Apartment building report

801 Aramingo Ave

4 stories16,253 sqftCMX2built 2022

Property at a glanceApartments

Wood Capital Investments 1 LLC

2026 assessment
$2.1M OPA value, not a listing price
2027 published assessment
$2.1M Future roll, not the current tax bill
Neighborhood area
Fishtown · East Kensington Approximate · based on ZIP 19125
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $2,136,300. It is not yet the billed-year tax basis.

$0$1.3M$2.5M$2.1M20202022202420262027
Property assessmentAssessmentL&I violationPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record31 events · exact dates, newest first
  1. LicenseWood Capital Investments 1, LLC (SL Rentals, LLC): Rental landlord or residential registration marked expired
  2. L&I violationEXTERIOR AREA SANITATION
  3. InspectionL&I investigation
  4. CertificationFire Alarm Certification
  5. InspectionL&I investigation
  6. LicenseWood Capital Investments 1, LLC (SL Rentals, LLC): Rental landlord or residential registration initially issued
  7. InspectionL&I investigation
  8. CertificationFire Alarm Certification
  9. L&I violationWORK NOT ACCORDING TO PLANS
  10. InspectionL&I investigation
  11. PermitNew Construction
  12. PermitNew Construction
  13. PermitNew Construction
  14. PermitNew Construction or Additions
  15. PermitNew Construction or Additions
  16. PermitNew Construction or Additions
  17. InspectionL&I investigation
  18. PermitNew Construction or Additions
  19. PermitNew Construction or Additions
  20. PermitNew Construction or Additions
  21. PermitNew Construction
  22. PermitNew Construction
  23. PermitNew Construction
  24. L&I violationSPECIAL INSPECTIONS REQUIRED
  25. InspectionL&I investigation
  26. PermitNew Construction
  27. PermitNew Construction
  28. PermitNew Construction
  29. PermitNew Construction
  30. PermitNew Construction
  31. PermitNew Construction

Verify the public record

$2,919/year estimated property tax

2026 taxable assessment $208,540 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $2,136,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881000081
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $208,540 of $2,085,400 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartments, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartments Non Pd Pkg Lot Commercial
Owner
Wood Capital Investments 1 LLC
$ / sq ft
$131 below the $147 median for 2,826 apartments parcels citywide
Interior area
16,253 sqft
Lot size
2,975 sqft
Stories
4
Built
2022
Zoning
CMX2

Recorded owner

Who's behind it

Wood Capital Investments 1 LLC · corporate / LLC owner

• Tax bills mail to 2301 Washington Ave Ste 1, Philadelphia PA, 19146

Block context

800 block of Aramingo Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 825-29 Aramingo Ave  ·  835 Aramingo Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗

No L&I business license is on record at this address in data through Jul 24, 2026.

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

Wood Capital Investments 1, LLC (SL Rentals, LLC)Expired

Rental · Initial issue date Jun 23, 2022 · Terminal license date Jun 22, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 31 dated rows
  1. License terminal eventWood Capital Investments 1, LLC (SL Rentals, LLC): Rental landlord or residential registration marked expired

    License 899118 · Expired

    License event. Registration does not prove present operation or storefront occupancy.

  2. ViolationEXTERIOR AREA SANITATION

    Case CF-2026-071123 · Violation VI-2026-044098 · Code PM15-302.1 · SVN ISSUED

    Resolution: SVN ISSUED

  3. InvestigationL&I investigation

    Case CF-2026-071123

  4. CertificationFire Alarm Certification

    Certification BC-2023-010522 · Certified

    Expires 2023-07-19

  5. InvestigationL&I investigation

    Case CF-2022-038900 · PASSED

    The cited inspection visit was marked passed.

  6. License issue eventWood Capital Investments 1, LLC (SL Rentals, LLC): Rental landlord or residential registration initially issued

    License 899118 · Expired

    License event. Registration does not prove present operation or storefront occupancy.

  7. InvestigationL&I investigation

    Case CF-2022-038900 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  8. CertificationFire Alarm Certification

    Certification BC-2023-010523 · Certified

    Expires 2023-05-19

  9. ViolationWORK NOT ACCORDING TO PLANS

    Case CF-2022-038900 · Violation VI-2022-029978 · Code A-302.10/2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  10. InvestigationL&I investigation

    Case CF-2022-038900 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  11. PermitNew Construction

    Permit EP-2021-010799 · Completed

    Install 300 AMP incoming service , wiring throughout ,110 v interconnected smoke alarms. New fire alarm system with low frequency sound in all sleeping areas(living rms and bedrooms). ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2018 PHILA FIRE CODE,2017 NEC,2016 NFPA-72. BUILDING C.

  12. PermitNew Construction

    Permit EP-2021-010800 · Completed

    INSTALL A 300 AMP SERVICE, (4) GANG METER BANK, (3) 125 AMP PANELS & FEEDERS, (1) 100 AMP PANEL & FEEDER. PROVIDE WIRING THROUGHOUT COMMON AREAS AND THREE UNITS. INSTALL LIGHTS, SWITCHES, RECEPTACLES, POWER FOR THE MECHANICAL & HVAC EQUIPMENT. INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC & 2016 NFPA-72.

  13. PermitNew Construction

    Permit EP-2021-010792 · Completed

    400 AMP incoming service ,wiring throughout by 2017 NEC CODE New fire alarm system per 2016 NFPA 72

  14. PermitNew Construction or Additions

    Permit PP-2021-011037 · Completed

    5 Family Dwellings: 5 Kitchens, 5 Laundry, 5 HWH, 10 Toilets, 4 Tubs, 3 Showers, 10 Vanity

  15. PermitNew Construction or Additions

    Permit PP-2021-010863 · Completed

    Installation of all interior supply and Drain/Waste/Vent pipe to the listed fixtures per the 2018 Philadelphia Plumbing Code. Sizes and locations per plans.

  16. PermitNew Construction or Additions

    Permit PP-2021-010860 · Completed

    Installation of all interior supply and Drain/Waste/Vent pipe to the listed fixtures per the 2018 Philadelphia Plumbing Code. Sizes and locations per plans.

  17. InvestigationL&I investigation

    Case CF-2021-018415 · PASSED

    The cited inspection visit was marked passed.

  18. PermitNew Construction or Additions

    Permit PP-2021-010348 · Completed

    INSTALL NEW 2" WATER DISTRIBUTION, CURB TRAP , FAI AND MAIN DRAINS, METER , BACK FLOW PREVENTER 801-11 ARAMINGO AVE BUILDING A

  19. PermitNew Construction or Additions

    Permit PP-2021-010356 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  20. PermitNew Construction or Additions

    Permit PP-2021-010364 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  21. PermitNew Construction

    Permit FP-2020-002481 · Completed

    FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A FOUR (4) STORY MULTI-FAMILY DWELLING (BUILDING A) TO INCLUDE A NEW TWO (2) INCH FIRE SERVICE LINE AND A NEW TWO (2) INCH BACKFLOW PREVENTION DEVICE IN ACCORDANCE WITH NFPA 13R. FOR THE INSTALLATION OF A CLASS I MANUAL WET STANDPIPE SYSTEM IN ACCORDANCE WITH NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. [AMENDMENT APPROVED 6/1/2022 FOR A CHANGE IN BACKFLOW PREVENTER TO A TWO (2) INCH WILKINS 950XLT2 MODEL AS PER APPROVED AMENDED FIRE SUPPRESSION PLANS, HYDRAULIC CALCULATIONS, AND CP-100 FORM.]

  22. PermitNew Construction

    Permit FP-2020-002482 · Completed

    FOR THE INSTALLATION OF AN AUTOMATIC WET SPRINKLER SYSTEM THROUGHOUT A FOUR (4) STORY MULTI-FAMILY DWELLING (BUILDING B) TO INCLUDE A NEW TWO (2) INCH FIRE SERVICE LINE AND A NEW TWO (2) INCH BACKFLOW PREVENTION DEVICE IN ACCORDANCE WITH NFPA 13R. FOR THE INSTALLATION OF A CLASS I MANUAL WET STANDPIPE SYSTEM IN ACCORDANCE WITH NFPA 14. ALL WORK TO BE DONE PER APPROVED PLANS BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA. [AMENDMENT APPROVED 6/2/2022 FOR A CHANGE IN BACKFLOW PREVENTER TO A TWO (2) INCH WILKINS 950XLT2 MODEL AS PER APPROVED AMENDED FIRE SUPPRESSION PLANS, HYDRAULIC CALCULATIONS, AND CP-100 FORM.]

  23. PermitNew Construction

    Permit MP-2020-006395 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK THROUGHOUT A NEW FOUR (4) STORY ATTACHED STRUCTURE TO BE USED AS GROUP R-2; APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS; ALL WORK TO BE DONE PER APPROVED PLANS; IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK; ALL DUCTWORK TO BE SELF-CONTAINED WITHIN EACH DWELLING UNIT; SEE CP-2020-000803 FOR NEW CONSTRUCTION PERMIT.

  24. ViolationSPECIAL INSPECTIONS REQUIRED

    Case CF-2021-018415 · Violation VI-2021-014059 · Code A-304.2/2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  25. InvestigationL&I investigation

    Case CF-2021-018415 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  26. PermitNew Construction

    Permit FP-2020-002483 · Completed

    COMBINED AUTOMATIC SPRINKLER & CLASS I MANUAL WET STANDPIPE SYSTEMS WITH TWO (2) INCH FIRE SERVICE LINE & BACKFLOW PREVENTION (BFP) ASSEMBLY TO SERVE PREVIOUSLY APPROVED MULTI-FAMILY DWELLING. AUTOMATIC SPRINKLER SYSTEM & STANDPIPE SYSTME INSTALLATION PER NFPA 13R/14. Amendment to change the BFP device as per approved revised plans.

  27. PermitNew Construction

    Permit MP-2020-006385 · Completed

    FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE SPLIT SYSTEM UNITS, AIR DEVISES, DIFFUSERS/REGISTERS/GRILLES, AND ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  28. PermitNew Construction

    Permit MP-2020-006391 · Completed

    For the installation of a mechanical/HVAC system (including all associated ductwork, registers, diffusers, grilles, and appliances) throughout the multi-family building, as per plans; see CP-2020-

  29. PermitNew Construction

    Permit CP-2020-000806 · Completed

    FOR THE ERECTION OF AN ATTACHED LIGHT-FRAMED STRUCTURE FOR THE USE OF THREE (3) HOUSEHOLD LIVING UNITS TO INCLUDE EGRESS WINDOW WELLS, REAR BALCONY DECKS, ROOF DECKS, ACCESS PILOT HOUSES, UNDERPINNING INSTALLATION, RATED FIRE WALLS, RATED FLOOR/CEILING ASSEMBLIES, RATED FIRE BARRIERS AND STAIR SHAFT ENCLOSURES, INTERIOR FIRE PARTITIONS, AND (IBC 2018) [ADDITIONAL EFFICIENCY PACKAGE--REDUCED SERVICE WATER HEATING DEMAND SECTION 406.7.] **SEPARATE PERMITS REQ'D FOR ELECTRICAL, MECHANICAL, ELECTRICAL, AND FIRE SUPPRESSION SYSTEM INSTALLATIONS.** AMENDMENT: REVISED FOR APPROVAL TO REDUCE THE SPRINKLER SYSTEM REQUIREMENTS TO A NFPA 13R SYSTEM. 4/8/2021: FOR AMENDMENT TO REVISE THE SPECIAL INSPECTION AGENCY AND REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF SPECIAL INSPECTIONS.

  30. PermitNew Construction

    Permit CP-2020-000803 · Completed

    FOR THE ERECTION OF AN ATTACHED LIGHT-FRAMED STRUCTURE FOR THE USE OF FIVE (5) HOUSEHOLD LIVING UNITS TO INCLUDE EGRESS WINDOW WELLS, REAR BALCONY DECKS, ROOF DECKS, ACCESS PILOT HOUSES, UNDERPINNING INSTALLATION, RATED FIRE WALLS, RATED FLOOR/CEILING ASSEMBLIES, RATED FIRE BARRIERS AND STAIR SHAFT ENCLOSURES, INTERIOR FIRE PARTITIONS, AND (IBC 2018) [ADDITIONAL EFFICIENCY PACKAGE--REDUCED SERVICE WATER HEATING DEMAND SECTION 406.7.] **SEPARATE PERMITS REQ'D FOR ELECTRICAL, MECHANICAL, ELECTRICAL, AND FIRE SUPPRESSION SYSTEM INSTALLATIONS.** AMENDMENT: REVISED FOR APPROVAL TO REDUCE THE SPRINKLER SYSTEM REQUIREMENTS TO A NFPA 13R SYSTEM. 4/8/21: FOR REVISION OF SPECIAL INSPECTION AGENCY AND REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF SPECIAL INSPECTIONS.

  31. PermitNew Construction

    Permit CP-2020-000805 · Completed

    FOR THE ERECTION OF AN ATTACHED LIGHT-FRAMED STRUCTURE FOR THE USE OF THREE (3) HOUSEHOLD LIVING UNITS TO INCLUDE EGRESS WINDOW WELLS, REAR BALCONY DECKS, ROOF DECKS, ACCESS PILOT HOUSES, UNDERPINNING INSTALLATION, RATED FIRE WALLS, RATED FLOOR/CEILING ASSEMBLIES, RATED FIRE BARRIERS AND STAIR SHAFT ENCLOSURES, INTERIOR FIRE PARTITIONS, AND (IBC 2018) [ADDITIONAL EFFICIENCY PACKAGE--REDUCED SERVICE WATER HEATING DEMAND SECTION 406.7.] **SEPARATE PERMITS REQ'D FOR ELECTRICAL, MECHANICAL, ELECTRICAL, AND FIRE SUPPRESSION SYSTEM INSTALLATIONS.** AMENDMENT 10/23/2020--FOR THE AMENDMENT OF DWG A0.01 FOR THE REVISION OF THE REQUIRED SPRINKLER SYSTEM INSTALLATION TO A NFPA 13R SYSTEM. 4/8/21: FOR REVISION OF SPECIAL INSPECTION AGENCY AND REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF SPECIAL INSPECTIONS.

Where this comes from

Methodology & freshness

This report was assembled Jul 25, 2026, 5:27 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)