801-49 Pine St

383,975 sqftRM4built 1943

Property at a glanceCommercial

Penna Hospital

2026 assessment
$32M OPA value, not a listing price
2027 published assessment
$32M Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $32,445,000. It is not yet the billed-year tax basis.

$0$25M$50M$32M2005200920132017202120252027
Property assessmentAssessmentL&I violationPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record245 events · exact dates, newest first
  1. L&I violationFACADES
  2. L&I violationFACADES
  3. InspectionL&I investigation
  4. InspectionL&I investigation
  5. PermitAlterations
  6. PermitTemporary Tents and Canopies
  7. PermitAddition and/or Alteration
  8. PermitAddition and/or Alteration
  9. PermitAddition and/or Alterations
  10. PermitAddition and/or Alteration
  11. PermitAddition and/or Alterations
  12. PermitAddition and/or Alterations
  13. PermitAlterations
  14. PermitAddition and/or Alterations
  15. PermitAddition and/or Alteration
  16. PermitAddition and/or Alterations
  17. PermitAddition and/or Alterations
  18. LicenseAramark: Food Preparing and Serving business license initially issued
  19. LicenseAramark: Food Preparing and Serving (30+ SEATS) business license initially issued
  20. PermitAddition and/or Alteration
  21. PermitAddition and/or Alterations
  22. PermitRoof Covering Replacement
  23. PermitAddition and/or Alteration
  24. PermitAddition and/or Alteration
  25. PermitAddition and/or Alterations
  26. PermitAlterations
  27. PermitAddition and/or Alterations
  28. PermitAddition and/or Alteration
  29. CertificationFire Alarm Certification
  30. PermitAddition and/or Alterations
  31. CertificationFire Alarm Certification
  32. PermitTemporary Tents and Canopies
  33. PermitTemporary Tents and Canopies
  34. PermitAddition and/or Alteration
  35. PermitAddition and/or Alteration
  36. CertificationEmergency and Standby Power Systems Certification
  37. CertificationEmergency and Standby Power Systems Certification
  38. CertificationEmergency and Standby Power Systems Certification
  39. CertificationEmergency and Standby Power Systems Certification
  40. CertificationSprinkler Certification
  41. CertificationSprinkler Certification
  42. PermitAddition and/or Alteration
  43. PermitAddition and/or Alterations
  44. PermitAddition and/or Alterations
  45. PermitAddition and/or Alteration
  46. PermitAlterations
  47. PermitAlterations
  48. PermitAddition and/or Alterations
  49. PermitAddition and/or Alteration
  50. PermitAddition and/or Alteration
  51. CertificationFire Alarm Certification
  52. PermitShelter/Platform
  53. PermitAddition and/or Alterations
  54. PermitAlterations
  55. PermitRough-In
  56. CertificationFire Alarm Certification
  57. PermitAddition and/or Alteration
  58. PermitAddition and/or Alteration
  59. LicensePENN HOSP OF UNIV OF PENN HEALTH SYSTEMS (ENGINEERING SERVICES): High Rise L&I license filing marked inactive
  60. PermitAddition and/or Alterations
  61. PermitAlterations
  62. PermitAddition and/or Alteration
  63. PermitTemporary Tents and Canopies
  64. PermitAddition and/or Alterations
  65. PermitRough-In
  66. CertificationEmergency and Standby Power Systems Certification
  67. CertificationEmergency and Standby Power Systems Certification
  68. CertificationEmergency and Standby Power Systems Certification
  69. CertificationEmergency and Standby Power Systems Certification
  70. PermitAddition and/or Alteration
  71. CertificationFire Alarm Certification
  72. PermitAddition and/or Alterations
  73. PermitTemporary Tents and Canopies
  74. PermitTemporary Tents and Canopies
  75. PermitAddition and/or Alterations
  76. PermitAddition and/or Alteration
  77. CertificationFire Alarm Certification
  78. PermitAddition and/or Alteration
  79. PermitAddition and/or Alterations
  80. PermitAlterations
  81. PermitRough-In
  82. PermitAddition and/or Alteration
  83. PermitTemporary Tents and Canopies
  84. CertificationFacade Report
  85. CertificationFacade Report
  86. CertificationFacade Report
  87. CertificationEmergency and Standby Power Systems Certification
  88. CertificationSprinkler Certification
  89. PermitAddition and/or Alterations
  90. CertificationFire Alarm Certification
  91. PermitAddition and/or Alterations
  92. PermitAddition and/or Alteration
  93. PermitTemporary Tents and Canopies
  94. PermitAlterations
  95. PermitAddition and/or Alteration
  96. PermitAddition and/or Alteration
  97. PermitTemporary Tents and Canopies
  98. PermitAddition and/or Alterations
  99. PermitAlterations
  100. InspectionL&I investigation
  101. PermitAddition and/or Alteration
  102. PermitRough-In
  103. PermitAddition and/or Alterations
  104. PermitAddition and/or Alteration
  105. PermitAddition and/or Alterations
  106. PermitAddition and/or Alterations
  107. PermitAddition and/or Alteration
  108. PermitTemporary Tents and Canopies
  109. PermitAddition and/or Alteration
  110. PermitAddition and/or Alteration
  111. PermitAlterations
  112. PermitAddition and/or Alterations
  113. PermitAddition and/or Alterations
  114. PermitAddition and/or Alteration
  115. PermitAddition and/or Alteration
  116. CertificationFacade Report
  117. PermitAddition and/or Alteration
  118. PermitInterior Non-Load-Bearing Wall Demo.
  119. PermitAddition and/or Alteration
  120. PermitAddition and/or Alteration
  121. InspectionL&I investigation
  122. L&I violationARCHITECT/ENGINEER SERVICES
  123. L&I violationUNSAFE STRUCTURE
  124. InspectionL&I investigation
  125. L&I violationELEVATOR KEYS
  126. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  127. L&I violationFIRE SAFETY/EVACUATION PLAN
  128. L&I violationFIRE ALARM TESTED/CERTIFIED
  129. L&I violationGENERAL REQ.- CITE CODE SECTIO
  130. L&I violationFIRE SUPPRESSION CERTIFICATION
  131. L&I violationHIGH RISE LICENSE REQUIRED
  132. L&I violationFIRE SYSTEMS MAINTAINED
  133. L&I violationCOMBUSTIBLE STORAGE
  134. InspectionCI INSP
  135. PermitSuppression
  136. PermitSuppression
  137. PermitSuppression
  138. PermitSuppression
  139. PermitOperations
  140. PermitSuppression
  141. PermitSuppression
  142. PermitSuppression
  143. PermitSuppression
  144. PermitSuppression
  145. PermitSuppression
  146. CertificationFacade Report
  147. PermitSuppression
  148. PermitSuppression
  149. CertificationFacade Report
  150. PermitSuppression
  151. PermitOperations
  152. PermitOperations
  153. PermitMechanical
  154. PermitPlumbing
  155. PermitElectrical
  156. PermitMechanical
  157. PermitElectrical
  158. PermitMajor alteration
  159. PermitMajor alteration
  160. PermitMechanical
  161. PermitPlumbing
  162. PermitElectrical
  163. PermitMajor alteration
  164. PermitPlumbing
  165. PermitMechanical
  166. PermitPlumbing
  167. PermitDemolition
  168. PermitMajor alteration
  169. PermitDemolition
  170. PermitPlumbing
  171. PermitPlumbing
  172. PermitMechanical
  173. PermitMechanical
  174. PermitMajor alteration
  175. PermitMajor alteration
  176. PermitDemolition
  177. PermitDemolition
  178. PermitOperations
  179. InspectionPRECOURT (likely: pre-court compliance inspection)
  180. InspectionPRECOURT (likely: pre-court compliance inspection)
  181. PermitOperations
  182. PermitAdministrative
  183. PermitOperations
  184. InspectionCI INSP
  185. InspectionCI INSP
  186. L&I violationEGRESS DOOR HI RISE OPEN
  187. L&I violationELEVATORS POST EMERGENCY SIGN
  188. L&I violationVIOL C&I MESSAGE
  189. L&I violationEGRESS LANDING SIGN IN STAIRS
  190. L&I violationEGRESS-ASSEM OCC SIGNS
  191. InspectionCI INSP
  192. CertificationFacade Report
  193. CertificationFacade Report
  194. PermitMajor alteration
  195. PermitMajor alteration
  196. LicenseCORMOCCO INC: Food Preparing and Serving business license marked inactive
  197. InspectionCI INSP
  198. CertificationFacade Report
  199. InspectionCI INSP
  200. L&I violationHAZMAT ID ENTRANCE
  201. L&I violationVIOL C&I MESSAGE
  202. L&I violationEGRESS-ASSEM OCC SIGNS
  203. L&I violationEGRESS LANDING SIGN IN STAIRS
  204. L&I violationFIRE/EVAC PLN-HI RISE-REQ¿D
  205. L&I violationELEVATOR KEY LOCATION
  206. InspectionCI INSP
  207. InspectionPRECOURT (likely: pre-court compliance inspection)
  208. InspectionPRECOURT (likely: pre-court compliance inspection)
  209. InspectionPRECOURT (likely: pre-court compliance inspection)
  210. LicensePENN HOSP OF UNIV OF PENN HEALTH SYSTEMS (ENGINEERING SERVICES): High Rise L&I license filing initially issued
  211. PermitMajor alteration
  212. InspectionCI INSP
  213. InspectionCI INSP
  214. InspectionCI INSP
  215. InspectionCI INSP
  216. InspectionCI INSP
  217. InspectionCI INSP
  218. InspectionCI INSP
  219. InspectionCI INSP
  220. InspectionCI INSP
  221. CertificationFacade Report
  222. L&I violationVIOL C&I MESSAGE
  223. L&I violationHIRISE-PAY HIRISE FEE
  224. InspectionCI INSP
  225. L&I violationVIOL C&I MESSAGE
  226. L&I violationHIRISE-PAY HIRISE FEE
  227. L&I violationVIOL C&I MESSAGE
  228. L&I violationHIRISE-PAY HIRISE FEE
  229. L&I violationEXT ADDRESS NUMBERS
  230. InspectionCI INSP
  231. InspectionCI INSP
  232. PermitMajor alteration
  233. PermitDemolition
  234. PermitPlumbing
  235. PermitMajor alteration
  236. PermitDemolition
  237. PermitPlumbing
  238. PermitOperations
  239. PermitOperations
  240. PermitMajor alteration
  241. PermitMechanical
  242. PermitMajor alteration
  243. PermitDemolition
  244. PermitMajor alteration
  245. LicenseCORMOCCO INC: Food Preparing and Serving business license initially issued

Verify the public record

$3,748/year estimated property tax

2026 taxable assessment $267,750 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $32,445,000. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 771002000
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $267,750 of $32,445,000 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

2 open violations

What it is
Commercial Health Fac Hosp Mas+Oth
Owner
Penna Hospital
$ / sq ft
$84 below the $151 median for 7,668 commercial parcels citywide
Interior area
383,975 sqft
Lot size
183,447 sqft
Built
1943
Zoning
RM4

Recorded owner

Who's behind it

Penna Hospital · corporate / LLC owner

• Tax bills mail to 800 Spruce St, Philadelphia PA, 19107

Block context

800 block of Pine St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 800 Pine St  ·  800 Pine St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
AramarkActive

Food Preparing and Serving · Initial issue date Mar 12, 2026 · Filed expiration Mar 11, 2027

AramarkActive

Food Preparing and Serving (30+ SEATS) · Initial issue date Mar 12, 2026 · Filed expiration Mar 11, 2027

CORMOCCO INCInactive

Food Preparing and Serving · Initial issue date Sep 28, 2005 · Terminal license date Dec 22, 2012

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Inferred from public records · 2025-07-28 through 2026-07-28

Food and drink at this property

1 possible-opening record signal in this 12-month window. These are classifications, not confirmed announcements.

Inference, not an opening announcement. Possible-opening classifications are inferences from public permit and license records, not confirmed opening announcements. A permit is authorization for a stated scope, not proof that work occurred or finished. A license is an L&I registration, not proof that a business is open or operating. Food and drink uses the seven exact L&I license types already used by BlockReport. The City record does not support a reliable restaurant, bar, and cafe split. License renewals do not create new events. The opening date is the earliest initial issue date for a deduped OPA parcel, normalized business identity, and license type. Sources: L&I building permits and L&I business licenses, data through Jul 28, 2026.

Open every source row 245 dated rows
  1. ViolationFACADES

    Case CF-2026-083204 · Violation VI-2026-051370 · Code PM15-315.2 · OPEN

  2. ViolationFACADES

    Case CF-2026-083214 · Violation VI-2026-051376 · Code PM15-315.2 · OPEN

  3. InvestigationL&I investigation

    Case CF-2026-083204 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  4. InvestigationL&I investigation

    Case CF-2026-083214 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  5. PermitAlterations

    Permit PP-2026-007995 · Issued

    New fixtures w piping, 1 WC 1 LAV- 3 KS ALL WORK PERFORMED PER 2018 PPC AND EZ STANDARD

  6. PermitTemporary Tents and Canopies

    Permit OP-2026-000093 · Issued

    ASSEMBLY USE TENT - LAWFUL OCCUPANCY SHALL BE AS POSTED - REMOVAL DATE ELECTRICAL PERMIT REQUIRED, UNLESS POWER IS PROVIDED THROUGH EXISTING EXTERIOR GROUND FAULT PROTECTED RECEPTACLES AND POWER CORDS ARE RATED EXTRA HEAVY DUTY WITH U. L. LABEL STATING SUCH RATING. NO COOKING OR HEATING PERMITTED WITH THIS APPROVAL. Streets Department permit is required for street closure prior to the start work if applicable.

  7. PermitAddition and/or Alteration

    Permit EP-2026-001839 · Issued

    Renovation to existing PET CT room. New Lighting, Receptacles, and New Circuiting to new Medical Equipment as per 2017 NEC. Install new fire alarm devices as per 2016 NFPA 72.

  8. PermitAddition and/or Alteration

    Permit EP-2026-002948 · Completed

    Install new Fire alarm panel, speakers and strobes .PER APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.

  9. PermitAddition and/or Alterations

    Permit MP-2026-001237 · Issued

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  10. PermitAddition and/or Alteration

    Permit EP-2026-002798 · Completed

    Replace existing lighting with new energy efficient LED lighting. Replace existing lighting control with new. Connect new HVAC equipment to existing circuits

  11. PermitAddition and/or Alterations

    Permit MP-2026-001625 · Completed

    FOR THE REPLACEMENT OF TWO (2) GRDs AND ONE (1) TOILET ROOM EXHAUST FAN AS PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2026-001399 FOR ASSOCIATED BUILDING PERMIT.

  12. PermitAddition and/or Alterations

    Permit MP-2026-001169 · Completed

    FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM TO INSTALL NEW GRDs AND ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC AND PHC AND PA DOH APPROVALS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2025-006270 FOR ASSOCIATED BUILDING PERMIT.

  13. PermitAlterations

    Permit PP-2026-003614 · Completed

    Add new sink and WC for toilet room. *WITHOUT PIPING*

  14. PermitAddition and/or Alterations

    Permit FP-2025-002266 · Issued

    FOR ALTERATIONS TO AN EXISTING AUTOMATIC SPRINKLER SYSTEM OF THE EXISTING BUILDING TO INCLUDE REPLACEMENT OF FIRE SERVICE LINE AND BACKFLOW PREVENTER. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH NFPA 13 BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. NO CHANGE TO EXISTING FIRE MAIN, PUMP AND BACKFLOW ASSEMBLY. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK.

  15. PermitAddition and/or Alteration

    Permit CP-2026-001399 · Completed

    FOR LEVEL II ALTERATIONS TO INCLUDE NEW PARTITIONS, DOORS, FIXTURES, FURNISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK.

  16. PermitAddition and/or Alterations

    Permit FP-2026-000456 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (4) sprinklers in reading room

  17. PermitAddition and/or Alterations

    Permit FP-2026-000457 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (19) sprinklers in CT/PET area

  18. License issue eventAramark: Food Preparing and Serving business license initially issued

    License 1001834 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  19. License issue eventAramark: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 1001831 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  20. PermitAddition and/or Alteration

    Permit CP-2026-000914 · Issued

    FOR LEVEL II INTERIOR ALTERATIONS ON THE SECOND FLOOR OF AN EXISTING HOSPITAL BUILDING PER APPROVED PLANS. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/ FURNISHINGS AND ACCESSIBILITY IMPROVMENTS THROUGHOUT. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. AMENDMENT APPROVED AS OF 07/01/2026: TO REVISE THE STATEMENT OF SPECIAL INSPECTIONS SCHEDULE FORM TO INCLUDE INSPECTION TYPES "FIRE RESISTANCE PENETRATIONS AND JOINTS" AND "SPRAY FIRE-RESISTANT MATERIALS AND MASTIC AND INTUMESCENT FIRE-RESISTANT COATINGS".

  21. PermitAddition and/or Alterations

    Permit FP-2026-000311 · Cancelled

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (42) sprinkler to accommodate alterations to reading room

  22. PermitRoof Covering Replacement

    Permit GM-2025-011262 · Issued

    EZ PERMIT RE-ROOFING- For the Installation of New Roof Coverings on Existing Roofs as per attached standard. Deviations from these standards require submission of construction and site plans. Replacement of sheathing in excess of 10% of roof area shall not be applicable to the EZ permit process.

  23. PermitAddition and/or Alteration

    Permit CP-2025-006270 · Completed

    FOR LEVEL II ALTERATIONS WITH NO CHANGE OF OCCUPANCY. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  24. PermitAddition and/or Alteration

    Permit EP-2025-010401 · Completed

    Furnish & install new lighting, electrical feeders & circuits associated with the new Varian unit as per 2017 NEC. Install new fire alarm devices associated with new Varian unit as per 2016 NFPA 72.

  25. PermitAddition and/or Alterations

    Permit MP-2025-005806 · Issued

    FOR THE INSTALLATION OF NEW HVAC APPLIANCES, GRDs, AND ASSOCIATED DUCTWORK AND PIPING AND FOR THE RELOCATION OF ONE (1) EXISTING APPLIANCE (VAV). ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC AND PHC AND PA DOH APPROVALS. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. SEE CP-2025-004864 FOR ASSOCIATED BUILDING PERMIT.

  26. PermitAlterations

    Permit PP-2025-014617 · Issued

    INSTALL 3 SINKS, 1 MOP SINK, 1 EYEWASH SINK AND 1 FLOOR DRAIN. ALL WORK TO BE DONE ACCORDING TO THE 2018 PPC

  27. PermitAddition and/or Alterations

    Permit FP-2025-002297 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (15) existing sprinkler heads to accommodate interior alterations

  28. PermitAddition and/or Alteration

    Permit CP-2025-004864 · Issued

    FOR LEVEL II INTERIOR ALTERATIONS TO A PORTION OF AN EXISTING HOSPITAL . ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. **ALL WORK TO BE DONE PER APPROVED PLANS AND DOH APPROVAL.** IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. **SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.** ASBESTOS REMEDIATION REQUIRED PRIOR TO START OF WORK**

  29. CertificationFire Alarm Certification

    Certification BC-2025-028907 · Certified

    Expires 2026-10-24

  30. PermitAddition and/or Alterations

    Permit FP-2025-001734 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (11) sprinklers in Bi-plane room

  31. CertificationFire Alarm Certification

    Certification BC-2025-022062 · Certified

    Expires 2026-08-15

  32. PermitTemporary Tents and Canopies

    Permit OP-2025-000208 · Expired

    C# 53246 INSTALLING 2 - TENTS ON PROPERTY

  33. PermitTemporary Tents and Canopies

    Permit OP-2025-000147 · Expired

    C#53233 INSTALLING TENTING FOR SINGLE DAY EVENT. NO TENTS ON THE PUBLIC SIDEWALK.

  34. PermitAddition and/or Alteration

    Permit EP-2025-001458 · Completed

    Install all wiring and devices for level 2 alterations . Install fire alarm devices. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.

  35. PermitAddition and/or Alteration

    Permit EP-2025-001456 · Completed

    Install wiring for devices, lighting, fire alarm for renovation of existing procedure room & lounge as per APPROVED ELECTRICAL DRAWINGS-2017 NC,2016 NFPA-72.

  36. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-009313 · Certified

    Expires 2026-03-20

  37. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-009306 · Certified

    Expires 2026-03-19

  38. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-009304 · Certified

    Expires 2026-03-18

  39. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2025-009302 · Certified

    Expires 2026-03-17

  40. CertificationSprinkler Certification

    Certification BC-2025-008042 · Certified

    Expires 2026-03-10

  41. CertificationSprinkler Certification

    Certification BC-2025-008044 · Certified

    Expires 2026-03-10

  42. PermitAddition and/or Alteration

    Permit EP-2025-001109 · Completed

    Install new fire alarm devices and connect to the existing FACP per JCI drawings and 2016 NFPA 72. Total contract value is $299,500, consisting of $266,940 for electrical and $32,560 for fire alarm. Electrical permit applied for under EP-2024-009276.

  43. PermitAddition and/or Alterations

    Permit MP-2025-000171 · Completed

    FOR THE INSTALLATION OF HVAC APPLIANCES, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS. *2018 IMC REVIEW*

  44. PermitAddition and/or Alterations

    Permit MP-2025-000338 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM WITHIN A HOSPITAL BUILDING AS PER APPROVED PLANS. *2018 IMC REVIEW*

  45. PermitAddition and/or Alteration

    Permit EP-2024-009276 · Completed

    INSTALL NEW 225 AMP MBP PANEL & FEEDER. INSTALL NEW 450 AMP RTU-1PP PANEL & FEEDER. INSTALL A NEW 1200 AMP FEEDER TO THE 1200 AMP PANEL MPA. INSTALL A NEW 400 AMP FEEDER TO THE EXISTING MCC-A. RELOCATE ATS11-2, & 112.5 KVA TRANSFORMER & EXTEND THE EXISTING FEEDERS. INSTALL (2) WALL PACK LIGHT FIXTURES. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.

  46. PermitAlterations

    Permit PP-2025-000749 · Completed

    DEMO AND INSTALLATION OF 1 SINK PER PPC.

  47. PermitAlterations

    Permit PP-2025-000264 · Completed

    Demo 1 sink and piping. Install 2 sinks, 1 scrub sink

  48. PermitAddition and/or Alterations

    Permit FP-2025-000031 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (20) sprinklers to accommodate interior alterations

  49. PermitAddition and/or Alteration

    Permit CP-2024-006279 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS (NO CHANGE IN OCCUPANCY) TO THE MULTIPURPOSE RADIOGRAPHIC PROCEDURE ROOM ON THE 2ND FLOOR OF AN EXITING HOSPITAL. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. WORK TO BE PERFORMED PER APPROVED PLANS AND DOH APPROVAL. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  50. PermitAddition and/or Alteration

    Permit CP-2024-006408 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO THE SECOND FLOOR OF AN EXISTING HOSPITAL BUILDING (CATHCART BUILDING) AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  51. CertificationFire Alarm Certification

    Certification BC-2024-030592 · Certified

    Expires 2025-11-07

  52. PermitShelter/Platform

    Permit GP-2024-008845 · Issued

    SHELTER PLATFORM PERMIT- Erection of a sidewalk shelter platform as per Engineered Plans. Streets Department AND PHILADELPHIA HISTORICAL APPROVAL***

  53. PermitAddition and/or Alterations

    Permit MP-2024-004553 · Issued

    Install new roof top AHU and associated piping and ductwork as per approved plans.

  54. PermitAlterations

    Permit PP-2024-013715 · Expired

    FIXTURE REPLACEMENT WITHOUT PIPING (8) existing roof drains

  55. PermitRough-In

    Permit EP-2024-009277 · Completed

    Rough-In Permit for EP-2024-009276 Install Switchboards and panels to refeed existing MCC and new RTU-1 on Roof. Relocate misc. mechanical equipment, power and connections to pumps and heat trace panel. This Permit is for Phase (1) one only. Total contract value is $299,500, consisting of $266,940 for electrical and $32,560 for fire alarm. We will apply for a separate fire alarm permit on a later date.

  56. CertificationFire Alarm Certification

    Certification BC-2024-022761 · Certified

    Expires 2025-08-09

  57. PermitAddition and/or Alteration

    Permit CP-2024-003279 · Issued

    For the Construction of structural framing for AHU to include Cathcart AHU Replacement work, and roofing work to be performed in the Penthouse and Roof of the Cathcart Building. AMENDMENT: Change to roofing system as shown on attached drawings and resulting changes to the Statement of Special Inspections Schedule to remove Reinforced Concrete Special Inspections as they are no longer required.

  58. PermitAddition and/or Alteration

    Permit EP-2024-003115 · Completed

    Install new distribution for HVAC and Procedure equipment. Final power connections to CT and AHU's. New Light fixtures w/ local auto controls. New HG receptacles fed from existing normal and emergency panels. Voice/ data boxes and raceway. Power and raceway for Siemens CT equipment. Extend existing nurse call into space and add devices. Security raceway. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.

  59. License terminal eventPENN HOSP OF UNIV OF PENN HEALTH SYSTEMS (ENGINEERING SERVICES): High Rise L&I license filing marked inactive

    License 536490 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  60. PermitAddition and/or Alterations

    Permit MP-2024-002385 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  61. PermitAlterations

    Permit PP-2024-007363 · Completed

    INSTALL 3 SINKS, 3 FLOOR DRAINS, 2 WATER CLOSETS AND 3 LAVATORIES ACCORDING TO THE 2018 PPC AND PER PLANS,

  62. PermitAddition and/or Alteration

    Permit EP-2024-004321 · Completed

    INSTALL ADDITIONAL FIRE ALARM DEVICES ON THE EXISTING FIRE ALARM SYSTEM. ALL WORK IN ACCORDANCE WITH THE 2017 NEC.

  63. PermitTemporary Tents and Canopies

    Permit OP-2024-000151 · Expired

    C#48211 INSTALLING ENCLOSED 30X60 TENT FOR 1 DAY EVENT

  64. PermitAddition and/or Alterations

    Permit FP-2024-000908 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (36) sprinkler heads to accommodate interior alterations

  65. PermitRough-In

    Permit EP-2024-003118 · Completed

    Rough-In Permit for EP-2024-003115

  66. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017768 · Certified

    Expires 2025-03-28

  67. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017767 · Certified

    Expires 2025-03-27

  68. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017766 · Certified

    Expires 2025-03-26

  69. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-017765 · Certified

    Expires 2025-03-25

  70. PermitAddition and/or Alteration

    Permit CP-2024-000831 · Completed

    FOR LEVEL 2 ALTERATION TO THE 5TH FLOOR OF THE EXISTING STRUCTURE AS PER PLANS. NO CHANGE IN OCCUPANCY CLASSIFICATION. AMENDMENT (6/27/2024) TO CORRECT THE PERMIT LANGUAGE AS FOLLOWS: FOR LEVEL 2 ALTERATTIONS TO THE FIRST, SECOND AND THIRD FLOOR OF THE CATHCART BUILDING AS PER PLANS. NO CHANGE IN OCCUPANCY CLASSIFICATION. SEPARATE PERMITS REQUIRED FOR ALL MECHAICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK. Amendment for Revision of the Schedule of Special Inspections to remove Post-Installed Concrete Anchor Installation and add Spray Fire-Resistant Materials and Fire-Resistant Penetrations and Joints.

  71. CertificationFire Alarm Certification

    Certification BC-2023-023019 · Certified

    Expires 2024-10-27

  72. PermitAddition and/or Alterations

    Permit FP-2023-002184 · Completed

    FOR THE INSTALLATION OF 19 NEW CONCEALED PENDENT SPRINKLERS COMPLYING WITH NFPA 13 TO AN EXISTING FIRE SUPPRESSION SYSTEM WITH AN EXISTING FIRE PUMP AND EXISTING 6" AMES COLT 200 BACKFLOW PREVENTION ASSEMBLY LOCATED IN FIRE PUMP ROOM AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPROVED PLANS/HYDRAULIC CALCULATIONS.

  73. PermitTemporary Tents and Canopies

    Permit OP-2023-000438 · Expired

    C# 45738 INSTALLING ENCLOSED 30X60 TENT IN COURT YARD AS PER 2018 PHILADELPHIA FIRE CODE.

  74. PermitTemporary Tents and Canopies

    Permit OP-2023-000379 · Expired

    C#44790 INSTALLING ENCLOSED 30X60 TENT

  75. PermitAddition and/or Alterations

    Permit FP-2023-002088 · Completed

    Relocate (3) sprinkler heads to accommodate interior alterations in outpatient pharmacy area as per EZ PERMIT SPRINKLER RELOCATION (NFPA 13)

  76. PermitAddition and/or Alteration

    Permit EP-2023-006734 · Completed

    INSTALL (2) NEW FIRE ALARM STROBES TO THE EXISITING STROBE CIRCUIT, INSTALL (1) CONTROL MODULE FOR THE DOOR SECURITY. ALL WORK IN ACCORDANCE WITH THE 2017 NEC & 2016 NFPA-72.

  77. CertificationFire Alarm Certification

    Certification BC-2023-017155 · Certified

    Expires 2024-08-11

  78. PermitAddition and/or Alteration

    Permit EP-2023-006330 · Completed

    INSTALL NEW LIGHTS NORMAL & EMERGENCY, SWITCHES, & SENSORS FED FROM THE EXISTING CIRCUITS. INSTALL RECEPTACLES FED FROM THE EXISTING CIRCUITS. PROVIDE CONDUITS & BOXES FOR THE LOW VOLTAGE WIRING. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. * THE ELECTRIC PANELS ARE EXISTING. ** THE FIRE ALARM WORK WILL BE ADDED AT A LATER DATE.

  79. PermitAddition and/or Alterations

    Permit MP-2023-003163 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE RENOVATIONS TO PHARMACY WITHIN AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS. *2018 IMC REVIEW* **SEPARATE PERMITS REQUIRED FOR PLUMBING AND FIRE SUPPRESSION WORK**

  80. PermitAlterations

    Permit PP-2023-009984 · Completed

    Install new Hand sink with sanitary waste, vent, and domestic water

  81. PermitRough-In

    Permit EP-2023-006331 · Completed

    Rough-In Permit for EP-2023-006330 Install new receptacles, fed from existing panel board. New light fixtures w/ local controls. Raceway for tele/ data. Install security wiring and devices. Electrical cost of work $87,244; Fire Alarm cost of work $18,028 ** Will apply for a fire alarm permit at a later date** as per 2017 nec

  82. PermitAddition and/or Alteration

    Permit CP-2023-003235 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO THE PRESTON BUILDING LEVEL 1 & 2 OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  83. PermitTemporary Tents and Canopies

    Permit OP-2023-000252 · Expired

    Pennsylvania Hospital Elm Garden event As per 2018 Philadelphia Fire Code c#43678

  84. CertificationFacade Report

    Certification BC-2023-023247 · Safe with Repair

    Expires 2028-05-19

  85. CertificationFacade Report

    Certification BC-2023-023241 · Safe with Repair

    Expires 2028-03-24

  86. CertificationFacade Report

    Certification BC-2023-023243 · Safe with Repair

    Expires 2028-03-24

  87. CertificationEmergency and Standby Power Systems Certification

    Certification BC-2024-013337 · Certified

    Expires 2024-03-23

  88. CertificationSprinkler Certification

    Certification BC-2024-010772 · Certified

    Expires 2024-02-15

  89. PermitAddition and/or Alterations

    Permit MP-2022-005520 · Completed

    For alterations to an existing HVAC mechanical system to install one (1) register/diffuser within a new Environmental Services closet in the PETU on the 3rd floor of the Pennsylvania Hospital, as per plans, PHC approval dated 11/4/2022, and PA DOH approval dated 9/22/2022; see CP-2022-005571 for associated building permit; no other work to the HVAC system on this permit.

  90. CertificationFire Alarm Certification

    Certification BC-2023-004387 · Certified

    Expires 2023-10-31

  91. PermitAddition and/or Alterations

    Permit FP-2022-002878 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Modifying 1 sprinkler

  92. PermitAddition and/or Alteration

    Permit EP-2022-010483 · Completed

    Install new OCC sensor, light fixture & HG GFI receptacle as per 2017 NEC. Work in highlighted area only. This work is a change order to original contract.

  93. PermitTemporary Tents and Canopies

    Permit OP-2022-000582 · Expired

    15x30 Tent as per 2018 Philadelphia Fire Code.

  94. PermitAlterations

    Permit PP-2022-014722 · Completed

    Install sanitary waste and vent piping Install domestic hot and cold water piping Install 1 new fixture

  95. PermitAddition and/or Alteration

    Permit CP-2022-005571 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS( NO CHANGE IN OCCUPANCY) TO THE THIRD FLOOR OF AN EXITING HOSPITAL. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. WORK TO BE PERFORMED PER APPROVED PLANS AND DOH APPROVAL. BUILDING IS FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  96. PermitAddition and/or Alteration

    Permit EP-2022-003875 · Completed

    Add fire alarm devices to existing panel per Engineered drawings and 2016 NFPA 72.

  97. PermitTemporary Tents and Canopies

    Permit OP-2022-000242 · Expired

    40x80 Tent at Pennsylvania Hospital Pine Building c#38797 as per 2019 Philadelphia Fire Code.

  98. PermitAddition and/or Alterations

    Permit FP-2022-001353 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATING ONLY. NO EXTENSION OF AN EXITING SYSTEM AND NO NEW MAIN RUNS. AS PER EZ STANDARD ONLY.

  99. PermitAlterations

    Permit PP-2022-004942 · Completed

    As per submitted plan

  100. InvestigationL&I investigation

    Case 724983 · PASSED

    The cited inspection visit was marked passed.

  101. PermitAddition and/or Alteration

    Permit EP-2022-001805 · Completed

    Replace existing panel board. Install new circuits to renovated Staff Area. New light fixtures with local controls. Connect new nurse call devices to existing system. Install boxes/ raceway for voice/ data and security. Final power connections to HVAC as per 2017 NEC. Contract combines both electrical and fire alarm work. Electrical value is $157,300. Fire alarm value is $50,691. Will apply for fire alarm portion on a later date. Location: 801 Pine St AKA 800 Spruce

  102. PermitRough-In

    Permit EP-2022-001810 · Completed

    Rough-In Permit for EP-2022-001805 Replace existing panel board. Install new circuits to renovated Staff Area. New light fixtures with local controls. Connect new nurse call devices to existing system. Install boxes/ raceway for voice/ data and security. Final power connections to HVAC. Contract combines both electrical and fire alarm work. Electrical value is $157,300. Fire alarm value is $50,691. Will apply for fire alarm portion on a later date. Location: 801 Pine St AKA 800 Spruce

  103. PermitAddition and/or Alterations

    Permit MP-2022-001107 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE RENOVATIONS TO THE THIRD FLOOR OF AN EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS. *2018 IMC REVIEW*

  104. PermitAddition and/or Alteration

    Permit CP-2022-000665 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO THIRD FLOOR OF EXISTING HOSPITAL BUILDING AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK** AMENDMENT APPROVED 3/16/22 AMEND ALTERATIONS PERMIT CP-2022-000665 FOR CHANGES TO LAYOUT AS PER APPROVED PLANS.

  105. PermitAddition and/or Alterations

    Permit FP-2021-002869 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (8) sprinklers at PA Hospital, 2 Scheidt, 2nd floor. (CP-2021-003647)

  106. PermitAddition and/or Alterations

    Permit FP-2021-002870 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (35) sprinklers heads at PA Hospital, Cathcart basement (CP-2021-002953)

  107. PermitAddition and/or Alteration

    Permit EP-2021-009997 · Completed

    Install and connect 1 smoke detector, 1 duct detector and 1 control module to existing addressable fire alarm System .ALL WORK WILL BE DONE ACCORDING TO APPROVED DRAWINGS-2018 PHILA FIRE CODE,2017 NEC,2016 NFPA-72.

  108. PermitTemporary Tents and Canopies

    Permit OP-2021-000650 · Expired

    Install a 50'x100' white top tent with white and clear sidewalls secured by stakes. Install a 20'x20' tent with white sidewalls secured by stakes as per 2018 Philadelphia Fire Department. No tents to be erected on the sidewalk.

  109. PermitAddition and/or Alteration

    Permit EP-2021-008463 · Completed

    Install equipment feeder from existing Substation. Final power connections to Phillips equipment. Install 16 downlights, 4 under cabinet lights and 4 dimmers. Install 2 receptacles and O2 monitor with remote horn/ strobe. Emergency power connection to the medical gas alarm panel. Install Phillips wall duct, junction boxes and raceway. Power connections to HVAC equipment as per 2017 NEC. *We will apply for a separate fire alarm permit.*

  110. PermitAddition and/or Alteration

    Permit EP-2021-007145 · Completed

    17 new receptacles from existing panel board. 20 new light fixture with local controls. Power and final connections to HVAC equipment. Install conduit for low voltage, wire by others. Install wire for security, devices by others. Add fire alarm devices to existing system. ALL WORK TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC ,2016 NFPA-72 and 2018 PHILA FIRE CODE.

  111. PermitAlterations

    Permit PP-2021-013732 · Completed

    ONE FIXTURE REPLACEMENT NO PIPING

  112. PermitAddition and/or Alterations

    Permit MP-2021-005007 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE EQUIPMENT REPLACEMENT ON THE 2ND FLOOR OF AN EXISTING HOSPITAL BUILDING (SCHIEDT BLDG) AS PER APPROVED PLANS. *2018 IMC REVIEW*

  113. PermitAddition and/or Alterations

    Permit MP-2021-003937 · Completed

    ALTERATIONS TO EXISTING HVAC SYSTEM TO ACCOMODATE NEW LAYOUT IN BASEMENT LEVEL OF AN EXISTING HOSPITAL (CATHCART BLDG) AS PER APPROVED PLANS. *2018 IMC REVIEW*

  114. PermitAddition and/or Alteration

    Permit CP-2021-002953 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO BASEMENT LEVEL OF AN EXISTING HOSPITAL BUILDING (CATHCART) AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  115. PermitAddition and/or Alteration

    Permit CP-2021-003647 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO 2ND FLOOR OF AN EXISTING HOSPITAL BUILDING (SCHIEDT BLDG) AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  116. CertificationFacade Report

    Certification BC-2021-002044 · Safe with Repair

    Expires 2026-06-15

  117. PermitAddition and/or Alteration

    Permit EP-2021-002126 · Completed

    Install fire alarm devices and wiring per APPROVED DRAWINGS 2017 NEC and 2018 PHILA FIRE CODE.

  118. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2021-003921 · Expired

    EZ INTERIOR DEMOLITION- **Existing Philadelphia Historic Property**For the interior demolition of non-bearing partition walls and ceiling in accordance with the attached EZ Permit Interior Demolition Standard. Failure to comply with the attached EZ Permit Interior Demolition Standard shall result in revocation of this permit. No exterior work permitted as part of this permit as per PHC. Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  119. PermitAddition and/or Alteration

    Permit CP-2020-007291 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) FOR RENOVATIONS TO SECOND FLOOR LEVEL OF AN EXISTING HOSPITAL BUILDING (PRESTON BLDG) AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  120. PermitAddition and/or Alteration

    Permit CP-2020-007310 · Completed

    No change in use and occupancy classification. Interior alterations as per approved plans. All work shall be in accordance with DOH approval. Separate permit required for MEP and fire suppression work.

  121. InvestigationL&I investigation

    Case CF-2020-024783 · PASSED

    The cited inspection visit was marked passed.

  122. ViolationARCHITECT/ENGINEER SERVICES

    Case CF-2020-024783 · Violation VI-2020-009675 · Code A-304.1/1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  123. ViolationUNSAFE STRUCTURE

    Case CF-2020-024783 · Violation VI-2020-009674 · Code PM15-108.1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  124. InvestigationL&I investigation

    Case CF-2020-024783 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  125. ViolationELEVATOR KEYS

    Case 724983 · Violation 5322734 · Code FC-13-607.4 · CLOSED

    City marked the record closed; open the case for the closing reason.

  126. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 724983 · Violation 211992060 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  127. ViolationFIRE SAFETY/EVACUATION PLAN

    Case 724983 · Violation 211992058 · Code FC-13-404.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  128. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 724983 · Violation 211992056 · Code FC-13-915.1 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  129. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 724983 · Violation 211992055 · Code FC-13-316 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  130. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 724983 · Violation 211992053 · Code FC-13-915.1A · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  131. ViolationHIGH RISE LICENSE REQUIRED

    Case 724983 · Violation 211992017 · Code FC-13-408.12 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  132. ViolationFIRE SYSTEMS MAINTAINED

    Case 724983 · Violation 211992016 · Code FC-13-901.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  133. ViolationCOMBUSTIBLE STORAGE

    Case 724983 · Violation 211992015 · Code FC-13-315 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  134. InvestigationCI INSP

    Case 724983 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  135. PermitSuppression

    Permit 907183 · COMPLETED

    FOR THE EXTENSION OF A PREVIOUSLY APPROVED NFPA 13 SYSTEM TO THE 3RD FLOOR (SPRUCE BLDG, SPINE CENTER) OF AN EXISTING HEALTH FACILITY, AS PER APPROVED PLANS. FIRE SUPPRESSION SYSTEM SERVICED BY AN EXISTING FIRE SERVICE LINE WITH AN EXISTING BACK FLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13 STANDARD.

  136. PermitSuppression

    Permit 919816 · COMPLETED

    FOR THE EXTENSION OF A PREVIOUSLY APPROVED NFPA 13 SYSTEM TO THE 8TH FLOOR (SPRUCE BLDG, SPINE CENTER) OF AN EXISTING HEALTH FACILITY, AS PER APPROVED PLANS. FIRE SUPPRESSION SYSTEM SERVICED BY AN EXISTING FIRE SERVICE LINE WITH AN EXISTING BACK FLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 13 STANDARD.

  137. PermitSuppression

    Permit 907049 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  138. PermitSuppression

    Permit 867058 · COMPLETED

    FOR THE EXTENSION OF A PREVIOUSLY APPROVED NFPA 13 SYSTEM TO THE 9TH FLOOR OF AN EXISTING HEALTH FACILITY, FIRE SUPPRESSION SYSTEM SERVICED BY AN EXISTING FIRE SERVICE LINE WITH AN EXISTING BACK FLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK. FIRE SUPPRESSION SYSTEM TO BE INSTALLED IN ACCORDANCE WITH A NFPA 13 STANDARD.

  139. PermitOperations

    Permit 25661 · COMPLETED

    6/8/2018 ERECT ONE (1) TENT 40X90

  140. PermitSuppression

    Permit 841095 · COMPLETED

    FOR THE INSTALLATION OF AN AUTOMATIC FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 THROUGHOUT SECOND FLOOR OF THE PINE BUILDING AS PER APPROVED PLANS. SPRINKLER SYSTEM TO TIE INTO BUILDING'S EXISTING SPRINKLER SYSTEM. ASBESTOS REMOVAL REQUIRED PRIOR TO COMMENCING WORK FROM LOCATION INDICATED ON THE ASBESTOS INSPECTION REPORT.

  141. PermitSuppression

    Permit 841100 · COMPLETED

    FOR THE INSTALLATION OF TWO HUNDRED TWENTY-TWO (222) SPRINKLER HEADS ON THE THIRD AND FOURTH FLOOR OF AN EXISTING HOSPITAL BUILDING. SYSTEM TO UTILIZE EXISTING 6" BACKFLOW ASSEMBLY AND 6" FIRE SERVICE MAIN LINE AS PER PLANS

  142. PermitSuppression

    Permit 848129 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  143. PermitSuppression

    Permit 839403 · COMPLETED

    WE WILL BE RELOCATING (33) SPRINKLER IN THE 2ND FLOOR OF THE SCHEIDT BUILDING EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  144. PermitSuppression

    Permit 790649 · COMPLETED

    FOR THE INSTALLATION OF ONE HUNDRED SEVENTY-SEVEN (177) SPRINKLER HEADS ON THE FIRST FLOOR OF AN EXISTING HOSPITAL. SYSTEM TO UTILIZE EXISTING 6" BACKFLOW ASSEMBLY AND 6" FIRE SERVICE MAIN LINE.

  145. PermitSuppression

    Permit 778432 · COMPLETED

    THIS IS AN OVER THE COUNTER PERMIT APPLICATION. WE WILL BE RELOCATING (45) SPRINKLERS IN THE SURGICAL FAMILY WAITING ROOM ON THE FIRST FLOOR OF THE CATHART BUILDING.

  146. CertificationFacade Report

    Certification BC-2022-004422 · Safe with Repair

    Expires 2022-04-12

  147. PermitSuppression

    Permit 769540 · COMPLETED

    INSTALLATION OF BRANCH LINES AND SPRINKLERS OFF OF EXISTING MAIN LINES FOR NEW LIN-AC VAULT IN ACCORDANCE WITH THE NFPA 13 STANDARD AND AS PER APPROVED PLANS. NO WORK TO EXISTING PUMP(S), BACKFLOW PREVENTION ASSEMBLY OR MAIN FEEDS.

  148. PermitSuppression

    Permit 772600 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  149. CertificationFacade Report

    Certification BC-2022-004420 · Safe with Repair

    Expires 2022-01-27

  150. PermitSuppression

    Permit 694962 · COMPLETED

    ALTERATIONS TO EXISTING FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH THE NFPA 13 STANDARD TO INCLUDE INSTALLING (56) NEW SPRINKLERS AND ASSOCIATED PIPING IN 2ND FLOOR CATHCART WOMEN'S IMAGING SUITE AS PER APPROVED PLANS. NO WORK TO EXISTING FIRE SERVICE OR EXISTING BACKFLOW PREVENTION ASSEMBLY.

  151. PermitOperations

    Permit 24133 · COMPLETED

    4/22/16 ERECT ASSEMBLY TENT 40X40

  152. PermitOperations

    Permit 23959 · COMPLETED

    12/1/15 ERECT EXHIBIT TENT (40'X 40') AT PENNSYLVANIA HOSPITAL

  153. PermitMechanical

    Permit 656360 · COMPLETED

    MECHANICAL RENOVATIONS INCLUDING EQUIPMENT AND MECHANICAL PIPING INSTALLATION TO STORAGE, CALL ROOMS, NURSES STATION INTO 3 EXAM ROOMS, WAITING AREA, REVIEW ROOM AND OFFICE

  154. PermitPlumbing

    Permit 657620 · COMPLETED

    NEW DRAIN, VENTING AND WATER FOR 3- SINKS, CONNECT TO EXISTING MAINS

  155. PermitElectrical

    Permit 645803 · COMPLETED

    ADDITIONAL RECEPTACLES, LIGHTING AND NURSE CALL FOR HEAT STATION. RELOCATION OF 120V PANEL AS PER NEC 2008 CC DISTRICT

  156. PermitMechanical

    Permit 645029 · COMPLETED

    MECHANICAL PIPING AND EQUIPMENT INSTALLATION

  157. PermitElectrical

    Permit 642880 · COMPLETED

    NEW 40 AMP FEED TO MEDICAL EQUIPMENT. THE EXISTING CEILING IS TO BE LOWERED. EXISTING LIGHTS SHALL BE REMOVED AND REINSTALLED. ONE NEW POWER RECEPTACLE SHALL BE INSTALLED PER 2008 NEC (HEALTH CARE)

  158. PermitMajor alteration

    Permit 641656 · COMPLETED

    LEVEL II ALTERATION INCLUDE RENOVATING EXISTING STORAGE ROOMS, ON CALL ROOMS AND A NURSES STATION INTO (3) EXAM ROOMS, A WAITING AREA, A REVIEW ROOM AND A TOUCHDOWN OFFICE.**SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK**

  159. PermitMajor alteration

    Permit 636706 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO CONVERT AN X-RAY SCAN ROOM TO A MAMMOGRAPHY SCAN ROOM ON THE FIRST FLOOR OF AN EXISTING HOSPITAL BUILDING (CATHCART) AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  160. PermitMechanical

    Permit 623194 · COMPLETED

    FOR INTERIOR MECHANICAL DEMOLITION AND FOR THE INSTALLATION OF AN HVAC SYSTEM TO INCLUDE REGISTERS/DIFFUSERS, DUCTWORK, VAVS, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  161. PermitPlumbing

    Permit 623162 · COMPLETED

    PLUMBING RENOVATION INCLUDING PIPING & FIXTURES INSTALLATION THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  162. PermitElectrical

    Permit 621473 · COMPLETED

    INSTALL 2-NEW PANEL, NEW GENERAL POWER & LIGHTING & ASSOCIATED WORK REQUIRED FOR VARIOUS LAB EQUIPMENT & NEW NURSE CALL DEVICES INSTALLED AS PER NEC 2008 & INSTALL FIRE ALARM AS PER NFPA 72

  163. PermitMajor alteration

    Permit 617426 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO E.P. LAB AND SURGICAL SUITE ON THE THIRD FLOOR OF AN EXISTING HOSPITAL AS PER APPROVED PLANS AND PA DOH APPROVAL. EXISTING BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK**

  164. PermitPlumbing

    Permit 611135 · COMPLETED

    REPLACE SECTION OF DRAIN LINE AND RE-ROUTE AROUND NEW MRI

  165. PermitMechanical

    Permit 588264 · COMPLETED

    INSTALL DUCTWORK, MECHANICALS, REGISTERS DIFFUSERS PIPING, INCIDENTALS.

  166. PermitPlumbing

    Permit 587098 · COMPLETED

    INSTALLATION OF 2 SINKS AND 1 DRAIN

  167. PermitDemolition

    Permit 585530 · COMPLETED

    INTERIOR DEMO NON LOAD BEARING

  168. PermitMajor alteration

    Permit 582732 · COMPLETED

    FOR INTERIOR NON-BEARING PARTITION WALL DEMOLITION, AND INSTALLATION OF NEW PARTITION WALLS, AND NEW WALL/FLOOR/CEILING FINISHING AS PER PLANS APPROVED BY HISTORICAL COMMISSION. (IEBC 2009, COMPLIANCE PATH--WORK AREA METHOD: LVL II ALTERATIONS) **ASBESTOS ABATEMENT TO BE COMPLETED PRIOR TO COMMENCEMENT OF ALTERATION WORK.** SEPARATE PERMITS TO BE REQUIRED FOR MECHANICAL, FIRE SUPPRESSION, ELECTRICAL AND PLUMBING ALTERATIONS.

  169. PermitDemolition

    Permit 579886 · COMPLETED

    3,100 SQUARE FEET, INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILINGS ONLY. NO OTHER WORK ALLOWED UNDER THIS PERMIT. SEPARATE PERMITS REQUIRED FOR RENOVATION NO STRUCTURAL CHANGES. MUST MAINTAIN ALL CODE REQUIRED FIRE RATING ON WALL AND FLOOR/CEILING ASSEMBLIES CALL INSPECTOR PRIOR FOR INITIAL INSPECTION PRIOR TO THE START OF WORK

  170. PermitPlumbing

    Permit 576862 · COMPLETED

    REPLACEMENT ONLY: 1- WATER CLOSET, 1- LAVATORY, 4- SINKS WITH1-1/2" TRAPS

  171. PermitPlumbing

    Permit 577671 · COMPLETED

    1-TOILET & LAV, 1-FLOOR DRAIN W/TRAP PRIMER, 1-CLINICAL SERV SINK, 1-MOP SINK & 5-HAND SINKS W/1 1/2" P TRAPS (HOSPITAL) NOTE: THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  172. PermitMechanical

    Permit 574636 · COMPLETED

    MECHANICAL RENOVATIONS TO THE MRI SUITE/BASEMENT & 1ST FL INCLUDING INSTALLATION OF DUCTWORK AND MECHANICAL EQUIPMENT

  173. PermitMechanical

    Permit 574649 · COMPLETED

    MECHANICAL RENOVATIONS TO THE IR SUITE ON THE 2ND FL INCLUDING INSTALLATION OF DUCTWORK AND MECHANICAL EQUIPMENT

  174. PermitMajor alteration

    Permit 568487 · COMPLETED

    INTERIOR RENOVATIONS TO THE IR SUITE ON THE 2ND FLOOR AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING.

  175. PermitMajor alteration

    Permit 569721 · COMPLETED

    INTERIOR ALTERATIONS ONLY, AS INDICATED PER PLANS. GENERAL INTERIOR DEMO, RENOVATIONS, PARTITIONS, CASEWORK, ACCESSIBILITY UPGRADES,FINISHES. ADDITIONAL PERMITS REQ; ELECTRICAL, PLUMBING, HVAC, SPRINKLERS. NO WORK TO EXTERIOR, NO ALTERATIONS TO EXTERIOR WINDOWS/DOORS PER PHC. NO CHANGE IN USE-OCCUPANCY

  176. PermitDemolition

    Permit 569715 · COMPLETED

    INTERIOR DEMOLITION OF NON LOAD BEARING WALLS AND CEILING ONLY. NO OTHER WORK ALLOWED UNDER THIS PERMIT. CONTACT STREETS DEPARTMENT FOR DUMPSTER PERMIT AND FOOTWAY CLOSURE.

  177. PermitDemolition

    Permit 567210 · COMPLETED

    REMOVAL OF EXISTING WALLS, PARTITIONS, EQUIPMENT, FLOORING IN PREPARATION FOR RENOVATION OF SPACE. INTERIOR DEMOLITION.

  178. PermitOperations

    Permit 23198 · COMPLETED

    10/08/2014 ERECT ASSEMBLY TENTS (30X30) (40X50) PENNSYLVANIA HOSPITAL "GOOD SAMARITAN DAY"

  179. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 411576 · NONE

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file.

  180. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 411576 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  181. PermitOperations

    Permit 22946 · COMPLETED

    06/02/2014 ERECT ASSEMBLY TENT (40'X50')FOR PENNSYLVANIA HOSPITAL PARTY

  182. PermitAdministrative

    Permit 539031 · COMPLETED

    LAWFUL OCCUPANCY SIGN FOR FOR PRESTON - 1ST FLOOR - ZUBROW AUDITORIUM AS PER PLANS. NO WORK ON THIS APPLICATION.

  183. PermitOperations

    Permit 22871 · COMPLETED

    05/13/2014 ERECT ASSEMBLY TENTS (30'X30') (40'X50') AT PENNSYLVANIA HOSPITAL

  184. InvestigationCI INSP

    Case 411576 · CLOSED

    City marked the record closed; open the case for the closing reason.

  185. InvestigationCI INSP

    Case 411576 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  186. ViolationEGRESS DOOR HI RISE OPEN

    Case 411576 · Violation 3143395 · Code FC-1008.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  187. ViolationELEVATORS POST EMERGENCY SIGN

    Case 411576 · Violation 3143399 · Code FC-607.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  188. ViolationVIOL C&I MESSAGE

    Case 411576 · Violation 3143393 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  189. ViolationEGRESS LANDING SIGN IN STAIRS

    Case 411576 · Violation 3143396 · Code FC-1019.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  190. ViolationEGRESS-ASSEM OCC SIGNS

    Case 411576 · Violation 3143394 · Code FC-1004.3/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  191. InvestigationCI INSP

    Case 411576 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  192. CertificationFacade Report

    Certification BC-2022-011724 · Safe with Repair

    Expires 2018-09-23

  193. CertificationFacade Report

    Certification BC-2022-011726 · Safe with Repair

    Expires 2018-09-19

  194. PermitMajor alteration

    Permit 480253 · COMPLETED

    RENOVATION OF OF EXISTING SPACE TO UPDATE PATIENT INTAKE AND EXAM ROOMS AS WELL AS MEDICAL OFFICES SPACES.

  195. PermitMajor alteration

    Permit 458053 · COMPLETED

    REMOVAL AND REPLACMENT OF EXISTING SLATE ROOFING AND FLASHINGS. MASONRY CONSILIDATION AND POINTING TO LIMIT AREAS OF THE FACADE. POINTING SAMPLES TO BE APPROVED BY HISTORIC.

  196. License terminal eventCORMOCCO INC: Food Preparing and Serving business license marked inactive

    License 338950 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  197. InvestigationCI INSP

    Case 329147 · PASSED

    The cited inspection visit was marked passed.

  198. CertificationFacade Report

    Certification BC-2022-009631 · Safe with Repair

    Expires 2017-08-02

  199. InvestigationCI INSP

    Case 329147 · PASSED

    The cited inspection visit was marked passed.

  200. ViolationHAZMAT ID ENTRANCE

    Case 329147 · Violation 2448096 · Code FC-2703.5/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  201. ViolationVIOL C&I MESSAGE

    Case 329147 · Violation 2448093 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  202. ViolationEGRESS-ASSEM OCC SIGNS

    Case 329147 · Violation 2448094 · Code FC-1004.3/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  203. ViolationEGRESS LANDING SIGN IN STAIRS

    Case 329147 · Violation 2448095 · Code FC-1019.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  204. ViolationFIRE/EVAC PLN-HI RISE-REQ¿D

    Case 329147 · Violation 2448097 · Code FC-404.2/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  205. ViolationELEVATOR KEY LOCATION

    Case 329147 · Violation 2448098 · Code FC-607.3/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  206. InvestigationCI INSP

    Case 329147 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  207. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 274324 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  208. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 274294 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  209. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 274829 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  210. License issue eventPENN HOSP OF UNIV OF PENN HEALTH SYSTEMS (ENGINEERING SERVICES): High Rise L&I license filing initially issued

    License 536490 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  211. PermitMajor alteration

    Permit 342488 · COMPLETED

    FOR ALTERATIONS TO EXISTING ROOF TO INCLUDE SLATE ROOF RESTORATION, NEW SLATE SHINGLES AND COPPER FLASHING AS PART OF AN EXISTING HOSPITAL COMPLEX AS PER PLANS.

  212. InvestigationCI INSP

    Case 274324 · CLOSED

    City marked the record closed; open the case for the closing reason.

  213. InvestigationCI INSP

    Case 274294 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  214. InvestigationCI INSP

    Case 274294 · CLOSED

    City marked the record closed; open the case for the closing reason.

  215. InvestigationCI INSP

    Case 274324 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  216. InvestigationCI INSP

    Case 274829 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  217. InvestigationCI INSP

    Case 274829 · CLOSED

    City marked the record closed; open the case for the closing reason.

  218. InvestigationCI INSP

    Case 274324 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  219. InvestigationCI INSP

    Case 274294 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  220. InvestigationCI INSP

    Case 274829 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  221. CertificationFacade Report

    Certification BC-2022-010373 · Safe with Repair

    Expires 2016-05-06

  222. ViolationVIOL C&I MESSAGE

    Case 274829 · Violation 2173117 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  223. ViolationHIRISE-PAY HIRISE FEE

    Case 274829 · Violation 2173118 · Code FC-408.12/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  224. InvestigationCI INSP

    Case 274829 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  225. ViolationVIOL C&I MESSAGE

    Case 274294 · Violation 2187620 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  226. ViolationHIRISE-PAY HIRISE FEE

    Case 274294 · Violation 2187621 · Code FC-408.12/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  227. ViolationVIOL C&I MESSAGE

    Case 274324 · Violation 2187639 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  228. ViolationHIRISE-PAY HIRISE FEE

    Case 274324 · Violation 2187640 · Code FC-408.12/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  229. ViolationEXT ADDRESS NUMBERS

    Case 274324 · Violation 2187641 · Code FC-505.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  230. InvestigationCI INSP

    Case 274294 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  231. InvestigationCI INSP

    Case 274324 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  232. PermitMajor alteration

    Permit 248278 · COMPLETED

    INTERIOR RENOVATIONS TO PATIENT ADMISSIONS AND TESTING, OPERATING ROOM REGISTRATION AND LABORATORY TESTING AREA ONLY.

  233. PermitDemolition

    Permit 248277 · COMPLETED

    DEMO OF INTERIOR FINISHES IN EXISTING PATIENT ADMISSIONS AND TESTING AREA

  234. PermitPlumbing

    Permit 211059 · COMPLETED

    FIXTURE INSTALLATION

  235. PermitMajor alteration

    Permit 205765 · COMPLETED

    RADIATION PROTECTION UPGRADE TO THE EXISTING LINEAR ACCELERATOR VAULT AND INTERIOR RENOVATIONS TO THE LINEAR VAULT, CONTROL ROOM AND SIMULATOR ROOM AS PER PLANS.

  236. PermitDemolition

    Permit 205772 · COMPLETED

    DEMOLITION OF INTERIOR FINISHES AT LINEAR ACCELERATOR VAULT AREA. NO OTHER WORK ALLOWED UNDER THIS PERMIT.

  237. PermitPlumbing

    Permit 161189 · COMPLETED

    FIXTURE INSTALLATION

  238. PermitOperations

    Permit 7831 · COMPLETED

    5/27/08 - TENTS ERECTED ON SITE

  239. PermitOperations

    Permit 7866 · COMPLETED

    6/11/08 - TENT ERECTED ON SITE

  240. PermitMajor alteration

    Permit 147024 · COMPLETED

    WOOD WINDOW AND TRIM REPAIRS, DOWNSPOUTS AND RELATED DRAINAGE REPAIRS. SHOP DRAWINGS FOR WINDOW REPAIRS TO BE SUBMITED TO PHC FOR REVIEW SHOP DRAWING FOR ALL FINISHES

  241. PermitMechanical

    Permit 132772 · COMPLETED

    INSTALL DUCTWORK AND MECHANICAL UNITS.

  242. PermitMajor alteration

    Permit 116595 · COMPLETED

    INTERIOR ALTERATIONS TO 1ST FLOOR OF WIDENER & SCHIEDT BLDGS.

  243. PermitDemolition

    Permit 116596 · COMPLETED

    INTERIOR DEMO OF EMERG. DEPT. ON 1ST FLR OF WIDENER & SCHIEDT BLDG. NO CHANGES TO EXTERIOR AND NO WORK/ALTERATIONS TO WINDOWS OR DOORS AS PER P.H.C. APPROVAL.

  244. PermitMajor alteration

    Permit 34677 · COMPLETED

    RENOVATION OF EXISTING PACU AREA

  245. License issue eventCORMOCCO INC: Food Preparing and Serving business license initially issued

    License 338950 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

Where this comes from

Methodology & freshness

This report was assembled Jul 26, 2026, 2:04 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.