Property report

816 W Norris St

11,778 sqftRM1built 2018

Property at a glanceApartment building

Philadelphia Housing Auth

2026 assessment
$153K OPA value, not a listing price
2027 published assessment
$153K Future roll, not the current tax bill
Neighborhood area
Olde Kensington · North Philadelphia Approximate · based on ZIP 19122
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $153,300. It is not yet the billed-year tax basis.

$0$100K$200K$153K201720192021202320252027
Property assessmentAssessmentAppealPermit

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record34 events · exact dates, newest first
  1. PermitAlterations
  2. PermitPlumbing
  3. PermitElectrical
  4. PermitPlumbing
  5. PermitMechanical
  6. PermitMechanical
  7. PermitMechanical
  8. PermitMechanical
  9. PermitMechanical
  10. PermitPlumbing
  11. PermitPlumbing
  12. PermitPlumbing
  13. PermitPlumbing
  14. PermitPlumbing
  15. PermitPlumbing
  16. PermitElectrical
  17. PermitElectrical
  18. PermitElectrical
  19. PermitElectrical
  20. PermitPlumbing
  21. PermitPlumbing
  22. PermitSuppression
  23. PermitSuppression
  24. PermitSuppression
  25. PermitSuppression
  26. PermitSuppression
  27. PermitNew construction
  28. PermitNew construction
  29. PermitNew construction
  30. PermitNew construction
  31. PermitNew construction
  32. PermitZoning admin review
  33. AppealBuilding standards appeal
  34. PermitZoning/use

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $153,300. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 886856303
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Not a house

Apartment building. OPA shows a full or near-full assessment exemption whose basis must be verified. A $0 assessment-based estimate does not prove the live Tax Center account has no prior-period balance or other charges.

What it is
Apartment building Apts 5-50 Units Masonry
Owner
Philadelphia Housing Auth Public / institutional
$ / sq ft
$13 assessed value ÷ interior sqft
Interior area
11,778 sqft
Lot size
6,209 sqft
Built
2018
Zoning
RM1

Recorded owner

Who's behind it

Philadelphia Housing Auth · corporate / LLC owner

• Owns 4773 properties across Philadelphia under this name, assessed at $1.4B combined
• Tax bills mail to 2013 Ridge Ave, Philadelphia PA, 19121

Block context

800 block of W Norris St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 810 W Norris St  ·  808 W Norris St

No business or residential license records

No business license or residential registration matched this OPA parcel in the latest City data.

Verify with the City ↗
Open every source row 34 dated rows
  1. PermitAlterations

    Permit PP-2022-013537 · Expired

    Sewer curb trap FAI replacement.

  2. PermitPlumbing

    Permit 931111 · COMPLETED

    EZ PLUMBING PERMIT - PLUMBING CONSTRUCTION FOR A NEW SINGLE-FAMILY DWELLING. ROUGH IN UNDERGROUND AND ABOVE GROUND PLUMBING AND SET FIXTURES, 1 KS, 2 WC, 2 LAVS, 2 TUB, 2 FLOOR DRAINS PER 2004 PHILADELPHIA PLUMBING CODE.

  3. PermitElectrical

    Permit 867363 · COMPLETED

    INSTALL 3-LOAD CENTERS & 1-HOUSE PANEL & (400AMP FRAME 250AMP TRIP) INSTALL LIGHTS, RECEPTACLES, SWITCHES & TEL & CATV THROUGHOUT AS PER NEC 2008 EAST DISTRICT

  4. PermitPlumbing

    Permit 851840 · COMPLETED

    NEW CONSTRUCTION: INTERIOR PLUMBING; BUILDING #2; 3 STORY STRUCTURE; 3 FAMILY DWELLING-THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  5. PermitMechanical

    Permit 888929 · COMPLETED

    - FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  6. PermitMechanical

    Permit 872999 · COMPLETED

    COMPLETE NEW HVAC SYTEM WITH 3T HP OUTDOOR UNIT ON GROUND NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  7. PermitMechanical

    Permit 873041 · COMPLETED

    COMPLETE HVAC SYSTEM WITH 3T HEAT PUMP OUTDOOR UNIT ON GROUND - FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  8. PermitMechanical

    Permit 873119 · COMPLETED

    COMPLETE NEW HVAC SYSTEM 3 T HP WITH OUTDOOR UNIT ON GROUND EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  9. PermitMechanical

    Permit 873116 · COMPLETED

    COMPLETE NEW HVAC SYSTEM 3 T HP WITH OUTDOOR UNIT ON GROUND EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION IF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  10. PermitPlumbing

    Permit 836973 · COMPLETED

    ROUGH IN UNDERGROUND,ROUGH IN AND SET FIXTURES FOR 1-WH, 1KS, 2WC, 2LAV, 2TUB, PVC PIPE AND PEX WATER PIPE AND 1 FLOOR DRAIN.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  11. PermitPlumbing

    Permit 836964 · COMPLETED

    ROUGH IN UNDERGROUND,ROUGH IN AND SET FIXTURES FOR 1-WH, 1KS, 2WC, 2LAV, 2TUB, PVC PIPE AND PEX WATER PIPE AND 1 FLOOR DRAIN.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  12. PermitPlumbing

    Permit 836974 · COMPLETED

    ROUGH IN UNDERGROUND,ROUGH IN AND SET FIXTURES FOR 1-WH, 1KS, 2WC, 2LAV, 2TUB, PVC PIPE AND PEX WATER PIPE AND 1 FLOOR DRAIN.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  13. PermitPlumbing

    Permit 832660 · COMPLETED

    INSTALL 6" HOUSE TRAP 4" FAI, 4" AREA DRAIN, 3" RWC, 1" & (2) 3/4" WATER SERVICE TO 5" OUT PA1# 2017-2982434 (ADDITONAL PERMIT REQUIRED FOR INGOING WATER SERVICE PRIOR TO ISSUANCE OF INTERIOR PLUMBING PERMIT) "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  14. PermitPlumbing

    Permit 833409 · COMPLETED

    ROUGH IN UNDERGROUND AND ABOVE. ROUGH IN AND SET FIXTURES 1WB, 1 KS, 1 2WC, 2 LAV, 2 TUB, PVC, PIPE AND PEX WATER PIPE 1 FLOOR DRAIN AS PER PHILADELPHIA 2004 PLUMBING CODE.

  15. PermitPlumbing

    Permit 829560 · COMPLETED

    INSTALL 1-6" COMBINED LATERAL & HOUSE TRAP WITH FAI, 1-2" COMBINED WATER SERVICE WITH RFSS COMBO WATER METER, 1-3" REAR YARD DRAIN AND RWC TO 5 " OUT PA1# 2017-2772368 (ADDITONAL PERMIT REQUIRED FOR INGOING WATER SERVICE PRIOR TO ISSUANCE OF INTERIOR PLUMBING PERMIT) "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  16. PermitElectrical

    Permit 822685 · COMPLETED

    INSTALL 200AMP SERVICE,COMPLETE GROUNDING ALL NEW WIRING,SWITCHES,LIGHTS,RECEPTACLES,110V SMOKE DETECTORS/CO2 DETECTORS,CATV AND TELEPHONE WIRING PER 2008 NEC (SFD)

  17. PermitElectrical

    Permit 822686 · COMPLETED

    INSTALL 200AMP SERVICE,COMPLETE GROUNDING ALL NEW WIRING,SWITCHES,LIGHTS,RECEPTACLES,110V SMOKE DETECTORS/CO2 DETECTORS,CATV AND TELEPHONE WIRING PER 2008 NEC (SFD)

  18. PermitElectrical

    Permit 822687 · COMPLETED

    INSTALL 200AMP SERVICE,COMPLETE GROUNDING ALL NEW WIRING,SWITCHES,LIGHTS,RECEPTACLES,110V SMOKE DETECTORS/CO2 DETECTORS,CATV AND TELEPHONE WIRING PER 2008 NEC (SFD)

  19. PermitElectrical

    Permit 822725 · COMPLETED

    INSTALL 200 AMP SERVICE, COMPLETE GROUNDDING ALL NEW WIRING , SWITCHES, LIGHTS, RECEPTACLES, 110 V SMIKE DETECTORS/ CO2 DETECTORS, CATV AND TEL WIRING, THROUGHT OUT THE HOME AS PER 2008 NEC

  20. PermitPlumbing

    Permit 822765 · COMPLETED

    INSTALL HOUSE TRAP WITH FAI 1-2" COMBINED WATER SERVICE WITH RFSS COMBO WATER METER 1-3" REAR YARD DRAIN AND RWC

  21. PermitPlumbing

    Permit 813515 · COMPLETED

    INSTALL TO INCLUDE 1-6" COMBINED LATERAL & HOUSE TRAP WITH FAI, 1-2" COMBINED WATER SERVICE WITH RFSS COMBO WATER METER. 1-3" REAR YARD DRAIN AND RWC. ALL WORK TO 5' OF BLDG 20172082159 SELF CERTIFICATION NO LONGER ACCEPTED ALL TRENCHES IN EXCESS OF 5 FT MUST HAVE APPROVED SHORING AT THE TIME OF INSPECTION.

  22. PermitSuppression

    Permit 810327 · COMPLETED

    INSTALL NEW FIRE SUPPRESSION SYSTEM COMPLYING WITH NFPA 13 THROUGHOUT THE BUILDING TO INCLUDE 2" MAIN FIRE SERVICE LINE AND 2" AMES LF2000BM1 BACKFLOW PREVENTION ASSEMBLY AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  23. PermitSuppression

    Permit 805952 · COMPLETED

    FOR THE INSTALLATION OF A RESIDENTIAL FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13-D THROUGHOUT A THREE (3) STORY STRUCTURE PER PLANS. THIS IS A MULTI-PURPOSE SYSTEM UTILIZING A COMBINED TWO INCH (2") DOMESTIC AND FIRE SERVICE LINE. SEPARATE PERMITS REQUIRED FOR ALL PLUMBING WORK.

  24. PermitSuppression

    Permit 805951 · COMPLETED

    FOR THE INSTALLATION OF A RESIDENTIAL FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13-D THROUGHOUT A THREE (3) STORY STRUCTURE PER PLANS. THIS IS A MULTI-PURPOSE SYSTEM UTILIZING A COMBINED TWO INCH (2") DOMESTIC AND FIRE SERVICE LINE. SEPARATE PERMITS REQUIRED FOR ALL PLUMBING WORK.

  25. PermitSuppression

    Permit 805950 · COMPLETED

    FOR THE INSTALLATION OF A RESIDENTIAL FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13-D THROUGHOUT A THREE (3) STORY STRUCTURE PER PLANS. THIS IS A MULTI-PURPOSE SYSTEM UTILIZING A COMBINED TWO INCH (2") DOMESTIC AND FIRE SERVICE LINE. SEPARATE PERMITS REQUIRED FOR ALL PLUMBING WORK.

  26. PermitSuppression

    Permit 799512 · COMPLETED

    FURNISH & INSTALL NEW SPRINKLER SYSTEM FOR A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING - UTILIZING A 2 INCH COMBINED FIRE & DOMESTIC WATER SUPPLY LINE AS PER NFPA 13D

  27. PermitNew construction

    Permit 752723 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 749143 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  28. PermitNew construction

    Permit 752724 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 749143 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  29. PermitNew construction

    Permit 752725 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 749143 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  30. PermitNew construction

    Permit 752726 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS A SINGLE FAMILY DWELLING. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13D (MINIMUM)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. SEE A/P NO 749143 FOR APPROVED PLANS. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 8 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  31. PermitNew construction

    Permit 741967 · COMPLETED

    FOR THE ERECTION OF A THREE (3) STORY STRUCTURE, FOR USE AS THREE (3) DWELLING UNITS. STRUCTURE IS FRAME CONSTRUCTION AND EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM (NFPA 13 (PER PROVISO)). THE PROPOSED FOUNDATION IS COMPOSED OF A FLOOR SLAB THAT IS STRUCTURALLY SUPPORTED BY DRILLED-IN HELICAL PIERS. SEPARATE PERMITS WILL BE REQUIRED FOR THE ENGINEERED TRUSS DRAWINGS, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE SUPPRESSION. UNIT ON THE 1ST FLOOR OF THE STRUCTURE TO BE FULLY ACCESSIBLE. SEE BBS CASE NO 29747R PROVISO: SPRINKLER PER NFPA 13. A COVERED WALKWAY OR SIDEWALK CLOSURE SHALL BE REQUIRED WITHIN 9 FEET OF BUILDING FAÇADE IN ACCORDANCE WITH SECTION 3306 OF THE IBC. SEPARATE BUILDING AND/OR STREETS DEPARTMENT PERMITS ARE REQUIRED.

  32. PermitZoning admin review

    Permit 769968 · COMPLETED

    FOR THE ADMINISTRATIVE REVIEW OF A/P NO 738189 (CAL NO 28924) TO DECREASE THE HEIGHT OF THE BUILDING AND PARAPET AND TO DOCUMENT THAT BUILDING #1 IS AN ATTACHED STRUCTURE (BASED ON THE DETERMINATION OF THE REAR LOT LINE BY CITY PLANNING COMMISSION). NO CHANGE TO FOOTPRINT OR GFA OF STRUCTURES. A/P NO 738189 WAS ISSUED FOR THE ERECTION OF TWO (2) STRUCTURES (BUILDING #1 DETACHED, BUILDING #2 DETACHED). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (SEVEN (7) DWELLING UNITS TOTAL, FOUR (4) DWELLING IN BUILDING #1, THREE (3) DWELLINGS IN BUILDING #2). NO SIGNS ON THIS APPLICATION.

  33. AppealBuilding standards appeal

    Appeal 29747 · CLOSED · Denied

    Related permit 741967 · ON 12/29/2016, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #741967.

  34. PermitZoning/use

    Permit 738189 · COMPLETED

    FOR THE LOT ADJUSTMENT TO CREATE ONE (1) LOT (PARCEL E) FROM SEVEN (7) EXISTING DEEDED LOTS (1959 N 9TH STREET, 1961 N 9TH STREET, 1963 N 9TH STREET, 812 W NORRIS STREET, 814 W NORRIS STREET, 816 W NORRIS STREET AND 818 W NORRIS STREET) AND TWO (2) OPA ACCOUNTS (1959-63 N 9TH STREET AND 812-18 W NORRIS STREET) AND TO EXTINGUISH A PORTION OF AN EXISTING ALLEY AND FOR THE CREATION OF A NEW ALLEY. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR THE ERECTION OF TWO (2) STRUCTURES (BUILDING #1 DETACHED, BUILDING #2 DETACHED). SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. FOR USE AS MULTI-FAMILY HOUSEHOLD LIVING (SEVEN (7) DWELLING UNITS TOTAL, FOUR (4) DWELLING IN BUILDING #1, THREE (3) DWELLINGS IN BUILDING #2). NO SIGNS ON THIS APPLICATION.

Where this comes from

Methodology & freshness

This report was assembled Jul 24, 2026, 9:58 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)