Industrial property report
500 E Hunting Park Ave
78,930 sqftI3built 1959
500 E Hunting Park LLC
Verify the public record
Property tax
Property-tax estimate unavailable
The taxable assessment was unavailable. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.
Payments, credits, interest, and the current amount due are maintained by the City.
OPA 884052400The assessment did not include a usable taxable value.
Historical delinquency sources No current conclusion
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Property report
Industrial property
Industrial building, recorded in the City's industrial category. The public record and owner trail follow.
Recorded owner
Who's behind it
500 E Hunting Park LLC · corporate / LLC owner
• Tax bills mail to 2015 Chatham Dr, Bensalem PA, 19020 — outside Philadelphia
Block context
500 block of E Hunting Park Ave. Compare parcels, ownership, and public-record history.
See the whole block →Next door: 501-31 E Hunting Park Ave · 533 E Hunting Park Ave
Open every source row 38 dated rows
- CertificationFire Alarm Certification
Certification BC-2026-009770 · Certified
Expires 2027-03-03
- Recorded transfer$3.5M transfer
2026
- CertificationSprinkler Certification
Certification BC-2026-014127 · Certified
Expires 2026-10-21
- CertificationSprinkler Certification
Certification BC-2026-012739 · Deficient
- CertificationSprinkler Certification
Certification BC-2026-013680 · Deficient
- CertificationSprinkler Certification
Certification BC-2026-001170 · Deficient
- CertificationFire Alarm Certification
Certification BC-2025-027632 · Certified
Expires 2026-09-12
- CertificationFire Alarm Certification
Certification BC-2025-015083 · Certified
Expires 2026-03-12
- CertificationFire Alarm Certification
Certification BC-2025-010645 · Certified
Expires 2026-03-12
- CertificationFire Alarm Certification
Certification BC-2025-003449 · Certified
Expires 2026-02-07
- CertificationFire Alarm Certification
Certification BC-2025-000881 · Certified
Expires 2025-12-08
- CertificationSprinkler Certification
Certification BC-2024-032088 · Certified
Expires 2025-10-27
- CertificationFire Alarm Certification
Certification BC-2024-009572 · Certified
Expires 2025-03-01
- CertificationFire Alarm Certification
Certification BC-2024-009018 · Certified
Expires 2025-03-01
- PermitAddition and/or Alteration
Permit EP-2023-003147 · Issued
This Proposal is to tie in two outside tampers to the existing fire system. Control panel is an addressable Unimode 200 fire alarm system Contractor shall supply and run all wire, conduit & boxes JCI shall Install new addressable module(s) as per APPROVED DRAWINGS-2016 nfpa 72.
- CertificationFire Alarm Certification
Certification BC-2023-012945 · Certified
Expires 2024-03-09
- PermitAddition and/or Alterations
Permit FP-2022-002746 · Completed
FOR THE INSTALLATION OF 281 NEW SPRINKLERS HEADS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING. AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS. *********ADDITIONAL PERMIT REQUIRED FOR THE REMOVAL AND REPLACEMENT OF BACKFLOW PREVENTOR IN EXISTING VALVE PIT AND ADDITIONAL WORK IN PIT AREA. *********************
- PermitAddition and/or Alteration
Permit EP-2022-011461 · Expired
This proposal is to install two relays to release magnetic locks on fire activation. JCI shall install two relays, one in the front server room and one in the back corridor at the location of the access control power supply. See attached drawing for detail as per 2017 nec and nfpa 72
- CertificationFire Alarm Certification
Certification BC-2023-002920 · Certified
Expires 2023-11-22
- CertificationFire Alarm Certification
Certification BC-2022-016429 · Certified
Expires 2023-10-31
- CertificationSprinkler Certification
Certification BC-2022-016427 · Certified
Expires 2023-10-31
- PermitAddition and/or Alteration
Permit EP-2022-010141 · Completed
This is an addition to the existing system Control panel is an addressable Unimode 200 fire alarm system JCI shall Install new fire alarm power supply JCI shall install new system batteries JCI shall Install new addressable pull station(s) with back boxes JCI shall Install new addressable module(s) JCI shall Install new horn strobe(s) with back boxes JCI shall tie addressable modules onto an existing tamper switch JCI shall use outdoor rated wire, seal tight and a surge protector for this device JCI shall Install new SLC loop wiring JCI shall Install new A/V loop wiring As per 2016 NFPA 72.
- PermitAddition and/or Alterations
Permit FP-2022-000767 · Completed
FOR THE INSTALLATION OF 22 NEW TYCO PENDENT SPRINKLERS TO AN EXISTING FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING USING THE EXISTING 6" FIRE WATER SUPPY LINE, FIRE PUMP AND BACK FLOW PREVENTER. AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.
- PermitAddition and/or Alteration
Permit EP-2022-002252 · Completed
Provide raceway and wiring for exterior wall-mounted site lights and security gate as per 2017 NEC.
- PermitGeneral Earth Disturbance ONLY
Permit SP-2021-000903 · Completed
FOR A SITE IMPROVEMENT AS PER APPROVED PLANS. **EXTERIOR WORK ONLY**
- PermitAddition and/or Alteration
Permit EP-2021-008155 · Completed
JOHNSON CONTROLS/TYCO SHALL INSTALL A SEPARATE VISTA-128 COMBINATION PANEL AND AN AUDIO EMERGENCY ALERT SYSTEM FOR WEATHER AND CHEMICAL. THIS NEW SYSTEM SHALL BE MONITORED SEPARATELY FROM THE EXISTING FIRE ALARM SYSTEM THAT SHALL REMAIN UNALTERED. AUDIO DEVICES SHALL BE INSTALLED THROUGHOUT THE FACILITY. BLUE PULL STATIONS SHALL BE INSTALLED FOR CHEMICAL EVACUATIONS. YELLOW PULL STATIONS SHALL BE INSTALLED FOR A WEATHER EMERGENCY AS PER 2017 NEC.
- PermitAddition and/or Alterations
Permit MP-2021-001678 · Completed
Mechanical work, to include, installation of ductwork, exhaust fans and unit heaters, as per plans.
- PermitAlterations
Permit PP-2021-002013 · Expired
FOR THE ERECTION OF AN ADDITION ON AN EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS PER APPROVED PLANS, FOR AN EXTENSION OF AN EXISTING INDUSTRIAL PLANT, TO BE USED AS A UTILITY ROOM. BUILDING TO BE FULLY SPRINKLERED AS PER NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC. ELECTRICAL WORK: INSTALL 15KV SERVICE AND DUCT BANK, 4000 AMP SERVICE , REFEED EXISTING MDP'S. PROVIDE POWER FOR HVAC EQUIPMENT, LIGHTS , SWITCHES, RECEPTACLES INSTALL CABLE TRAY.AS PER THE 2017 NEC. *NO FIRE ALARM WORK ON THIS PERMIT.* MECHANICAL WORK: FOR THE INSTALLATION OF NEW APPLIANCES, ASSOCIATED DUCTWORK, ROOFTOP UNITS, AND DAMPERS AS PER APPROVED PLANS.
- PermitAddition and/or Alteration
Permit EP-2021-001329 · Completed
JOHNSON CONTROLS SHALL TIE IN NEW INITIATING DEVICES AND NOTIFICATION APPLIANCE INTO THE EXISTING UNIMODE 200 FIRE ALARM SYSTEM FOR THE UTILITY UPGRADE. ALL EXISTING DEVICES SHALL REMAIN AS PREVIOUSLY (AND ARE SHOWN FOR REFERENCE ONLY). AS PER NFPA 72
- PermitAddition and/or Alteration
Permit EP-2021-001174 · Completed
FOR THE ERECTION OF AN ADDITION ON AN EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS PER APPROVED PLANS, FOR AN EXTENSION OF AN EXISTING INDUSTRIAL PLANT, TO BE USED AS A UTILITY ROOM. BUILDING TO BE FULLY SPRINKLERED AS PER NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC. ELECTRICAL WORK: INSTALL 15KV SERVICE AND DUCT BANK, 4000 AMP SERVICE , REFEED EXISTING MDP'S. PROVIDE POWER FOR HVAC EQUIPMENT, LIGHTS , SWITCHES, RECEPTACLES INSTALL CABLE TRAY.AS PER THE 2017 NEC. *NO FIRE ALARM WORK ON THIS PERMIT.* MECHANICAL WORK: FOR THE INSTALLATION OF NEW APPLIANCES, ASSOCIATED DUCTWORK, ROOFTOP UNITS, AND DAMPERS AS PER APPROVED PLANS.
- PermitAlterations
Permit PP-2021-002014 · Completed
FOR THE ERECTION OF AN ADDITION ON AN EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS PER APPROVED PLANS, FOR AN EXTENSION OF AN EXISTING INDUSTRIAL PLANT, TO BE USED AS A UTILITY ROOM. BUILDING TO BE FULLY SPRINKLERED AS PER NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC. ELECTRICAL WORK: INSTALL 15KV SERVICE AND DUCT BANK, 4000 AMP SERVICE , REFEED EXISTING MDP'S. PROVIDE POWER FOR HVAC EQUIPMENT, LIGHTS , SWITCHES, RECEPTACLES INSTALL CABLE TRAY.AS PER THE 2017 NEC. *NO FIRE ALARM WORK ON THIS PERMIT.* MECHANICAL WORK: FOR THE INSTALLATION OF NEW APPLIANCES, ASSOCIATED DUCTWORK, ROOFTOP UNITS, AND DAMPERS AS PER APPROVED PLANS.
- PermitAddition and/or Alteration
Permit CP-2020-001211 · Completed
FOR THE ERECTION OF AN ADDITION ON AN EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS PER APPROVED PLANS, FOR AN EXTENSION OF AN EXISTING INDUSTRIAL PLANT, TO BE USED AS A UTILITY ROOM. BUILDING TO BE FULLY SPRINKLERED AS PER NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IBC. ELECTRICAL WORK: INSTALL 15KV SERVICE AND DUCT BANK, 4000 AMP SERVICE , REFEED EXISTING MDP'S. PROVIDE POWER FOR HVAC EQUIPMENT, LIGHTS , SWITCHES, RECEPTACLES INSTALL CABLE TRAY.AS PER THE 2017 NEC. *NO FIRE ALARM WORK ON THIS PERMIT.* MECHANICAL WORK: FOR THE INSTALLATION OF NEW APPLIANCES, ASSOCIATED DUCTWORK, ROOFTOP UNITS, AND DAMPERS AS PER APPROVED PLANS. AMENDMENT AS OF 8.26.2021: FOR MODIFICATION TO INCLUDE MICROPILES AS FOUNDATION SOLUTION DUE TO ISSUES DISCOVERED DURING EXCAVATIONS. ALL WORK PER GEOTECH REPORT, MICROPILE SPECS AND WITH CONTINOUTS SPECIAL INSPECTIONS.
- PermitNew construction, addition, GFA change
Permit ZP-2020-001495 · Completed
FOR THE ERECTION OF AN ADDITION ON AN EXISTING DETACHED STRUCTURE. SIZE AND LOCATION AS PER APPROVED PLANS.
- PermitOther (Descriptive)
Permit 26401 · Completed
- PermitOperations
Permit 25828 · COMPLETED
HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES: 09/14/19
- PermitOperations
Permit 25087 · COMPLETED
HOTWORKS: WELDING/CUTTING/SOLDERING/TORCH WORK - PERMIT EXPIRES: 8/17/18
- PermitElectrical
Permit 769089 · COMPLETED
INSTALLATION OF A CCTV SYSTEM THROUGHOUT PER 2008 NEC (WAREHOUSE)EAST DISTRICT
- PermitElectrical
Permit 766163 · COMPLETED
INSTALLATION OF A AUTOMATIC FIRE ALARM SYSTEM THROUGHOUT PER NFPA 72 (WAREHOUSE)
Unavailable when this report assembled: violations, investigations, appeals, licenses. Unavailable does not mean no record.
Where this comes from
- Assessment, spec sheet & owner: OPA Property Assessments, Office of Property Assessment
- Sales & deed history: Realty Transfer Tax records, Recorder of Deeds
- Permits, violations & inspections: L&I Property History · Atlas
- Tax delinquency snapshot · June 2022: Real Estate Tax Delinquencies, Dept. of Revenue
- Historical tax ledger & liens · through 2016: Real Estate Tax Balances, Dept. of Revenue
- Current property-tax balance: Verify with Philadelphia Revenue
- Zoning appeals: L&I & Zoning Board appeals
- Imagery: Street photo © Google · Aerial © Esri, Maxar
Methodology & freshness
This report was assembled Jul 29, 2026, 10:37 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: unavailable · Investigations: unavailable · Appeals: unavailable · Licenses: unavailable · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)