation VI-2026-004325 · Code F-901.6.4 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  18. ViolationHIGH-RISE BUILDING

    Case CF-2026-006825 · Violation VI-2026-004323 · Code F-105.6.3 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  19. ViolationRECORDS

    Case CF-2026-006825 · Violation VI-2026-004328 · Code F-1203.4.3 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  20. ViolationPENETRATIONS MAINTAINING PROTECTION

    Case CF-2026-006825 · Violation VI-2026-004331 · Code F-703.1 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  21. PermitAddition and/or Alterations

    Permit MP-2026-000085 · Issued

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  22. PermitAddition and/or Alterations

    Permit FP-2025-002217 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (22) sprinkler heads, per NFPA 13

  23. PermitAddition and/or Alteration

    Permit CP-2025-004631 · Issued

    FOR LEVEL II ALTERATIONS TO CONVERT TWO UNITS INTO ONE UNIT TO INCLUDE NEW PARTITIONS, FIXTURES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. *2018 IEBC*

  24. PermitAddition and/or Alteration

    Permit EP-2025-010156 · Completed

    INSTALL 1 SPERKER/STROBE AND 1 STROBE. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.

  25. PermitAddition and/or Alteration

    Permit EP-2025-009937 · Completed

    Relocate 2 exit, 1 switch. Install 1 switch, 2 receptacles, 5 furniture power. ALL WORK TO BE DONE ACCORDING TO THE 2017 NEC ABD PER PLANS.

  26. PermitAddition and/or Alterations

    Permit FP-2025-001984 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (9) SPRINKLER HEADS ON THE 18TH FLOOR, PER NFPA 13

  27. PermitAddition and/or Alterations

    Permit MP-2025-004865 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES - For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Furnish labor to relocate 6 existing diffusers, with no wall penetrations, and within a single tenant space on the 18th floor - Suite 1810.

  28. PermitAddition and/or Alteration

    Permit CP-2025-004700 · Completed

    FOR LEVEL II ALTERATIONS TO A PORTION OF THE 18TH FLOOR OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. **IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. ** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**

  29. PermitAddition and/or Alteration

    Permit EP-2025-005223 · Completed

    INSTALL FIRE ALARM WIRING AND DEVICES TO THE OFFICE SPACE ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.

  30. PermitAddition and/or Alteration

    Permit EP-2025-004833 · Completed

    INSTALL TEMPORARY WIRING FOR ON SITE POWER SOURCE. INSTALL WIRING, LIGHTING, SWITCHES TELECOMMUNICATIONS WIRING AND RECEPTACLES OUTLETS ACCORDING TO THE 2017 NEC AND PER PLANS. *******THE FIRE ALARM PERMIT WILL BE OBTAIN SEPARATELY.********

  31. PermitAddition and/or Alterations

    Permit MP-2025-002777 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW OFFICE LAYOUT ON THE 33RD FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS. *2018 IMC REVIEW*

  32. PermitAddition and/or Alterations

    Permit FP-2025-001047 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 67 Sprinkler Heads

  33. PermitAddition and/or Alteration

    Permit EP-2025-004683 · Completed

    Furnish & install (50) Category 6 plenum cables from the existing Server Room to the customer indicated workstation Install new customer-provided card readers and access control panel for (3) doors. All locking hardware is to be provided by others.

  34. PermitAlterations

    Permit PP-2025-006448 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  35. PermitAddition and/or Alteration

    Permit CP-2025-002289 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS TO A PORTION OF EXISTING TENANT SPACE IN AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE SELECTIVE PARTITION DEMOLITION AND THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WOR

  36. PermitAddition and/or Alteration

    Permit EP-2025-003760 · Completed

    Reconfigure existing power & lighting using existing circuits to new layout as per 2017 NEC.

  37. PermitAddition and/or Alterations

    Permit MP-2025-002452 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Additional permits may be required. Furnish labor to relocate 6 existing diffusers with no wall penetrations within a single tenant space area. NO APPLIANCES

  38. PermitAddition and/or Alteration

    Permit EP-2025-003963 · Completed

    Furnish and install twelve (12) new Category 6 cables to new Server Room. Relocate existing cable to new Server Room. Average cable pull is 125'.

  39. PermitAddition and/or Alteration

    Permit CP-2025-000309 · Expired

    FOR LEVEL II INTERIOR ALTERATIONS WITH NO CHANGE IN OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  40. PermitAddition and/or Alteration

    Permit EP-2025-002786 · Completed

    PROVIDE TEMPORARY POWER WHILE JOB IS BEING DEMO. RECONNECT EXISTING POWER AND REPLACE LIGHTING, SWITCHES AND RECEPTACLE OUTLETS ACCORDING TO THE 2017 NEC AND PER PLANS.

  41. PermitAddition and/or Alteration

    Permit EP-2025-003347 · Completed

    Furnish and install thirty-six (36) Category 6 jacks from the Server Room to workstations. Average cable pull is 150 feet.

  42. PermitAlterations

    Permit PP-2025-003783 · Completed

    Furnish and install (2) new plumbing fixtures, (1) pantry sink and (1) water heater, connecting to existing piping. All piping must be metallic and installed to the 2018 PPC sec 919

  43. PermitAlterations

    Permit PP-2025-004400 · Completed

    Furnish and install (2) new plumbing fixtures, (1) pantry sink and (1) electric hot water heater, connecting to existing piping.

  44. PermitAddition and/or Alterations

    Permit FP-2025-000680 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (16) sprinkler heads on the 34th floor, per NFPA 13

  45. PermitAddition and/or Alteration

    Permit CP-2025-001680 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS TO A PORTION OF THE 34TH FLOOR OF AN EXISTING HIGH RISE BUILDING, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  46. PermitAddition and/or Alterations

    Permit MP-2025-001730 · Completed

    PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. Suite 2600 26th Floor Furnish labor to relocate 12 existing diffusers with no wall penetrations within a single tenant space area, in compliance with attached signed EZ Permit Standards, Ductwork and Warm-Air Appliances Form

  47. PermitAddition and/or Alterations

    Permit FP-2025-000572 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (39) SPRINKLER HEADS AS PER NFPA 13

  48. PermitAddition and/or Alteration

    Permit CP-2025-001434 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS TO AN EXISTING TENANT SPACE ON THE 26 TH FLOOR LEVEL OF AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE SELECTIVE PARTITION DEMOLITION AND THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  49. PermitChange of Use

    Permit ZP-2024-012630 · Issued

    Residential - Household Living - Multi-Family

  50. PermitAddition and/or Alteration

    Permit EP-2024-011791 · Completed

    Note 1 : Audio-Visual Low Voltage Cabling and Equipment Installation in 22 Rooms. Includes cabling, interconnects, low voltage hookpath, speakers, microphones, monitors, mounts, system controllers, digital signal processors, and video conferencing equipment. All high voltage electrical outlets, circuits, wiring, and conduit provided by others.

  51. PermitAddition and/or Alteration

    Permit EP-2024-008136 · Completed

    INSTALL WIRING, LIGHTING, SWITCHES, EXIT SIGNS AND RECEPTACLE OUTLETS ACCORDING TO THE 2017 NEC. INSTALL FIRE ALARM SYSTEM ACCORDING TO THE 2016 NFPA 72 AND PER PLANS.

  52. PermitAlterations

    Permit PP-2024-011039 · Completed

    Remove and replace (30) plumbing fixtures with same, (14) water closets, (12) lavatories and (4) urinal, connecting to existing piping.

  53. PermitAddition and/or Alteration

    Permit EP-2024-008125 · Completed

    Install 557 light fixtures, 24 exits, 185 switches, 249 receptacles, 43 floor receptacles, 41 equipment power, 1 bus switch, 1 480/277 volt panel, 2 208/120 volt panels, 4 meter as per 2017 NEC. Fire Alarm: Install 123 fire alarm device as per 2016 NFPA 72.

  54. PermitAddition and/or Alterations

    Permit MP-2024-003615 · Completed

    FOR THE INSTALLATION OF HVAC APPLIANCES, GRDs, AND ASSOCIATED DUCTWORK AND PIPING AT THE 36TH AND 37TH FLOORS. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC AND APPLIANCE MANUFACTURER SPECIFICATIONS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE CP-2024-003414 FOR ASSOCIATED BUILDING PERMIT.

  55. PermitAddition and/or Alteration

    Permit EP-2024-007984 · Completed

    AMEND TO REFFLECT THE ACTUAL CONTRACT VALUE AND WORK Install security cabling & hardware associated with card access for (11) doors. Install camera cabling & camera’s associated with surveillance system for (12) cameras. Install structured cabling (25) flush mount dual Category 6 location, (49) surface mount single Category 6A wireless access point locations (6) flush mount triple Category 6 locations, (8) floor mount dual Category 6 locations, (17) flush mount triple (2 Category 6/1 coax) AV locations, (4) flush mount quad Category 6 locations, (6) flush mount single Category 6 locations, (30) additional Category 6 locations. Provide labor to install all racks and termination hardware in each Server room on the 36th & 36th Floor. Install LV cabling, (69) speakers and control panel(s) associated with Sound Masking System.

  56. PermitAlterations

    Permit PP-2024-011022 · Completed

    Furnish and install (3) new plumbing fixtures, as follows, (2) kitchen sinks and (1) wellness sink, connecting to existing piping.

  57. PermitAddition and/or Alterations

    Permit MP-2024-003287 · Completed

    FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM TO INSTALL FAN TERMINAL UNITS, VAVs, EXHAUST FAN, GRDs, AND ASSOCIATED DUCTWORK THROUGHOUT RENOVATED TOILET ROOMS AT THE 36TH AND 37TH FLOORS. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN PROFESSIONAL PRIOR TO START OF WORK. SEE CP-2024-003433 FOR ASSOCIATED BUILDING PERMIT.

  58. PermitAddition and/or Alterations

    Permit FP-2024-001621 · Completed

    RELOCATE (207) SPRINKLER HEADS AS PER NFPA 13

  59. PermitAddition and/or Alteration

    Permit CP-2024-003414 · Completed

    FOR LEVEL II ALTERATIONS TO THE 36TH AND 37TH FLOORS OF AN EXISTING STRUCTURE. FOR USE AS A BUISNESS OCCUPANCY, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS. AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. TENANT SPACES ARE FULLY SPRINKLERED. ALL WORK TO BE DONE AS PER APPROVED PLANS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  60. PermitAddition and/or Alterations

    Permit FP-2024-001581 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (18) SPRINKLER HEADS AS PER NFPA 13

  61. PermitAddition and/or Alteration

    Permit CP-2024-003433 · Completed

    FOR LEVEL II ALTERATIONS TO EXISTING RESTROOMS ON THE 36TH AND 37TH FLOORS OF AN EXISTING HIGH RISE BUILDING, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ** NO CERTIFICATE OF OCCUPANCY REQUIRED FOR THIS WORK. ALTERATIONS SHALL BE DONE IN A MANNER THAT DOES NOT IMPACT THE EGRESS OR THE LEVEL OF FIRE PROTECTION PROVIDED AS PER SECTION A-701.1 (EXCEPTION 2) OF THE PHILADELPHIA ADMINISTRATIVE CODE **

  62. License terminal eventELIZABETH A DALE: Rental landlord or residential registration marked inactive

    License 818214 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  63. InvestigationL&I investigation

    Case CF-2022-058871 · PASSED

    The cited inspection visit was marked passed.

  64. InvestigationL&I investigation

    Case CF-2022-058871 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  65. InvestigationL&I investigation

    Case CF-2022-058871 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  66. ViolationMARKING ON ACCESS DOORS

    Case CF-2022-058871 · Violation VI-2022-042776 · Code F-901.4.6.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  67. ViolationDOOR OPERATIONS

    Case CF-2022-058871 · Violation VI-2022-042775 · Code F-1010.1.9 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  68. ViolationDOOR OPENING FORCE

    Case CF-2022-058871 · Violation VI-2022-042774 · Code F-1010.1.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  69. ViolationSTORAGE IN BUILDINGS

    Case CF-2022-058871 · Violation VI-2022-042773 · Code F-315.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  70. ViolationPENETRATIONS MAINTAINING PROTECTION

    Case CF-2022-058871 · Violation VI-2022-042772 · Code F-703.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  71. ViolationDOOR OPERATION

    Case CF-2022-058871 · Violation VI-2022-042771 · Code F-705.2.4 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  72. ViolationEXIT SIGN ILLUMINATION

    Case CF-2022-058871 · Violation VI-2022-042770 · Code F-1104.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  73. ViolationFIRE EVACUATION PLANS

    Case CF-2022-058871 · Violation VI-2022-042769 · Code F-404.2.1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  74. PermitAddition and/or Alteration

    Permit EP-2021-014143 · Completed

    Furnish and Install MC Cabling For Receptacles as per drawings. Circuits to originate from closest existing 20A circuits and/or existing 120V panel as per 2017 NEC.

  75. PermitAddition and/or Alteration

    Permit EP-2021-012829 · Completed

    - Removal of existing low voltage computer wire from furniture that is getting removed. - Installation of 46 new Category 6 network cable locations per NEC 2017

  76. License terminal eventCORETRUST VALUE I LP: High Rise L&I license filing marked inactive

    License 528184 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  77. License terminal eventARAMARK CORPORATION: Food Preparing and Serving business license marked inactive

    License 826368 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  78. License terminal eventTWO LIBERTY PLACE RESTAURANT PARTNERS LLC (R2L): Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 488269 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  79. License terminal eventCIGNA CORPORATION (ARAMARK FOOD SERVICES): Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 382792 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  80. License issue eventARAMARK CORPORATION: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 836912 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  81. PermitNew Construction

    Permit 1032937 · Completed

    INSTALL LOW VOLTAGE CATEGORY SIX(6) COMPUTERS, WIRE TO 325 LOCATIONS. INSTALL LOW VOLTAGE CABLING FOR THREE(3) DOOR ACCESS LOCATIONS AS PER 2014 NEC.

  82. License issue eventARAMARK CORPORATION: Food Preparing and Serving business license initially issued

    License 826368 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  83. PermitNew Construction

    Permit 1017005 · Completed

    RELOCATE 201 EXISTING SPRINKLER HEADS ON THE 17TH & 18TH FLOOR TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES.

  84. License issue eventELIZABETH A DALE: Rental landlord or residential registration initially issued

    License 818214 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  85. PermitNew Construction

    Permit 977623 · Completed

    Relocate 8 existing sprinkler heads

  86. PermitNew Construction

    Permit 971893 · Completed

    Relocate 4 existing sprinkler heads

  87. PermitAlterations

    Permit 953732 · Expired

    REPLACE 4 URINALS WITH NEW FIXTURES IN SAME LOCATION.

  88. PermitAlterations

    Permit 941157 · Expired

    35TH FL CORE MEN'S RM

  89. License terminal eventRESIDENCES AT TWO LIBERTY PLACE CONDO ASSOC (RAY KENNEDY COMM MGR AGT): Rental landlord or residential registration marked inactive

    License 529788 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  90. License terminal eventRIM KWANG: Food Establishment, Retail Permanent Location business license marked inactive

    License 374785 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  91. License terminal eventINSURANCE CO OF NORTH AMERICA: High Rise L&I license filing marked inactive

    License 353740 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  92. License issue eventRESIDENCES AT TWO LIBERTY PLACE CONDO ASSOC (RAY KENNEDY COMM MGR AGT): Rental landlord or residential registration initially issued

    License 529788 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  93. License issue eventCORETRUST VALUE I LP: High Rise L&I license filing initially issued

    License 528184 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  94. License issue eventTWO LIBERTY PLACE RESTAURANT PARTNERS LLC (R2L): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 488269 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  95. License issue eventCIGNA CORPORATION (ARAMARK FOOD SERVICES): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 382792 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  96. License issue eventRIM KWANG: Food Establishment, Retail Permanent Location business license initially issued

    License 374785 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  97. License issue eventINSURANCE CO OF NORTH AMERICA: High Rise L&I license filing initially issued

    License 353740 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

Unavailable when this report assembled: certifications. Unavailable does not mean no record.

Where this comes from

Methodology & freshness

This report was assembled Jul 26, 2026, 7:07 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: unavailable. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)