3 violation rows marked OPEN in 1 active case

The actual City titles, code sections, case posture, and latest recorded inspections are shown here instead of only an aggregate count.

Open City history ↗
Case CF-2026-025781

Notice Of Violation

IN VIOLATION

Opened Mar 20, 2026 · Latest inspection FAILED · Mar 20, 2026

  • Periodic TestingF-901.6.4
  • Suppression System Testing & MaintenanceF-903.5
  • Inspection, Testing & MaintenanceF-901.6

OPEN is the status in the fetched L&I file, not a new inspection by BlockReport. Read the notice for the cited condition and required correction, then verify the live case with L&I.

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $120,847,300. It is not yet the billed-year tax basis.

$0$100M$200M$121M201720192021202320252027
Property assessmentAssessmentL&I violationPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record67 events · exact dates, newest first
  1. L&I violationPERIODIC TESTING
  2. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  3. L&I violationINSPECTION, TESTING & MAINTENANCE
  4. InspectionL&I investigation
  5. License4B Ventures LLC (Lucky Duck PHL): Food Preparing and Serving (30+ SEATS) business license initially issued
  6. PermitSign
  7. PermitSigns (Accessory / Non-Accessory)
  8. PermitAddition and/or Alterations
  9. PermitAddition and/or Alteration
  10. PermitAddition and/or Alterations
  11. PermitAddition and/or Alterations
  12. LicenseLwin Family Co LLC (Oumi Sushi): Food Preparing and Serving business license initially issued
  13. PermitAddition and/or Alteration
  14. LicenseSprouts Farmer's Market, Inc. (Sprouts Farmers Market ): Food Establishment, Retail Perm Location (Large) business license initially issued
  15. PermitSign
  16. PermitAddition and/or Alterations
  17. PermitAddition and/or Alteration
  18. PermitSign
  19. PermitSigns (Accessory / Non-Accessory)
  20. PermitChange of Use
  21. LicenseRiverview Property Owner LLC (Rivermark Northern Liberties): Rental landlord or residential registration initially issued
  22. PermitAddition and/or Alteration
  23. PermitNew Construction
  24. PermitNew Construction or Additions
  25. PermitFoundation
  26. InspectionL&I investigation
  27. PermitSign
  28. PermitNew Construction
  29. PermitSign
  30. PermitNew construction, addition, GFA change
  31. PermitNew Construction
  32. PermitNew Construction
  33. PermitAddition and/or Alteration
  34. PermitChange of Use
  35. PermitNew Construction
  36. PermitSigns (Accessory / Non-Accessory)
  37. PermitNew Construction or Additions
  38. PermitAddition and/or Alteration
  39. PermitAddition and/or Alteration
  40. PermitNew Construction
  41. PermitNew Construction
  42. PermitNew Construction
  43. PermitNew Construction or Additions
  44. PermitNew Construction or Additions
  45. PermitNew Construction
  46. PermitTank Install/Removal
  47. PermitTank Install/Removal
  48. PermitNew construction, addition, GFA change
  49. InspectionL&I investigation
  50. PermitNew Construction
  51. PermitNew Construction
  52. L&I violationPIERS & WATERFRONT STRUCTURES INSPECTION REQUIRED
  53. InspectionL&I investigation
  54. PermitSitework with Onsite Utility Services
  55. PermitCombined Lot Line Relocation and New Dev…
  56. L&I violationSECURE ELECTRICAL EQUIPMENT
  57. L&I violationGFCI RECEPTACLE REQ'D
  58. L&I violationCONNECTOR-NEEDED AT BOX
  59. L&I violationNOT CONFORM TO PRC/NEC
  60. L&I violationWIRE/EQUIP IMPROPERLY ABANDONE
  61. L&I violationSPACE ABOUT EQUIPMENT
  62. L&I violationVENTILATION OF EQUIP
  63. L&I violationBOX-NEEDED AT TERMINATION
  64. L&I violationRACEWAY-SECURE & SUPPORT
  65. L&I violationOPENING-REQ'D TO CLOSE UNUSED
  66. L&I violationWIRE/EQUIP-REPLACE DEFEC/DAMAG
  67. L&I violationGROUND-SYSTEM PROPERLY

Verify the public record

$169,376/year estimated property tax

2026 taxable assessment $12,100,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $120,847,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881000326
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $12,100,000 of $121,000,000 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartments, recorded in the City's apartments category. The public record and owner trail follow.

3 open violations

What it is
Apartments Vacant Land Indust Acre+
Owner
Riverview Property Ownership LLC
$ / sq ft
$375 above the $147 median for 2,826 apartments parcels citywide
Corridor
Central Waterfront/Spring Garden city commercial corridor
Licensed units
470 active rental license
Interior area
322,000 sqft
Lot size
324,115 sqft
Stories
7
Built
2025
Zoning
CMX3

Recorded owner

Who's behind it

Riverview Property Ownership LLC · corporate / LLC owner

• Tax bills mail to 1420 Spring Hill Road, Mc Lean VA, 22102 — outside Philadelphia
• Holds an active rental license for this address

Block context

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
4B Ventures LLC (Lucky Duck PHL)Active

Food Preparing and Serving (30+ SEATS) · Initial issue date Mar 6, 2026 · Filed expiration Mar 5, 2027

Lwin Family Co LLC (Oumi Sushi)Active

Food Preparing and Serving · Initial issue date Jun 11, 2025 · Filed expiration Jun 10, 2027

Sprouts Farmer's Market, Inc. (Sprouts Farmers Market )Active

Food Establishment, Retail Perm Location (Large) · Initial issue date Jun 6, 2025 · Filed expiration Jun 5, 2027

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

Riverview Property Owner LLC (Rivermark Northern Liberties)Active

Rental · Initial issue date Dec 23, 2024 · Filed expiration Dec 22, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Inferred from public records · 2025-07-29 through 2026-07-29

Food and drink at this property

1 possible-opening record signal in this 12-month window. These are classifications, not confirmed announcements.

Inference, not an opening announcement. Possible-opening classifications are inferences from public permit and license records, not confirmed opening announcements. A permit is authorization for a stated scope, not proof that work occurred or finished. A license is an L&I registration, not proof that a business is open or operating. Food and drink uses the seven exact L&I license types already used by BlockReport. The City record does not support a reliable restaurant, bar, and cafe split. License renewals do not create new events. The opening date is the earliest initial issue date for a deduped OPA parcel, normalized business identity, and license type. Sources: L&I building permits and L&I business licenses, data through Jul 29, 2026.

Open every source row 67 dated rows
  1. ViolationPERIODIC TESTING

    Case CF-2026-025781 · Violation VI-2026-016052 · Code F-901.6.4 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  2. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2026-025781 · Violation VI-2026-016054 · Code F-903.5 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  3. ViolationINSPECTION, TESTING & MAINTENANCE

    Case CF-2026-025781 · Violation VI-2026-016053 · Code F-901.6 · OPEN

    The individual violation row was marked open in the assembled City file; verify the live notice and any later inspection.

  4. InvestigationL&I investigation

    Case CF-2026-025781 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  5. License issue event4B Ventures LLC (Lucky Duck PHL): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 1001337 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  6. PermitSign

    Permit GP-2026-001196 · Completed

    FOR THE ERECTION OF ONE (1) STATICALLY ILLUMINATED ACCESSORY PROJECTING SIGN AND TWO (2) DOOR SIGNS ON EXISTING STRUCTURE. SIZE AND LOCATION AS SHOWN ON PLANS. **SEPARATE PERMITS REQUIRED FOR ELECTRICAL WORK**

  7. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2025-012135 · Issued

    FOR ERECTION OF ONE (1) ILLUMINATED PROJECTING SIGN AND TWO (2) DOOR SIGNS ON EXISTING STRUCTURE (SIGNS DO NOT FACE A PUBLIC STREET). SIZE AND LOCATION AS SHOWN ON THE APPLICATION / PLAN.

  8. PermitAddition and/or Alterations

    Permit FP-2025-002070 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. MK FIRE PROTECTION TO RELOCATE 54 SPRINKLER HEADS

  9. PermitAddition and/or Alteration

    Permit EP-2025-006659 · Completed

    AMENDMENT: Install fire alarm as per 2016 NFPA 72. Electrical work to include: Upgrade 400 amp MDP to a 600 amp MDP from existing switchgear. Install receptacles, lighting, kitchen cooking equipment power, HVAC, and low voltage work as per 2017 NEC. ***FIRE ALARM WILL BE APPLIED FOR UNDER SEPARATE PERMIT***

  10. PermitAddition and/or Alterations

    Permit FP-2025-002039 · Issued

    EZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. Install FS #1 Tank FS (4.0/4.0/4.0 gallon) - Fire Cabinet Left - [covering 2 hoods]

  11. PermitAddition and/or Alterations

    Permit FP-2025-001299 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. MK FIRE PROTECTION TO RELOCATE 25 SPRINKLER HEADS

  12. License issue eventLwin Family Co LLC (Oumi Sushi): Food Preparing and Serving business license initially issued

    License 0981391 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  13. PermitAddition and/or Alteration

    Permit CP-2025-001204 · Completed

    FIT-OUT OF SHELL SPACE SR-3 ON THE GROUND FLOOR OF A NEW CONSTRUCTION BUILDING (SOUTH BUILDING, SEE PERMIT CP-2020-004758) FOR A SIT-DOWN RESTAURANT AS PER APPROVED PLANS. SEE NEW CONSTRUCTION PERMIT FOR FLOOD PROTECTION MEASURES. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 AND INCLUDE STANDPIPES PER NFPA 14. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  14. License issue eventSprouts Farmer's Market, Inc. (Sprouts Farmers Market ): Food Establishment, Retail Perm Location (Large) business license initially issued

    License 0980939 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  15. PermitSign

    Permit GP-2025-002950 · Completed

    FOR THE ERECTION OF FIVE (5) ACCESSORY STATIC INTERNALLY ILLUMINATED WALL SIGNS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK. SEE ZP-2025-001536 FOR ZONING APPROVAL.

  16. PermitAddition and/or Alterations

    Permit FP-2025-000794 · Completed

    EZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. Install 4.0 gallon kitchen Fire Suppression System, per UL 300

  17. PermitAddition and/or Alteration

    Permit EP-2025-003148 · Completed

    Connect five (5) statically illuminated “Sprouts Farmers Market” wall signs with illuminated channel letters to existing 120-v junction box power supplies already in place in walls, per plans. We are not running any new wiring or conduit, just connecting to the existing power supplies per plans. Connect one (1) statically illuminated LED “Sprouts Farmers Market” monument sign to existing 120-v junction box power supply already in place in monument, per plans. We are not running any new wiring or conduit, just connecting to the existing power supply per plans. Sign permits GP-2025-002950 and ZP-2025-001536. There is no interior wiring for this job, the interior wiring is already complete and was provided by others. We are not running any new wire, the wire is already in place, just connecting the signs to wiring already in place in the building and pylon.

  18. PermitSign

    Permit GP-2025-002194 · Completed

    FOR THE ERECTION OF ONE (1) STATIC ILLUMINATED FREESTANDING SIGN. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK, INCLUDING ALL ELECTRICAL WORK.

  19. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2025-001536 · Completed

    FOR THE ERECTION OF ACCESSORY SIGNS TO AN EXISTING STRUCTURE; SIZE AND LOCATION AS PER APPLICATION/PLAN

  20. PermitChange of Use

    Permit ZP-2025-000502 · Issued

    Eating and Drinking Establishments - Sit-Down Restaurant

  21. License issue eventRiverview Property Owner LLC (Rivermark Northern Liberties): Rental landlord or residential registration initially issued

    License 0968197 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  22. PermitAddition and/or Alteration

    Permit EP-2024-010057 · Completed

    Installation of new fire alarm system as per 2016 NFPA 72. New system will be interconnected to existing building system.

  23. PermitNew Construction

    Permit CP-2024-003821 · Completed

    INSTALLATION OF ART SCULPTURE ON PREVIOUSLY APPROVED FOUNDATIONS (SEE PERMIT SP-2024-000835) AS PER APPROVED PLANS. *2018 IBC REVIEW*

  24. PermitNew Construction or Additions

    Permit PP-2023-013926 · Completed

    Plumbing per plans AMENDMENT REQUEST 11/14/2024 - Change to layout of work area (same area/reduction) Revised gas piping sizes per 2 psi pressure system, added gas pressure regulators, revised floor sinks to hub drains, revised sewer layout to coordinated with shell building, updated layout to coordinate with fixture plan and proto updates.

  25. PermitFoundation

    Permit SP-2024-000835 · Completed

    FOR CONSTRUCTION OF FOUNDATION ONLY FOR ART SCUPTURE AT PUBLIC PLAZA ADJACENT TO NORTH BUILDING.

  26. InvestigationL&I investigation

    Case CF-2021-044567 · PASSED

    The cited inspection visit was marked passed.

  27. PermitSign

    Permit GP-2024-005142 · Expired

    FOR THE ERECTION OF A DOUBLE-FACE ILLUMINATED FREE-STANDING SIGN AS PER APPROVED PLANS.

  28. PermitNew Construction

    Permit MP-2024-001117 · Completed

    INSTALLATION OF NEW HVAC AND FUEL GAS PIPING SYSTEMS IN A NEW CONSTRUCTION MIXED USE BUILDING AS PER APPROVED PLANS. WORK TO INCLUDE GARAGE VENTILATION SYSTEM PER DEPARTMENT OF PUBLIC HEALTH PERMIT IP24-000091. *2018 IMC REVIEW*

  29. PermitSign

    Permit GP-2024-002366 · Completed

    FOR THE ERECTION OF ONE (1) DOUBLE-FACED PROJECTING SIGN, TWO (2) WALL SIGNS, AND TWO (2) HANGING CABINET SIGNS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  30. PermitNew construction, addition, GFA change

    Permit ZP-2024-004228 · Completed

    FOR THE INSTALLATION OF A PUBLIC ART (STATUE); SIZE AND LOCATION AS SHOWN ON PLANS.

  31. PermitNew Construction

    Permit EP-2023-009726 · Completed

    AMENDMENT: Install 1000A 480/277V Service Rated Enclosed Circuit Breaker inline with existing service conductors as per 2017 NEC. AMENDMENT: Change to layout of work area (same area/ reduction) Electrical revisions to coordinate with fixture plan and proto updates. INSTALL A 1200 AMP FEEDER FROM THE LANDLORD MSB, INSTALL A 1200AMP 277/480V/ 3 PHASE MDP. INSTALL PANELS, FEEDERS, & 400 AMP CAMLOCK GENERATOR TAP BOX. INSTALL LIGHTS NORMAL & EMERGENCY, SWITCHES, SENSORS & LIGHTNG CONTROLS. INSTALL RECEPTACLE, WIREMOLD, CONDUITS, BOXES, & PULL STRINGS FOR LOW VOLTAGE. PROVIDE POWER FOR THE MECHANICAL, HVAC, & REFRIGERATION EQUIPMENT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. ** NO FIRE ALARM WORK. **

  32. PermitNew Construction

    Permit MP-2023-004457 · Completed

    FOR THE INSTALLATION OF ONE (1) TYPE I COMMERCIAL KITCHEN HOOD AND NEW HVAC SYSTEMS, ASSOCIATED DUCT WORK, ROOFTOP UNITS, DUCTLESS SYSTEMS, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION. *AMENDMENT 11/19/24 FOR MODIFICATION TO HVAC SYSTEMS, DUCT WORK, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS.*

  33. PermitAddition and/or Alteration

    Permit CP-2023-005164 · Completed

    FOR THE INITIAL TENANT FIT-OUT. FOR USE AS A MERCANTILE OCCUPANCY (GROCERY STORE). ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. AMENDED AS OF 12/3/24: TO UPDATE THE FLOOR LAYOUT, THE FIXTURES, AND THE FINISHES, AND TO INCLUDE A NEW PARTIAL SLAB ON GRADE AND SUPPORTS FOR MECHANICAL APPLIANCES. SIZE AND LOCATION AS SHOWN IN THE AMENDED PLANS.

  34. PermitChange of Use

    Permit ZP-2024-001188 · Issued

    Retail Sales - Food, Beverages, and Groceries

  35. PermitNew Construction

    Permit FP-2023-002315 · Completed

    FOR THE INSTALLATION OF A NEW FIRE SUPPRESSION SYSTEM INCLUDING SPRINKLER DESIGNED PER NFPA 13 STANDARD AND STANDPIPES DESIGNED PER NFPA 14 STANDARDS AS PER PLANS. ALL SERVED BY A 6 INCH FIRE SERVICE LINE WITH A BACKFLOW PREVENTOR AND A FIRE PUMP AS SHOWN ON PLANS.

  36. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2023-011488 · Completed

    FOR THE ERECTION OF SIGNS ACCESSORY TO THE RESIDENTIAL & COMMERCIAL SPACES (USE REGISTRATION REQUIRED PRIOR TO OCCUPANCY) IN TWO (2) DETACHED STRUCTURES. SIZE AND LOCATION AS SHOWN IN THE PLAN/DOCUMENTS.

  37. PermitNew Construction or Additions

    Permit PP-2023-006020 · Completed

    Install of underground sanitary and storm. Install of above ground and inwall san, storm and domestic water. Install of unit plumbing fixtures and hot water heaters.

  38. PermitAddition and/or Alteration

    Permit EP-2023-007032 · Completed

    Furnish & Install 76 Category 6 Cables / Install Fiber Optic Cabling / Install Security & A/V Systems as per 2017 nec

  39. PermitAddition and/or Alteration

    Permit EP-2023-007029 · Completed

    Furnish & Install 86 Category 6 Cables / Install Fiber Optic Cabling / Install Security & A/V Systems as per 2017 nec

  40. PermitNew Construction

    Permit EP-2022-004926 · Completed

    NORTH SIDE BUILDING ELECTRICAL SERVICE AND TEMPORARY SERVICE &DEVICES . WIRING OF EM.GENERATOR W/ ATS SWITCH, WIRING OF ALL UNITS . INSTALLATION OF RESCUE ASSISTANCE SYSTEM,ALL MECHANICAL EQUIPMENT . INSTALL FIRE ALARM SYSTEM. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE. **(SEPARATE ELECTRICAL PERMITS REQ'D FOR RETAIL& AMENITY FITOUTS)**

  41. PermitNew Construction

    Permit MP-2022-003718 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  42. PermitNew Construction

    Permit FP-2022-003317 · Completed

    FOR THE INSTALLATION OF A NEW AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A SIX (6) STORY STRUCTURE WITH DRY SPRINKLER SYSTEM THROUGHOUT THE INTERIOR PARKING GARAGE IN ACCORDANCE WITH NFPA 13. FOR THE INSTALLATION OF CLASS 1 MANUAL WET STANDPIPES IN INTERIOR EXIT STAIRWAY ENCLOSURES IN ACCORDANCE WITH NFPA 14. SYSTEMS TO BE SERVED BY A SIX (6) INCH FIRE SERVICE LINE, A SIX (6) INCH BACKFLOW PREVENTION DEVICE, AND A FIRE PUMP INSTALLED IN A COMPLIANT FIRE PUMP ROOM AND IN ACCORDANCE WITH NFPA 20. ALL WORK TO BE DONE PER APPROVED PLANS BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK. SEE CP-2020-004758 FOR ASSOCIATED BUILDING PERMIT.

  43. PermitNew Construction or Additions

    Permit PP-2023-000825 · Completed

    INSTALL 224 WASHING MACHINE BOXES, 225 KITCHEN SINKS, 22 FLOOR DRAINS, 1 BASCKFLOW PREVENTER, 2 GREASE INTERCEPTOR, 3 SUMP PUMPS, 1 MOP SINK, 61 PLANTER DRAINS, 25 HOSE BIBBS, 14 INDIRECT WASTE RECEPTORS, 2 HAIR INTERCEPTORS, 104 ROOF DRAINS, 64 DECK DRAINS, 403 LAVATORIES, 317 WATER CLOSETS, 312 SHOWER/TUBS, 1 BOOSTER PUMP, 2 DOG WASHING STATIONS AND 27 TRENCH DRAINS ACCORDING TO THE 2018 PPC.

  44. PermitNew Construction or Additions

    Permit PP-2023-002071 · Completed

    Reissuance of Combo Plumbing permit PP-2020-15869 SITE PREPARATION WORK TO INCLUDE INSTALLATION OF NEW RIP RAP BULKHEADS AND PLACEMENT OF FILL ALONG WITH CONSTRUCTION OF DRIVEWAYS AND PEDESTRIAN WALKWAYS FOR FUTURE CONSTRUCTION OF MIXED USE BUILDINGS (UNDER SEPARATE PERMIT) AS PER APPROVED PLANS. WORK TO COMPLY WITH 2018 IBC AND ASCE 24-14. SOUTHERN PORTION OF BULKHEADS TO BE COMPLETED LATER UNDER A SEPARATE PERMIT. **NO BUILDING CONSTRUCTION ON THIS PERMIT AND SEPARATE PERMIT REQUIRED FOR CONSTRUCTION/INSTALLATION OF ADDITIONAL ACCESSORY STRUCTURES** **************Permit changes include the addition of (1) 4" sanitary lateral servicing a future grease interceptor. ****************

  45. PermitNew Construction

    Permit EP-2022-004925 · Completed

    ALL ELECTRICAL WORK FOR NON HI-RISE WOOD FRAME APARTMENTS/MULTI FAMILY NEW HIGH VOLTAGE DISTRUBTION BACKUP GENERATOR ENTIRE ELECTRICAL INSTALLATION THROUGHOUT BUILDING ON SOUTH SIDE AS PER 2017 NEC INSTALL FIRE ALARM AS PER 2016 NFPA 72 INCLUDES TEMPORARY WIRING

  46. PermitTank Install/Removal

    Permit GP-2022-007186 · Completed

    TANK REMOVAL PERMIT - REMOVE ONE (1) UNDERGROUND STORAGE TANKS (UST) . The removal must comply with the regulations of the Pennsylvania Department of Environmental Protection (PADEP).

  47. PermitTank Install/Removal

    Permit GP-2022-003250 · Completed

    TANK REMOVAL PERMIT - REMOVE (2) TWO UNDERGROUND STORAGE TANKS (UST) . The removal must comply with the regulations of the Pennsylvania Department of Environmental Protection (PADEP).

  48. PermitNew construction, addition, GFA change

    Permit ZP-2022-001459 · Issued

    FOR THE ERECTION OF TWO (2) DETACHED STRUCTURES (NORTH BUILDING AND SOUTH BUILDING) WITH INCREASE GROSS FLOOR AREA FROM PREVIOUSLY APPROVED ZONING PERMIT, ZP-2020-001850. SIZE AND LOCATION AS SHOWN ON PLANS. AMENDMENT (6/27/2024) TO ADD A ROOF DECK (WITH A POOL) TO THE SOUTH BUILDING. SIZE AND LOCATION AS SHOWN ON PLANS. AMENDMENT (7/16/2024) TO ADD TWO (2) ACCESSORY SURFACE PARKING SPACES. SIZE AND LOCATION AS SHOWN ON PLANS.

  49. InvestigationL&I investigation

    Case 595686 · PASSED

    The cited inspection visit was marked passed.

  50. PermitNew Construction

    Permit CP-2020-004769 · Completed

    NEW CONSTRUCTION OF A SIX (6) STORY STRUCTURE (NORTH BUILDING) TO INCLUDE VACANT COMMERCIAL SPACES (USE REGISTRATION & FIT-OUT PERMITS REQUIRED PRIOR TO OCCUPANCY), TWO HUNDRED THIRTY-EIGHT (238) DWELLING UNITS AND ACCESSORY PARKING GARAGE AS PER APPROVED PLANS. BUILDING TO UTILIZE VERTICAL AND HORIZONTAL SEPARATIONS TO CREATE THREE (3) SEPARATE BUILDINGS WITH THREE (3) DIFFERENT CONSTRUCTION TYPES (1ST FLOOR - TYPE IA, BLDG 1 2ND THROUGH 6TH FLOORS - TYPE IIIA & BLDG 2 2ND THROUGH 5TH FLOORS - TYPE VA). FIRE RETARDANT TREATED STUDS AND SHEATHING REQUIRED FOR TYPE III CONSTRUCTION. BUILDING LOCATED WITHIN THE ZONE AE SFHA AND TO INCLUDE WET FLOODPROOFING WITH FLOOD OPENINGS. ELEVATION CERTIFICATE REQUIRED TO BE SUBMITTED TO FIELD INSPECTOR UPON COMPLETION OF FIRST FLOOR. SEE SP-2020-000534 FOR SITE-WORK APPROVAL. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 AND INCLUDE STANDPIPES PER NFPA 14. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK** AMENDMENT APPROVED 11/4/22 AMEND NEW CONSTRUCTION PERMIT CP-2020-004769 FOR CHANGES TO FLOOR LAYOUTS THROUGHOUT THE BUILDING AND AN INCREASE IN TOTAL NUMBER OF UNITS TO TWO HUNDRED FORTY-SEVEN (247) DWELLING UNITS AS PER APPROVED PLANS. AMENDMENT APPROVED 6/23/23 AMEND NEW CONSTRUCTION PERMIT CP-2020-004769 TO FIT-OUT RESIDENTIAL AMENITY SPACES AS PER APPROVED PLANS.

  51. PermitNew Construction

    Permit CP-2020-004758 · Completed

    NEW CONSTRUCTION OF A SIX (6) STORY STRUCTURE (SOUTH BUILDING) TO INCLUDE VACANT COMMERCIAL SPACES (USE REGISTRATION & FIT-OUT PERMITS REQUIRED PRIOR TO OCCUPANCY), TWO HUNDRED FORTY-THREE (243) DWELLING UNITS AND ACCESSORY PARKING GARAGE AS PER APPROVED PLANS. BUILDING TO UTILIZE VERTICAL AND HORIZONTAL SEPARATIONS TO CREATE THREE (3) SEPARATE BUILDINGS WITH THREE (3) DIFFERENT CONSTRUCTION TYPES (1ST FLOOR - TYPE IA, BLDG 1 2ND THROUGH 6TH FLOORS - TYPE IIIA & BLDG 2 2ND THROUGH 5TH FLOORS - TYPE VA). FIRE RETARDANT TREATED STUDS AND SHEATHING REQUIRED FOR TYPE III CONSTRUCTION. BUILDING LOCATED WITHIN THE ZONE AE SFHA AND TO INCLUDE WET FLOODPROOFING WITH FLOOD OPENINGS. ELEVATION CERTIFICATE REQUIRED TO BE SUBMITTED TO FIELD INSPECTOR UPON COMPLETION OF FIRST FLOOR. SEE SP-2020-000534 FOR SITE-WORK APPROVAL. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 AND INCLUDE STANDPIPES PER NFPA 14. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK** AMENDMENT APPROVED 11/4/22 AMEND NEW CONSTRUCTION PERMIT CP-2020-004758 FOR CHANGES TO FLOOR LAYOUTS THROUGHOUT THE BUILDING AND A DECREASE IN TOTAL NUMBER OF UNITS TO TWO HUNDRED TWENTY-THREE (223) DWELLING UNITS AS PER APPROVED PLANS. AMENDMENT APPROVED 6/23/23 AMEND NEW CONSTRUCTION PERMIT CP-2020-004758 TO FIT-OUT RESIDENTIAL AMENITY SPACES AS PER APPROVED PLANS.

  52. ViolationPIERS & WATERFRONT STRUCTURES INSPECTION REQUIRED

    Case CF-2021-044567 · Violation VI-2021-032891 · Code PM15-314 · COMPLIED

    Resolution: COMPLIED - OWNER DEMOLITION City marked this violation complied with; check the resolution date and live case for what was accepted.

  53. InvestigationL&I investigation

    Case CF-2021-044567 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  54. PermitSitework with Onsite Utility Services

    Permit SP-2020-000534 · Completed

    SITE PREPARATION WORK TO INCLUDE INSTALLATION OF NEW RIP RAP BULKHEADS AND PLACEMENT OF FILL ALONG WITH CONSTRUCTION OF DRIVEWAYS AND PEDESTRIAN WALKWAYS FOR FUTURE CONSTRUCTION OF MIXED USE BUILDINGS (UNDER SEPARATE PERMIT) AS PER APPROVED PLANS. WORK TO COMPLY WITH 2018 IBC AND ASCE 24-14. SOUTHERN PORTION OF BULKHEADS TO BE COMPLETED LATER UNDER A SEPARATE PERMIT. **NO BUILDING CONSTRUCTION ON THIS PERMIT AND SEPARATE PERMIT REQUIRED FOR CONSTRUCTION/INSTALLATION OF ADDITIONAL ACCESSORY STRUCTURES**

  55. PermitCombined Lot Line Relocation and New Dev…

    Permit ZP-2020-001850 · Completed

    FOR THE ERECTION OF TWO (2) DETACHED STRUCTURES (NORTH BUILDING AND SOUTH BUILDING). SIZE AND LOCATION AS SHOWN ON PLANS.

  56. ViolationSECURE ELECTRICAL EQUIPMENT

    Case 595686 · Violation 211941301 · Code E-1201.1/101 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  57. ViolationGFCI RECEPTACLE REQ'D

    Case 595686 · Violation 211941302 · Code E-1201.1/203 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  58. ViolationCONNECTOR-NEEDED AT BOX

    Case 595686 · Violation 211941252 · Code E-1201.1/303 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  59. ViolationNOT CONFORM TO PRC/NEC

    Case 595686 · Violation 211941250 · Code E-1201.1/1 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  60. ViolationWIRE/EQUIP IMPROPERLY ABANDONE

    Case 595686 · Violation 211941251 · Code E-1201.1/2 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  61. ViolationSPACE ABOUT EQUIPMENT

    Case 595686 · Violation 211941254 · Code E-1201.1/105 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  62. ViolationVENTILATION OF EQUIP

    Case 595686 · Violation 211941293 · Code E-1201.1/102 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  63. ViolationBOX-NEEDED AT TERMINATION

    Case 595686 · Violation 211941294 · Code E-1201.1/302 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  64. ViolationRACEWAY-SECURE & SUPPORT

    Case 595686 · Violation 211941297 · Code E-1201.1/301 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  65. ViolationOPENING-REQ'D TO CLOSE UNUSED

    Case 595686 · Violation 211941299 · Code E-1201.1/108 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  66. ViolationWIRE/EQUIP-REPLACE DEFEC/DAMAG

    Case 595686 · Violation 211941298 · Code E-1201.1/100 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  67. ViolationGROUND-SYSTEM PROPERLY

    Case 595686 · Violation 211941300 · Code E-1201.1/229 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

Where this comes from

Methodology & freshness

This report was assembled Jul 20, 2026, 7:10 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)