Apartment building report

3300 Henry Ave

6 stories208,399 sqftCMX3built 1929

Property at a glanceApartment building

Unit One Falls Center LP

2026 assessment
$23M OPA value, not a listing price
2027 published assessment
$25M Future roll, not the current tax bill
Neighborhood area
East Falls Approximate · based on ZIP 19129
From above · selected parcel outlined; choose a neighboring polygon to open it — imagery © Esri, Maxar

Assessment and City record timeline

The line tracks this property’s published City assessment. Markers show deeds, permits, inspections, licenses, violations, certifications, and appeals on their recorded dates. Select one to read the filing.

Assessments are tax-roll values, not sale prices or appraisals. OPA has published a 2027 assessment of $24,729,400. It is not yet the billed-year tax basis.

$0$13M$25M$25M2010201320162019202220252027
Property assessmentAssessmentL&I violationAppealPermitInspectionLicense

Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.

Highlight
Every dated record86 events · exact dates, newest first
  1. PermitAddition and/or Alterations
  2. PermitAddition and/or Alteration
  3. PermitAddition and/or Alteration
  4. PermitAddition and/or Alterations
  5. PermitAlterations
  6. PermitAlterations
  7. PermitAddition and/or Alterations
  8. PermitAddition and/or Alteration
  9. PermitAddition and/or Alteration
  10. PermitAddition and/or Alterations
  11. PermitRough-In
  12. PermitAddition and/or Alterations
  13. PermitAddition and/or Alteration
  14. LicenseFalls Center Condominium Association: Public Garage / Parking Lot business license marked inactive
  15. PermitAddition and/or Alterations
  16. PermitChange of Use
  17. PermitAddition and/or Alteration
  18. PermitAddition and/or Alterations
  19. PermitAddition and/or Alteration
  20. PermitAddition and/or Alteration
  21. PermitAddition and/or Alteration
  22. PermitAddition and/or Alteration
  23. PermitAddition and/or Alterations
  24. PermitAlterations
  25. PermitInterior Non-Load-Bearing Wall Demo.
  26. InspectionL&I investigation
  27. L&I violationDISPOSAL OF OILY WASTE
  28. L&I violationFIRE EXTINGUISHERS TAGGED
  29. L&I violationELEVATORS PICTORIAL SIGN
  30. L&I violationTWO OR MORE ELEVATORS
  31. L&I violationPULL STATION SIGNS
  32. InspectionL&I investigation
  33. LicenseFalls Center Condominium Association: Public Garage / Parking Lot business license initially issued
  34. PermitAddition and/or Alteration
  35. PermitAddition and/or Alterations
  36. PermitAlterations
  37. PermitAddition and/or Alteration
  38. PermitElectrical
  39. PermitSuppression
  40. PermitPlumbing
  41. PermitMajor alteration
  42. PermitMechanical
  43. PermitElectrical
  44. PermitElectrical
  45. LicenseUnit One Falls Center, LP: Rental landlord or residential registration initially issued
  46. InspectionEP_ELEC
  47. PermitUse
  48. AppealZoning board appeal
  49. PermitElectrical
  50. PermitElectrical
  51. PermitMechanical
  52. PermitPlumbing
  53. PermitSuppression
  54. PermitUse
  55. PermitMajor alteration
  56. PermitPlumbing
  57. PermitElectrical
  58. PermitElectrical
  59. PermitPlumbing
  60. PermitElectrical
  61. InspectionEP_ELEC
  62. L&I violationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)
  63. L&I violationPENALTY- NO ELEC PERM INFO
  64. InspectionEP_ELEC
  65. PermitMechanical
  66. PermitElectrical
  67. PermitPlumbing
  68. PermitMajor alteration
  69. PermitUse
  70. AppealZoning board appeal
  71. PermitSuppression
  72. PermitElectrical
  73. PermitElectrical
  74. InspectionPRECOURT (likely: pre-court compliance inspection)
  75. PermitElectrical
  76. InspectionCI INSP
  77. PermitMechanical
  78. InspectionCI INSP
  79. InspectionCI INSP
  80. InspectionCI INSP
  81. L&I violationSHELTER PLN-REQ¿D
  82. L&I violationGENERATOR SET TEST REQ
  83. L&I violationSHELTER DRILL CONDUCT
  84. L&I violationFIRE-CURTAINS/DRAPES
  85. L&I violationVIOL C&I MESSAGE
  86. InspectionCI INSP

Verify the public record

$324,754/year estimated property tax

2026 taxable assessment $23,200,000 × 1.3998%. This is an estimate, not a bill or account balance. The City maintains payments, credits, interest, and the current amount due.

OPA has published a 2027 assessment of $24,729,400. It is not the 2026 billed-year value.

Current City balanceCheck Tax Center

Payments, credits, interest, and the current amount due are maintained by the City.

OPA 881136900
Open Philadelphia Tax Center →Use “View period balance” to inspect each tax year.
Exemption classificationNo exemption shown

2026 taxable assessment equals the full assessed value.

Historical delinquency sources No current conclusion

This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.

For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”

Building report

Apartment building

Apartment building, recorded in the City's apartments category. The public record and owner trail follow.

What it is
Apartment building Apts 100+ Units Masonry
Owner
Unit One Falls Center LP
$ / sq ft
$119 below the $147 median for 2,826 apartments parcels citywide
Licensed units
131 active rental license
Interior area
208,399 sqft
Lot size
70,676 sqft
Stories
6
Built
1929
Zoning
CMX3

Recorded owner

Who's behind it

Unit One Falls Center LP · corporate / LLC owner

• Tax bills mail to 2929 Walnut St, Philadelphia PA, 19104
• Holds an active rental license for this address

Block context

3300 block of Henry Ave. Compare parcels, ownership, and public-record history.

See the whole block →

Next door: 3300 Henry Ave  ·  3300 Henry Ave

Business licenses at this address Latest pull

What L&I has registered at this OPA parcel, newest initial license date first.

Open the City record ↗
Falls Center Condominium AssociationInactive

Public Garage / Parking Lot · Initial issue date May 30, 2021 · Terminal license date Jul 28, 2024

Landlord and residential filings

These are property registrations or landlord filings, not businesses operating at this address.

Unit One Falls Center, LPActive

Rental · Initial issue date Jun 6, 2018 · Filed expiration Jun 5, 2027

A license is an L&I registration, not proof that a business is open, operating today, or located at this storefront. Dates are license dates. Events are deduped by parcel, business identity, and license type, so a renewal is not shown as another opening. Other permit and filing types remain in the full source ledger.

Open every source row 86 dated rows
  1. PermitAddition and/or Alterations

    Permit FP-2026-001029 · Issued

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 33 existing sprinkler heads to accommodate new walls and ceiling layouts

  2. PermitAddition and/or Alteration

    Permit EP-2026-000880 · Completed

    New tenant fit-out (Middleberg Orthodontics) Install new receptacles, switches, and LED light fixtures (2) 200 amp panels -TAMPER RESISTANT RECEPTACLES - All work will be installed per the 2017 NEC **NO FIRE ALARM ON THIS PERMIT**

  3. PermitAddition and/or Alteration

    Permit EP-2025-010682 · Completed

    Electrical Permit for combo CP-2025-004388 Install all lighting and receptacles. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC. AMENDMENT: Change Suite #100 to correct Suite #134

  4. PermitAddition and/or Alterations

    Permit MP-2025-005701 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2025-004388 [AMENDMENT 3/31/2026 FOR A CHANGE IN WORK LOCATION ADDRESS FROM SUITE #100 TO SUITE #134. NO OTHER CHANGES THIS AMENDMENT.]

  5. PermitAlterations

    Permit PP-2025-014417 · Completed

    AMENDMENT 3/30/2026 CHANGE IN WORK LOCATION FROM SUITE 100 TO SUITE 134 Plumbing Permit (Interior) for combo CP-2025-004388

  6. PermitAlterations

    Permit PP-2025-015575 · Amendment Application Incomplete

    Supply and Install a 4" domestic backflow preventer with strainer. Supply and install a 2" domestic backflow preventer with isolation valve. *WITHOUT PIPING*

  7. PermitAddition and/or Alterations

    Permit FP-2025-002361 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating 11 sprinkler heads.

  8. PermitAddition and/or Alteration

    Permit CP-2025-004388 · Issued

    FOR LEVEL II INTERIOR ALTERATIONS WITH A CHANGE IN USE WITHOUT A CHANGE IN OCCUPANCY CLASSIFICATION TO GROUP B SOLE MEDICAL/HEALTH PRACTITIONER OFFICE (PHYSICAL THERAPY OFFICE) IN SUITE #100. EXISTING BUILDING IS SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IEBC. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SUPPRESSION WORK. [AMENDMENT 3/12/2026 FOR A CHANGE IN WORK LOCATION ADDRESS FROM SUITE #100 TO SUITE #134. NO OTHER CHANGES THIS AMENDMENT.]

  9. PermitAddition and/or Alteration

    Permit EP-2024-012250 · Completed

    Installation of new branch circuits in MC Cable, Boxes, Devices, Light Fixtures and Controls Installation of SPEAKER/STROBES, STROBES Fire Alarm system notification appliances. ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72.

  10. PermitAddition and/or Alterations

    Permit MP-2024-005681 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.

  11. PermitRough-In

    Permit EP-2024-012251 · Completed

    Rough-In Permit for EP-2024-012250 Installation of new branch circuits in MC Cable, Boxes, Devices, Light Fixtures and Controls Installation of additional FA devices on Fire Alarm system

  12. PermitAddition and/or Alterations

    Permit FP-2024-002585 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Modify existing sprinkler heads to accommodate new layout of walls and ceilings on third floor work area.

  13. PermitAddition and/or Alteration

    Permit CP-2024-006094 · Completed

    LEVEL II INTERIOR ALTERATIONS WITH PARTIAL CHANGE OF OCCUPANCY TO EXPAND AN EXISTING EDUCATIONAL FACILITY ON THE THIRD FOOR OF AN EXISTING BUILDING AS PER APPROVED PLANS. EXISTING BUILDING FULLY SPRINKLERED. *2018 IEBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**

  14. License terminal eventFalls Center Condominium Association: Public Garage / Parking Lot business license marked inactive

    License 869662 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  15. PermitAddition and/or Alterations

    Permit MP-2023-003311 · Completed

    FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTWORK. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

  16. PermitChange of Use

    Permit ZP-2023-008584 · Issued

    Public, Civic, and Institutional - Educational Facilities

  17. PermitAddition and/or Alteration

    Permit EP-2023-005778 · Completed

    Install electrical devices related to the use of the partition walls and new drop ceilings in the space. New electrical circuits are being tied into an existing panelboard. Install new code compliant lighting throughout space.Install fire alarm along with new devices that are being tied into the existing building system. . ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC,2016 NFPA-72,2018 PHILA FIRE CODE.

  18. PermitAddition and/or Alterations

    Permit FP-2023-000381 · Completed

    EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocating 35 sprinkler heads for renovation

  19. PermitAddition and/or Alteration

    Permit CP-2022-005100 · Completed

    FOR A LEVEL II INTERIOR ALTERATIONS TO AN EXISTING STRUCTURE. FOR USE AS A BUSINESS OCCUPANCY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, EXTERIOR AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.**NO SIGN APPROVED ON THIS PERMIT** **AMENDED AS OF 1/4/2024 FOR A LAYOUT MODIFICATION AS PER APPROVED PLANS**

  20. PermitAddition and/or Alteration

    Permit CP-2022-006322 · Completed

    MAKE SAFE PERMIT TO COMPLY WITH CF-2022-100770, PER ENGINEERS REPORT AND PLANS, FOR BRICK FACADE REPAIR REPAIRS/REPLACEMENT OF EXTERIOR WALLS PER APPROVED PLANS AND IN ACCORDANCE WITH CODE BULLETIN PM-1801. LICENSED PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION. SEPARATE PERMITS REQUIRED FOR ADDITIONAL ALTERATIONS NOT ADDRESSED IN APPROVED PLANS. MAKE SAFE TO COMPLY CF-2022-100770, PER ENGINEERS REPORT AND PLANS, FOR BRICK FACADE REPAIR

  21. PermitAddition and/or Alteration

    Permit CP-2022-004072 · Completed

    FOR LEVEL 2 ALTERATIONS OF GROUND FLOOR TENANT SPACE OF AN EXISTING STRUCTURE AS PER PLANS.

  22. PermitAddition and/or Alteration

    Permit EP-2022-008451 · Completed

    Electrical Permit for combo CP-2022-004072

  23. PermitAddition and/or Alterations

    Permit MP-2022-004451 · Completed

    Mechanical / Fuel Gas Permit for combo CP-2022-004072

  24. PermitAlterations

    Permit PP-2022-012394 · Completed

    Plumbing Permit (Interior) for combo CP-2022-004072

  25. PermitInterior Non-Load-Bearing Wall Demo.

    Permit GM-2022-006748 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  26. InvestigationL&I investigation

    Case CF-2022-008669 · PASSED

    The cited inspection visit was marked passed.

  27. ViolationDISPOSAL OF OILY WASTE

    Case CF-2022-008669 · Violation VI-2022-006913 · Code FC-13-2211.2.3.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  28. ViolationFIRE EXTINGUISHERS TAGGED

    Case CF-2022-008669 · Violation VI-2022-006907 · Code FC-13-906.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  29. ViolationELEVATORS PICTORIAL SIGN

    Case CF-2022-008669 · Violation VI-2022-006903 · Code FC-13-607.2 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  30. ViolationTWO OR MORE ELEVATORS

    Case CF-2022-008669 · Violation VI-2022-006892 · Code FC-13-604.2.18.3 · CLOSED

    Resolution: CLOSED - WRITTEN IN ERROR City marked the record closed; open the case for the closing reason.

  31. ViolationPULL STATION SIGNS

    Case CF-2022-008669 · Violation VI-2022-006906 · Code FC-13-907.5.1 · COMPLIED

    Resolution: COMPLIED - OWNER REPAIR City marked this violation complied with; check the resolution date and live case for what was accepted.

  32. InvestigationL&I investigation

    Case CF-2022-008669 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  33. License issue eventFalls Center Condominium Association: Public Garage / Parking Lot business license initially issued

    License 869662 · Inactive

    License event. Registration does not prove present operation or storefront occupancy.

  34. PermitAddition and/or Alteration

    Permit EP-2021-002268 · Completed

    Minor fire alarm adjustments Minor lighting additions and receptacles misc pathways for low voltage systems As per APPROVED DRAWINGS -2017 nec and 2016 nfpa 72.

  35. PermitAddition and/or Alterations

    Permit MP-2021-001385 · Completed

    For the installation of a new HVAC system including installation of (2) Zone Dampers, (2) Fire Dampers, (18) GRD's. New round ductwork connecting to new GRD's as per plans.

  36. PermitAlterations

    Permit PP-2021-004299 · Completed

    For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.

  37. PermitAddition and/or Alteration

    Permit CP-2021-000804 · Completed

    No structural work on this permit. Interior alterations as per approved plans. *Asbestos Abatement required prior to commencement of work* All work shall be in accordance with DOH approval.

  38. PermitElectrical

    Permit 946976 · COMPLETED

    INSTALLATION OF (1)225 AMP, 42-CIRCUIT PANEL BOARD, (23) BRANCH CIRCUITS FOR RECEPTACLES THROUGH-OUT SPACE AND INSTALLATION OF (72) LIGHTING FIXTURES AS PER PLANS. AS PER NEC 2008

  39. PermitSuppression

    Permit 949294 · COMPLETED

    RELOCATE 45 EXISTING SPRINKLER HEADS (COMMERCIAL)

  40. PermitPlumbing

    Permit 940908 · COMPLETED

    DEMO EXISTING SPACE. RELOCATE 2 WC, 2 LAV, 1 URN. ADD 8 EXAM SINKS, 1 MS. ADD 4 OUTLET BOX. ALL FROM EXISTING. THE INSTALLATION WILL COMPLY WITH THE PHILA PLUMBING CODE 2004.(NORTH DIST)

  41. PermitMajor alteration

    Permit 922078 · COMPLETED

    NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. *ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK* SEPARATE PERMIT REQUIRED FOR ANY MEP AND FIRE SUPPRESSION WORK.

  42. PermitMechanical

    Permit 924261 · COMPLETED

    FOR THE INSTALLATION OF MECHANICAL WORK TO INCLUDE REGISTERS/DIFFUSERS, SUPPLY/EXHAUST DUCTWORK, AND ALL OTHER WORK AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL AND PLUMBING WORK.

  43. PermitElectrical

    Permit 909966 · COMPLETED

    INSTALL TRANSFORMER WITH 60AMP DISCONNECT (COMMERCIAL)

  44. PermitElectrical

    Permit 894349 · COMPLETED

    INSTALLED 3-DEDICATED 12 2 MC LINES FOR ELECTRIC 120V HAND DRYERS AS PER 2008 NEC (NORTH DISTRICT)

  45. License issue eventUnit One Falls Center, LP: Rental landlord or residential registration initially issued

    License 779248 · Active

    License event. Registration does not prove present operation or storefront occupancy.

  46. InvestigationEP_ELEC

    Case 339799 · PASSED

    The cited inspection visit was marked passed.

  47. PermitUse

    Permit 636580 · COMPLETED

    FOR USE AS DRUG AND ALCOHOL COUNSELING (BUSINESS AND PROFESSIONAL OFFICE) IN UNIT 1 SUITE 1.C.8 WITH PREVIOUSLY APPROVED USES TO REMAIN IN A DETACHED STRUCTURE.

  48. AppealZoning board appeal

    Appeal 26278 · CLOSED · Granted

    Related permit 636580 · PERMIT FOR USE AS DRUG AND ALCOHOL COUNSELING (BUSINESS AND PROFESSIONAL OFFICE) IN UNIT 1 SUITE 1.C.8 WITH PREVIOUSLY APPROVED USES TO REMAIN IN A DETACHED STRUCTURE.

  49. PermitElectrical

    Permit 668975 · COMPLETED

    INSTALL 8-150WATT ELECTRIC BASE BOARD HEATERS & A 60AMP SUB-PANEL ONTO AN EXISTING 400AMP 3 PHASE 4 WIRE SERVICE AS PER 2008 NEC (NORTH DISTRICT)

  50. PermitElectrical

    Permit 594260 · COMPLETED

    INSTALL LIGHT FIXTURES,SWITCHES,RECEPTACLES,EXIT AND EMERGECNY LIGHTS,BATHROOM EXHAUST FAN PER 2008 NEC (MIXED USE)

  51. PermitMechanical

    Permit 594116 · COMPLETED

    INSTALL HVAC AND DUCTWORK IN SINGLE TENANT SPACE. ALL IWTHIN ONE TENANT SPACE NO ROOF OR DEMISING WALL PENETRATIONS. NO UNIT OVER 2000 CFM. 46 DIFFUSERS.

  52. PermitPlumbing

    Permit 594266 · COMPLETED

    INSTALL 4 WATER CLOSETS,1 URINAL,2 LAVATORY,1 HAND SINK,1 MOP SINK AND 2 FLOOR DRAINS(MIXED USE)THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

  53. PermitSuppression

    Permit 593912 · COMPLETED

    RELOCATE 20 EXISTING SPRINKLER HEADS(COMMERCIAL)

  54. PermitUse

    Permit 593315 · COMPLETED

    FOR USE AS BUSINESS AND PROFESSIONAL OFFICE IN FIRST FLOOR SPACE 1.B.4 OF AN EXISTING BUILDING WITH OTHER PREVIOUSLY APPROVED USES.

  55. PermitMajor alteration

    Permit 591009 · COMPLETED

    LEVEL II INTERIOR ALTERATIONS WITH A PARTIAL CHANGE OF OCCUPANCY TO CREATE ADMINISTRATIVE OFFICES IN SPACE 1.B.4 ON THE FIRST FLOOR OF AN EXISTING MIXED USE BUILDING AS PER APPROVED PLANS. BUILDING FULLY SPRINKLERED. **SEPARATE PERMITS REQUIRED FOR ANY MEP OR FIRE SUPPRESSION WORK**

  56. PermitPlumbing

    Permit 547053 · COMPLETED

    INSTALL NEW ROUGH & FINISH PLUMBING 8-TOILETS, 8-SINKS, 2-URINALS, 1-KITCHEN SINK (MIXED USE)

  57. PermitElectrical

    Permit 439821 · COMPLETED

    PROVIDE LIGHTING, POWER AND FIRE ALARM- NO NEW DISTRIBUTION, FIRE ALARM INCLUDED IN PRICE PRINTS TO FOLLOW AS PER NEC 2008 & NFPA 72

  58. PermitElectrical

    Permit 461684 · COMPLETED

    TENANT ELECTRICAL FITOUT TO INCLUDE NEW LIGHTING, NEW BRANCH POWER AND DEVICES, NEW FIRE ALARM DEVICES, USE EXISTING SERVICE AND SWITCHGEAR AS PER 2008 NEC & NFPA 72(OFFICE BLDG)

  59. PermitPlumbing

    Permit 461788 · COMPLETED

    PLUMBING FOR TENANT FIT OUT OF INPATIENT FACILITY (INPATIENT MED FAC)

  60. PermitElectrical

    Permit 417722 · COMPLETED

    INSTALL 2X4 LIGHT FIXTURES, BRANCH POWER & DEVICES THROUGHOUT.

  61. InvestigationEP_ELEC

    Case 339799 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  62. ViolationPERME- INST/REPL/REPAIR WIRE (Electrical permit required for wiring installation, replacement, or repair)

    Case 339799 · Violation 2542754 · Code A-301.1/51 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  63. ViolationPENALTY- NO ELEC PERM INFO

    Case 339799 · Violation 2542755 · Code A-901.13/2 · COMPLIED

    City marked this violation complied with; check the resolution date and live case for what was accepted.

  64. InvestigationEP_ELEC

    Case 339799 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  65. PermitMechanical

    Permit 396677 · COMPLETED

    INSTALL HVAC & DUCTWORK IN ONE TENANT SPACE NO UNIT MORE THAN 2000 CFM, NO PENETRATION OF WALLS OR ROOF. 29 DIFFUSERS ALL EQUIPMENT AND ASSOCIATED DUCT WORK TO BE CONTAINED ENTIRELY WITHIN TENANT SPACE. NO COMMUNICATING DUCTWORK. GAS FIRED APPLIANCES NOT TO BE LOCATED IN CEILING SPACE WHERE USED AS A RETURN AIR PLENUM. RETURNS TO BE DUCTED.

  66. PermitElectrical

    Permit 369217 · COMPLETED

    FITNESS CENTER/BOWLING ALLEY - INSTALL 200 OWNER SUPPLIED LIGHT FIXTURES,INSTALL WIRING FOR BOWLING EQUIPTMENT,SUPPLY AND INSTALL (3) 225A PANELS UTILIZING EXISTING FEEDS AS PER 2008 NEC (NORTH DISTRICT)

  67. PermitPlumbing

    Permit 364543 · COMPLETED

    FURNISH AND INSTALL LAVATORIES,WATER CLOSET AND SINK FOR TENANT FIT OUT

  68. PermitMajor alteration

    Permit 364032 · COMPLETED

    TENANT FITOUT FOR FITNESS CENTER/BOWLING ALLEY AS PER PLANS. BUILDING IS FULLY SPRINKLERED.

  69. PermitUse

    Permit 342098 · COMPLETED

    A BOWLING CENTER AS PART OF AN EXISTING FITNESS CENTER WITHIN FALLS CENTER 1 IN THE BASEMENT/GROUND LEVEL OF AN EXISTING BUILDING WITH EXISTING BUILDING WITH FITNESS CENTER WITH TRAINING, JUICE BAR, TANNING SALON, HAIR SALON, LASER HAIR REMOVAL AND CHIROPRACTIC OFFICE IN FALLS CENTER 1 AS PART OF AN EXISTING RESIDENTIAL/COMMERCIAL COMPLEX WITH A TOTAL OF 350 DWELLING UNITS IN 1 & 2 FALLS CENTER (USE REGISTRATION PERMIT REQUIRED PRIOR TO OCCUPANCY) AND FOR MANUFACTURE OF ICE CREAM IN 2 FALLS CENTER, FOR A TAKE OUT RESTAURANT WITH SEATING IN GATE HOUSE BUILDING AND FOR 927 OFF STREET PARKING SPACES ALL AS PREVIOUSLY APPROVED - NO SIGNS ON THIS PERMIT

  70. AppealZoning board appeal

    Appeal 15760 · CLOSED · Granted

    Related permit 342098 · PERMIT FOR A BOWLING CENTER AS PART OF AN EXISTING FITNESS CENTER WITHIN FALLS CENTER 1 IN THE BASEMENT/GROUND LEVEL OF AN EXISTING BUILDING WITH EXISTING FITNESS CENTER WITH TRAINING, JUICE BAR, TANNING SALON, HAIR SALON, LASER HAIR REMOVA

  71. PermitSuppression

    Permit 362283 · COMPLETED

    RELOCATE 105 SPRINKLER HEADS (BASEMENT LEVEL)

  72. PermitElectrical

    Permit 313241 · COMPLETED

    INSTALL AND PROVIDE FIRE ALARM AS PER NFPA-72 AND PHILADELPHIA LOCAL CODES, INSTALL SMOKE WITH SOUNDER BASES TO PROVIDE DECIBEL LEVELS (NORTH DIST)

  73. PermitElectrical

    Permit 321913 · COMPLETED

    ROUGH IN AND FINISH 30 APARTMENTS,NO FIRE ALARM AS PER 2008 NEC

  74. InvestigationPRECOURT (likely: pre-court compliance inspection)

    Case 244765 · PASSED

    A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.

  75. PermitElectrical

    Permit 312250 · COMPLETED

    FURNISH/INSTALL:(1)CAT5C(VOICE)/(2)COAX CABLES TO (130)APTS,FURNISH/INSTALL FIBER OPTIC CABLING TO (4) FLOORS, FURNISH/INSTALL SECURITY WIRING-(14) EMER PHONES/(14)DELAYED EGRESS/(7)CAMERAS, AS PER 2008 NEC (NORTH DIST)

  76. InvestigationCI INSP

    Case 244765 · CLOSED

    City marked the record closed; open the case for the closing reason.

  77. PermitMechanical

    Permit 308673 · COMPLETED

    INSTALL WATERSOURCE HEAT PUMP AND DUCTWORK AS PER PLAN.

  78. InvestigationCI INSP

    Case 244765 · CLOSED

    City marked the record closed; open the case for the closing reason.

  79. InvestigationCI INSP

    Case 244765 · CLOSED

    City marked the record closed; open the case for the closing reason.

  80. InvestigationCI INSP

    Case 244765 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

  81. ViolationSHELTER PLN-REQ¿D

    Case 244765 · Violation 1845331 · Code FC-409.1/1 · COMPEXCP

  82. ViolationGENERATOR SET TEST REQ

    Case 244765 · Violation 1845336 · Code FC-604.4/2 · COMPEXCP

  83. ViolationSHELTER DRILL CONDUCT

    Case 244765 · Violation 1845332 · Code FC-409.5/1 · COMPEXCP

  84. ViolationFIRE-CURTAINS/DRAPES

    Case 244765 · Violation 1845333 · Code FC-805.1/3 · COMPEXCP

  85. ViolationVIOL C&I MESSAGE

    Case 244765 · Violation 1845335 · Code A-000.0/10 · COMPEXCP

  86. InvestigationCI INSP

    Case 244765 · FAILED

    The cited inspection visit was marked failed; later rows may show follow-up or resolution.

Where this comes from

Methodology & freshness

This report was assembled Jul 26, 2026, 8:54 PM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.

Official city record ↗  ·  L&I history ↗  ·  See the whole block  ·  Download this record (JSON)