Commercial property report

1102-48 Market St

2 stories61,406 sqftCMX5built 2016

Property at a glanceCommercial

1100 Market St LP

2026 assessment
$13M OPA value, not a listing price
2027 published assessment
$13M Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $13,140,900. It is not yet the billed-year tax basis.

$0$10M$20M$13M2003200720112015201920232027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record413 events · exact dates, newest first
  1. LicenseIHB Center City Inc (Iron Hill Brewery & Restaurant): Food Preparing and Serving (30+ SEATS) business license initially issued
  2. PermitChange of Use
  3. PermitChange of Use
  4. InspectionL&I investigation
  5. InspectionL&I investigation
  6. InspectionL&I investigation
  7. InspectionL&I investigation
  8. L&I violationBENCHMARKING LATE
  9. L&I violationBENCHMARKING LATE
  10. InspectionL&I investigation
  11. InspectionL&I investigation
  12. InspectionL&I investigation
  13. L&I violationFIRE EXTINGUISHER HANGERS & BRACKETS
  14. L&I violationSMOKE CONTROL SYSTEM RECORDS
  15. L&I violationEXIT SIGN ILLUMINATION
  16. L&I violationFIRE EXTINGUISHERS REQUIRED
  17. L&I violationHAZARD IDENTIFICATION SIGNS
  18. L&I violationEXIT SIGN ILLUMINATION
  19. L&I violationHAZARD IDENTIFICATION SIGNS
  20. L&I violationFIRE EXTINGUISHERS REQUIRED
  21. L&I violationSUPPRESSION SYSTEM TESTING & MAINTENANCE
  22. InspectionL&I investigation
  23. PermitAddition and/or Alterations
  24. PermitAlterations
  25. PermitAddition and/or Alteration
  26. PermitAddition and/or Alterations
  27. PermitAddition and/or Alteration
  28. PermitAlterations
  29. LicenseMULHERINS EM LLC: Food Preparing and Serving (30+ SEATS) business license marked inactive
  30. PermitAddition and/or Alteration
  31. PermitAddition and/or Alteration
  32. AppealZBA Permit Denial - Variance
  33. LicenseMULHERINS EM LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
  34. PermitChange of Use
  35. LicenseWAWA #8112 (WAWA #8112): Food Preparing and Serving business license marked closed
  36. InspectionL&I investigation
  37. L&I violationNO SMOKING SIGNS
  38. L&I violationFIRE EXTINGUISHER CONSPICUOUS LOCATION
  39. InspectionL&I investigation
  40. PermitAddition and/or Alterations
  41. InspectionL&I investigation
  42. PermitTemporary Tents and Canopies
  43. PermitAddition and/or Alteration
  44. L&I violationFACADES
  45. InspectionL&I investigation
  46. PermitAddition and/or Alterations
  47. PermitAlterations
  48. InspectionL&I investigation
  49. PermitAddition and/or Alterations
  50. L&I violationINSPECTION, TESTING & MAINTENANCE
  51. L&I violationSECURING COMPRESSED CYLINDERS
  52. L&I violationHAZARD IDENTIFICATION SIGNS
  53. L&I violationEXIT SIGN ILLUMINATION
  54. InspectionL&I investigation
  55. PermitAddition and/or Alteration
  56. PermitAddition and/or Alteration
  57. PermitInterior Non-Load-Bearing Wall Demo.
  58. LicenseWAWA #8112 (WAWA #8112): Food Establishment, Retail Perm Location (Large) business license marked closed
  59. InspectionL&I investigation
  60. InspectionL&I investigation
  61. PermitChange of Use
  62. InspectionL&I investigation
  63. InspectionL&I investigation
  64. L&I violationHIGH RISE LICENSE REQUIRED
  65. InspectionL&I investigation
  66. InspectionL&I investigation
  67. L&I violationNEW USE
  68. PermitAddition and/or Alteration
  69. PermitChange of Use
  70. InspectionL&I investigation
  71. PermitAddition and/or Alteration
  72. PermitSign
  73. LicenseSGB Master Tenant, LLC: Food Preparing and Serving (30+ SEATS) business license initially issued
  74. PermitNew Construction
  75. InspectionBC INSP (likely: building-code inspection)
  76. PermitNew Construction
  77. PermitNew Construction
  78. PermitAlterations
  79. PermitElectrical
  80. PermitElectrical
  81. PermitAddition and/or Alteration
  82. PermitElectrical
  83. PermitSuppression
  84. PermitPlumbing
  85. PermitMechanical
  86. PermitMajor alteration
  87. PermitAdministrative
  88. PermitAdministrative
  89. PermitElectrical
  90. PermitNew Construction
  91. PermitElectrical
  92. License1100 Market Street LP (The Ludlow ): High Rise L&I license filing initially issued
  93. License1100 Market Street LP (The Ludlow ): Rental landlord or residential registration initially issued
  94. PermitUse
  95. PermitSign
  96. PermitElectrical
  97. PermitZoning/use
  98. L&I violationPERM Z- NEW USE
  99. L&I violationVIOL BC MESSAGE
  100. InspectionBC INSP (likely: building-code inspection)
  101. InspectionBC INSP (likely: building-code inspection)
  102. PermitSuppression
  103. PermitMajor alteration
  104. PermitMechanical
  105. PermitUse
  106. InspectionCI INSP
  107. L&I violationSTORAGE EQUIPMENT ROOMS
  108. L&I violationMEANS OF EGRESS OBSTRUCTION
  109. L&I violationLABELING
  110. L&I violationFIRE ALARM TESTED/CERTIFIED
  111. L&I violationFIRE SUPPRESSION CERTIFICATION
  112. L&I violationCEILING CLEARANCE
  113. InspectionCI INSP
  114. PermitSuppression
  115. PermitZoning/use
  116. PermitSign
  117. PermitSuppression
  118. AppealZoning board appeal
  119. PermitNew Construction
  120. PermitSign
  121. PermitZoning/use
  122. PermitElectrical
  123. PermitSign
  124. PermitZoning/use
  125. PermitElectrical
  126. LicenseWAWA #8112 (WAWA #8112): Food Establishment, Retail Perm Location (Large) business license initially issued
  127. LicenseWAWA #8112 (WAWA #8112): Food Preparing and Serving business license initially issued
  128. PermitAdministrative
  129. PermitAdministrative
  130. PermitPlumbing
  131. PermitElectrical
  132. PermitSuppression
  133. PermitPlumbing
  134. PermitSuppression
  135. PermitMechanical
  136. PermitNew construction
  137. PermitMechanical
  138. PermitZoning/use
  139. PermitPlumbing
  140. PermitElectrical
  141. InspectionBP_BLDG
  142. PermitAdministrative
  143. PermitMechanical
  144. PermitSuppression
  145. PermitElectrical
  146. PermitAdministrative
  147. PermitSuppression
  148. PermitMajor alteration
  149. PermitMechanical
  150. PermitAdministrative
  151. PermitPlumbing
  152. PermitAdministrative
  153. AppealBuilding standards appeal
  154. PermitMajor alteration
  155. PermitZoning/use
  156. PermitMajor alteration
  157. PermitSign
  158. PermitPlumbing
  159. InspectionBP_BLDG
  160. PermitZoning/use
  161. PermitUse
  162. PermitMechanical
  163. PermitAdministrative
  164. PermitAdministrative
  165. PermitSuppression
  166. PermitSuppression
  167. PermitSign
  168. PermitAdministrative
  169. PermitPlumbing
  170. PermitElectrical
  171. PermitAdministrative
  172. PermitUse
  173. PermitNew construction
  174. PermitMajor alteration
  175. L&I violationARCHITECT/ENGINEER SERVICES
  176. L&I violationPERMB- WORK NOT SAME AS PERMIT
  177. InspectionBP_BLDG
  178. PermitMechanical
  179. PermitAdministrative
  180. PermitElectrical
  181. PermitSuppression
  182. PermitNew construction
  183. InspectionBP_BLDG
  184. PermitAdministrative
  185. PermitAdministrative
  186. PermitAdministrative
  187. PermitUse
  188. PermitSuppression
  189. PermitElectrical
  190. PermitElectrical
  191. PermitAdministrative
  192. L&I violationWORKMANLIKE- BUILDING CODE
  193. L&I violationLISTED CONDIT DOES NOT COMPLY
  194. InspectionBP_BLDG
  195. PermitMajor alteration
  196. PermitSuppression
  197. PermitSuppression
  198. PermitZoning/use
  199. PermitPlumbing
  200. PermitElectrical
  201. InspectionBP_BLDG
  202. PermitSuppression
  203. PermitPlumbing
  204. L&I violationPERMP- INST NEW PLUMBING
  205. L&I violationPENALTY- NO PLUMB PERM INFO
  206. InspectionBP_BLDG
  207. PermitNew construction
  208. PermitNew construction
  209. PermitZoning/use
  210. PermitElectrical
  211. PermitSuppression
  212. PermitAdministrative
  213. PermitSuppression
  214. PermitElectrical
  215. PermitAddition
  216. PermitUse
  217. PermitSuppression
  218. PermitSuppression
  219. PermitSuppression
  220. PermitElectrical
  221. PermitAdministrative
  222. PermitPlumbing
  223. PermitZoning/use
  224. AppealBuilding standards appeal
  225. PermitAlteration
  226. PermitSuppression
  227. PermitZoning/use
  228. PermitAdministrative
  229. PermitNew construction
  230. PermitNew construction
  231. AppealBuilding standards appeal
  232. PermitAdministrative
  233. PermitElectrical
  234. PermitAdministrative
  235. PermitPlumbing
  236. InspectionBC INSP (likely: building-code inspection)
  237. InspectionPRECOURT (likely: pre-court compliance inspection)
  238. InspectionPRECOURT (likely: pre-court compliance inspection)
  239. InspectionBC INSP (likely: building-code inspection)
  240. InspectionBC INSP (likely: building-code inspection)
  241. InspectionPRECOURT (likely: pre-court compliance inspection)
  242. InspectionCI INSP
  243. InspectionCI INSP
  244. InspectionCI INSP
  245. InspectionCI INSP
  246. InspectionCI INSP
  247. InspectionCI INSP
  248. InspectionBC INSP (likely: building-code inspection)
  249. LicenseNITIN J DESAI: Vendor - Newsstand business license marked inactive
  250. PermitNew construction
  251. PermitNew construction
  252. LicenseV & D JEWELRY INCORPORATED (PLATINUM JEWELERS): Precious Metal Dealer business license marked inactive
  253. PermitZoning/use
  254. PermitZoning/use
  255. PermitDemolition
  256. PermitZoning/use
  257. PermitZoning/use
  258. InspectionBC INSP (likely: building-code inspection)
  259. InspectionBC INSP (likely: building-code inspection)
  260. InspectionBC INSP (likely: building-code inspection)
  261. InspectionBC INSP (likely: building-code inspection)
  262. InspectionBC INSP (likely: building-code inspection)
  263. InspectionBC INSP (likely: building-code inspection)
  264. InspectionBC INSP (likely: building-code inspection)
  265. InspectionBC INSP (likely: building-code inspection)
  266. L&I violationANNUAL CERT FIRE ALARM
  267. L&I violationANNUAL CERT FIRE ALARM
  268. L&I violationANNUAL CERT FIRE SUPP
  269. L&I violationRENEW LIC INDICATED
  270. L&I violationCAL LO (Commercial Activity License required)
  271. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  272. L&I violationANNUAL CERT FIRE ALARM
  273. L&I violationEXCEEDS PERMIT-SIGN
  274. L&I violationANNUAL CERT FIRE ALARM
  275. L&I violationCAL LO (Commercial Activity License required)
  276. L&I violationANNUAL CERT FIRE ALARM
  277. L&I violationCAL LO (Commercial Activity License required)
  278. L&I violationOBTAIN LIC INDICATED (Obtain the license identified in the notice)
  279. InspectionBC INSP (likely: building-code inspection)
  280. InspectionBC INSP (likely: building-code inspection)
  281. InspectionBC INSP (likely: building-code inspection)
  282. InspectionBC INSP (likely: building-code inspection)
  283. InspectionBC INSP (likely: building-code inspection)
  284. InspectionBC INSP (likely: building-code inspection)
  285. InspectionBC INSP (likely: building-code inspection)
  286. InspectionBC INSP (likely: building-code inspection)
  287. InspectionBC INSP (likely: building-code inspection)
  288. InspectionBC INSP (likely: building-code inspection)
  289. LicensePINALI INC: Food Establishment, Retail Permanent Location business license marked inactive
  290. LicenseV & D JEWELRY INCORPORATED (PLATINUM JEWELERS): Precious Metal Dealer business license initially issued
  291. LicenseRONALD AIKENS (RONN JAIMZ): Handbill Distribution L&I license filing marked inactive
  292. InspectionCI INSP
  293. PermitSign
  294. InspectionCI INSP
  295. PermitZoning/use
  296. L&I violationFIRE-ELECT OPEN JUNCTION BOX
  297. L&I violationVIOL C&I MESSAGE
  298. InspectionCI INSP
  299. InspectionCI INSP
  300. L&I violationFIRE-DOOR STOP PROHIBITED
  301. L&I violationVIOL C&I MESSAGE
  302. InspectionCI INSP
  303. LicenseRONALD AIKENS (RONN JAIMZ): Handbill Distribution L&I license filing initially issued
  304. InspectionCI INSP
  305. L&I violationVIOL C&I MESSAGE
  306. L&I violationFIRE PROT SYS MAINTENANCE
  307. InspectionCI INSP
  308. L&I violationANNUAL CERT FIRE SUPP
  309. L&I violationVIOL C&I MESSAGE
  310. L&I violationVIOL C&I MESSAGE
  311. InspectionCI INSP
  312. LicenseFLYERS WIVES CHARITIES INC: Special Permit L&I license filing marked inactive
  313. PermitSuppression
  314. LicenseFLYERS WIVES CHARITIES INC: Special Permit L&I license filing initially issued
  315. LicensePHILADELPHIA VISION OF CENTER CITY INC.: Handbill Distribution L&I license filing marked inactive
  316. PermitUse
  317. L&I violationVIOL C&I MESSAGE
  318. L&I violationLIC MUST BE AVAIL FOR INSP
  319. L&I violationINT S-FLOOR REPAIR (Repair the interior floor)
  320. PermitUse
  321. L&I violationSCALE 1 TO 50 LBS LO
  322. L&I violationDEALER IN PRECIOUS METALS LO
  323. InspectionBC INSP (likely: building-code inspection)
  324. PermitUse
  325. InspectionBC INSP (likely: building-code inspection)
  326. InspectionBC INSP (likely: building-code inspection)
  327. InspectionBC INSP (likely: building-code inspection)
  328. PermitAlteration
  329. LicensePHILADELPHIA VISION OF CENTER CITY INC.: Handbill Distribution L&I license filing initially issued
  330. InspectionCI INSP
  331. PermitElectrical
  332. PermitElectrical
  333. PermitAdministrative
  334. PermitPlumbing
  335. LicenseBIG BIG LOT INC: Vendor - Newsstand business license marked inactive
  336. PermitMajor alteration
  337. PermitElectrical
  338. PermitMechanical
  339. PermitDemolition
  340. PermitFast form building
  341. PermitUse
  342. PermitUse
  343. InspectionADMIN INSP (likely: administrative inspection)
  344. PermitFast form building
  345. InspectionBC INSP (likely: building-code inspection)
  346. InspectionBC INSP (likely: building-code inspection)
  347. InspectionBC INSP (likely: building-code inspection)
  348. L&I violationVIOL BC MESSAGE
  349. L&I violationSCALE 1 TO 50 LBS LO
  350. L&I violationVIOL BC MESSAGE
  351. L&I violationVIOL BC MESSAGE
  352. InspectionBC INSP (likely: building-code inspection)
  353. InspectionBC INSP (likely: building-code inspection)
  354. InspectionBC INSP (likely: building-code inspection)
  355. InspectionBC INSP (likely: building-code inspection)
  356. InspectionBC INSP (likely: building-code inspection)
  357. PermitMajor alteration
  358. AppealZoning board appeal
  359. L&I violationVIOL BC MESSAGE
  360. L&I violationVIOL BC MESSAGE
  361. InspectionBC INSP (likely: building-code inspection)
  362. InspectionBC INSP (likely: building-code inspection)
  363. L&I violationVIOL BC MESSAGE
  364. L&I violationVIOL BC MESSAGE
  365. L&I violationVIOL BC MESSAGE
  366. InspectionBC INSP (likely: building-code inspection)
  367. InspectionBC INSP (likely: building-code inspection)
  368. InspectionBC INSP (likely: building-code inspection)
  369. L&I violationANNUAL CERT FIRE SUPP
  370. L&I violationFIRE EXTING-INSTALL TYPE K
  371. L&I violationAFES-COMM KITCH SERVICE & CERT
  372. L&I violationVIOL C&I MESSAGE
  373. L&I violationANNUAL CERT FIRE SUPP INCOMPL
  374. InspectionCI INSP
  375. L&I violationVENDOR CC PROHIBITED AREA AH
  376. InspectionBC INSP (likely: building-code inspection)
  377. L&I violationCAL LO (Commercial Activity License required)
  378. InspectionBC INSP (likely: building-code inspection)
  379. InspectionBC INSP (likely: building-code inspection)
  380. InspectionCI INSP
  381. L&I violationVIOL BC MESSAGE
  382. L&I violationDEALER IN PRECIOUS METALS LR
  383. L&I violationSCALE 1 TO 50 LBS LR
  384. L&I violationVIOL BC MESSAGE
  385. L&I violationVIOL BC MESSAGE
  386. L&I violationVIOL BC MESSAGE
  387. L&I violationSCALE 1 TO 50 LBS LR
  388. L&I violationDEALER IN PRECIOUS METALS LR
  389. L&I violationDEALER IN PRECIOUS METALS LR
  390. L&I violationSCALE 1 TO 50 LBS LO
  391. L&I violationVIOL BC MESSAGE
  392. InspectionBC INSP (likely: building-code inspection)
  393. InspectionBC INSP (likely: building-code inspection)
  394. InspectionBC INSP (likely: building-code inspection)
  395. InspectionBC INSP (likely: building-code inspection)
  396. InspectionBC INSP (likely: building-code inspection)
  397. InspectionBC INSP (likely: building-code inspection)
  398. InspectionBC INSP (likely: building-code inspection)
  399. InspectionBC INSP (likely: building-code inspection)
  400. PermitElectrical
  401. InspectionBC INSP (likely: building-code inspection)
  402. InspectionBC INSP (likely: building-code inspection)
  403. InspectionCI INSP
  404. InspectionCI INSP
  405. InspectionBC INSP (likely: building-code inspection)
  406. InspectionCI INSP
  407. InspectionBC INSP (likely: building-code inspection)
  408. InspectionCI INSP
  409. InspectionCI INSP
  410. InspectionCI INSP
  411. LicensePINALI INC: Food Establishment, Retail Permanent Location business license initially issued
  412. LicenseBIG BIG LOT INC: Vendor - Newsstand business license initially issued
  413. LicenseNITIN J DESAI: Vendor - Newsstand business license initially issued

Verify the public record

$0/year estimated property tax

2026 taxable assessment $0 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $13,140,900. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 882018800
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationFull assessment exemption shown

2026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Property report

Commercial property

Commercial, recorded in the City's commercial category. The public record and owner trail follow.

What it is
Commercial Com Condo 2 Sty Masonry
Owner
1100 Market St LP
$ / sq ft
$214 above the $151 median for 7,668 commercial parcels citywide
Corridor
Market East city commercial corridor
Licensed units
322 active rental license
Interior area
61,406 sqft
Lot size
11,377 sqft
Stories
2
Built
2016
Zoning
CMX5

Recorded owner

Who's behind it

1100 Market St LP · corporate / LLC owner

• Owns 4 properties across Philadelphia under this name, assessed at $142M combined
• Tax bills mail to 900 7th St Nw, Washington Dc, 20001 — outside Philadelphia
• Holds an active rental license for this address

Block context

1100 block of Market St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 1100 Market St  ·  1100s Market St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
IHB Center City Inc (Iron Hill Brewery & Restaurant)Active

Food Preparing and Serving (30+ SEATS) · Initial issue date Jun 30, 2026 · Filed expiration Jun 29, 2027

MULHERINS EM LLCInactive

Food Preparing and Serving (30+ SEATS) · Initial issue date Mar 13, 2024 · Terminal license date May 11, 2025

SGB Master Tenant, LLCActive

Food Preparing and Serving (30+ SEATS) · Initial issue date Mar 3, 2020 · Filed expiration Mar 2, 2027

WAWA #8112 (WAWA #8112)Closed

Food Establishment, Retail Perm Location (Large) · Initial issue date Nov 1, 2018 · Terminal license date Oct 31, 2021

WAWA #8112 (WAWA #8112)Closed

Food Preparing and Serving · Initial issue date Nov 1, 2018 · Terminal license date Oct 31, 2023

V & D JEWELRY INCORPORATED (PLATINUM JEWELERS)Inactive

Precious Metal Dealer · Initial issue date Oct 10, 2013 · Terminal license date Mar 1, 2015

PINALI INCInactive

Food Establishment, Retail Permanent Location · Initial issue date Apr 9, 2005 · Terminal license date Apr 30, 2014

BIG BIG LOT INCInactive

Vendor - Newsstand · Initial issue date Jan 28, 2005 · Terminal license date Jun 30, 2009

NITIN J DESAIInactive

Vendor - Newsstand · Initial issue date Sep 24, 2003 · Terminal license date May 30, 2015

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

1100 Market Street LP (The Ludlow )Active

Rental · Initial issue date Aug 27, 2019 · Filed expiration Aug 26, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Inferred from public records · 2025-07-29 through 2026-07-29

Food and drink at this property

1 possible-opening record signal in this 12-month window. These are classifications, not confirmed announcements.

Inference, not an opening announcement. Possible-opening classifications are inferences from public permit and license records, not confirmed opening announcements. A permit is authorization for a stated scope, not proof that work occurred or finished. A license is an L&I registration, not proof that a business is open or operating. Food and drink uses the seven exact L&I license types already used by BlockReport. The City record does not support a reliable restaurant, bar, and cafe split. License renewals do not create new events. The opening date is the earliest initial issue date for a deduped OPA parcel, normalized business identity, and license type. Sources: L&I building permits and L&I business licenses, data through Jul 29, 2026.

Open every source row 404 dated rows
  1. License issue eventIHB Center City Inc (Iron Hill Brewery & Restaurant): Food Preparing and Serving (30+ SEATS) business license initially issued

    License 1011575 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  2. PermitChange of Use

    Permit ZP-2026-007112 · Issued

    Retail Sales - Consumer Goods; Retail Sales - Wearing Apparel and Accessories

  3. PermitChange of Use

    Permit ZP-2026-006533 · Issued

    Retail Sales - Consumer Goods

  4. InvestigationL&I investigation

    Case CF-2025-131754 · PASSED

    The cited inspection visit was marked passed.

  5. InvestigationL&I investigation

    Case CF-2025-132126 · PASSED

    The cited inspection visit was marked passed.

  6. InvestigationL&I investigation

    Case CF-2026-006928 · PASSED

    The cited inspection visit was marked passed.

  7. InvestigationL&I investigation

    Case CF-2026-006934 · PASSED

    The cited inspection visit was marked passed.

  8. ViolationBENCHMARKING LATE

    Case CF-2026-006928 · Violation VI-2026-004439 · Code 9-3402(2) · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  9. ViolationBENCHMARKING LATE

    Case CF-2026-006934 · Violation VI-2026-004441 · Code 9-3402(2) · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  10. InvestigationL&I investigation

    Case CF-2026-006928 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  11. InvestigationL&I investigation

    Case CF-2026-006934 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  12. InvestigationL&I investigation

    Case CF-2025-131754 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  13. ViolationFIRE EXTINGUISHER HANGERS & BRACKETS

    Case CF-2025-131754 · Violation VI-2025-096716 · Code F-906.7 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  14. ViolationSMOKE CONTROL SYSTEM RECORDS

    Case CF-2025-131754 · Violation VI-2025-096711 · Code F-909.20.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  15. ViolationEXIT SIGN ILLUMINATION

    Case CF-2025-131754 · Violation VI-2025-096713 · Code F-1104.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  16. ViolationFIRE EXTINGUISHERS REQUIRED

    Case CF-2025-131754 · Violation VI-2025-096715 · Code F-906.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  17. ViolationHAZARD IDENTIFICATION SIGNS

    Case CF-2025-131754 · Violation VI-2025-096721 · Code F-5003.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  18. ViolationEXIT SIGN ILLUMINATION

    Case CF-2025-132126 · Violation VI-2025-095753 · Code F-1013.6.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  19. ViolationHAZARD IDENTIFICATION SIGNS

    Case CF-2025-132126 · Violation VI-2025-095758 · Code F-5003.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  20. ViolationFIRE EXTINGUISHERS REQUIRED

    Case CF-2025-132126 · Violation VI-2025-095754 · Code F-906.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  21. ViolationSUPPRESSION SYSTEM TESTING & MAINTENANCE

    Case CF-2025-132126 · Violation VI-2025-095752 · Code F-903.5 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  22. InvestigationL&I investigation

    Case CF-2025-132126 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  23. PermitAddition and/or Alterations

    Permit MP-2025-005772 · Completed

    FOR ALTERATION TO THE EXISTING HVAC SYSTEM TO ACCOMMONDATE NEW OFFICE LAYOUT AS PER APPROVED PLANS.

  24. PermitAlterations

    Permit PP-2025-014448 · Completed

    Provide labor and material to relocate [1] Electric Water Cooler with Bottle Filler - Furnish and install [1] Kitchen Sink - Provide labor and material to extend from existing sanitary, vent and domestic water to new fixture locations.

  25. PermitAddition and/or Alteration

    Permit EP-2025-009566 · Completed

    Demo Furnish and install 5 duplex outlets and 2 GFI's off of existing circuitry, relocate 6 2x2 and 4 linears Furnish and install 1 100 amp 480 volt panel

  26. PermitAddition and/or Alterations

    Permit FP-2025-002052 · Completed

    EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE (11) SPRINKLER HEADS ON THE GROUND FLOOR, PER NFPA13

  27. PermitAddition and/or Alteration

    Permit CP-2025-002988 · Completed

    FOR PARTIAL DEMO AND LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE AT GROUND FLOOR. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. ***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************

  28. PermitAlterations

    Permit PP-2025-005734 · Completed

    INSTALLATION OF NEW PLUMBING FIXTURES AND ALL ASSOCIATED PIPING. ALL FIXTURES SHALL BE PROVIDED WITH AIR GAPS AND BACKFLOW PREVENTERS WHERE REQUIRED. VENTING IN ACCORDANCE WITH SECTION 919 PHILADELPHIA SINGLE STACK VENT SYSTEM. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH 2018 PPC AND APPROVED PLANS.

  29. License terminal eventMULHERINS EM LLC: Food Preparing and Serving (30+ SEATS) business license marked inactive

    License 946670 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  30. PermitAddition and/or Alteration

    Permit EP-2025-004257 · Completed

    Furnish and install 4 duplex outlets and 3 208 outlets utilizing existing circuits.

  31. PermitAddition and/or Alteration

    Permit CP-2025-001562 · Completed

    FOR PARTIAL DEMO AND LEVEL II ALTERATIONS TO AN EXISTING STRUCTURE. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. ***************** SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ******************************************

  32. AppealZBA Permit Denial - Variance

    Appeal ZP-2024-001950 · Dismissed / Withdrawn · Withdrawn

    Related permit ZP-2024-001950 · PERMIT FOR THE INSTALLATION OF TWO (2) STATICALLY ILLUMINATED ACCESSORY PROJECTING SIGNS. SIZE AND LOCATION AS SHOWN IN PLANS.

  33. License issue eventMULHERINS EM LLC: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 946670 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  34. PermitChange of Use

    Permit ZP-2023-012840 · Issued

    Visitor Accommodations; Residential - Household Living - Multi-Family

  35. License terminal eventWAWA #8112 (WAWA #8112): Food Preparing and Serving business license marked closed

    License 793398 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  36. InvestigationL&I investigation

    Case CF-2023-084839 · PASSED

    The cited inspection visit was marked passed.

  37. ViolationNO SMOKING SIGNS

    Case CF-2023-084839 · Violation VI-2023-062526 · Code F-310.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  38. ViolationFIRE EXTINGUISHER CONSPICUOUS LOCATION

    Case CF-2023-084839 · Violation VI-2023-062524 · Code F-906.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  39. InvestigationL&I investigation

    Case CF-2023-084839 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  40. PermitAddition and/or Alterations

    Permit FP-2023-001726 · Completed

    EZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. INSTALL TWO (2) UL 300 FIRE SYSTEMS

  41. InvestigationL&I investigation

    Case CF-2022-124808 · PASSED

    The cited inspection visit was marked passed.

  42. PermitTemporary Tents and Canopies

    Permit OP-2022-000676 · Expired

    Install temporary tents at Canopy by Hilton located on the patio of the property of the hotel at 17 S 12th Street - does not impact the sidewalk or street as per 2018 Philadelphia Fire Code.

  43. PermitAddition and/or Alteration

    Permit CP-2022-007095 · Completed

    EZ STANDARD LIMITED COMMERCIAL ALTERATIONS & REPAIRS- For the limited demolition and commercial alterations without submitting plans as per attached standards. Deviations from these standards require submission of construction and site plans. SMALL REPAIR TO AN EXITING WALL SURFACE. NO FRAMING ALLOWED ON THIS PERMIT OR PLANS WILL BE REQUIRED.

  44. ViolationFACADES

    Case CF-2022-124808 · Violation VI-2022-093895 · Code PM15-315.2 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  45. InvestigationL&I investigation

    Case CF-2022-124808 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  46. PermitAddition and/or Alterations

    Permit MP-2022-004247 · Completed

    FOR THE INSTALLATION OF A NEW HVAC SYSTEMS, THREE (3) TYPE I COMMERCIAL KITCHEN HOODS, ONE (1) TYPE 2 COMMERCIAL KITCHEN HOOD, ASSOCIATED DUCT WORK, ROOFTOP UNITS, DUCTLESS SYSTEMS/APPLIANCES, AND REGISTERS/DIFFUSERS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL, PLUMBING, FIRE SUPPRESSION

  47. PermitAlterations

    Permit PP-2022-011722 · Completed

    COMPLETE PLUMBING FOR NEW PIZZA RESTAURANT

  48. InvestigationL&I investigation

    Case CF-2022-054499 · PASSED

    The cited inspection visit was marked passed.

  49. PermitAddition and/or Alterations

    Permit FP-2022-001988 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocation of 30 sprinkler heads

  50. ViolationINSPECTION, TESTING & MAINTENANCE

    Case CF-2022-054499 · Violation VI-2022-039946 · Code F-901.6 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  51. ViolationSECURING COMPRESSED CYLINDERS

    Case CF-2022-054499 · Violation VI-2022-039947 · Code F-5303.5.3 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  52. ViolationHAZARD IDENTIFICATION SIGNS

    Case CF-2022-054499 · Violation VI-2022-039948 · Code F-5003.5 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  53. ViolationEXIT SIGN ILLUMINATION

    Case CF-2022-054499 · Violation VI-2022-039945 · Code F-1013.6.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  54. InvestigationL&I investigation

    Case CF-2022-054499 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  55. PermitAddition and/or Alteration

    Permit EP-2022-003392 · Completed

    Doing a complete electrical commercial fit out for pizzeria according to drawings .2017 nec . **SEPARATE FIRE ALARM PERMIT NEEDED** FIRE ALARM COST WAS DEDUCTED FROM TOTAL $ AMOUNT OF THE SUBMITTED EXECUTED CONTRACT. AMENDMENT: Install fire alarm system PER APPROVED DRAWINGS-2017 NEC.2016 NFPA-72,2018 PHILA FIRE CODE.

  56. PermitAddition and/or Alteration

    Permit CP-2022-001495 · Completed

    FOR CHANGE OF OCCUPANCY AND LEVEL II ALTERATION TO INCLUDE STRUCTURAL WORK, NEW PARTITIONS, FIXTURES, FURINISHINGS, FINISHES AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR MEP AND FIRE SUPPRESSION WORK. Amendment 11/9/22 to update D&R form.

  57. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2022-002043 · Expired

    EZ INTERIOR DEMOLITION- For the interior demolition on non-bearing partition wall and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. Separate Streets Department permit required for sidewalk and street closures.

  58. License terminal eventWAWA #8112 (WAWA #8112): Food Establishment, Retail Perm Location (Large) business license marked closed

    License 793397 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  59. InvestigationL&I investigation

    Case CF-2021-015422 · PASSED

    The cited inspection visit was marked passed.

  60. InvestigationL&I investigation

    Case CF-2021-015422 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  61. PermitChange of Use

    Permit ZP-2021-005517 · Issued

    Eating and Drinking Establishments - Take-Out Restaurant; Eating and Drinking Establishments - Sit-Down Restaurant

  62. InvestigationL&I investigation

    Case CF-2021-015422 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  63. InvestigationL&I investigation

    Case CF-2021-015422 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  64. ViolationHIGH RISE LICENSE REQUIRED

    Case CF-2021-015422 · Violation VI-2021-012055 · Code FC-13-408.12 · COMPLIED

    Resolution: COMPLIED - LICENSE/CERTIFICATE/REPORT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  65. InvestigationL&I investigation

    Case CF-2020-059723 · PASSED

    The cited inspection visit was marked passed.

  66. InvestigationL&I investigation

    Case CF-2020-059723 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  67. ViolationNEW USE

    Case CF-2020-059723 · Violation VI-2020-033796 · Code A-301.1/65 · COMPLIED

    Resolution: COMPLIED - PERMIT OBTAINED City marked this violation complied with; check the resolution date and live case for what was accepted.

  68. PermitAddition and/or Alteration

    Permit EP-2020-001077 · Completed

    Furnish and install lighting and security conduits and inverter for EM lighting also sign power.All work to be done according to the 2107 NEC.

  69. PermitChange of Use

    Permit ZP-2020-000071 · Issued

    Eating and Drinking Establishments - Take-Out Restaurant

  70. InvestigationL&I investigation

    Case 695698 · PASSED

    The cited inspection visit was marked passed.

  71. PermitAddition and/or Alteration

    Permit 1045736 · Expired

    FOR EXTERIOR ALTERATIONS TO INCLUDE THE DEMOLITION AND RECONSTRUCTION OF AN EXISTING SUBWAY ENTRANCE HEADHOUSE WITH GLASS AND STEEL ENCLOSURE, AS PER APPROVED PLANS. **STREETS DEPARTMENT PERMIT REQUIRED PRIOR TO START OF WORK**

  72. PermitSign

    Permit 1049275 · COMPLETED

    FOR THE REMOVAL OF THREE (3) ACCESSORY DOUBLE-FACED PROJECTING SIGNS ("D", "E", & "F") ATTACHED TO THE UNDERSIDE OF AN EXISTING MARQUEE AND FOR THE INSTALLATION OF ONE (1) STATIC INTERNALLY ILLUMINATED MARQUEE SIGN ("L") AND TWO (2) NON-ILLUMINATED PROJECTING SIGNS ("L1" & "L2") ATTACHED TO THE UNDERSIDE OF THE EXISTING MARQUEE AS PER PLANS. NO OTHER WORK THIS PERMIT. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  73. License issue eventSGB Master Tenant, LLC: Food Preparing and Serving (30+ SEATS) business license initially issued

    License 838931 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  74. PermitNew Construction

    Permit 1045267 · Completed

    INSTALL 1-208/120 VOLT 3 PH 150 AMP PANEL R 132--INSTALL 1-45 KVA TRANSFORMER AND METER AS PER DRAWINGS--INSTALL LIGHTING, RECEPTACLES, HVAC FEEDERS AS PER 2017 NEC. INSTALL FIRE ALARM AS PER NFPA 72

  75. InvestigationBC INSP (likely: building-code inspection)

    Case 695698 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  76. PermitNew Construction

    Permit 1044661 · Expired

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE TWELVE(12) HEADS OFF OF EXISTING SYSTEM TO ACCOMMODATE NEW LAYOUT.

  77. PermitNew Construction

    Permit 1039968 · Expired

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS AND APPLIANCES WITH ASSOCIATED DUCTWORK FOR A BUSINESS OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  78. PermitAlterations

    Permit 1039995 · Expired

    FURNISH AND INSTALL SANITARY SANITARY VENT AND DOMESTIC WATER PIPING TO NEW FIXTURE FURNISH AND INSTALL 1WC 1LAV 1FD AND EWH AS PER 2004 PPC

  79. PermitElectrical

    Permit 1032900 · COMPLETED

    FURNISH AND INSTALL NEW FIRE ALARM SYSTEM SPEAKERS/STROBES AND STROBES AND (1) NAC 30 PANEL + 4 PULL STATIONS (1) SMOKE DETECTOR + 1 MONITOR MODULE AS PER THE 2017 NEC, 2016 NFPA-72. (C.C. DIST)

  80. PermitElectrical

    Permit 1032891 · COMPLETED

    FURNISH AND INSTALL (18) CAT 6 CABLES BACK TO I T CLOSET

  81. PermitAddition and/or Alteration

    Permit 1026166 · Completed

    LEVEL II INTERIOR ALTERATIONS (NO CHANGE OF OCCUPANCY) TO THE GROUND FLOOR( TENANT SPACE # R-132) OF AN EXISTING HIGH-RISE BUILDING. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES AND FURNISHINGS THROUGHOUT THE DESIGNATED FLOOR. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. **IEBC 2018 **SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL,ELECTRICAL OR PLUMBING WORK**.

  82. PermitElectrical

    Permit 1027594 · COMPLETED

    F & I NEW LTS SW RECEPS AND PANELS & TRANSFORMERS AS PER THE 2017 NEC.(CC DIST.) NO FIRE ALARM WORK.

  83. PermitSuppression

    Permit 1026542 · COMPLETED

    RELOCATE 46 EXISTING SPRINKLER HEADS O THE GROUND FLOOR TO ACCOMMODATE TENANT LAYOUTS AS PER NFPA NO. 13 AND ALL LOCAL CODES.

  84. PermitPlumbing

    Permit 1021806 · COMPLETED

    DOG DAYCRE TOILETS FLOOR DRAINS LAVS WATER HEATER SHOWERS. INSTALLATION SHALL COMPLY WITH THE 2004 PHILADELPHIA PLUMBING CODE

  85. PermitMechanical

    Permit 1013438 · COMPLETED

    PARTIAL DEMOLITION OF EXISTING DUCTWORK AND MECHANICAL PIPING PER PLANS; INSTALLATION OF NEW DUCTWORK, GRILLES, REGISTERS, DIFFUSERS, ASSOCIATED PIPING AND OTHER EQUIPMENT / DEVICES PER PLANS .TO ACCOMMODATE THE 1ST FLOOR( SPACE R-107) OF AN EXISTING HIGH-RISE BUILDING.** ALL WORK TO BE PERFORM SAS PER APPROVED PLANS**SEPARATE PERMITS REQUIRED FOR ALL ELECTRICAL AND PLUMBING WORK**

  86. PermitMajor alteration

    Permit 1011506 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS TO INCLUDE A CHANGE OF OCCUPANCY FOR RENOVATIONS TO SPACE# R-107 LOCATED ON THE FIRST FLOOR OF AN EXISTING HIGH-RISE BUILDING AS PER APPROVED PLANS**EXISTING BUILDING FULLY SPRINKLERED **2018** **SEPARATE PERMITS REQUIRED FOR ANY MEP & FIRE SUPPRESSION WORK**NO SIGN APPROVED ON THIS APPLICATION**

  87. PermitAdministrative

    Permit 1010253 · COMPLETED

    AMEND PERMIT AP#980955 FOR UPDATED ARCHITECTURAL WORK AS PER APPROVED PLANS AND LETTER. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK.

  88. PermitAdministrative

    Permit 1016346 · COMPLETED

    AMEND PERMIT AP#982077 FOR MECHANICAL CHANGES AS PER APPROVED PLANS AND LETTER. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  89. PermitElectrical

    Permit 1013723 · COMPLETED

    5 SPEAKERS,1 AMP,1 MUSIC PLAYER AND 3 VC'S PER 2017 NEC (BANK)

  90. PermitNew Construction

    Permit 1000120 · Completed

    TO INSTALL A NEW BURGULAR ALARM SYSTEM WITH A DMP XR550E PANEL, DOOR CONTACTS, KEYPADS, HOLD UP BUTTONS AND MOTION DETECTORS. AS PER 2017 NEC

  91. PermitElectrical

    Permit 998445 · COMPLETED

    FIT OUT OF CHASE BANK FIRE ALARM IN AN EXISTING BUILDING (MIXED USE) PER NFPA 72

  92. License issue event1100 Market Street LP (The Ludlow ): High Rise L&I license filing initially issued

    License 822825 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  93. License issue event1100 Market Street LP (The Ludlow ): Rental landlord or residential registration initially issued

    License 822158 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  94. PermitUse

    Permit 1003273 · COMPLETED

    USE CHANGE TO SPACE R-107: ANIMAL SERVICES AND RETAIL SALE OF PETS AND PET SUPPLIES WITH ALL OTHE USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE.

  95. PermitSign

    Permit 995381 · COMPLETED

    FOR THE INSTALLATION OF ONE (1) ACCESSORY, DOUBLE-FACED, STATICALLY ILLUMINATED PROJECTING SIGN ("BL.1" ON PLANS) ATTACHED TO THE UNDERSIDE OF A PREVIOUSLY APPROVED MARQUEE (SEE AP#873170), FOR A RETAIL TENANT AT SPACE R102 ON THE GROUND FLOOR FACING MARKET STREET, AS PER PLANS; NO OTHER WORK ON THIS PERMIT; SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  96. PermitElectrical

    Permit 991916 · COMPLETED

    200AMP 3 PHASE 480VOLT SERVICE AND FITOUT BRANCH WIRING, LIGHTING & LIGHTING CONTROL AND HVAC HOOKUP ONLY AS PER NEC 2017

  97. PermitZoning/use

    Permit 952219 · COMPLETED

    *---FOR ERECTION OF ONE (1) PROJECTING SIGN DOUBLE FACED ILLUMINATED BLADE SIGN UNDER STORE ENTRANCE CANOPY (1'-8" HIGH BY 1'-9" WIDE). SIZE AND LOCATION AS SHOWN ON THE APPLICATION. SIGN ACCESSORY TO RETAIL SALES OF OF HOME GOODS AND CLOTHING AND ALL OTHER USES AS PREVIOULY APPROVED IN AN EXISTING STRUCTURE.

  98. ViolationPERM Z- NEW USE

    Case 695698 · Violation 211968404 · Code A-301.1/65 · CLOSED

    Resolution: CLOSED - ADMINISTRATIVELY City marked the record closed; open the case for the closing reason.

  99. ViolationVIOL BC MESSAGE

    Case 695700 · Violation 5108658 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  100. InvestigationBC INSP (likely: building-code inspection)

    Case 695700 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  101. InvestigationBC INSP (likely: building-code inspection)

    Case 695698 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  102. PermitSuppression

    Permit 990789 · COMPLETED

    FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  103. PermitMajor alteration

    Permit 980955 · COMPLETED

    INTERIOR ALTERATIONS (PRESCRIPTIVE METHOD) AND STRUCTURAL WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK.

  104. PermitMechanical

    Permit 982077 · COMPLETED

    FOR THE INSTALLATION OF MECHANICAL WORK TO INCLUDE REGISTERS/DIFFUSER, SUPPLY/EXHAUST DUCTWORK, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL AND PLUMBING WORK.

  105. PermitUse

    Permit 980952 · COMPLETED

    USE PERMIT FOR FINANCIAL SERVICES (BANK/FINANCIAL INSTITUTION) FOR CHASE BANK LOCATED ON GROUND FLOOR (SPACE R-103)

  106. InvestigationCI INSP

    Case 678947 · PASSED

    The cited inspection visit was marked passed.

  107. ViolationSTORAGE EQUIPMENT ROOMS

    Case 678947 · Violation 4996047 · Code FC-13-315.23 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  108. ViolationMEANS OF EGRESS OBSTRUCTION

    Case 678947 · Violation 4996045 · Code FC-13-1003.3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  109. ViolationLABELING

    Case 678947 · Violation 4996048 · Code FC-13-605.31 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  110. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 678947 · Violation 4996049 · Code FC-13-915.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  111. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 678947 · Violation 4996050 · Code FC-13-915.1A · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  112. ViolationCEILING CLEARANCE

    Case 678947 · Violation 4996046 · Code FC-13-315.21 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  113. InvestigationCI INSP

    Case 678947 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  114. PermitSuppression

    Permit 930016 · COMPLETED

    EXTENSION OF EXISTING NFPA 13 SPRINKLER SYSTEM TO SERVE NEW 2ND FLOOR MEZZANINE AS PART OF A FITNESS CENTER AS PER APPROVED PLANS. SEE A/P 839581 FOR BASE BUILDING SPRINKLER INSTALLATION. ALL WORK TO BE PERFORMED BY A LICENSED PHILADELPHIA FIRE SUPPRESSION CONTRACTOR.

  115. PermitZoning/use

    Permit 893181 · COMPLETED

    INSTALL 5 D/F FLAG MOUNTED PANELS ON 12 STREET ELEVATION 24X11-5 =22.83 SF..INSTALL 3 FLAG MOUMTED PANELS ON EAST MARKET ST ELEVATION 24X11.5=22.83 INSTALL 1 SET OF CHANNEL LETTERS ON RACEWAY ON 12 ST ELEVATION 18X21-2 7/8= 31.82 SF

  116. PermitSign

    Permit 893182 · COMPLETED

    FOR PROPOSED EIGHT (8) DOUBLE-FACED, NON-ILLUMINATED PROJECTING SIGN INSTALLATIONS ON EXISTING STRUCTURES. SIZE AND LOCATION AS PER APPROVED PLANS.

  117. PermitSuppression

    Permit 946588 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF 45 SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  118. AppealZoning board appeal

    Appeal 35789 · OPEN · Granted

    Related permit 893181 · PERMIT FOR THE INSTALLATION OF EIGHT (8) DOUBLE-FACED, NON-ILLUMINATED PROJECTING SIGNS AND ONE (1) INTERNALLY-ILLUMINATED FLATWALL SIGN ACCESSORY TO THE USE OF PERSONAL SERVICES (FITNESS CENTER) WITH ALL OTHER USES AS PREVIOUSLY APPROVED.

  119. PermitNew Construction

    Permit 925489 · Completed

    REFERENCE ELECTRICAL PERMIT 912441. PULL FIRE ALARM WIRE FOR ALL NECESSARY DEVICES SUCH AS SMOKE DETECTORS AND PULL STATIONS.

  120. PermitSign

    Permit 918965 · COMPLETED

    FOR THE INSTALLATION OF THREE (3) FLATWALL SIGNS, ACCESSORY TO A TAKEOUT RESTAURANT, AS PER APPROVED PLANS.

  121. PermitZoning/use

    Permit 918964 · COMPLETED

    FOR THE ERECTION OF THREE(3) FLATWALL SIGNS WITH LOGO ACCESSORY TO TAKE-OUT RESTAURANT AT SPACE# R-101 AS PART OF EXISTING STRUCTURE IN THE SAME BUILDING WITH ALL OTHER USES A SPREVIOUSLY APPROVED.SIZE AND LOCATION AS SHOWN IN THE APPLICATION.

  122. PermitElectrical

    Permit 898369 · COMPLETED

    TEMP LIGHTING & POWER INSTALL NEW 600AMP ELECTRIC PANEL ,3 SECTIONS, FEEDER BY OTHERS, NEW LIGHTING FIXTURES, BRANCH CIRCUITS & SWITCHES & RECEPTACLES,INSTALL POWER TO ALL NEW KITCHEN & HVAC EQUIPMENT. AS PER 2008 NEC (CC DISTRICT)TIE IN EXISTING FIRE ALARM DEVICES & INSTALL NEW DEVICES AS PER NFPA 72

  123. PermitSign

    Permit 925106 · COMPLETED

    FOR THE INSTALLATION OF ONE (1) INTERNALLY-ILLUMINATED FLATWALL SIGN INSTALLATION. SIZE AND LOCATION AS PER APPROVED PLANS. **SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.**

  124. PermitZoning/use

    Permit 925105 · COMPLETED

    FOR THE INSTALLATION OF ONE (1) INTERNALLY-ILLUMINATED, FLATWALL SIGN ACCESSORY TO THE USE OF PERSONAL SERVICES. SIZE AND LOCATION AS PER APPROVED PLANS.

  125. PermitElectrical

    Permit 912441 · COMPLETED

    INSTALL WIE & DEVICE FOR LIGHTS, RECEPTACELS, SWITCHES, OCCUPANCY SENSORS AS PER 2008 NEC (CC DISTRICT) FIRE ALARM ON A SEPARATE PERMIT

  126. License issue eventWAWA #8112 (WAWA #8112): Food Establishment, Retail Perm Location (Large) business license initially issued

    License 793397 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  127. License issue eventWAWA #8112 (WAWA #8112): Food Preparing and Serving business license initially issued

    License 793398 · Closed

    License event. Registration does not prove present operation or storefront occupancy.

  128. PermitAdministrative

    Permit 923063 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  129. PermitAdministrative

    Permit 923084 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  130. PermitPlumbing

    Permit 903580 · COMPLETED

    ALTERATIONS: INTERIOR PLUMBING;RESTAURANT, INTERIOR SPACE R-101 (DISTRICT TACO);FIT-OUT OF A TENANT SPACE TO INCLUDE INSTALLATION OF ACCESSIBLE RESTROOM,; 2 WATER CLOSETS, 2 LAVY SINKS, 7 FLOOR DRAINS, 1 MOP SINK, 1-3 COMPARTMENT SINK, 3 FLOOR SINKS, 3 HAND SINKS, 5 HUB DRAINS, & 1 PREP SINK - THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  131. PermitElectrical

    Permit 908243 · COMPLETED

    FIT OUT NEW FITNESS CENTER, NEW 600AMP SERVICE,LIGHTING,POWER,LOW VOLTAGE AD CONNECTION TO NEW MECHANICAL EQUIPMENT PER 2008 NEC (FITNESS CENTER)

  132. PermitSuppression

    Permit 919138 · COMPLETED

    INSTALL ONE(1) ANSUL R-102 6.0 GALLON WET CHEMICAL SUPPRESSION SYSTEM- FOR THE INSTALLATION OF NEW WET CHEMICAL KITCHEN FIRE SUPPRESSION SYSTEM AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  133. PermitPlumbing

    Permit 916850 · COMPLETED

    FURNISH AND INSTALL SANITARY AND DOMESTIC WATER PIPE TO NEW PLUMBING FIXTURES,FURNISH AND INSTALL 1-WATER CLOSET,1-LAV AND 1-FLOOR DRAIN IN NEW ADA BATHROOM AND 1-6 GALLON WATER HEATER.THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004

  134. PermitSuppression

    Permit 916494 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)-RELOCATION OF EIGHT(8) SPRINKLER HEADS FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  135. PermitMechanical

    Permit 907360 · COMPLETED

    FOR THE INSTALLATION OF A MECHANICAL SYSTEM TO INCLUDE REGISTERS/DIFFUSERS, SUPPLY/EXHAUST DUCTWORK, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL AND PLUMBING WORK.

  136. PermitNew construction

    Permit 873898 · COMPLETED

    CORE AND SHELL WORK INCLUDING ACCESS TO BASE BUILDING INFASTURE AND A NEW EGRESS STAIR FOR A FUTURE TENANT FIT OUT AS PER PLANS.

  137. PermitMechanical

    Permit 898742 · COMPLETED

    FOR THE INSTALLATION OF TWO (2) TYPE 1 COMMERCIAL KITCHEN HOOD , SUPPLY/EXHAUST DUCTWORK, AND EXHAUST FAN AS PER APPROVED PLANS. EXHAUST FAN LOCATION SHALL COMPLY WITH SECTION 506.3.12 OF THE 2009 IMC. SEE AP#853831 FOR MECHANICAL PERMIT.

  138. PermitZoning/use

    Permit 840685 · COMPLETED

    FOR THE ERECTION OF ONE (1) DOUBLE-FACE, NON-ILLUMINATED PROJECTING SIGN. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS. FOR USE AS SIGNAGE ACCESSORY TO PREVIOUSLY APPROVED RETAIL SALES OF WEARING APPAREL & ACCESSORIES IN SPACE R102 IN THE SAME BUILDING WITH OTHER PREVIOUSLY APPROVED USES AND SIGNS.

  139. PermitPlumbing

    Permit 884681 · COMPLETED

    INSTALL 1 GREASE TRAP 1 HAND SINK 2 FLOOR SINKS AND 1 WATER HEATER (FOOD SHOP)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  140. PermitElectrical

    Permit 894190 · COMPLETED

    RELOCATE 1-EXISTING PULLSTATION AND SPEAKER STROBE ADD 1-STROBE ONLY IN HANDICAP & EMPLOYEE WORK AREA AS PER NFPA 72 CC DISTRICT

  141. InvestigationBP_BLDG

    Case 625995 · PASSED

    The cited inspection visit was marked passed.

  142. PermitAdministrative

    Permit 892936 · COMPLETED

    AMENDMENT TO PREVIOUSLY APPROVED PERMIT A/P #873170 TO MOUNT THE SINGLE FACED LED ILLUMINATED CHANNEL LETTERS ON A RACEWAY RATHER THAN DIRECTLY TO THE CANOPY DUE TO EXISTING CONDITIONS. "TJ MAXX"2'-7.5"HIGH BY 12'-2 7/8"WIDE = 32.12 SQFT.

  143. PermitMechanical

    Permit 888404 · COMPLETED

    INSTALLATION OF AN HVAC SYSTEM IN SPACE R-134 AS PER APPROVED PLANS.

  144. PermitSuppression

    Permit 894649 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  145. PermitElectrical

    Permit 885141 · COMPLETED

    ON AN EXISTING 100AMP SERVICE,RELOCATE 1-100AMP PANEL,INSTALL 25-LIGHT FIXTURES,RUN 8-CIRCUITS FOR ICE CREAM EQUIPMENT FROM EXISTING PANEL AS PER 2008 NEC (CC DISTRICT)

  146. PermitAdministrative

    Permit 892239 · COMPLETED

    TEMO CO FOR 1ST FLOOR. REFER TO PERMIT NUMBER 728204

  147. PermitSuppression

    Permit 892400 · COMPLETED

    WE WILL BE RELOCATIONG (10) SPRINKLER HEADS IN LITTLE BABYS -EAST MARKET, WEST PODIUM

  148. PermitMajor alteration

    Permit 870757 · COMPLETED

    FOR THE FIT-OUT OF A TENANT SPACE TO INCLUDE INSTALLATION OF ACCESSIBLE RESTROOM, ACCESSIBLE SERVICE COUNTER, INTERIOR PARTITION WALL INSTALLATION, AND WALL/FLOOR/CEILING FINISHING. **SEPARATE PERMITS REQ'D FOR ELECTRICAL, PLUMBING, MECHANICAL, AND FIRE SUPPRESSION SYSTEM INSTALLATIONS.**

  149. PermitMechanical

    Permit 873769 · COMPLETED

    FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE EXHAUST FANS, WATER-SOURCED HEAT PUMPS, VARIABLE DAMPERS, GRILLES/REGISTERS/DIFFUSERS, REFRIGERANT PIPING, AND ASSOCIATED DUCTWORK. **SEPARATE PERMITS REQUIRED FOR KITCHEN HOOD EXHAUST SYSTEM INSTALLATION.**

  150. PermitAdministrative

    Permit 728204 · COMPLETED

    AMEND PERMIT #586949 FOR REVISIONS TO THE WEST PODIUM FACADE, FACADE SUPPORT, AND FOOTPRINT AS WELL AS BASE BLDG MODIFICATIONS AND STRUCTURAL REVISIONS FOR A FUTURE RESIDENTIAL TOWER (WEST TOWER). SEE PERMIT #727764 FOR WEST TOWER OVERBUILD.

  151. PermitPlumbing

    Permit 877343 · COMPLETED

    FURNISH AND INSTALL SANITARY,SANITARY VENT AND DOMESTIC WATER PIPING FOR NEW FITNESS CLUB,LOCKER ROOMS,BATHROOMS AND BREAK ROOM.FURNISH AND INSTALL WATER CLOSETS,LAVS,SHOWERS AND FLOOR DRAINS (FITNESS CTR)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  152. PermitAdministrative

    Permit 865613 · COMPLETED

    AMEND PERMIT NUMBER 727764 TO REVISE THE OCCUPANCY ON LEVELS 4-8 FROM R2 RESIDENTIAL TO R1 EXTENDED STAY HOTEL. REVISIONS INCLUDE ALTERATIONS TO NON-BEARING PARTITIONS WITHIN EXISTING DWELLING UNITS TO COMPY WITH ACCESSIBILITY PROVISIONS FOR THE NEW OCCUPANCY.

  153. AppealBuilding standards appeal

    Appeal 33677 · CLOSED · APPROVED

    Related permit 728204 · ON 04/23/2018, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #728204.

  154. PermitMajor alteration

    Permit 863650 · COMPLETED

    FOR THE INTERIOR FITOUT OF A TENANT SPACE FOR THE USE OF A PREPARED FOOD SHOP, ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUHGOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  155. PermitZoning/use

    Permit 876396 · COMPLETED

    FOR THE ERECTION OF A MEZZANINE OPEN TO THE SECOND FLOOR LEVEL WITH NO CHANGE IN HEIGHT AND/OR OCCUPIED AREA OF THE EXISTING STRUCTURE.SIZE AND LOCATION AS SHOWN PER APPLICATION. TENANT SPACE FOR USE AS A PERSONAL SERVICE ON THE FIRST AND SECOND FLOOR LEVEL WITH ACCESSORY PREPARED FOOD SHOP ON THE FIRST FLOOR LEVEL

  156. PermitMajor alteration

    Permit 851662 · COMPLETED

    FOR LEVEL II ALTERATIONS TO INCLUDE THE ERECTION OF A MEZZANINE ABOVE THE SECOND FLOOR LEVEL, ENTIRE TENANT SPACE FOR USE AS A FITNESS CENTER WITH ACCESSORY PREPARED FOOD SHOP ON THE FIRST FLOOR LEVEL. ALTERATIONS TO ALSO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBLE IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. TENANT SPACE TO BE FULLY SPRINKLERED. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

  157. PermitSign

    Permit 873170 · COMPLETED

    INSTALL (1) SET OF SINGLE FACED, LED ILLUMINATED CHANNEL LETTERS ON THE ENTRANCE CANOPY OVER THE DOORS ON THE FRONT ELEVATION, 2'-75" HIGH BY 12'-2 7/8" WIDE= 32.12 SQ.FT.

  158. PermitPlumbing

    Permit 852207 · COMPLETED

    NEW CONSTRUCTION: INTERIOR PLUMBING;MIXED-USE HIGH-RISE STRUCTURE; INITIAL TENANT FITOUT OF TENANT SPACE R-102/202; 1MP 4FD 3WC 1URINALS 4LAVS 1WC 1EYE WASH SINK 1 LOUNGE SINK-THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  159. InvestigationBP_BLDG

    Case 625995 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  160. PermitZoning/use

    Permit 840684 · COMPLETED

    FOR THE ERECTION OF ONE INTERNALLY ILLUMINATED FLAT WALL SIGN, SIZE AND LOCATION AS SHOWN PER APPLICATION/PLAN. SIGNS ACCESSORY TO PREVIOUSLY APPROVED USE FOR A RETAIL SALE OF WEARING APPAREL AND ACCESSORIES.

  161. PermitUse

    Permit 870709 · COMPLETED

    USE TO COMMERCIAL SERVICES TAKE-OUT/SIT DOWN RESTAURANT IN SPACE R-101. NO CHANGE TO HEIGHT OR AREA. NO SIGNS THIS PERMIT

  162. PermitMechanical

    Permit 863972 · COMPLETED

    INSTALLATION OF CONDENSER WATER DISTRIBUTION PIPING FOR FUTURE TENANTS ON THE L-1 AND L-2 LEVELS OF A NEW CONSTRUCTION BUILDING AS PER APPROVED PLANS.

  163. PermitAdministrative

    Permit 859069 · COMPLETED

    ADMIN PERMIT TO AMEND PERMIT #727764 TO INCLUDE INSTALLATION OF ACCESS PANELS IN CEILING MEMBRANE OF A NON FIRE RATED FLOOR/CEILING ASSEMBLY. ACCESS PANELS TO BE SIZED TO ALLOW FOR MAINTENANCE AND INSPECTION OF ABOVE CEILING MOUNTED HVAC UNITS. FUTURE REMOVAL AND/OR REPLACEMENT OF UNITS WILL REQUIRE REMOVAL OF A PORTION OF THE GWB CEILING MEMBRANE WITHOUT REMOVAL OR CUTTING OF ANY FRAMING MEMBERS.

  164. PermitAdministrative

    Permit 854240 · COMPLETED

    TO AMEND PREVIOUSLY ISSUED PERMIT AP#628730 (FOR INSTALLATION OF MECHANICAL SYSTEMS WITHIN THE SUB-BASEMENT, PARKING GARAGE, GROUND LEVEL, 1ST/2ND FLRS, AND WITHIN THE EAST TOWER, THROUGH TO 18TH FLR/PENTHOUSE), TO CORRECT THE ADDRESS FROM 1101 MARKET TO 1100 MARKET ST, AS PER REVISED COVER SHEET AND MECHANICAL DETAILS SHEET; NO OTHER CHANGES ON THIS PERMIT.

  165. PermitSuppression

    Permit 867587 · COMPLETED

    FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  166. PermitSuppression

    Permit 867586 · COMPLETED

    FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARDS. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS.

  167. PermitSign

    Permit 863389 · COMPLETED

    INSTALL ONE FLATWALL AND TWO WINDOW SIGNS AS SHOWN ON PLANS.

  168. PermitAdministrative

    Permit 864834 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY: LOADING DOCK, BACK OF HOUSE SUPPORTS, EAST PORTION OF SUB BASEMENT, LEVELS G THROUGH 2 COMMON AREAS

  169. PermitPlumbing

    Permit 864700 · COMPLETED

    INSTALL SANITARY, SANITARY VENT AND DOMESTIC WATER PIPING TO NEW POWDER ROOM. INSTALL WATER CLOSET, LAV AND FLOOR DRAIN

  170. PermitElectrical

    Permit 860812 · COMPLETED

    TENANT FIT OUT OF AN AT&T RETAIL STORE INCLUDING INSTALLATION OF TELE/DATA CABLE AND DEVICES PER 2008 NEC (RETAIL)

  171. PermitAdministrative

    Permit 863029 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY RETAIL SPACE # 104 (AT&T)

  172. PermitUse

    Permit 859147 · COMPLETED

    PROPOSED INTERIOR FIT-OUT FOR PREPARED FOODS/ICE CREAM SHOP. NO PREP KITCHEN-ICE CREAM BROUGHT FROM OFFSITE LOCATION

  173. PermitNew construction

    Permit 841504 · COMPLETED

    CREATION OF COMMON EXIT ACCESS CORRIDOR TO CONNECT EXISTING TENANT SPACES WITHIN GROUND LEVEL OF A NEW CONSTRUCTION BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR FINAL FIT OUT AND CERTIFICATE OF OCCUPANCY. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  174. PermitMajor alteration

    Permit 841508 · COMPLETED

    CORE AND SHELL IMPROVEMENTS TO INCLUDE ACCESS TO BASE BUILDING INFRASTRUCTURE. LIMITED TENANT FIT OUT (TENANT SPACE R-134) INCLUDING TENANT TOILET ROOM. SEPARATE PERMIT REQUIRE FOR PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION AND CERTIFICATE OF OCCUPANCY.

  175. ViolationARCHITECT/ENGINEER SERVICES

    Case 625995 · Violation 4660582 · Code A-304.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  176. ViolationPERMB- WORK NOT SAME AS PERMIT

    Case 625995 · Violation 4660581 · Code A-302.10/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  177. InvestigationBP_BLDG

    Case 625995 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  178. PermitMechanical

    Permit 853831 · COMPLETED

    FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE INSTALLATIONG OF WATER SOURCE HEAT PUMPS, VAV TERMINAL BOXES, UNIT HEATERS, GRILLES/DIFFUSERS/REGISTERS, EXHAUST FANS AND ASSOCIATED DUCTWORK.

  179. PermitAdministrative

    Permit 855790 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  180. PermitElectrical

    Permit 846776 · COMPLETED

    TENANT FIT OUT OF AN AT&T RETAIL STORE. THE WORK WILL INCLUDE REMOVAL, REPLACEMENT AND ADDITION OF NEW FIRE ALARM DEVICES A PER PLANS PER 2008 NEC (RETAIL).

  181. PermitSuppression

    Permit 854115 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  182. PermitNew construction

    Permit 832463 · COMPLETED

    FOR THE INITIAL TENANT FITOUT OF TENANT SPACE R-102/202. ALTERATIONS TO ACCOMMODATE RETAIL USE AND TO INCLUDE ERECTION OF PARTITIONS, FURNISHINGS, FINISHES AND PLUMBING FIXTURES. SEPARATE PERMIT REQUIRED FOR PLUMBING, MECHANICAL AND ELECTRICAL WORK.

  183. InvestigationBP_BLDG

    Case 616430 · PASSED

    The cited inspection visit was marked passed.

  184. PermitAdministrative

    Permit 775144 · COMPLETED

    TO AMEND NEW CONSTRUCTION PERMIT #586949 TO INCLUDE DIGITAL SIGNAGE AT WEST PODIUM OF 1100 MARKET ST.

  185. PermitAdministrative

    Permit 844829 · COMPLETED

    AMEND BUILDING PERMIT AP#829141 AS PER CLOUDED REVISIONS AND ATTACHED LETTER. SEPARATE PERMIT REQUIRED FOR ANY ELECTRICAL AND PLUMBING CHANGES.

  186. PermitAdministrative

    Permit 842570 · COMPLETED

    AMEND BUILDING PERMIT AP#810938 AS PER CLOUDED REVISIONS AND ATTACHED LETTER. SEPARATE PERMIT REQUIRED FOR ANY MEP CHANGES.

  187. PermitUse

    Permit 839495 · COMPLETED

    FOR THE REDUCTION OF TWO(2)COMPACT ACCESSORY PARKING SPACES AT CELLAR FOR A TOTAL OF ONE-HUNDRED SEVENTY(170)ACCESSORY PARKING SPACES INCLUDING WITH SIX(6) H/C SPACES,ONE(1) VAN H/C SPACE;FOR A RETAIL SALE OF WEARING APPAREL AND ACCESSORIES AT SPACE# R-102 AT FIRST FLOOR AND SPACE# R-202 AT SECOND FLOOR IN THE SAME BUILDING WITH FIVE-HUNDRED SIXTY-TWO(562) DWELLING UNITS AND ALL RETAIL SPACES AS PREVIOUSLY APPROVED(SEE APP# 698338.NO SIGN ON THIS APPLICATION.

  188. PermitSuppression

    Permit 839581 · COMPLETED

    INSTALLATION OF (531) SPRINKLERS AND ASSOCIATED PIPING AT EAST MARKET COMPLEX, WEST PODIUM IN ACCORDANCE WITH NFPA 13 WITH EXISTING 8" BACKFLOW PREVENTION ASSEMBLY AS PER SUBMITTED PLANS.

  189. PermitElectrical

    Permit 839398 · COMPLETED

    INSTALLATION OF LIGHTING AND LIGHTING CONTROL IN THE LOBBY GROUND AND 1ST FLOOR AND 3RD FLOOR AMENITY SPACE (MIXED USE)

  190. PermitElectrical

    Permit 834125 · COMPLETED

    TENANT FIT OUT OF AN AT&T RETAIL STORE. THE WORK WILL INCLUDE NEW LIGHTING AND RECEPTACLES THROUGHOUT STORE. THE ELECTRICAL SERVICE AND PANEL ARE EXISTING.WE WILL BE ADDING A 100A MLO PANEL TO THE EXISTING PANEL H PER 2008 NEC (RETAIL)

  191. PermitAdministrative

    Permit 840897 · COMPLETED

    TEMPORARY CERTIFICATE OF OCCUPANCY

  192. ViolationWORKMANLIKE- BUILDING CODE

    Case 616430 · Violation 4541665 · Code A-104.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  193. ViolationLISTED CONDIT DOES NOT COMPLY

    Case 616430 · Violation 4541666 · Code A-501.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  194. InvestigationBP_BLDG

    Case 616430 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  195. PermitMajor alteration

    Permit 810938 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS AND STRUCTURAL WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK. SPECIAL INSPECTOR FOR POST INSTALLED CONCRETE ANCHORS: BEN RUMEAU (EIT) UNDER THE DIRECT SUPERVISION OF JASON JOINES PE.

  196. PermitSuppression

    Permit 839194 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  197. PermitSuppression

    Permit 834163 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  198. PermitZoning/use

    Permit 828054 · COMPLETED

    ACCESSORY SIGNAGE FOR PREVIOUSLY APPROVED WAWA FOOD MARKET AS INDICATED ON ATACHED PLANS.

  199. PermitPlumbing

    Permit 835345 · COMPLETED

    SUPPLY AND INSTALL KITCHEN SINK AND WALL OUTLET BOX WITH DRAIN BOX;CONNECT EXISTING SANITARY PIPING,EXISTING SANITARY VENT PIPING AND EXISTING DOMESTIC WATER LINE (RETAIL)

  200. PermitElectrical

    Permit 826524 · COMPLETED

    FURNISH SERVICE CONDUIT AND WIRES FOR LANDLORD WORK TO (3)LOCATIONS GROUND FLOOR FOR FUTURE TENANTS, ONE LOCATION ADD LIGHTING,POWER AND TEMPORARY LIGHTING PER 2008 NEC(COMMERCIAL SPACE)***NO FIRE ALARM***

  201. InvestigationBP_BLDG

    Case 610230 · PASSED

    The cited inspection visit was marked passed.

  202. PermitSuppression

    Permit 828972 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  203. PermitPlumbing

    Permit 829080 · COMPLETED

    INSTALL SANITARY, SANITARY VENT AND DOMESTIC WATER TO NEW PLUMBING FIXTURES. INSTALL 2- WATER CLOSETS, 2- LAVATORIES, 1- MOP SINK AND 1- WATER COOLER (RETAIL/COMMERCIAL)

  204. ViolationPERMP- INST NEW PLUMBING

    Case 610230 · Violation 4494304 · Code A-301.1/54 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  205. ViolationPENALTY- NO PLUMB PERM INFO

    Case 610230 · Violation 4494305 · Code A-901.13/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  206. InvestigationBP_BLDG

    Case 610230 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  207. PermitNew construction

    Permit 802145 · COMPLETED

    FOR PARTIAL FIT-OUT OF A FUTURE RETAIL SPACE WITHIN THE GROUND FLOOR OF A MIXED-USE HIGH-RISE STRUCTURE CURRENTLY UNDER CONSTRUCTION ("EAST PODIUM"; SEE AP#586949, AND ALL AMENDED PERMITS), AS PER PLANS; TO INCLUDE: DEMISING WALLS, PARTITIONS FOR BATHROOMS, JANITOR'S CLOSET, AND AROUND STRUCTURAL ELEMENTS (PREVIOUSLY APPROVED UNDER AP#708216); SEPARATE USE PERMIT & CO REQUIRED PRIOR TO OCCUPANCY; SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK; BUILDING TO BE FULLY SPRINKLERED THROUGHOUT WITH NFPA 13; NO SIGNS ON THIS PERMIT.

  208. PermitNew construction

    Permit 802153 · COMPLETED

    CORE/SHELL PERMIT TO INCLUDE CONSTRUCTION OF NEW DEMISING WALL TO SEPARATE TENANT SPACE UNIT R131 & R130. NO OTHER NEW PARTITIONS ON THIS PERMIT.SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK.

  209. PermitZoning/use

    Permit 813380 · COMPLETED

    WAWA GROCERY STORE TO INCLUDE SALE OF PREPARED GOODS AND SEATING AT GROUND FLOOR AND ACCESSORY SIGNAGE ALL AS INDICATED ON ATTACHED PLANS

  210. PermitElectrical

    Permit 779734 · COMPLETED

    PROVIDE TEMP POWER AND LIGHT,EXTEND THE EXISTING INTO NEW SWS GREAR AND BUSS DUCT. F&I NEW BRANCH CIRCUIT LAOD CENTERS,WIRING,RECEPTALCES AND LIGHTS FOR ALL CORRIDORS,LOBBIES AND STAIRWAYS.PROVIDE POWER AND BRANCH WIRING FOR ALL NEW HVAC EQUIP PERTAINING TO THE APTS PER 2008 NEC (APT BLDG). FURNISH AND INSTALL A COMPLETE FIRE ALARM SYSTEM.

  211. PermitSuppression

    Permit 790661 · COMPLETED

    INSTALLATION OF (2735) NEW SPRINKLERS ALONG WITH THE ASSOCIATED SUPPLY PIPING ON THE THIRD THROUGH PENTHOUSE LEVELS OF THE WEST TOWER IN ACCORDANCE WITH THE NFPA 13 STANDARD AND TWO (2) STANDPIPE RISERS IN ACCORDANCE WITH THE NFPA 14 STANDARD AS PER APPROVED PLANS. SEE A/P 715246 FOR NEW MAIN INSTALLATION INCLUDING FIRE PUMP(S) & BACKFLOW PREVENTION.

  212. PermitAdministrative

    Permit 779183 · COMPLETED

    AMEND PERMIT #727764 FOR THE ERECTION, OPERATION, AND DIS-ASSEMBLY OF TOWER CRANE LOCATED COMPLETELY WITHIN PROPERTY LINES. STREET CLOSURE PERMITS REQUIRED PRIOR TO ERECTION OF CRANE. THE ERECTION, USE AND INSPECTION OF THE TOWER CRANE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND TITLE 9 CHAPTER 9-3300 OF THE PHILADELPHIA CODE.

  213. PermitSuppression

    Permit 769525 · COMPLETED

    FOR THE INSTALLATION OF AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 ON THE MEZZANINE, CONNECTING TO THE PREVIOUSLY APPROVED AUTOMATIC SPRINKLER SYSTEM FROM THE GROUND FLOOR THROUGH THE 17TH FLOOR (SEE AP#728885), AS PER PLANS.

  214. PermitElectrical

    Permit 769229 · COMPLETED

    FAI NEW 225AMP 480/2 TIV PANEL AND 1 ELEVATOR. 20/3 480 VOLT 3 HEAT PUMP 1 SPLIT UNIT AND BATHROOMS

  215. PermitAddition

    Permit 727764 · COMPLETED

    240 UNIT RESIDENTIAL HIGHRISE OVERBUILD (WEST TOWER) ON TOP OF AN EXISTING 2-STORY RETAIL PODIUM. THE LOBBY FOR THE RESIDENCES IS LOCATED ON THE GROUND FLOOR IN THE EXISTING PODIUM AND AN AMENTITY LEVEL IS LOCATED ON THE FIRST FLOOR OF THE TOWER. THE PROJECT CONSISTS OF AN EAST AND WEST RETAIL PODIUM WITH A RESIDENTIAL TOWER (EAST TOWER) ON THE EAST PODIUM, AND THE PROPOSED WEST TOWER ABOVE THE WEST PODIUM. (SEE PERMIT #586949 FOR NEW CONSTRUCTION OF PODIUMS AND EAST TOWER). BELOW THE EXISTING 11TH STREET BUILDING IS A CENTRALIZED LOADING DOCK FOR THE ENTIRE PROJECT ALONG WITH ADDITIONAL UNGERGROUND PARKING.

  216. PermitUse

    Permit 760691 · COMPLETED

    FOR USE AS A SIT DOWN RESATAURANT IN SPACE R-131 ON THE FIRST FLOOR OF AN EXISTING STRUCTURE WITH OTHER PREVIOUSLY APPROVED USES.(NO SIGNS ON THIS PERMIT)

  217. PermitSuppression

    Permit 715246 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13 AND FOR THE INSTALLATION OF STANDPIPES IN EXIT STAIR E2 IN ACCORDANCE WITH NFPA 14, AS PER APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.

  218. PermitSuppression

    Permit 747112 · COMPLETED

    FOR THE INSTALLATION OF AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 ON THE 18TH AND 19TH FLOORS WITHIN THE EAST TOWER OF THE EAST MARKET COMPLEX, USING THE PREVIOUSLY APPROVED (SEE AP#715246) NEW 8" FIRE SERVICE LINE, 8" BACKFLOW PREVENTION DEVICE IN BASEMENT, AND NEW STANDPIPES, AND CONNECTING TO THE PREVIOUSLY APPROVED AUTOMATIC SPRINKLER SYSTEM FROM THE GROUND FLOOR THROUGH THE 17TH FLOOR (SEE AP#728885), AS PER PLANS.

  219. PermitSuppression

    Permit 748091 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  220. PermitElectrical

    Permit 732351 · COMPLETED

    PROVIDE POWER & DATA TO EXTERIOR DISPLAYS - POWER COMING FROM OWNER FURNISHED DISCONNECT SWITCH & IT IS FOR NEW SIGNS, 200AMP FOR EACH SIGN AS PER NEC 2008 CC DISTRICT

  221. PermitAdministrative

    Permit 727195 · COMPLETED

    ADMINISTRATIVE PERMIT TO AMEND AP #586949 TO INCLUDE PLAN REVISIONS FOR THE INSTALLATION OF CURVED DIGITAL SIGNAGE ON THE EAST PODIUM FACADE. REFER TO PREVIOUS APPLICATIONS ON FILE FOR AGENCY APPROVALS (AP#586949). SPECIAL INSPECTIONS REQUIRED FOR ATTACHMENT OF SIGN STRUCTURE. SEE ORIGINAL PERMIT #586949 FOR APPROVED SPECIAL INSPECTORS. LOCATION AND MAX SIZE LIMITATION OF SIGNS AS APPROVED UNDER ZONING PERMIT #570642. SIGNS INCLUDED UNDER THIS BUILDING PERMIT ARE SIGNS DESIGNATED AS D & E ON THE APPROVED ZONING PERMIT PLANS.

  222. PermitPlumbing

    Permit 737492 · COMPLETED

    INSTALLATION OF (1)6", (1)12" & (3)15" LATERALS, HOUSE TRAPS AND PARTIAL HOUSE DRAINS TO WITHIN 5'-0" OF THE BUILDING WALL PER THE APPROVED PLANS - NOTE: PWD (PHILADELPHIA WATER DEPARTMENT) APPROVED A 6" CONNECTION IN LIEU OF AN 8" AS SHOWN ON THE PLANS

  223. PermitZoning/use

    Permit 726413 · COMPLETED

    TENANT FIT OUT OF VACANT SPACE TO BECOME OCCYPIED BUSINESS USE AS A FURNITURE SHOWROOM SPACE- SUITE R-106.

  224. AppealBuilding standards appeal

    Appeal 29116 · CLOSED · APPROVED

    Related permit 718532 · ON 10/13/2016, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #718532.

  225. PermitAlteration

    Permit 713384 · COMPLETED

    FOR FINAL FIT OUT AND CERTIFICATE OF OCCUPANCY FOR RETAIL SPACE AS PART OF A NEW CONSTRUCTION BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  226. PermitSuppression

    Permit 728885 · COMPLETED

    INSTALLATION OF (3753) NEW SPRINKLERS ALONG WITH THE ASSOCIATED SUPPLY PIPING OFF OF PREVIOUSLY APPROVED STANDPIPE INSTALLATION FOR GROUND, FIRST THROUGH THIRD AND FOURTH THROUGH SEVENTEENTH FLOORS AS PER APPROVED PLANS AND NFPA 13 STANDARD. SEE A/P 715246 FOR NEW MAIN INSTALLATION INCLUDING FIRE PUMP, BACKFLOW PREVENTION AND STANDPIPE INSTALLATION.

  227. PermitZoning/use

    Permit 698338 · COMPLETED

    FOR THE ERECTION OF AN ADDITION ("WEST TOWER") TO A PREVIOUSLY APPROVED DETACHED STRUCTURE ON THE SAME LOT AS ANOTHER PREVIOUSLY APPROVED DETACHED STRUCTURE (INTERCONNECTED BELOW GRADE ONLY). STRUCTURE INTERCONNECTED WITH 34 S 11TH STREET BELOW GRADE. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS. WEST STRUCTURE FOR USE AS VACANT RETAIL SPACES (USE REGISTRATION PERMITS REQUIRED PRIOR TO OCCUPANCY) ON THE 1ST AND 2ND FLOORS. MULTI-FAMILY HOUSEHOLD LIVING (TWO-HUNDRED FORTY (240) DWELLINGS) ABOVE WITH ACCESSORY AMENITIES ON THE 3RD LEVEL. EAST STRUCTURE FOR USE AS VACANT RETAIL SPACES ON THE 1ST AND 2ND LEVELS (USE REGISTRATION PERMITS REQUIRED PRIOR TO OCCUPANCY) AND MULTI-FAMILY HOUSEHOLD LIVING (THREE-HUNDRED TWENTY-TWO (322) DWELLINGS) ABOVE WITH ACCESSORY AMENITIES ON THE 3RD LEVEL. FOR A TOTAL OF FIVE-HUNDRED SIXTY-TWO (562) DWELLINGS ON THE LOT. ALL PARKING TO BE LOCATED ENTIRELY BELOW GRADE. PARKING TO INCLUDE A TOTAL OF ONE-HUNDRED SEVENTY-TWO (172) PARKING SPACES; INCLUDING: FORTY-ONE (41) COMPACT SPACES, TEN (10) PREFERENTIAL SPACES, SEVEN (7) ACCESSIBLE SPACES (INCLUDING TWO (2) VAN ACCESSIBLE SPACES). THREE HUNDRED EIGHTEEN (318) BICYCLE PARKING SPACES TO BE PROVIDED ON AN ACCESSIBLE ROUTE. FOUR (4) COMMON LOADING SPACES TO BE PROVIDED ON 34 S 11TH STREET (SEE A/P NO 534844). NO SIGNS ON THIS APPLICATION. ALL NON-ACCESSORY SIGNAGE AS PREVIOUSLY APPROVED ON A/P NO 570462.

  228. PermitAdministrative

    Permit 708216 · COMPLETED

    TO AMEND PERMIT #586949 TO REVISE PLANS TO ACCOMODATE FUTURE ELEVATOR AND TENANT FIT-OUT IMPROVEMENTS. WE ARE RE-SUBMITTING FOR REVISIONS TO EGRESS STAIRS (STAIR E1& STAIR E3) AS WELL AS BASE BUILDING MODIFICATIONS FOR A FUTRE TENANT FIT-OUT (TENANT FIT-OUT TO BE SUBMITTED UNDER SEPARATE PERMIT APPLICATION) REFER TO PREVIOUS APPLICATIONS ON FILE FOR AGENCY APPROVALS.

  229. PermitNew construction

    Permit 708574 · COMPLETED

    CREATION OF SHELL RETAIL SPACE WITHIN GROUND LEVEL AND LEVEL 2 OF A NEW CONSTRUCTION BUILDING AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR FINAL FIT OUT AND CERTIFICATE OF OCCUPANCY. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  230. PermitNew construction

    Permit 672154 · COMPLETED

    INSTALLATION OF ONE(1) UL LISTED, 1,000 GALLON, DOUBLE-WALL ABOVE GROUND FUEL OIL STORAGE TANK (AST) WITH MONITORING SYSTEM (NOT MORE THAN TWO STORIES BELOW GRADE PLANE). SEPARATE PERMITS REQUIRED FOR ANY ASSOCIATED ELECTRICAL WORK AND FOR INSTALLATION OF FIRE SUPPRESSION SYSTEM AT FUEL OIL STORAGE ROOM. ALL WORK TO BE PERFORMED BY A DEP CERTIFIED CONTRACTOR.

  231. AppealBuilding standards appeal

    Appeal 26956 · CLOSED · APPROVED

    Related permit 650455 · ON 01/24/16, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #650455.

  232. PermitAdministrative

    Permit 615685 · COMPLETED

    AMEND PERMIT #586949 FOR REVISIONS OF THE NORTH FOUNDATION ALONG THE SEPTA CONCOURSE TO DIVORCE EXISTING SEPTA STRUCTURE FROM EXISTING FOUNDATIONS TO BE DEMOLISHED ON THE 1100 MARKET PROPERTY

  233. PermitElectrical

    Permit 626305 · COMPLETED

    WIRE 322 DWELLING UNITS, NEW SERVICE AND PANEL FEEDERS, MECHANICAL CONNECTIONS,LIGHTING, RECEPTICALS THROUGH OUT

  234. PermitAdministrative

    Permit 623924 · COMPLETED

    TO AMEND BLDG. PRMT.# 576437, ISSUED FOR FOUNDATION WORK FOR FUTURE HIGH-RISE BLDGS., FOR A CAST-IN-PLACE CONCRETE FOUNDATION SYSTEM FOR INTALLATION & FUTURE DISASSEMBLY OF TOWER CRANE AS PART OF HIGH RISE CONSTRUCTION PROJECT.

  235. PermitPlumbing

    Permit 616129 · COMPLETED

    INSTALL ALL PLUMBING FIXTURES, DRAIN, DOMESTIC WATER IN BUILDING (MIXED USE) THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004 (RETAIL/COMMERCIAL)

  236. InvestigationBC INSP (likely: building-code inspection)

    Case 244397 · CLOSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.

  237. InvestigationCI INSP

    Case 308351 · CLOSED

    City marked the record closed; open the case for the closing reason.

  238. InvestigationCI INSP

    Case 260575 · CLOSED

    City marked the record closed; open the case for the closing reason.

  239. License terminal eventNITIN J DESAI: Vendor - Newsstand business license marked inactive

    License 298739 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  240. PermitNew construction

    Permit 586949 · COMPLETED

    NEW CONSTRUCTION OF A MIXED-USE RETAIL/RESIDENTIAL/PARKING STRUCTURE OCCUPYING THE ENTIRE SOUTH SIDE OF THE 1100 BLOCK OF MARKET ST, BOUNDED BY MARKET ST TO THE NORTH, LUDLOW ST TO THE SOUTH, 11TH ST TO THE EAST, AND 12TH ST TO THE WEST. THE STRUCTURE WILL CONSIST OF AN EAST AND WEST RETAIL PODIUM, EACH 2 STORIES IN HEIGHT. EXTENDING AN ADDITIONAL 15 STOIRES ABOVE THE EAST PODIUM (FLOORS 3 THRU 17) WILL BE A 322-UNIT RESIDENTAIL TOWER THAT INDLUDES ACCESSORY AMMENITY SPACES ON THE 3RD FLOOR. BENEATH THE ENTIRE PROJECT IS A 2-LEVEL UNDERGROUND PARKING GARAGE THAT EXTENDS BENEATH LUDLOW ST AND IS CONNECTED TO THE BELOW GRADE LEVELS OF 34 S 11TH ST WHICH CONTAINS ADDITIOINAL PARKING AND A CENTRALIZED LOADING DOCK FOR THE ENTIRE PROJECT. ENTRANCES TO THE PARKING LEVELS WILL BE OFF OF 12TH ST WITHIN THE FOOTPRINT OF THE WEST PODIUM AND OFF OF 11TH ST WITHIN THE EAST PODIUM. SEPARATE PERMIT REQUIRED FOR CONNECTION BETWEEN 1100 MARKET ST AND 34 S 11TH ST @ BELOW GRADE LEVELS. SEE FOUNDATION PERMIT #576437.

  241. PermitNew construction

    Permit 576437 · COMPLETED

    FOR THE ERECTION OF A CAST-IN-PLACE SHALLOW SPREAD FOOTING FOUNDATION SYSTEM W. CONCRETE STEM WALLS, GRADE BEAMS, AND PIERS FOR SUPPORT OF FUTURE ERECTION OF ONE (1) STRUCTURAL STEEL FRAME W. CONCRETE DECK DETACHED HIGH-RISE MIXED-USE MULTI-FAMILY BUILDING & ONE (1) STRUCTURAL STEEL FRAME W. CONCRETE DECK DETACHED TWO (2) STORY ABOVE GRADE PLANE MERCANTILE BUILDING W. COMMON MULTI-LEVEL ENCLOSED BELOW-GRADE PARKING GARAGE. SEPARATE PERMIT REQUIRED FOR SUPER-STRUCTURE & STRUCTURAL STEEL FRAMING CONSTRUCTION.

  242. License terminal eventV & D JEWELRY INCORPORATED (PLATINUM JEWELERS): Precious Metal Dealer business license marked inactive

    License 607384 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  243. PermitZoning/use

    Permit 587746 · COMPLETED

    FOR THE COMPLETE DEMOLITION OF THE EXISTING STRUCTURE. FOR THE ERECTION OF TWO (2) SEMI-DETACHED STRUCTURES (INTERCONNECTED BELOW GRADE ONLY) WITH VEGETATED ROOFS ABOVE THE 2ND FLOOR LEVEL. STRUCTURE INTERCONNECTED WITH 34 S 11TH STREET BELOW GRADE. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS. WEST STRUCTURE FOR USE AS VACANT RETAIL SPACES (USE REGISTRATION PERMITS REQUIRED PRIOR TO OCCUPANCY). EAST STRUCTURE FOR USE AS VACANT RETAIL SPACES ON THE 1ST AND 2ND LEVELS (USE REGISTRATION PERMITS REQUIRED PRIOR TO OCCUPANCY) AND MULTI-FAMILY HOUSEHOLD LIVING (THREE-HUNDRED TWENTY-TWO (322) DWELLINGS) ABOVE WITH ACCESSORY AMENITIES ON THE 3RD LEVEL. ALL PARKING TO BE LOCATED ENTIRELY BELOW GRADE. PARKING TO INCLUDE A TOTAL OF ONE-HUNDRED SEVENTY-SIX (176) PARKING SPACES; INCLUDING: FORTY-TWO (42) COMPACT SPACES, TEN (10) PREFERENTIAL SPACES, SEVEN (7) ACCESSIBLE SPACES (INCLUDING TWO (2) VAN ACCESSIBLE SPACES). THREE HUNDRED EIGHTEEN (318) BICYCLE PARKING SPACES TO BE PROVIDED ON AN ACCESSIBLE ROUTE. FOUR (4) COMMON LOADING SPACES TO BE PROVIDED ON 34 S 11TH STREET (SEE A/P NO 534844). NO SIGNS ON THIS APPLICATION. ALL NON-ACCESSORY SIGNAGE AS PREVIOUSLY APPROVED ON A/P NO 570462.

  244. PermitZoning/use

    Permit 561650 · COMPLETED

    FOR THE COMPLETE DEMOLITION OF AN EXISTING ATTACHED STRUCTURE. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLAN. FOR USE AS A VACANT LOT.

  245. PermitDemolition

    Permit 561655 · COMPLETED

    FOR THE COMPLETE DEMOLITION OF EXISTING TWO (2) STORY DETACHED STRUCTURE*ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK & PHILADELPHIA STREETS DEPARTMENT APPROVAL REQUIRED FOR STREET CLOSURE & PEDESTRIAN/VEHICULAR PROTECTION* DEMOLITION TO BE IN ACCORDANCE WITH CODE BULLETIN NO. B-1302 DEMOLITION STANDARDS AND ACTIVITY CONTROLS.

  246. PermitZoning/use

    Permit 532839 · COMPLETED

    FOR THE COMPLETE DEMOLITION OF THE EXISTING STRUCTURE. FOR THE ERECTION OF TWO (2) SEMI-DETACHED STRUCTURES (INTERCONNECTED BELOW GRADE ONLY) WITH VEGETATED ROOFS ABOVE THE 2ND FLOOR LEVEL. STRUCTURE INTERCONNECTED WITH 34 S 11TH STREET BELOW GRADE. SIZE AND LOCATION AS SHOWN ON APPLICATION/PLANS. WEST STRUCTURE FOR USE AS VACANT RETAIL SPACES (USE REGISTRATION PERMITS REQUIRED PRIOR TO OCCUPANCY). EAST STRUCTURE FOR USE AS VACANT RETAIL SPACES ON THE 1ST AND 2ND LEVELS (USE REGISTRATION PERMITS REQUIRED PRIOR TO OCCUPANCY) AND MULTI-FAMILY HOUSEHOLD LIVING (THREE-HUNDRED SIXTY-SIX (366) DWELLINGS) ABOVE WITH ACCESSORY AMENITIES ON THE 3RD LEVEL. ALL PARKING TO BE LOCATED ENTIRELY BELOW GRADE. PARKING TO INCLUDE A TOTAL OF ONE-HUNDRED SEVENTY-SIX (176) PARKING SPACES; INCLUDING: FORTY-TWO (42) COMPACT SPACES, TEN (10) PREFERENTIAL SPACES, SEVEN (7) ACCESSIBLE SPACES (INCLUDING TWO (2) VAN ACCESSIBLE SPACES). FOUR-HUNDRED AND SIX (406) BICYCLE PARKING SPACES TO BE PROVIDED ON AN ACCESSIBLE ROUTE. FOUR (4) COMMON LOADING SPACES TO BE PROVIDED ON 34 S 11TH STREET (SEE A/P NO 534844).

  247. PermitZoning/use

    Permit 570462 · COMPLETED

    FOR THE ERECTION OF EIGHT (8) NON-ACCESSORY, DIGITALLY ILLUMINATED SIGNS PER THE PROVISIONS OF §14-906 AND THE APPROVAL OF CPCP. APPLICANT RESPONSIBLE TO FURNISH BOND AS A CONDITION OF BUILDING PERMIT APPROVAL. SIZE AND LOCATION AS SHOWN ON PLANS/APPLICATION. SIGNS FOR USE AS NON-ACCESSORY ADVERTISING.

  248. InvestigationBC INSP (likely: building-code inspection)

    Case 431916 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  249. InvestigationBC INSP (likely: building-code inspection)

    Case 431933 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  250. InvestigationBC INSP (likely: building-code inspection)

    Case 431941 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  251. InvestigationBC INSP (likely: building-code inspection)

    Case 431990 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  252. InvestigationBC INSP (likely: building-code inspection)

    Case 432002 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  253. InvestigationBC INSP (likely: building-code inspection)

    Case 432009 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  254. InvestigationBC INSP (likely: building-code inspection)

    Case 432123 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  255. InvestigationBC INSP (likely: building-code inspection)

    Case 432021 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  256. ViolationANNUAL CERT FIRE ALARM

    Case 432123 · Violation 3184170 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  257. ViolationANNUAL CERT FIRE ALARM

    Case 431916 · Violation 3182726 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  258. ViolationANNUAL CERT FIRE SUPP

    Case 431916 · Violation 3182727 · Code FC-915.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  259. ViolationRENEW LIC INDICATED

    Case 431933 · Violation 3182756 · Code LR-1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  260. ViolationCAL LO (Commercial Activity License required)

    Case 431941 · Violation 3182868 · Code 19-2602.1/1 · COMPLIED

    Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city. City marked this violation complied with; check the resolution date and live case for what was accepted.

  261. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 431941 · Violation 3182870 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.

  262. ViolationANNUAL CERT FIRE ALARM

    Case 431941 · Violation 3182869 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  263. ViolationEXCEEDS PERMIT-SIGN

    Case 431941 · Violation 3182867 · Code 14-1704/41 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  264. ViolationANNUAL CERT FIRE ALARM

    Case 431990 · Violation 3183085 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  265. ViolationCAL LO (Commercial Activity License required)

    Case 431990 · Violation 3183084 · Code 19-2602.1/1 · COMPLIED

    Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city. City marked this violation complied with; check the resolution date and live case for what was accepted.

  266. ViolationANNUAL CERT FIRE ALARM

    Case 432002 · Violation 3183125 · Code FC-915.1/3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  267. ViolationCAL LO (Commercial Activity License required)

    Case 432009 · Violation 3183170 · Code 19-2602.1/1 · COMPLIED

    Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city. City marked this violation complied with; check the resolution date and live case for what was accepted.

  268. ViolationOBTAIN LIC INDICATED (Obtain the license identified in the notice)

    Case 432021 · Violation 3183249 · Code LO-1 · COMPLIED

    The shorthand does not identify the license type; open the case notice for that detail. City marked this violation complied with; check the resolution date and live case for what was accepted.

  269. InvestigationBC INSP (likely: building-code inspection)

    Case 431933 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  270. InvestigationBC INSP (likely: building-code inspection)

    Case 432009 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  271. InvestigationBC INSP (likely: building-code inspection)

    Case 431941 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  272. InvestigationBC INSP (likely: building-code inspection)

    Case 432002 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  273. InvestigationBC INSP (likely: building-code inspection)

    Case 431967 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  274. InvestigationBC INSP (likely: building-code inspection)

    Case 431990 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  275. InvestigationBC INSP (likely: building-code inspection)

    Case 431982 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  276. InvestigationBC INSP (likely: building-code inspection)

    Case 431916 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  277. InvestigationBC INSP (likely: building-code inspection)

    Case 432021 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  278. InvestigationBC INSP (likely: building-code inspection)

    Case 432123 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  279. License terminal eventPINALI INC: Food Establishment, Retail Permanent Location business license marked inactive

    License 313147 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  280. License issue eventV & D JEWELRY INCORPORATED (PLATINUM JEWELERS): Precious Metal Dealer business license initially issued

    License 607384 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  281. License terminal eventRONALD AIKENS (RONN JAIMZ): Handbill Distribution L&I license filing marked inactive

    License 587472 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  282. InvestigationCI INSP

    Case 375828 · PASSED

    The cited inspection visit was marked passed.

  283. PermitSign

    Permit 470131 · COMPLETED

    INSTALLING (3) INTERNALLY ILLUMINATED SIGNS FOR STORE. REFACING 1 INTERNALLY ILLUMINATED WALL SGN

  284. InvestigationCI INSP

    Case 375828 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  285. PermitZoning/use

    Permit 461304 · COMPLETED

    FOR THE INSTALLATION OF 2 ILLUMINATED WALL SIGNS, 4 APPLICATION OF SELF ADHESIVE DOOR VINYL GRAPHICS, 1 REPLACING THE RACE OF CABINET SIGN WITH VINYL GRAPHICS, 1 REPLACING FACE WITH VINYL GRAPHICS, 1 APPLY NEW WINDOW WRAP FOR THE STORE FRONT

  286. ViolationFIRE-ELECT OPEN JUNCTION BOX

    Case 375828 · Violation 2806624 · Code FC-605.6/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  287. ViolationVIOL C&I MESSAGE

    Case 375828 · Violation 2806623 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  288. InvestigationCI INSP

    Case 375046 · PASSED

    The cited inspection visit was marked passed.

  289. InvestigationCI INSP

    Case 375828 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  290. ViolationFIRE-DOOR STOP PROHIBITED

    Case 375046 · Violation 2756964 · Code FC-703.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  291. ViolationVIOL C&I MESSAGE

    Case 375046 · Violation 2756963 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  292. InvestigationCI INSP

    Case 375046 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  293. License issue eventRONALD AIKENS (RONN JAIMZ): Handbill Distribution L&I license filing initially issued

    License 587472 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  294. InvestigationCI INSP

    Case 346086 · PASSED

    The cited inspection visit was marked passed.

  295. ViolationVIOL C&I MESSAGE

    Case 346086 · Violation 2550500 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  296. ViolationFIRE PROT SYS MAINTENANCE

    Case 346086 · Violation 2550501 · Code FC-901.7/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  297. InvestigationCI INSP

    Case 346086 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  298. ViolationANNUAL CERT FIRE SUPP

    Case 308351 · Violation 2386111 · Code FC-915.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  299. ViolationVIOL C&I MESSAGE

    Case 308351 · Violation 2386110 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  300. ViolationVIOL C&I MESSAGE

    Case 308372 · Violation 2342547 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  301. InvestigationCI INSP

    Case 308372 · PASSED

    The cited inspection visit was marked passed.

  302. License terminal eventFLYERS WIVES CHARITIES INC: Special Permit L&I license filing marked inactive

    License 548384 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  303. PermitSuppression

    Permit 368581 · COMPLETED

    RELOCATION AND REPLACEMENT OF THE DRY STANDPIPE FIRE DEPARTMENT CONNECTION, PIPING FROM THE CHECK VALVE.

  304. License issue eventFLYERS WIVES CHARITIES INC: Special Permit L&I license filing initially issued

    License 548384 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  305. License terminal eventPHILADELPHIA VISION OF CENTER CITY INC.: Handbill Distribution L&I license filing marked inactive

    License 491598 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  306. PermitUse

    Permit 326319 · COMPLETED

    SPACE 1136: RETAIL SALES OF JEWELRY TO INCLUDE BUYING AND SELLING PRECIOUS METALS

  307. ViolationVIOL C&I MESSAGE

    Case 260575 · Violation 1962238 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  308. ViolationLIC MUST BE AVAIL FOR INSP

    Case 260575 · Violation 1962239 · Code A-302.8/31 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  309. ViolationINT S-FLOOR REPAIR (Repair the interior floor)

    Case 260575 · Violation 1962236 · Code PM-305.3/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  310. PermitUse

    Permit 299742 · COMPLETED

    USE SPACE FOR THE SALE OF PRODUCE IN TENANT SPACE 12-22 S. 11TH STREET ALONG 11TH STREET FRONTAGE (PREVIOUSLY AMERICAN PANTS CO.)

  311. ViolationSCALE 1 TO 50 LBS LO

    Case 244397 · Violation 1953892 · Code 09-1403.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  312. ViolationDEALER IN PRECIOUS METALS LO

    Case 244397 · Violation 1953893 · Code 09-615.2/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  313. InvestigationBC INSP (likely: building-code inspection)

    Case 112351 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  314. PermitUse

    Permit 286049 · COMPLETED

    ADDING BUYING OF PRECIOUS METALS IN EXISTING CLOTHING STORE

  315. InvestigationBC INSP (likely: building-code inspection)

    Case 117690 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  316. InvestigationBC INSP (likely: building-code inspection)

    Case 117690 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  317. InvestigationBC INSP (likely: building-code inspection)

    Case 112351 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  318. PermitAlteration

    Permit 258544 · COMPLETED

    REPAIRS TO EXISTING PROPERTY TO INCLUDE: SEALING WALLS, INSTALL TILE FLOOR BUILD KNEE WALL, CHANGE CEILING TILE, INSTALL TRAY SLIDE AND COUNTER. COUNTER HEIGHT NOT TO EXCEED 36"

  319. License issue eventPHILADELPHIA VISION OF CENTER CITY INC.: Handbill Distribution L&I license filing initially issued

    License 491598 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  320. InvestigationCI INSP

    Case 123229 · PASSED

    The cited inspection visit was marked passed.

  321. PermitElectrical

    Permit 220125 · COMPLETED

    16-2X4 FIXTURES, 1 EXIT FIXTURE, 15 SINGLE POLE SWITCHES, 6 - 3 WAY SWITCHES, 17 DUPLEX RECEPTS, 2 GFI'S, 1 WALK IN FRIDGE AND 1 ELECTRIC OVEN AS PER 2005 NEC (CC DISTRICT)

  322. PermitElectrical

    Permit 226399 · COMPLETED

    INSTALL 1 SMOKE DETECTOR, 1 HEAT DETECTOR, 15 HORN/STROBES & 1 NAC PANEL.

  323. PermitAdministrative

    Permit 224103 · COMPLETED

    C.O. FOR CHARTER SCHOOL AS PER PLANS.

  324. PermitPlumbing

    Permit 225123 · COMPLETED

    FIXTURE INSTALLATION

  325. License terminal eventBIG BIG LOT INC: Vendor - Newsstand business license marked inactive

    License 296238 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  326. PermitMajor alteration

    Permit 221084 · COMPLETED

    INTERIOR RENOVATION FOR FUTURE CHARTER SCHOOL AS PER PLANS. SEPARATE PERMIT IS REQUIRED FOR CERTIFICATE OF OCCUPANCY

  327. PermitElectrical

    Permit 223301 · COMPLETED

    FURNISH AND INSTALL 30 CAT 5E PLENUM CABLES AVG CABLE PULL 140 FEET, AS PER, AS PER 2005 NEC (CC DIST) (INSPECTED BY RICH DEAN, UNITED INSP, 12/4/2009 - PASSED)

  328. PermitMechanical

    Permit 221697 · COMPLETED

    RELOCATE (37) DIFFUSERS

  329. PermitDemolition

    Permit 220385 · COMPLETED

    INTERIOR NON LOAD-BEARING DEMOLITION (2ND FLOOR CHARTER SCHOOL)

  330. PermitFast form building

    Permit 220334 · COMPLETED

  331. PermitUse

    Permit 220444 · COMPLETED

    USE TO VARIETY STORE

  332. PermitUse

    Permit 216972 · COMPLETED

    FOE USE AS A "CHARTER SCHOOL" WITHIN A PORTION OF THE EXISTING 2ND FLOOR OF STRUCTURE IN THE SAME BUILDING AND EXISTING RETAIL / COMMERCIAL USES AS PREVIOUSLY APPROVED, NO SIGNS ON THIS APPLICATION.

  333. InvestigationADMIN INSP (likely: administrative inspection)

    Case 163297 · PASSED

    Legacy inspection shorthand; the title alone does not state what condition was examined. The cited inspection visit was marked passed.

  334. PermitFast form building

    Permit 181356 · COMPLETED

  335. InvestigationBC INSP (likely: building-code inspection)

    Case 112354 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  336. InvestigationBC INSP (likely: building-code inspection)

    Case 163297 · CLOSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.

  337. InvestigationBC INSP (likely: building-code inspection)

    Case 163297 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  338. ViolationVIOL BC MESSAGE

    Case 163296 · Violation 971064 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  339. ViolationSCALE 1 TO 50 LBS LO

    Case 163297 · Violation 1060650 · Code 09-1403.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  340. ViolationVIOL BC MESSAGE

    Case 163298 · Violation 971111 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  341. ViolationVIOL BC MESSAGE

    Case 169418 · Violation 1021705 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  342. InvestigationBC INSP (likely: building-code inspection)

    Case 163298 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  343. InvestigationBC INSP (likely: building-code inspection)

    Case 169418 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  344. InvestigationBC INSP (likely: building-code inspection)

    Case 163297 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  345. InvestigationBC INSP (likely: building-code inspection)

    Case 163296 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  346. InvestigationBC INSP (likely: building-code inspection)

    Case 121681 · CLOSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.

  347. PermitMajor alteration

    Permit 126691 · COMPLETED

    FOR THE INSTALLATION OF A NEW ENTRANCE DOOR FOR AN EXISTING TENANT SPACE. ALL WORK SHALL BE IN COMPLIANCE WITH THE APPROVED PLANS.

  348. AppealZoning board appeal

    Appeal 3412 · CLOSED · Dismissed

    PERMIT IS FOR THE ERECTION OF TWO (2) FLAT WALL NON-ILLUMINATED TEMPORARY REAL ESTATE FOR RENT SIGNS (22' X 9': 198 SF EACH SIGN) ACCESSORY TO AN EXISTING OFFICE/RETAIL COMPLEX.

  349. ViolationVIOL BC MESSAGE

    Case 131918 · Violation 710398 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  350. ViolationVIOL BC MESSAGE

    Case 131919 · Violation 710399 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  351. InvestigationBC INSP (likely: building-code inspection)

    Case 131919 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  352. InvestigationBC INSP (likely: building-code inspection)

    Case 131918 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  353. ViolationVIOL BC MESSAGE

    Case 131915 · Violation 710395 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  354. ViolationVIOL BC MESSAGE

    Case 131916 · Violation 710396 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  355. ViolationVIOL BC MESSAGE

    Case 131917 · Violation 710397 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  356. InvestigationBC INSP (likely: building-code inspection)

    Case 131915 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  357. InvestigationBC INSP (likely: building-code inspection)

    Case 131917 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  358. InvestigationBC INSP (likely: building-code inspection)

    Case 131916 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  359. ViolationANNUAL CERT FIRE SUPP

    Case 123229 · Violation 646275 · Code FC-914.1/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  360. ViolationFIRE EXTING-INSTALL TYPE K

    Case 123229 · Violation 646279 · Code FC-904.11/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  361. ViolationAFES-COMM KITCH SERVICE & CERT

    Case 123229 · Violation 646278 · Code FC-904.11/4 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  362. ViolationVIOL C&I MESSAGE

    Case 123229 · Violation 646277 · Code A-000.0/10 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  363. ViolationANNUAL CERT FIRE SUPP INCOMPL

    Case 123229 · Violation 646276 · Code FC-914.1/6 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  364. InvestigationCI INSP

    Case 123229 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  365. ViolationVENDOR CC PROHIBITED AREA AH

    Case 121681 · Violation 633594 · Code 09-204.10/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  366. InvestigationBC INSP (likely: building-code inspection)

    Case 121681 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  367. ViolationCAL LO (Commercial Activity License required)

    Case 117690 · Violation 1706033 · Code 19-2602.1/1 · COMPLIED

    Philadelphia Code §19-2602(1) requires a Commercial Activity License before conducting business in the city. City marked this violation complied with; check the resolution date and live case for what was accepted.

  368. InvestigationBC INSP (likely: building-code inspection)

    Case 117690 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  369. InvestigationBC INSP (likely: building-code inspection)

    Case 111247 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  370. InvestigationCI INSP

    Case 57590 · PASSED

    The cited inspection visit was marked passed.

  371. ViolationVIOL BC MESSAGE

    Case 111243 · Violation 560908 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  372. ViolationDEALER IN PRECIOUS METALS LR

    Case 111247 · Violation 560940 · Code 09-615.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  373. ViolationSCALE 1 TO 50 LBS LR

    Case 111247 · Violation 560939 · Code 09-1403.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  374. ViolationVIOL BC MESSAGE

    Case 112335 · Violation 567220 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  375. ViolationVIOL BC MESSAGE

    Case 112338 · Violation 567226 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  376. ViolationVIOL BC MESSAGE

    Case 112340 · Violation 567262 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  377. ViolationSCALE 1 TO 50 LBS LR

    Case 112351 · Violation 1705744 · Code 09-1403.1/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  378. ViolationDEALER IN PRECIOUS METALS LR

    Case 112351 · Violation 1705745 · Code 09-615.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  379. ViolationDEALER IN PRECIOUS METALS LR

    Case 112354 · Violation 567340 · Code 09-615.2/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  380. ViolationSCALE 1 TO 50 LBS LO

    Case 112354 · Violation 567339 · Code 09-1403.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  381. ViolationVIOL BC MESSAGE

    Case 112356 · Violation 567355 · Code A-000.0/11 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  382. InvestigationBC INSP (likely: building-code inspection)

    Case 112335 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  383. InvestigationBC INSP (likely: building-code inspection)

    Case 112356 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  384. InvestigationBC INSP (likely: building-code inspection)

    Case 112354 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  385. InvestigationBC INSP (likely: building-code inspection)

    Case 112351 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  386. InvestigationBC INSP (likely: building-code inspection)

    Case 112340 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  387. InvestigationBC INSP (likely: building-code inspection)

    Case 112338 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  388. InvestigationBC INSP (likely: building-code inspection)

    Case 111243 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  389. InvestigationBC INSP (likely: building-code inspection)

    Case 111247 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  390. PermitElectrical

    Permit 64450 · COMPLETED

    INSTALLATION OF ONE (1) 20 AMP CIRCUIT FOR SECURITY DOOR MOTOR. (CENTER CITY DISTRICT)

  391. InvestigationBC INSP (likely: building-code inspection)

    Case 56164 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  392. InvestigationBC INSP (likely: building-code inspection)

    Case 88475 · PASSED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.

  393. InvestigationCI INSP

    Case 50751 · PASSED

    The cited inspection visit was marked passed.

  394. InvestigationCI INSP

    Case 57590 · CLOSED

    City marked the record closed; open the case for the closing reason.

  395. InvestigationBC INSP (likely: building-code inspection)

    Case 56164 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  396. InvestigationCI INSP

    Case 50082 · PASSED

    The cited inspection visit was marked passed.

  397. InvestigationBC INSP (likely: building-code inspection)

    Case 56164 · FAILED

    Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  398. InvestigationCI INSP

    Case 50291 · PASSED

    The cited inspection visit was marked passed.

  399. InvestigationCI INSP

    Case 50082 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  400. InvestigationCI INSP

    Case 50751 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  401. License issue eventPINALI INC: Food Establishment, Retail Permanent Location business license initially issued

    License 313147 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  402. License issue eventBIG BIG LOT INC: Vendor - Newsstand business license initially issued

    License 296238 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  403. License issue eventNITIN J DESAI: Vendor - Newsstand business license initially issued

    License 298739 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  404. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2024-001950 · Refused

Where this comes from

Methodology & freshness

This report was assembled Jul 26, 2026, 7:34 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)