Apartment building report

116 N 9th St

4 stories6,844 sqftCMX4built 2017

Property at a glanceApartment building

908 Cherry St Develop

2026 assessment
$1.3M OPA value, not a listing price
2027 published assessment
$1.2M Future roll, not the current tax bill
Neighborhood area
Washington Square West · Chinatown Approximate · based on ZIP 19107
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $1,151,400. It is not yet the billed-year tax basis.

$0$1.0M$2.0M$1.2M201320162019202220252027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicenseCertification

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record91 events · exact dates, newest first
  1. PermitSign
  2. CertificationSprinkler Certification
  3. InspectionL&I investigation
  4. PermitSigns (Accessory / Non-Accessory)
  5. L&I violationEXTERIOR AREA SANITATION
  6. InspectionL&I investigation
  7. PermitChange of Use
  8. CertificationFire Alarm Certification
  9. PermitChange of Use
  10. CertificationSprinkler Certification
  11. CertificationFire Alarm Certification
  12. CertificationSprinkler Certification
  13. CertificationSprinkler Certification
  14. CertificationFire Alarm Certification
  15. CertificationSprinkler Certification
  16. LicenseFUNRAY RETAILER LLC (TAN TEA): Food Preparing and Serving business license marked inactive
  17. CertificationFire Alarm Certification
  18. CertificationFire Alarm Certification
  19. LicenseFUNRAY RETAILER LLC (TAN TEA): Food Preparing and Serving business license initially issued
  20. LicenseMofang Inc: Food Preparing and Serving business license marked inactive
  21. CertificationFire Alarm Certification
  22. InspectionCI INSP
  23. InspectionCI INSP
  24. L&I violationGENERAL REQ.- CITE CODE SECTIO
  25. L&I violationFIRE ALARM TESTED/CERTIFIED
  26. L&I violationFIRE SUPPRESSION CERTIFICATION
  27. L&I violationMECH - HEATING RESIDENT TEMP
  28. InspectionCI INSP
  29. InspectionPRECOURT (likely: pre-court compliance inspection)
  30. LicenseMofang Inc: Food Preparing and Serving business license initially issued
  31. InspectionBP_BLDG
  32. PermitSuppression
  33. PermitZoning/use
  34. PermitPlumbing
  35. PermitElectrical
  36. PermitAddition and/or Alteration
  37. PermitAddition and/or Alteration
  38. InspectionBP_BLDG
  39. PermitUse
  40. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  41. InspectionBP_BLDG
  42. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  43. PermitUse
  44. License908 CHERRY STREET DEVELOPMENT LLC: Rental landlord or residential registration initially issued
  45. L&I violationSTANDPIPE SYSTEM CERTIFICATION
  46. L&I violationPLUMBING SYSTEMS-GENERAL
  47. L&I violationMULTI FAMILY (R2)
  48. L&I violationEXIT DOORS SELF CLOSING/LATCHI
  49. L&I violationMECH - MECHANICAL EQUIPMENT
  50. InspectionHCEU INSP (Housing Code Enforcement Unit inspection)
  51. L&I violationBLDG PERMIT REQUIRED
  52. L&I violationLISTED CONDIT DOES NOT COMPLY
  53. InspectionBP_BLDG
  54. InspectionPRECOURT (likely: pre-court compliance inspection)
  55. PermitAdministrative
  56. AppealBuilding standards appeal
  57. InspectionPRECOURT (likely: pre-court compliance inspection)
  58. InspectionPRECOURT (likely: pre-court compliance inspection)
  59. InspectionBP_BLDG
  60. InspectionBP_BLDG
  61. L&I violationWORKMANLIKE- BUILDING CODE
  62. L&I violationDEBRIS REMOVE - CONSTR
  63. L&I violationEXT A-PATHWAYS CLEAR/MAINTAIN
  64. InspectionBP_BLDG
  65. PermitAdministrative
  66. PermitPlumbing
  67. PermitSuppression
  68. InspectionBP_BLDG
  69. InspectionBP_BLDG
  70. L&I violationPERMB- WORK NOT SAME AS PERMIT
  71. L&I violationPERMB- OPENIN CONNECT PROPS
  72. L&I violationPENALTY- NO PLUMB PERM INFO
  73. L&I violationPERMP- INST NEW PLUMBING
  74. InspectionBP_BLDG
  75. InspectionBP_BLDG
  76. PermitMechanical
  77. L&I violationINSURANCE - POST CERT
  78. PermitAdministrative
  79. AppealBuilding standards appeal
  80. PermitPlumbing
  81. PermitElectrical
  82. PermitZoning/use
  83. L&I violationPERM - MUST POST
  84. PermitPlumbing
  85. PermitPlumbing
  86. InspectionBP_BLDG
  87. InspectionBP_BLDG
  88. L&I violationPERM - MUST POST
  89. InspectionBP_BLDG
  90. PermitNew construction
  91. PermitZoning/use

Verify the public record

$1,786/year estimated property tax

2026 taxable assessment $127,610 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $1,151,400. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881519110
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationPartial assessment exemption, basis unverified

2026 OPA taxes $127,610 of $1,276,100 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.

See the assessment math →
Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartment building, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartment building Apts 5-50 Units Masonry
Owner
908 Cherry St Develop
$ / sq ft
$168 above the $147 median for 2,826 apartments parcels citywide
Licensed units
5 active rental license
Interior area
6,844 sqft
Lot size
2,036 sqft
Stories
4
Built
2017
Zoning
CMX4

Recorded owner

Who's behind it

908 Cherry St Develop · corporate / LLC owner

• Tax bills mail to 3805 Cottage Lane, Newtown Square PA, 19073 — outside Philadelphia
• Holds an active rental license for this address

Block context

100 block of N 9th St. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 118-22 N 9th St  ·  112-14 N 9th St

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
FUNRAY RETAILER LLC (TAN TEA)Inactive

Food Preparing and Serving · Initial issue date Jun 17, 2021 · Terminal license date Aug 15, 2023

Mofang IncInactive

Food Preparing and Serving · Initial issue date Dec 4, 2018 · Terminal license date Feb 1, 2021

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

908 CHERRY STREET DEVELOPMENT LLCActive

Rental · Initial issue date Oct 6, 2017 · Filed expiration Oct 5, 2026

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 91 dated rows
  1. PermitSign

    Permit GP-2026-003338 · Completed

    FOR THE INSTALLATION OF AN AWNING WITH COPY OF SIGNS ON FRONT ONLY. SIGN TO BE WITH STATIC ILLUMINATION. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK.

  2. CertificationSprinkler Certification

    Certification BC-2026-013380 · Certified

    Expires 2027-04-27

  3. InvestigationL&I investigation

    Case CF-2026-002624 · PASSED

    The cited inspection visit was marked passed.

  4. PermitSigns (Accessory / Non-Accessory)

    Permit ZP-2026-001713 · Completed

    FOR THE INSTALLATION OF ONE (1) STATICALLY ILLUMINATED WALL SIGN ON AN AWNING. SIZE AND LOCATION AS SHOWN IN APPLICATION/PLANS

  5. ViolationEXTERIOR AREA SANITATION

    Case CF-2026-002624 · Violation VI-2026-001625 · Code PM15-302.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  6. InvestigationL&I investigation

    Case CF-2026-002624 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  7. PermitChange of Use

    Permit ZP-2025-012061 · Issued

    Retail Sales - Consumer Goods; Assembly and Entertainment

  8. CertificationFire Alarm Certification

    Certification BC-2025-023425 · Certified

    Expires 2026-09-08

  9. PermitChange of Use

    Permit ZP-2025-006783 · Issued

    Visitor Accommodations

  10. CertificationSprinkler Certification

    Certification BC-2026-004026 · Certified

    Expires 2026-04-15

  11. CertificationFire Alarm Certification

    Certification BC-2024-028106 · Certified

    Expires 2025-10-15

  12. CertificationSprinkler Certification

    Certification BC-2024-027366 · Certified

    Expires 2025-09-04

  13. CertificationSprinkler Certification

    Certification BC-2024-016389 · Certified

    Expires 2025-05-28

  14. CertificationFire Alarm Certification

    Certification BC-2023-021261 · Certified

    Expires 2024-10-17

  15. CertificationSprinkler Certification

    Certification BC-2023-023051 · Certified

    Expires 2024-09-18

  16. License terminal eventFUNRAY RETAILER LLC (TAN TEA): Food Preparing and Serving business license marked inactive

    License 871152 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  17. CertificationFire Alarm Certification

    Certification BC-2022-016284 · Certified

    Expires 2023-11-04

  18. CertificationFire Alarm Certification

    Certification BC-2021-006521 · Certified

    Expires 2022-11-08

  19. License issue eventFUNRAY RETAILER LLC (TAN TEA): Food Preparing and Serving business license initially issued

    License 871152 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  20. License terminal eventMofang Inc: Food Preparing and Serving business license marked inactive

    License 796141 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  21. CertificationFire Alarm Certification

    Certification BC-2020-000956 · Certified

    Expires 2021-10-16

  22. InvestigationCI INSP

    Case 673276 · PASSED

    The cited inspection visit was marked passed.

  23. InvestigationCI INSP

    Case 673276 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  24. ViolationGENERAL REQ.- CITE CODE SECTIO

    Case 673276 · Violation 4986034 · Code FC-13-906 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  25. ViolationFIRE ALARM TESTED/CERTIFIED

    Case 673276 · Violation 4986035 · Code FC-13-915.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  26. ViolationFIRE SUPPRESSION CERTIFICATION

    Case 673276 · Violation 4986036 · Code FC-13-915.1A · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  27. ViolationMECH - HEATING RESIDENT TEMP

    Case 673276 · Violation 4986037 · Code PM15-602.3 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. InvestigationCI INSP

    Case 673276 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  29. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 605047 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  30. License issue eventMofang Inc: Food Preparing and Serving business license initially issued

    License 796141 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  31. InvestigationBP_BLDG

    Case 605047 · CLOSED

    City marked the record closed; open the case for the closing reason.

  32. PermitSuppression

    Permit 923351 · COMPLETED

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)-RELOCATION OF THREE SPRINKLER HEADS. FOR THE RELOCATION OF SPRINKLER HEADS AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.

  33. PermitZoning/use

    Permit 917706 · COMPLETED

    FOR THE ERECTION OF ONE AWNING SIGN ACCESSORY TO AN EXISTING RESTAURANT

  34. PermitPlumbing

    Permit 902863 · COMPLETED

    INSTALL 1 3 COMP SINK 1 FOOD PREP SINK 1 HAND SINK 1 MOP SINK 1 FLOOR DRAIN 1 GARBAGE DISPOSAL 1 INDIRECT DRAIN

  35. PermitElectrical

    Permit 903456 · COMPLETED

    INSTALL LIGHTS, SWITCHES, RECEPTACLES, EMERGENCY LIGHTS, 2-240VOLT RECEPTACLES ONTO EXISTING 100AMP PANEL AS PER 2008 NEC (CC DISTRICT) NO FIRE ALARM ON THIS PERMIT

  36. PermitAddition and/or Alteration

    Permit 858701 · Issued

    LEVEL II ALTERATIONS (NO CHANGE OF OCCUPANCY CLASSIFICATION) FOR THE RELOCATION OF THE FIFTH DWELLING UNIT TO THE FIRST FLOOR REAR AND MEZZANINE LEVEL AS PER APPROVED PLANS. BUILDING TO BE FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  37. PermitAddition and/or Alteration

    Permit 874611 · Issued

    FOR LEVEL 2 INTERIOR ALTERATION TO FIRST FLOOR COMMERCIAL SPACE FOR NEW TENANT FIT-OUT AS PER PLAN.

  38. InvestigationBP_BLDG

    Case 605047 · PASSED

    The cited inspection visit was marked passed.

  39. PermitUse

    Permit 865430 · COMPLETED

    COFFEE SHOP (SIT DOWN RESTAURANT) FROM BASEMENT LEVEL THROUGH FIRST FLOOR. FLOORS TWO, THREE, AND FOUR REMAIN AS PREVIOUSLY APPROVED. NO CHANGE IN HEIGHT OR SQUARE FOOTAGE. NO SIGN WITH THIS PERMIT.

  40. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 606402 · PASSED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.

  41. InvestigationBP_BLDG

    Case 605047 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  42. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 606402 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  43. PermitUse

    Permit 822959 · COMPLETED

    USE TO OFFICE SPACE IN THE BASEMENT LEVEL OF A COMMERCIAL PROPERTY. NO SIGN PERMIT ON THIS APPLICATION.

  44. License issue event908 CHERRY STREET DEVELOPMENT LLC: Rental landlord or residential registration initially issued

    License 753695 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  45. ViolationSTANDPIPE SYSTEM CERTIFICATION

    Case 606402 · Violation 4499655 · Code FC-13-915.1B · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  46. ViolationPLUMBING SYSTEMS-GENERAL

    Case 606402 · Violation 4499656 · Code PM15-504.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  47. ViolationMULTI FAMILY (R2)

    Case 606402 · Violation 4499653 · Code 9-3902 (2) · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  48. ViolationEXIT DOORS SELF CLOSING/LATCHI

    Case 606402 · Violation 4499654 · Code FC-13-100825 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  49. ViolationMECH - MECHANICAL EQUIPMENT

    Case 606402 · Violation 4499657 · Code PM15-603.1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  50. InvestigationHCEU INSP (Housing Code Enforcement Unit inspection)

    Case 606402 · FAILED

    A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  51. ViolationBLDG PERMIT REQUIRED

    Case 605047 · Violation 4458222 · Code A-501.1/1 · RESOLVE

  52. ViolationLISTED CONDIT DOES NOT COMPLY

    Case 605047 · Violation 4458223 · Code A-501.1/5 · RESOLVE

  53. InvestigationBP_BLDG

    Case 605047 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  54. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 523494 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  55. PermitAdministrative

    Permit 720103 · COMPLETED

    TO AMEND THE PERMIT # 495558 TO LEGALIZE THE EXTERIOR OPENINGS AT THE REAR OF THE STRUCTURE AS PER REVISED PLANS. AS PER BOARD OF BUILDING STANDARDS VARIANCE/PROVISO, WINDOWS SHALL BE SET BACK 18" FROM PROPERTY LINE TO CREATE 3'-0" SEPARATION AND SPRINKLER HEAD ABOVE CENTERLINE OF WINDOW SHALL BE REQUIRED.

  56. AppealBuilding standards appeal

    Appeal 29163 · CLOSED · APPROVED

    Related permit 720103 · ON 10/05/2016, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #720103.

  57. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 523494 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  58. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 523494 · FAILED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  59. InvestigationBP_BLDG

    Case 542580 · PASSED

    The cited inspection visit was marked passed.

  60. InvestigationBP_BLDG

    Case 523494 · CLOSED

    City marked the record closed; open the case for the closing reason.

  61. ViolationWORKMANLIKE- BUILDING CODE

    Case 542580 · Violation 3997415 · Code A-104.1/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  62. ViolationDEBRIS REMOVE - CONSTR

    Case 542580 · Violation 3997416 · Code A-104.1/5 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  63. ViolationEXT A-PATHWAYS CLEAR/MAINTAIN

    Case 542580 · Violation 3997417 · Code PM-302.5/1 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  64. InvestigationBP_BLDG

    Case 542580 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  65. PermitAdministrative

    Permit 703057 · COMPLETED

    FOR THE AMENDMENT OF AP#656116 TO DOCUMENT CORRECT FIRE SERVICE LINE OF 2 INCHES. ORIGINAL PERMIT APPROVED FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13/13R AND NFPA 14 SERVICED BY A FIRE SERVICE WITH A BACKFLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM AND STANDPIPES TO BE INSTALLED IN ACCORDANCE WITH NFPA 13/13R AND NFPA 14 STANDARDS.

  66. PermitPlumbing

    Permit 699256 · COMPLETED

    INSTALL CURB TRAP AND 6 LATERAL PA20161600520(MIXED USE)SELF CERTIFICATION'S ARE NO LONGER PERMITTED","ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  67. PermitSuppression

    Permit 656116 · COMPLETED

    FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH NFPA 13/13R AND NFPA 14 SERVICED BY A FOUR INCH FIRE SERVICE WITH A BACKFLOW PREVENTER ASSEMBLY. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. FIRE SUPPRESSION SYSTEM AND STANDPIPES TO BE INSTALLED IN ACCORDANCE WITH NFPA 13/13R AND NFPA 14 STANDARDS.

  68. InvestigationBP_BLDG

    Case 523494 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  69. InvestigationBP_BLDG

    Case 523831 · PASSED

    The cited inspection visit was marked passed.

  70. ViolationPERMB- WORK NOT SAME AS PERMIT

    Case 523494 · Violation 4129144 · Code A-302.10/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  71. ViolationPERMB- OPENIN CONNECT PROPS

    Case 523494 · Violation 4129143 · Code A-301.1/23 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  72. ViolationPENALTY- NO PLUMB PERM INFO

    Case 523831 · Violation 3868850 · Code A-901.13/3 · ERROR

  73. ViolationPERMP- INST NEW PLUMBING

    Case 523831 · Violation 3868849 · Code A-301.1/54 · ERROR

  74. InvestigationBP_BLDG

    Case 523831 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  75. InvestigationBP_BLDG

    Case 523494 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  76. PermitMechanical

    Permit 652274 · COMPLETED

    INSTALL TWO 3 TON ROOF TOP HEAT PUMP, AND TWO SPLIT SYSTEM WITH 2 TON HEAT PUMP

  77. ViolationINSURANCE - POST CERT

    Case 495558 · Violation 3740386 · Code A-302.8/32 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  78. PermitAdministrative

    Permit 610462 · COMPLETED

    TO AMEND PERMIT #495558 TO REVISE THE INTERIOR LAYOUTS AS PER REVISED PLANS. BUILDING SHALL BE SPRINKLERED THROUGHOUT IN ACCORDANCE WITH NFPA 13 STANDARDS. PERMIT ISSUED VIA VARIANCE FROM BOARD OF BUILDING STANDARDS WITH PROVISOS (CASE NO. 25685).

  79. AppealBuilding standards appeal

    Appeal 25685 · CLOSED · APPROVED

    Related permit 610462 · ON 6/22/2015, THE DEPARTMENT OF LICENSES AND INSPECTIONS ISSUED A NOTICE OF REFUSAL FOR APPLICATION #610462.

  80. PermitPlumbing

    Permit 633380 · COMPLETED

    CURB TRAP,FAI,LATERAL AND SECITON OF SOIL LINE TO FOUNDATION WALL AND INSTALL 1.5 WATER SERVIE PA2015231515 (MIXED USE)SELF CERTIFICATION'S ARE NO LONGER PERMITTED","ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FT IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

  81. PermitElectrical

    Permit 615355 · COMPLETED

    INSTALL FIRE ALARM:STROBES,SMOKES AND PULLS PER NFPA 72.INSTALL 600AMP SERVICE WITH COMPLETE FIT OUT OF 5 APTS SWS,LIGHTS AND OUTELTS AND 1 VANILLA BOX FOR COMMERICAL PER 2008 NEC (MIXED USE)

  82. PermitZoning/use

    Permit 596164 · CLOSED

    CONSTRUCTION OF A 4 STORY BUIDING WITH A MEZZANINE IN THE 1ST FLOOR LEVEL NOT TO EXCEED 49 '-0"H. CELLAR & 1ST FL-COMMERCIAL SPACE, 2ND-4TH FLRS 4 APTS TOTAL

  83. ViolationPERM - MUST POST

    Case 532298 · Violation 3456741 · Code A-302.8/30 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  84. PermitPlumbing

    Permit 573570 · EXPIRED

    1 1/2 DOMESTIC W/METER, 1-6" SEWER LINE MAIN TO BLDG (MIXED USE) PA20143160200 (MIXED USE) "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS & PLUMBING TRENCHES IN EXCESS OF 5' IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION

  85. PermitPlumbing

    Permit 532298 · COMPLETED

    ROUGH IN AND INSTALL DETAIL PIPING FOR ALL PIPES AND FIXTURES *FIXTURES FURNISH BY OWNER* (MIXED USE)

  86. InvestigationBP_BLDG

    Case 415470 · PASSED

    The cited inspection visit was marked passed.

  87. InvestigationBP_BLDG

    Case 415470 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  88. ViolationPERM - MUST POST

    Case 415470 · Violation 3084498 · Code A-302.8/30 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  89. InvestigationBP_BLDG

    Case 415470 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  90. PermitNew construction

    Permit 495558 · COMPLETED

    FOR THE ERECTION OF A FOUR-STORY MIXED-USE STRUCTURE TO BE USED FOR AN ACCESSIBLE COMMERCIAL SPACE AND ONE (1) TYPE 'B' UNIT ON THE FIRST FLOOR AND FOUR (4) DWELLING UNITS ABOVE. BUILDING TO BE FULLY SPRINKLERED. SEPARATE PERMITS REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL AND FIRE SUPPRESSION SYSTEMS.

  91. PermitZoning/use

    Permit 479509 · COMPLETED

    AT 910 CHERRY ST ERECT A 4 STORY ADDITION TO AN EXISTING 5 STORY STRUCTURE WITH 56 RESIDENTIAL TOTAL ( 28 EXISTING UNITS + 28 PROPOSED UNITS & 1 EXISTING FOOD PROCESSING OF CHICKEN, MEAT, WHOLESALE AND DISTRIBUTION, AS PER PLANS. AT 908 (PARCEL "A") CHERRY PARCEL "A" TO ERECT A 5 STORY STRUCTURE WITH 1 VACANT COMMERCIAL UNIT AND 9 APT UNITS WITH BALCONIES. PARCEL "B" TO BE THE SAME AS PARCEL "A".

Where this comes from

Methodology & freshness

This report was assembled Jul 29, 2026, 12:51 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)